You are on page 1of 1

DESIGN CALCULATION FOR SEISMIC LATERAL FORCE

***DEFINE 1893 LOAD


********ZONE III Z=0.16,CONSIDERED THE MUMBAI CITY.
********MOMENT RESISTANCE FRAME WITH SHEAR WALL R = 5,IMPORTANCE FACTOR I = 1.0
********SOIL TYPE IS MEDIUM SS=2,
**********HT OF STRUCTURE 5.62M, B = 1.8M & L = 8.96M TIME PERIOD To = 0.09*h / SQRT(B/L)
***ZONE 0.16 RF 5 I 1.0 SS 2 ST 1 DM 0.05 PX 0.28 PZ 0.06
B= 1.8 WIDTH OF STRUCTURE
L= 8.96 LENGTH OF STRUCTURE

I= 1
Z= 0.16
R= 5
H= 5.62
Px = 0.38
Pz = 0.17
Sa/g = 2.5

AH 0.04

WITHOUT LL

Node L/C Force-Y kN


201 3 3.183
294 3 3.179
295 3 2.382
296 3 2.391
400 3 3.985
424 3 3.933
425 3 0.543
426 3 0.538

LOAD 12 LOADTYPE Seismic TITLE SISC X+VE (WITHOUT LL) LOAD 13 LOADTYPE Seismic TITLE SISC Z+VE (WITHOUT LL)
JOINT LOAD JOINT LOAD
201 FX 0.13 201 FZ 0.13
294 FX 0.13 1 294 FZ 0.13 1
295 FX 0.10 295 FZ 0.10
296 FX 0.10 296 FZ 0.10
400 FX 0.16 400 FZ 0.16
424 FX 0.16 424 FZ 0.16
425 FX 0.02 425 FZ 0.02
426 FX 0.02 426 FZ 0.02