You are on page 1of 88

Siemens Connectivity to

EtherNet/IP Networks TM

A comprehensive and flexible solution with


“Best-in-Class” features
Siemens Answers
“Best-in-Class” EtherNet/IP features

• We will provide answers

 Why should you consider using


Siemens products?

 What does Siemens offer for


EtherNet/IP networks?

 How does Siemens products


connect easily to EtherNet/IP?

 What are the benefits for you?

Best-in-Class
EtherNet/IP™
Solutions 2 10/12/2015 Copyright © 2014 Siemens Industry, Inc.
How does the market look like?

Industrial Ethernet & Fieldbus

Global Market Share US Nodes in Industrial Ethernet by Protocol

800
EtherNet/IP
700 17.4% Growth

600
500
400
PROFINET
300
21.6% Growth
200
100
0
2010 2011 2012 2013 2014 2015

Source: IMS Report „The World Market for Industrial Ethernet & Fieldbus Technologies“ 2013
Best-in-Class
EtherNet/IP™
Solutions 3 10/12/2015 Copyright © 2014 Siemens Industry, Inc.
FAQ’s

• What is EtherNet/IP?
• EtherNet/IP is an Industrial Ethernet protocol supported by the ODVA
organization with principle members Rockwell Automation, CISCO, and
Schneider Electric.

• Is Siemens a member of the ODVA association?


• Siemens is a licensed vendor with ODVA (Open DeviceNet Vendor Assoc)

• What is the difference between EtherNet/IP and PROFINET?


• They are two different protocols that run on Industrial Ethernet networks.
PROFINET offers many technical advantages but with the AB installed base
in North America there are many occurrences with E/IP connectivity.

Best-in-Class
EtherNet/IP™
Solutions 4 10/12/2015 Copyright © 2014 Siemens Industry, Inc.
Siemens offers
A Comprehensive Solution using Your PLC

• A 3rd-party PLC configured for EtherNet/IP can be used with all


these Siemens products
Remote I/O HMI Hardware &
Software Industrial
Computers

FastConnect Cabling Network Switch Drives


and Connectors

PC/Network Wide Range of


SINAMICS DCM SINAMICS G120 SINAMICS S120
Best-in-Class (DC drives) G120C, G120D G130, G150, S150 RFID selections
EtherNet/IP™
Solutions 5 10/12/2015 Copyright © 2014 Siemens Industry, Inc.
SIMATIC
Distributed I/O
Multifunctional,
modular and
precisely
scalable
systems for distributed
automation
Siemens Distributed I/O

• What does Siemens offer?


• The SIMATIC ET200S I/O system delivers multiple discrete,
analog and counter modules and both direct and
reversing motor starters
• It provides very simple field
repair with hot swapping,
and fixed field wiring
SIMATIC ET200S I/O
system competitive advantages include
 Up to 80% less wiring
 Up to 60% less configuration and
documentation overhead
 Up to 50% more space in control cabinet

Best-in-Class
EtherNet/IP™
Solutions 7 10/12/2015 Copyright © 2014 Siemens Industry, Inc.
SIMATIC ET200S Distributed I/O
EtherNet/IP solutions

• How does Siemens I/O connect easily to EtherNet/IP?


• The SIMATIC ET200S I/O Port 1 Port 2
module is used in
Status
conjunction with the LEDs
EIP-200S adapter interface
module for seamless Label
Area
connection to EtherNet/IP
networks Port 1 /
Port 2
Link LEDs

Power SD Card
Connector Slot

TheThe only
only remote
remote I/OI/O solution
solution where a user can standardize
on both PROFINET and EtherNet/IP while maintaining permanent
where
field a with
wiring user motor
can standardize
starters
Best-in-Class
EtherNet/IP™
Solutions 8 10/12/2015 Copyright © 2014 Siemens Industry, Inc.
SIMATIC
HMI Hardware
Now with
EtherNet/IP
connectivity,
SIMATIC HMI is
engineered to
meet the
increasingly
complex
processes of all
machines and
systems
The SIMATIC HMI Hardware Family

• What does Siemens offer?


• With direct network connectivity
to PROFINET, EtherNet/IP, Basic
Modbus TCP/IP, and other Panels Comfort
Ethernet drivers, SIMATIC HMI Panels
Panels offer best in class
visualization when combined with
most third party controllers
• Our focus is on the popular
Comfort Panels
 SIMATIC HMI Comfort Panels
are brilliant, protected, and
rugged while delivering
maximum performance and
functionality Mobile

Panels
Best-in-Class
EtherNet/IP™
Solutions 10 10/12/2015 Copyright © 2014 Siemens Industry, Inc.
The SIMATIC HMI Hardware Family
System-tested and approved

• How does Siemens HMI connect easily to EtherNet/IP?


