Professional Documents
Culture Documents
075
075
Untung Budiarto
Dept. Naval Architecture
Faculty of Engineering, Diponegoro
University
Semarang, Indonesia
budiartountung@gmail.com
353
Advances in Engineering Research, volume 167
C. Ship Capacity
Ship capacity of hull calculated by the method of the
Simpsons. See Fig 5.
QtotQdQp
by:
Q tot = Load Total (watt)
(2)
by:
qd = Load Cool of System (watt)
T1 = Temperature on Top (oC)
T4 = Temperature on Base (oC)
kaA = Termal Conductifity Fish Hold (W/m.C)
kaB = Termal Conductifity Fish (W/m.C)
kaC = Termal Conductifity Hull (W/m.C)
△Xa = Space / Area component Fish Hold (m2)
354
Advances in Engineering Research, volume 167
△Xb = Space / Area frame Fish Hold (m2) △h = Range of Temperature (oC)
△Xc = Space / Area thickness of insulation Fish Hold (m 2)
F2. Condenser
Heat dissipation in isobaric in condenser, by
To calculated load of product, use formula :
formula :
by :
q = Load (kJ/kg)
w = Energy (kJ/kg)
△h = Range of Temperature (oC)
q – w = △h (4) (7)
355
Advances in Engineering Research, volume 167
ACKNOWLEDGMENT
This research was supported/partially supported by
Dit.litabmas Kemenristek Dikti. We thank our colleagues
from Diponegoro University who provided insight and
expertise that greatly assisted the research, although they
may not agree with all of the interpretations/conclusions of
this paper.
356