CODE DATA: 2017 OHIO BUILDING CODE (OBC)

OCCUPANCY CLASSIFICATION: A-3 ASSEMBLY


(COMMUNITY HALL)
14
7 11
OCCUPANT LOAD: TABLE 1004.1.2
1
MAX. FLOOR AREA ALLOWANCES PER OCCUPANT: 15 SQ. FT. NET
4 13
CONSTRUCTION TYPE: VB
2
ALLOWABLE STORIES ABOVE GRADE PLANE: 1 STORY 11

G
ALLOWABLE BUILDING HEIGHT (TABLE 504.3) = 40 FEET (NS) 8
1
ACTUAL BUILDING HEIGHT: 17'-0" +/- 12 14 11 T

ALLOWABLE BUILDING AREA (TABLE 506.2): 6,000 SQ. FT. (NS)


ACTUAL BUILDING AREA: 3,190 SQ. FT. 1
BEARING WALL (EXTERIOR): 0 HOUR 6
NON-BEARING WALLS (EXTERIOR): 0 HOUR 3
9

G
NON-BEARING WALLS (INTERIOR): 0 HOUR
ROOF CONSTRUCTION: 0 HOUR CW 5
14
OCCUPANT LOAD: 3,190 SQ. FT. / 15 SQ. FT. PER OCCUPANT = 213 OCCUPANTS
G
NO SPRINKLER REQ'D PER OBC SECTION 903.2.1.3. OCCUPANT LOAD IS LESS THAN 300. 11
4
14

15 10

DATE
- DEMOLITION CODED NOTES:

1.) REMOVE UNVENTED GAS-FIRED HEATER, TYP. FOR 3.


2.) EXISTING GAS-FIRED UNIT HEATER TO REMAIN.
3.) REMOVE EXISTING GAS BRANCH PIPING TO UNIT HEATER.
4.) REMOVE GAS SERVICE, METER, & PIPING TO UNVENTED HEATERS.
5.) EXISTING WATER HEATER TO REMAIN. REMOVE ALL HOT WATER PIPING. DEMOLITION FLOOR PLAN

N
6.) RELOCATE EXISTING UTILITY SINK.
7.) REMOVE EXISTING FLOOR DRAIN, TYP. FOR 3. SCALE: 1/8" = 1'-0"
8.) REMOVE EXISTING SANITARY VENT THRU ROOF.

REVISIONS
9.) REMOVE INTERIOR COLD WATER PIPING BACK TO SHUTOFF VALVE NEAR FLOOR.
10.) REMOVE EXISTING DOORS TO BE REPLACED, TYP. 6.
11.) DEMOLISHED EXISTING WALLS AND PARTITIONS AS INDICATED ON DRAWINGS.
12.) REMOVE EXISTING PLUMBING FIXTURES, CUT AND CAP PIPES. TYP. 8.
13.) SAWCUT EXISTING CONCRETE SLAB TO EXPOSE SANITARY PIPING, AND REMOVE.
14.) DEMOLISH EXISTING GYPSUM BOARD CEILING.
15.) EXISTING WINDOWS TO BE DEMOLISHED. TYPICAL OF 4.
3± EXISTING GIRDER EXISTING RAFTERS
INFILL MASONRY. SEE FLOOR PLAN ON SHEET 2.
TRUSS TO REMAIN TO REMAIN

DESCRIPTION
16.) DEMOLISH EXISTING SHINGLES/ FELT, ROOF DECK AND RAFTERS.
17.) DEMOLISH ALL GUTTERS AND DOWNSPOUTS.

REV.
DEMOLITION GENERAL NOTES:

AS NOTED

ADT

ADT

ADT
XX% REVIEW
1.) DEMOLITION DRAWING INCLUDES ONLY DEMOLITION SCOPE RELATED

ISSUED FOR:

ISSUE DATE:

03/21/19
TO THE EXISTING STRUCTURE AND ROOF FRAMING IN DIRECT RELATION

DESIGNED BY:

CHECKED BY:
TO THE PROPOSED ADDITION LOCATION.

DRAWN BY:
2.) FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO DEMOLITION.

SCALE:
3.) NOTIFY ARCHITECT OF ANY DISCREPANCIES BETWEEN ACTUAL EXISTING

MADISON, OHIO
CONDITIONS AND THESE DOCUMENTS.

DEMOLITION PLANS AND NOTES


EXISTING TRUSSES
4.) IN AREAS OF DEMOLITION WHERE FINISHES ARE TO REMAIN, SURFACES ARE TO TO REMAIN
BE PROTECTED AND CONTRACTOR SHALL BE RESPONSIBLE FOR REPAIR OF ANY
DAMAGES. 16

PARK BUILDING IMPROVEMENTS


5.) MAINTAIN MASONRY MOUNTED LEDGER BOARD ON EASTERN SIDE OF
BUILDING FOR FUTURE 2 x 6 JOISTS OF ADDITION.

SITE PLAN, CODE DATA,


MADISON TOWNSHIP
EXISTING RAFTERS
TO REMAIN

DEMOLITION ROOF FRAMING PLAN

N
SCALE: 1/8" = 1'-0"

LAKE COUNTY
PROJECT NO.

181028
DISCIPLINE

ARCH
SHEET NAME

A-01
SHEET OF