• Fast and easy connection to MicroLogix ,
SLC, ControlLogix, or CompactLogix

Best-in-Class
EtherNet/IP™
Solutions 11 10/12/2015 Copyright © 2014 Siemens Industry, Inc.
Tag Migration Tool
RS Logix tags easily imported into WinCC software

Best-in-Class
EtherNet/IP™
Solutions 12 10/12/2015 Copyright © 2014 Siemens Industry, Inc.
The SIMATIC HMI Hardware Family
System-tested and approved

• How does Siemens HMI connect easily to EtherNet/IP?


• Communication • PLCs
Types  CompactLogix
 Point-to-point  532xE (1769-L2xE) with Ethernet interface
connection to the onboard
approved PLCs  533xE (1769-L3xE) with Ethernet interface
onboard
 Multipoint connection
 534x (1768-L4x) with Ethernet module 1768-
from HMI device ENBT
(Allen-Bradley
 ControlLogix 556x (1756-L6x) with Ethernet
EtherNet/IP-Client)
module 1756-ENBT
with up to 4 PLCs with
the respectively  Guard Logix-System ControlLogix 556xS
approved PLCs (1756-L6xS) with Ethernet module 1756-
 CPU types can be
ENBT
mixed  MicroLogix
 1100 (with Ethernet interface onboard)
 1400 (with Ethernet interface onboard)
Connectivity to 90% of  SLC 5/05 (with Ethernet interface onboard)
Best-in-Class
Rockwell CPU families
EtherNet/IP™
Solutions 13 10/12/2015 Copyright © 2014 Siemens Industry, Inc.
RFID Systems

Industry-
leading RFID
and code
reading
solutions to
increase
transparency
in the
manufacturing
process
The SIMATIC Ident Family

• What does Siemens offer?


• RFID and code reading systems
 1D and 2D codes
• Comprehensive technologies
available on common
EtherNet/IP networking and
programming interface
 HF, UHF, Active Tags and Code
Reading

Best-in-Class
EtherNet/IP™
Solutions 15 10/12/2015 Copyright © 2014 Siemens Industry, Inc.
The SIMATIC Ident Family
EtherNet/IP solutions

• How does Siemens HMI connect easily to EtherNet/IP?


• SIMATIC Ident connection into Allen Bradley PLC via EtherNet/IP
with RF181EIP

Logix Platform

RF 181EIP

SIMATIC RF300 SIMATIC RF600


Best-in-Class
SIMATIC RF 200
EtherNet/IP™
Solutions 16 10/12/2015 Copyright © 2014 Siemens Industry, Inc.
Networking
Infrastructure
Wireless HW
and managed
switches
— made By
Engineers
For Engineers
The SIMATIC Networking Family

• What does Siemens offer?


• Scalance W Wireless LAN
 Solution for reliable and secure
automation networking needs
• Scalance X Industrial Ethernet
switches and media converters
 Complete solution for all
automation networking needs

Best-in-Class
EtherNet/IP™
Solutions 18 10/12/2015 Copyright © 2014 Siemens Industry, Inc.
Wireless Drive Solutions on EtherNet/IP or Profinet
802.11abg – “RR”-Devices Ex. Paint shop conveyor
Monorail overhead conveyor and Lift application
Access Point
Wireless LAN RCoax Antenna

Client Drives
802.11agn – Devices

KEY-
PLUG

Access Point Access Point Access Point

Roaming… Roaming…

Client

Best-in-Class
EtherNet/IP™
Solutions 19 10/12/2015 Copyright © 2014 Siemens Industry, Inc.
Scalence X Industrial EtherNet
EtherNet/IP solutions

• EtherNet/IP requires IGMP snooping, supported in the following


Scalence X Product Features Overview
 Networking and structuring of high-performance industrial networks
 Modular adaptability to the task in hand
X-500  Expanded range of functions (IT functionality, layer 3, router redundancy)
 Diagnostics using SNMP, Web server, STEP 7, on-site diagnostics
 Networking and structuring of high-performance industrial networks
 Modular adaptability to the task in hand
X-400  Expanded range of functions (IT functionality, layer 3, router redundancy)
 Diagnostics using SNMP, Web server, STEP 7, on-site diagnostics
 Networking of plant sections / plant areas
 Modular adaptability to the task in hand
X-300  Expanded range of functions (VLAN, port security etc.)
 Diagnostics using SNMP, Web server, STEP 7, on-site diagnostics

• Customer benefits
 Simple configuration using the integrated Webserver
 Gigabit switches for higher performance in automation applications
 Versions with full modularity allow flexible use in nearly every application
 C-Plug memory allows easy and tool-free maintenance
Best-in-Class  Cable and Network diagnostics
EtherNet/IP™
Solutions 20 10/12/2015 Copyright © 2014 Siemens Industry, Inc.
Industrial
Cabling
Siemens offers FastConnect,
a system that fulfills all
stringent industrial
requirements:
On-site
assembly
- quick, easy
and error-free
Siemens Cabling Technology

• What does Siemens offer?


