You are on page 1of 1

PRODUCED BY AN AUTODESK STUDENT VERSION

Street dimension = 1000 m No. of Lamps Required :


Width of the road = 20 m
Height of the pole = 8m Illumination level
Lamp wattage = 125 watts =
Efficiency of the lamp = 10 lumens per watt Lumens per lamp
Candle power = 300 CP
30,200 Lumens
=
1,250 Lumens per lamp
Area :
A= Street distance x Width of the road = 24 Lamps X 2

= 1000 m x 20 m = 48 Lamps
2
A= 20,000 m

PRODUCED BY AN AUTODESK STUDENT VERSION


1 Lamp is equivalent to 1 pole;
PRODUCED BY AN AUTODESK STUDENT VERSION

Illumination required : 48 Lamps = 48 Pole

CP
EV= cos Ø
D2 Pole distance :
OPPOSITE STREET LIGHT DESIGN Street distance
300 8 =
= No. of pole
11.67 2 11.67
1000 m 2
E V = 1.51 Lux =
48 Pole
= 20.83 meter per pole
8m 8m
Lux Requirements :
= Lux x Area
= 1.51 Lux x 20,000 m 2
1.5 m 1.5 m
8.5 m 8.5 m
= 30,200 Lumens
20 m
Therefore :
SCHEMATIC DIAGRAM In one kilometer street lighting the lamp required is 48
lamps also the pole required is 48 pole, and the distance of every
Output of each Lamp : pole is 20.83 meter per pole. With an efficiency of the lamp of 10
lumens per watt.
= Lumens per watt x lamp wattage
= 10 Lumen x 125 watts
2 2 2
8m X = √ (8.5 m) + (8 m) = 1,250 lumens per lamp
X = 11.67 m

8.5 m

Submitted by : HAROLD A. AÑASCO

SJIT STREET LIGHTING DESIGN AND CALCULATION


EE - 10 1:00 - 6:00 PM
BUTUAN CITY
SCALE: 1:10 DATE SUBMITTED : 11-16-19 Submitted to : ENGR. ROGELIO GONZALES

PRODUCED BY AN AUTODESK STUDENT VERSION

You might also like