SmartOne Protocol
Photoelectric Smoke Detector Effective: January 2017
FOR KIDDE FIRE SYSTEMS INTELLIGENT CONTROL UNITS K-76-101
FEATURES
• Optical smoke sensing technology • Attractive 6 in. diameter trim ring provided with bases
• Field-replaceable smoke chamber • Electronic Addressing performed with SmartOne
• Works with SmartOne communication protocol
® Hand-Held Programmer
• Compatible with Kidde, Fenwal and Chemetron • Advanced data analysis reduces chance of nuisance
branded intelligent control units alarms
• Operates in conjunction with SmartOne CPD-7052, • Two-color (green/red) LED
PSD-7152 and THD-7252 legacy detectors • Suitable for raised floor and plenum applications
• Detector head and terminal base design • FM Approved
(bases sold separately) • cULus Listed
• Low-profile design blends into ceiling • California State Fire Marshal Listed
DESCRIPTION
The DS-PS Photoelectric Smoke Detector is an intelligent device
that uses an optical photoelectric sensing chamber to detect
smoke. The detector’s built-in microprocessor measures and
analyzes sensor readings, making comparisons to historical data
and filtering signal patterns that are not typical of fires to prevent
unwanted alarms. The practical design of the DS-PS increases
efficiency, saves installation time, cuts costs and extends life
safety and property protection capabilities.
The DS-PS detects extremely small particles of combustion and
triggers an alarm at the first sign of smoke. With its high-perfor-
mance forward scattering reflective response technology, the
photoelectric smoke sensor responds quickly and reliably to a
INSTALLATION
wide range of fire types, especially slow burning fires fueled by A DS-PS detector mounts to North American 1-gang boxes, 3-1/2
combustibles typically found in modern multi-use buildings. inch or 4 inch octagon boxes, and to 4 inch square electrical
boxes 1-1/2 inches (38 mm) deep.
ADDRESSING
DS-PS detectors feature electronic addressing. No addressing
LOCKING FEATURE
switches are used. The compatible detector bases include an optional locking fea-
ture that prevents removal of the detector without use of a tool. To
LEDS eliminate this feature, prior to placing the detector in a difficult-to-
DS-PS detectors use an LED to indicate the detector’s condition. reach location, break and remove the plastic lever arm from the
In normal condition, a flashing green LED indicates that the con- base.
trol unit is performing background supervision and a flashing red
SENSITIVITY
LED indicates an alarm condition.
The alarm sensitivity is the minimum obscuration level at which
LED PULSE MODES the detector initiates an alarm condition and can be specified via
• Normal, Standby: (green) flash at 9-second repetition rate the control unit menus or the remote configuration software. The
• Alarm: (red) flash at 2.5-second repetition rate control unit to which the detectors are connected is capable of
interrogating each detector to determine its sensitivity. The table
below lists the acceptable smoke sensitivity ranges for open air
and in-duct detection:
ORDERING INFORMATION
DS-PS Intelligent Photoelectric Smoke Detector, SIGA-DMP Duct mounting plate for DS-PS detector
head only
2-SPRC1 Replacement smoke chamber for DS-PS
DS-SB Detector Mounting Base, 4 in. diameter,
with 6 in. trim ring, for 2-wire connection to 70-600000-100 SmartOne Hand-Held Programmer and
SmartOne SLC accessories with DS Series Detector
Programming Adapter
DS-RB Detector Mounting Base, 4 in. diameter,
with relay option and 6 in. trim ring, for 2- 70-600000-110 DS Series Detector Programming Adapter
wire connection to SmartOne SLC
SM200-12PKG Canned smoke for functional testing of
smoke detectors
2 K-76-101
3
TO SMARTONE DS-PS or DS-HFS
CONTROL UNIT CPD-7052, PSD-7152 DETECTOR TO
OR or THD-7252 DETECTOR NEXT
4
ANOTHER DETECTOR
DETECTOR
(Not Polarity
Sensitive) 7 2
K-76-101 3
Effective: January 2017
TERMINAL DESIGNATIONS:
Number Description
1 Not used
2 SLC IN/OUT
3 Not used
4 SLC IN/OUT
5 Not used
6 Not used
7 Not used
TERMINAL DESIGNATIONS:
Number Description
1 Normally Open
2 SLC IN/OUT
3 Common
4 SLC IN/OUT
5 Not used
6 Normally Closed
7 Not used
This literature is provided for informational purposes only. Kidde-Fenwal believes this data to be accurate, but it is published and presented without any guarantee or
warranty whatsoever. Kidde-Fenwal, Inc. assumes no responsibility for the product’s suitability for a particular application. The product must be properly applied to work
correctly.If you need more information on this product, or if you have a particular problem or question, contact Kidde-Fenwal, Inc., Ashland, MA 01721 USA.