• Siemens FastConnect
Cabling for EtherNet/IP
• The most superior cabling
solution in the market
 Cabling and Connectors
 Time-saving, error-free field
assembly of custom length
industrial grade Ethernet
cables

A perfect electrical
connection in less than
60 seconds

Best-in-Class
EtherNet/IP™
Solutions 22 10/12/2015 Copyright © 2014 Siemens Industry, Inc.
Siemens Devices on Ethernet via PROFINET protocol

Line Topology
Least Expensive Cabling

Ring Topology

Best-in-Class
EtherNet/IP™ Star Topology
Solutions 23 10/12/2015 Copyright © 2014 Siemens Industry, Inc.
Siemens Devices on Ethernet via EtherNet/IP protocol

Line Topology
Least Expensive Cabling **

Ring Topology

*Must be end device


Best-in-Class ** Must have redundancy manager
EtherNet/IP™ Star Topology
Solutions 24 10/12/2015 Copyright © 2014 Siemens Industry, Inc.
SINAMICS
Drives
Siemens is the global
leader in drive
technology,
offering a
flexible, efficient,
established
solution
Siemens Drive Family available on EtherNet/IP

Today’s focus – SINAMICS G120 VFD


Best-in-Class
EtherNet/IP™
Solutions 26 10/12/2015 Copyright © 2014 Siemens Industry, Inc.
SINAMICS – One True Family of Drives

CU Power
P3 P3 P3
P4
P4 P4
P5
P5 P5
P6
P6 P6 P7
P7 P7 P20
P100 P30 P21
P101 P31 P30
P102 P32 P31
P103 P33 P32
P33
P104 P34
P34
P300 P100 P50
P301 P101 P51
P302 P102 P100
P303 P103 P101
P104 P102
P200 P103
P104
P201
P150
P300 P151
P301 P200
P302 P201
P303 P300
P301
P302
P303
Best-in-Class
EtherNet/IP™
Solutions 27 10/12/2015 Copyright © 2014 Siemens Industry, Inc.
SINAMICS Converters
Power and performance for any application

Converter Application Feature

 Simple and basic tasks


 Compact and integrated operation
 Greater ruggedness
SINAMICS V

 Single-axis applications
 Optimized to your needs
SINAMICS G  Allow more efficient solutions

 Multi-axis applications
 Superior functionality
 Wide power range
SINAMICS S
Best-in-Class
EtherNet/IP™
Solutions 28 10/12/2015 Copyright © 2014 Siemens Industry, Inc.
SINAMICS G120
The modular inverter – flexible, safe and efficient

Power Module
“THE MUSCLE”
“THE BRAIN”

“THE EYES”

Best-in-Class
EtherNet/IP™
Solutions 29 10/12/2015 Copyright © 2014 Siemens Industry, Inc.
SINAMICS G120
The modular inverter – flexible, safe and efficient

Basic Safety With


applications functions positioning

Best-in-Class
EtherNet/IP™
Solutions 30 10/12/2015 Copyright © 2014 Siemens Industry, Inc.
SINAMICS G120
The modular inverter – flexible, safe and efficient

Operation without
commissioning!

Best-in-Class
EtherNet/IP™
Solutions 31 10/12/2015 Copyright © 2014 Siemens Industry, Inc.
SINAMICS G120
Modularity – Eyes, Brains & Muscle

BOP-2
 Display for commissioning and

SINAMICS
Operator
diagnostics
Control

Panel
Power
Modul

G120
Unit

+ + =
e

 …+ intuitive menu guidance due to


IOP Application Wizard and graphics. Also
available as handheld version

CU230P-2  Pumps, fans, compressors

CU240B-2
 General machinery constructions with
basic I/O structure

CU240E-2
 General machinery constructions with
+ + = basic I/O structure and safety.

 General machinery constructions with


CU250S-2
extended I/O structure, encoder
interface, Epos Positioning and
NEW extended safety functions.

PM240
 Multiple applications in general
machinery constructions.

