BIB - Daily Online Machine Defects-C

Date S.no Machine Shift Problem

04.11.2019 1 Filling machine G Vertical leak

Vertical seal width less


04.11.2019 2 Filling machine G than 7mm, white line
issue

04.11.2019 3 Filling machine G Horizontal leakage

Low weight / High


04.11.2019 4 Filling machine G
weight

Batch code miss /


04.11.2019 5 Pampac G
misalignment

05.11.2019 6 Filling machine G Pouch damages


BIB - Daily Online Machine Defects-CAPA
Responsibilit
Root Causes Corrective Action Target date
y
Pressure bolt tightened Thangaraj 10.11.2019
Pressure bolt tighten condition to be
Shanmugam 11.11.2019
included in 4M condition checks
Pressure bolt getting loosened
Training to be provided to all the
technicians executives on 4M condition Thangaraj 11.11.2019
checks

Web alligner programming to be fine


Murugan 12.11.2019
tuned with the help of service engineer
Web alligner issue
Encoder to be finetuned in fillig
Murugan 11.11.2019
machine
forming tube hit by manually Training to be provided to all the
during the operation to clear off technicians executives not to hit the
Thangaraj 10.11.2019
the fine powder accumulation in forming tubes or any of the machine
pin closures parts without stopping the machine
Check weigher to be interfaced
Murugan 11.11.2019
Check weigher not with filling machine
interfaced with the filling Take off conveyor length to be
machine increased upto check weigher Murugan 11.11.2019
to ensure the smooth operation
First 5 BIB to be rejecetd
automatically whenever machne Murugan 12.11.2019
Frequent stoppage of
stop & start
pampac machine
Laser printer to be relocated
Murugan 15.11.2019
before top glue
Sharp edges in the guards Rubber / nylon beeding to be
Thangaraj 10.11.2019
of the conveyors provided to all the side guards