PM240-2  … + 230V 1&3ph, Push-Through


version, same PM for G120 & S120
NEW blocksize* (* from firmware V4.7)
PM250  …+ energy regen. back to the grid.
PM260*  690V applications, includes sinus filter
Best-in-Class
EtherNet/IP™
Optional accessories/spare parts: memory cards, shield connection kit, PC inverter connection kit, fans etc.
Solutions 32 10/12/2015 Copyright © 2014 Siemens Industry, Inc.
SINAMICS G120
Power Module for regenerative feedback

Energy savings
generated

Module with Module with


braking resistors regeneration

Best-in-Class
EtherNet/IP™
Solutions 33 10/12/2015 Copyright © 2014 Siemens Industry, Inc.
SINAMICS G120
Safety functions are integrated into the inverter

EN954-1 Category 3

IEC61508 SIL2

Best-in-Class
EtherNet/IP™
Solutions 34 10/12/2015 Copyright © 2014 Siemens Industry, Inc.
PROFIsafe on PROFINET
Safety over the network

Best-in-Class
EtherNet/IP™
Solutions 35 10/12/2015 Copyright © 2014 Siemens Industry, Inc.
SINAMICS G120
Memory Card – parameter cloning

Parameter Cloning

Feature: MMC allows for parameter cloning & backup


Benefit: Allows users to save time on initial
commissioning by cloning parameters across matching
drives via MMC

In case of failure of control unit, users can install a


backed-up copy of parameters to new control unit via
MMC, thereby lowering downtime

Best-in-Class
EtherNet/IP™
Solutions 36 10/12/2015 Copyright © 2014 Siemens Industry, Inc.
SINAMICS G120
Intelligent Operator Panel (IOP)

Enhanced Diagnostics

Feature: Access to entire G120 Manual


Benefit: User will have access to not only error codes,
but also causes and remedies to these errors, thereby
lowering downtime if a failure happens

Feature: On board Trace Function


Benefit: For quick troubleshooting, perform a trace
directly from the operator panel for troubleshooting
help during first commission or regular operation

Feature: I/O Assignment


Benefit: Quick identification or troubleshooting of
Inputs & Outputs assignments, commands or enables
Best-in-Class
EtherNet/IP™
Solutions 37 10/12/2015 Copyright © 2014 Siemens Industry, Inc.
SINAMICS G120D
D = Distributed Drive, the conveyor specialist

OR

PROFINET EtherNet/IP

DC 24 V

G120D
3AC 480V

SIMOGEAR

SIMOTICS GP
Best-in-Class
EtherNet/IP™
Solutions 38 10/12/2015 Copyright © 2014 Siemens Industry, Inc.
Hands On Lab

Best-in-Class
EtherNet/IP™
Solutions 39 10/12/2015 Copyright © 2014 Siemens Industry, Inc.
Hands On Lab

Best-in-Class
EtherNet/IP™
Solutions 40 10/12/2015 Copyright © 2014 Siemens Industry, Inc.
Hands On Lab

• Pre-work
Programmed prior to the workshop

 TIA Portal
 S7-1500 project configured for 6 drives
 ComfortPanel project configured for 6
drives over PROFINET and EtherNet/IP

 RSLogix

 ControlLogix project configured for 6


drives using Add-on Instructions (AOI)

Best-in-Class
EtherNet/IP™
Solutions 41 10/12/2015 Copyright © 2014 Siemens Industry, Inc.
Programming Rockwell Logix family PLC
SIEMENS videos & manuals available for the below steps

Add Add-on
Instructions to the
• A Generic IO module is file
used to configure the
cyclic data exchange • Import the AOI into the
between the controller Add On Instructions
and the drive without folder.
an EDS file. • Import the required
L5K file for the desired
Instruction.
Add generic
Ethernet module

Best-in-Class
EtherNet/IP™
Solutions 42 10/12/2015 Copyright © 2014 Siemens Industry, Inc.
Hands On Lab

Programmed prior to the workshop


 Lab 1
 Commission each drive to motor using STARTER

 Lab 2
 Setup PROFINET to S7-1500 and control via HMI

 Lab 3
 Setup EtherNet/IP to ControlLogix and control via HMI

 Lab 4
 Switch half of drives back to PROFINET and run both
protocols at the same time

Best-in-Class
EtherNet/IP™
Solutions 43 10/12/2015 Copyright © 2014 Siemens Industry, Inc.
Back From Hands On Lab

Best-in-Class
EtherNet/IP™
Solutions 44 10/12/2015 Copyright © 2014 Siemens Industry, Inc.
SINAMICS G120 Commissioning
SIPEC - EtherNet/IPTM workshop

Best-in-Class
EtherNet/IP™
Solutions 45 10/12/2015 Copyright © 2014 Siemens Industry, Inc.
STARTER
About this lab

This lab provides instructions for commissioning a


G120 Drive using STARTER software. The steps
covered include creating the project, discovering
and uploading the drive configuration, execution of
the commissioning wizard and motor tuning. This
lab was developed to use in conjunction with the
SIPEC G120 EtherNet/IP Workshop

Best-in-Class
EtherNet/IP™
Solutions 46 10/12/2015 Copyright © 2014 Siemens Industry, Inc.
STARTER
Create a new project

Create a new project in STARTER.


1. In the STARTER Menu go to … Project > New
2. In the New Project box, enter a project name and press OK

Best-in-Class
Continue to the next page
EtherNet/IP™
Solutions 47 10/12/2015 Copyright © 2014 Siemens Industry, Inc.
STARTER
Create a new project

Now you should see this file structure in the Project Menu
with your project name at the top. In this example the
project name is My EIP.

Best-in-Class
Continue to the next page
EtherNet/IP™
Solutions 48 10/12/2015 Copyright © 2014 Siemens Industry, Inc.
STARTER
Accessible Node

Next you will have STARTER discover the drive and upload the configuration to your project.

INSTRUCTOR, leave the switch turned OFF so each station finds their own drive only.

3. When the search is finished, a G120


1. Locate and click on the Accessible drive should be shown as seen below.
Nodes button on the Tool Bar. You
can also find the Accessible Nodes
selection in the Project menu.
2. A progress bar will be present while
the search is in progress.

Best-in-Class
Continue to the next page
EtherNet/IP™
Solutions 49 10/12/2015 Copyright © 2014 Siemens Industry, Inc.
STARTER
Setting the IP Address and PROFINET Name

Next you need to set the IP address and PROFINET name in the drive.
NOTE: The PROFINET name is needed for the SIMATIC controller.

1. Simply click on the SINAMICS bus node. It will highlight blue as shown below.
2. Hover the mouse over the node and press the right mouse button.
3. A box will open with a selection to Edit Ethernet Node … , click on that selection.
4. The Edit Ethernet Node box will open.
5. Continue to the next page for additional instructions.

Best-in-Class
EtherNet/IP™
Solutions 50 10/12/2015 Copyright © 2014 Siemens Industry, Inc.
STARTER
Setting the IP Address and PROFINET Name

1. Enter the IP Address (below) and Subnet mask


(255.255.255.0) in the circled field. Use the
Assign IP Configuration button, as indicated
by the red arrow, to apply your setting.

This step is only necessary for the SIMATIC


controller.
2. Enter the Device Name (below) in the circled
field. Use the Assign name button, as
indicated by red arrow, to apply the setting.

drive1 - 192.168.0.11 drive4 - 192.168.0.14

drive2 - 192.168.0.12 drive5 - 192.168.0.15

drive3 - 192.168.0.13 drive6 - 192.168.0.16

After setting the IP address and name, close the box


Best-in-Class and continue to the next page.
EtherNet/IP™
Solutions 51 10/12/2015 Copyright © 2014 Siemens Industry, Inc.
STARTER
Confirm the address settings

In the Accessible nodes box click on the Update button at the bottom-center of the window. After the
update has finished, you should see that the drive now has the assigned IP address and PROFINET name.
See the example below.

Best-in-Class
Continue to the next page
EtherNet/IP™
Solutions 52 10/12/2015 Copyright © 2014 Siemens Industry, Inc.
STARTER
Accepting the station

1. Check the box indicated by the arrow by simply clicking on it.


2. Press the Accept button. A progress bar will briefly appear.
3. Close the dialog box that confirms the transfer of the drive.
Continue to the next page

Best-in-Class
EtherNet/IP™
Solutions 53 10/12/2015 Copyright © 2014 Siemens Industry, Inc.
STARTER
Project Tree structure – Creating the station

Now you should see this file structure in the Project Tree.
The name of your drive station may differ from the one
shown here.

Best-in-Class
Continue to the next page
EtherNet/IP™
Solutions 54 10/12/2015 Copyright © 2014 Siemens Industry, Inc.
STARTER
Going online and uploading

1. On the Tool Bar locate 2. In some instances the Assign Target Devices window will appear.
and press the Connect If it does, simply press the Connect to assigned devices button at
to selected target the bottom of the window.
device button.
Continue to the next page

Best-in-Class
EtherNet/IP™
Solutions 55 10/12/2015 Copyright © 2014 Siemens Industry, Inc.
STARTER
Upload hardware configuration

Next you will upload the hardware configuration of the drive to the station in your project.
To do this, press the Load HW configuration to PG button.
Continue to the next page for additional instructions.

Best-in-Class
EtherNet/IP™
Solutions 56 10/12/2015 Copyright © 2014 Siemens Industry, Inc.
STARTER
Upload drive parameters

Next you will upload the drive parameterization to the station in your project.
To do this, press the Load to PG button.
Continue to the next page for additional instructions.

Notice the “Inconsistent” between


the Offline and Online

Best-in-Class
EtherNet/IP™
Solutions 57 10/12/2015 Copyright © 2014 Siemens Industry, Inc.
STARTER
Upload drive parameters

1. In the Load to PG dialog box select YES

2. When the uploading process has


finished, continue to the next page
for additional instructions.

Best-in-Class
EtherNet/IP™
Solutions 58 10/12/2015 Copyright © 2014 Siemens Industry, Inc.
STARTER
Upload complete

You have completed the uploading of the drive hardware configuration and
parameterization to the offline project. Notice the Offline and Online
configurations are now consistent.
Close the Online/Offline Comparison box and continue to the next page.

Notice the Offline and Online are no


longer “Inconsistent”.

Best-in-Class
EtherNet/IP™
Solutions 59 10/12/2015 Copyright © 2014 Siemens Industry, Inc.
STARTER
Saving the project

In a moment you will execute the Commissioning Wizard but first


you need to disconnect from the drive and save the project.
Follow the instructions below.

1. On the Tool Bar of STARTER, locate and


press the Disconnect from target system
button.

2. Save the project

Best-in-Class
EtherNet/IP™
Solutions 60 10/12/2015 Copyright © 2014 Siemens Industry, Inc.
STARTER
Commissioning Wizard

1. Open the Control Unit folder by clicking on the +

2. Double click on Configuration

3. Locate and press the Wizard


button in the Work area
Best-in-Class
Continue to the next page
EtherNet/IP™
Solutions 61 10/12/2015 Copyright © 2014 Siemens Industry, Inc.
STARTER
Commissioning Wizard
Control type

For the Control type select [20] Speed


control (encoderless)
Click Next and continue to the next page.

Best-in-Class
EtherNet/IP™
Solutions 62 10/12/2015 Copyright © 2014 Siemens Industry, Inc.
STARTER
Commissioning Wizard
I/O Configuration

No changes for the setpoint/command


sources.
Click Next and continue to the next page.

Best-in-Class
EtherNet/IP™
Solutions 63 10/12/2015 Copyright © 2014 Siemens Industry, Inc.
STARTER
Commissioning Wizard
Motor type

In the Drive setting screen select NEMA


motor (60Hz. SI units)
No changes for the Power unit
application
Click Next and continue to the next page.

Best-in-Class
EtherNet/IP™
Solutions 64 10/12/2015 Copyright © 2014 Siemens Industry, Inc.
STARTER
Commissioning Wizard
Motor type - Induction

For the Motor type select [1] Induction


motor as shown.
Click Next and continue to the next page.

Best-in-Class
EtherNet/IP™
Solutions 65 10/12/2015 Copyright © 2014 Siemens Industry, Inc.
STARTER
Commissioning Wizard
Motor data

230V Drives
• Rated motor voltage: 230
• Rated motor current: 0.73
• Rated motor power: 0.12
• Rated motor power factor: 0.75
• Rated motor frequency: 60.00
• Rated motor speed: 1650
• Motor cooling type: [0]

Best-in-Class
Continue to the next page
EtherNet/IP™
Solutions 66 10/12/2015 Copyright © 2014 Siemens Industry, Inc.
STARTER
Commissioning Wizard
Motor tuning

For the Motor identification select [2]


Identifying motor data (at standstill)
Click Next and continue to the next page.

Best-in-Class
EtherNet/IP™
Solutions 67 10/12/2015 Copyright © 2014 Siemens Industry, Inc.
STARTER
Commissioning Wizard
Ramp times

Set only the Ramp times as show by the


red arrows.

Click Next and continue to the next page.

Best-in-Class
EtherNet/IP™
Solutions 68 10/12/2015 Copyright © 2014 Siemens Industry, Inc.
STARTER
Commissioning Wizard
Motor parameter calculations

Select Complete calculation of the


motor parameters.
Click Next and continue to the next page.

Best-in-Class
EtherNet/IP™
Solutions 69 10/12/2015 Copyright © 2014 Siemens Industry, Inc.
STARTER
Commissioning Wizard – Finish

Press Finish and continue to the


next page.

Best-in-Class
EtherNet/IP™
Solutions 70 10/12/2015 Copyright © 2014 Siemens Industry, Inc.
STARTER
Changing the Field bus telegram

1. Open the Communication group by 2. Double click on Field bus


clicking on the +

Best-in-Class Continue to the next page


EtherNet/IP™
Solutions 71 10/12/2015 Copyright © 2014 Siemens Industry, Inc.
STARTER
Changing the Field bus telegram

After selecting the Field bus category, you will see several selection drop-downs for configuring the field bus.
In a moment you will be instructed to make some changes ONLY to the protocol selection and telegram configuration
but first notice that the Receive direction tab is probably already selected. (Circled in red) It is not necessary to make
these changes in both tabs. Changes to these two categories are copied automatically.
Starting with the Select field bus protocol, change only the fields indicated with red arrows to the setting as shown.

• SIEMENS standard telegram 352 is made up of 6 output words (Actual values, Alarms & Faults codes, Torque and
Current values) and 6 inputs words (Control and Setpoints).

NOTE: Regardless of the Telegram type selected, it is standard practice for the first two input words to be Control Word 1
and Speed Setpoint. It is also standard practice for the first two output words to be Status Word 1 and Speed Actual.

Best-in-Class Continue to the next page


EtherNet/IP™
Solutions 72 10/12/2015 Copyright © 2014 Siemens Industry, Inc.
What can you get with the different Telegrams?
(PROFINET or EtherNet/IP protocol)

Best-in-Class
EtherNet/IP™
Solutions 73 10/12/2015 Copyright © 2014 Siemens Industry, Inc.
STARTER
Saving and Downloading the project

1. Select Save project on the main menu.

2. On the Main menu press the Connect to selected target 1 2 4


device button.

3. Confirm you are online. The online status bar in the lower right
corner should say “Online Mode” in a yellow background.

4. Press the Load project to target device button to start the


file transfer. You must have the drive station selected in the
Project tree for this button to be active.

5. In the dialog box that opens, select YES to start the download.

6. When the download completes, click on the Alarm display tab


at the bottom left of the screen. This will reveal the alarm status
of the drive. Currently A07991 is active because the drive is
ready to perform a stand-still tune.

Continue to the next page.


Best-in-Class
EtherNet/IP™
Solutions 74 10/12/2015 Copyright © 2014 Siemens Industry, Inc.
STARTER
Motor ID – Standstill tune

In this step you will initiate the Motor Data ID, also called the stand-still tune. Please read the bullets below so
you will know what to expect while the tuning is active.

In just a moment you will be instructed to start the drive, when you do …

• You will hear the drive cooling fan running

• The motor shaft might rotate ¼ turn or less

• You will hear a series of high frequency rings from the motor while the Motor Data ID is in progress

In this lab P15 was not changed from the default value of 7 which means the drive is configured for field bus control.

You can utilize the HAND mode of the Intelligent Operator Panel (IOP) to initiate the Motor Data ID.

1. 1. Place the drive in HAND mode by pressing the HAND/AUTO button on the IOP. The hand icon will appear in the
top-right corner.

2. 2. Press the green ( I ) start button on the IOP to initiate the standstill tune.

How will you know it’s finished? The drive automatically goes to an “off” state and the cooling fan stops running.

Also, the A07991 alarm will clear from the list.

After the Motor ID has finished, place the drive back in AUTO mode by pressing the HAND/AUTO button on the IOP.
Ensure the hand icon has cleared from the IOP and continue to the next page.
Best-in-Class
EtherNet/IP™
Solutions 75 10/12/2015 Copyright © 2014 Siemens Industry, Inc.
STARTER
Commissioning is complete

Congratulations!
The commissioning is complete and the drive is
ready to be connected to the field bus controller.

By default the drive field bus protocol is set for ProfiNet; however, the EtherNet/IP protocol can be
selected with a simple change to parameter P2030. This can be done with STARTER or with the
drive operator panel.

If an EtherNet/IP controller is being used, jump forward to the following slide (“Field bus protocol –
EtherNet/IP”) for instructions on changing the protocol.

Best-in-Class
EtherNet/IP™
Solutions 76 10/12/2015 Copyright © 2014 Siemens Industry, Inc.
STARTER
Field bus protocol - EtherNet/IP

Instructions for changing the field bus protocol to EtherNet/IP.

Changes can be either made online with STARTER (next slide) or directly on the drive
via the Intelligent Operator Panel – IOP (two slides below).

Best-in-Class
EtherNet/IP™
Solutions 77 10/12/2015 Copyright © 2014 Siemens Industry, Inc.
STARTER
Field bus protocol - EtherNet/IP

Instructions for changing the field bus protocol to EtherNet/IP via STARTER.

1. Make sure you are online with the Drive.

2. In the Project tree, double click on Control Unit and then


double click on Expert List.

3. A list of parameter will become visible as shown below.


Select parameter P2030 and change it to [10] EtherNet/IP.

4. Select “Drive Unit_1” on the project tree, and click on the


“copy RAM to ROM” icon on the top menu (image below).

5. Check the IOP to see if the “floppy disk” is NOT present


(RAM to ROM finalized), then cycle power the drive either by:
- Turning the drive power switch OFF->ON; or
- Changing parameter P972 to [1].

• Copy RAM-to-ROM

Best-in-Class
EtherNet/IP™
Solutions 78 10/12/2015 Copyright © 2014 Siemens Industry, Inc.
STARTER
Field bus protocol - EtherNet/IP

Instructions for changing the field bus protocol to EtherNet/IP via operator panel (IOP).

1. Scroll the “OK” wheel to the right to highlight Menu. Press OK.

2. Scroll the wheel to highlight Parameters. Press OK.

3. Scroll the wheel to highlight Search by number. Press OK.

4. Scroll and press the wheel to enter 02030. Press OK.

5. Scroll the wheel to highlight [10] Ethernet/IP. Press OK.

6. Wait until the “floppy disk” on top of the screen goes away. If the
“floppy disk” does not go away after a few seconds, a RAM-to-ROM
copy is necessary.
- Press ESC 3x to go back to Menu.
- Scroll the wheel to highlight Extras. Press OK.
- Scroll the wheel to highlight Parameter settings. Press OK.
- Scroll the wheel to highlight Save RAM to ROM. Press OK.
- Press YES to save RAM to ROM and wait until it is completed.

8. Cycle power to the drive by either:


- Turning the drive power switch OFF->ON; or
- Changing parameter P00972 to [1].
Best-in-Class
EtherNet/IP™
Solutions 79 10/12/2015 Copyright © 2014 Siemens Industry, Inc.
STARTER

You have completed the STARTER Hands–on lab


We hope you found this lab informative

Thank you for your time!

Best-in-Class
EtherNet/IP™
Solutions 80 10/12/2015 Copyright © 2014 Siemens Industry, Inc.
Back From Hands On Lab

Best-in-Class
EtherNet/IP™
Solutions 81 10/12/2015 Copyright © 2014 Siemens Industry, Inc.
Marketing
Collateral &
Communications
Support Resources for EtherNet/IP
SINAMICS G120 Drives over EtherNet/IP communication

• How do Siemens drives connect easily to EtherNet/IP?

• Add-on Instruction • Standard Telegram

SINAMICS Inverters offer easy integration with AOI’s


Best-in-Class
EtherNet/IP™
Solutions 83 10/12/2015 Copyright © 2014 Siemens Industry, Inc.
What can you get with the different Telegrams?
(PROFINET or EtherNet/IP protocol)

Best-in-Class
EtherNet/IP™
Solutions 84 10/12/2015 Copyright © 2014 Siemens Industry, Inc.
Support Resources for EtherNet/IP
Programming Step by Step Videos

• Configure G120 on EtherNet/IP


• Import G120 Add-on Instruction
PLC • Program using Add-on Instruction

• Set IP address for G120 Drive Siemens Starter SW


• Upload G120 Drive to Offline Configuration
• Commission G120 Motor Data
Drive • Enable EtherNet/IP Protocol

• Verify Control Logix and G120 Drive


operation
Test
Best-in-Class
EtherNet/IP™
Solutions 85 10/12/2015 Copyright © 2014 Siemens Industry, Inc.
Support Resources for EtherNet/IP
what else?

• Add-On instruction (AOI) files

• EDS files

• HMI Tags and Videos

• Application Manuals

Check your Service & Support


website for the latest updates!
Best-in-Class
EtherNet/IP™
Solutions 94 10/12/2015 Copyright © 2014 Siemens Industry, Inc.
Best-In-Class Ethernet Solutions

• So why consider Siemens solution?

 ONE panel design – just swap processor to support both


EtherNet/IP or PROFINET!
 Comprehensive range of EtherNet/IP products to support
the entire solution
 Advanced network diagnostics – closer control of the
application
 Extended Safety Integrated Functions on both the General
Purpose and System drives
 Industry-leading components featuring state-of-the-art
technology with innovative features
 Global sales support and availability

Best-in-Class
EtherNet/IP™
Solutions 95 10/12/2015 Copyright © 2014 Siemens Industry, Inc.
THANK YOU!

A comprehensive and flexible solution


with “Best-in-Class” features

Best-in-Class
EtherNet/IP™
Solutions 96 10/12/2015 Copyright © 2014 Siemens Industry, Inc.

You might also like