You are on page 1of 68

We make

PROFINET better!
Components, systems,
and solutions
PHOENIX CONTACT –
in dialog with customers
and partners worldwide
Phoenix Contact is a global market leader Estonia

in the field of electrical engineering, Belarus

electronics, and automation. Founded in


1923, the family-owned company now
employs around 12,800 people Qatar

worldwide. A sales network with


over 50 sales subsidiaries and more
than 30 additional sales partners
guarantees customer proximity directly
on site, anywhere in the world.
Our range of services consists of products
surrounding various different electrotechnical
applications. This includes numerous
connection technologies for device
Global player with personal customer contact
manufacturers and machine building, Company independence is an integral part of
components for modern control cabinets, and our corporate policy. Phoenix Contact therefore
relies on in-house competence and expertise in
tailor-made solutions for many applications a range of contexts: the design and development
and industries, such as automobile departments constantly come up with innovative
product ideas, developing special solutions to
production, wind energy, photovoltaics, the meet customer requirements. Numerous patents
emphasize the fact that many of Phoenix Contact's
process industry or applications in the field of
products have been developed in-house.
water supply, power distribution, and traffic
infrastructure.

2 PHOENIX CONTACT

RZ_IE_Bro_TTSolutionCenter_Tele.indd 2 02.10.13 10:00


PROFINET with PHOENIX CONTACT

Phoenix Contact helped shape to PLCs. By developing our own


the trend towards Ethernet-based technology for ASICs, PROFINET
automation technology from an controllers or PROFIsafe we are
early stage. Our many years of able to be independent while still
expertise influence all our product ensuring full compatibility with the
developments, from connectors standard.

Contents

PROFINET technology
4/5
Coordinated solution concepts
Solutions for all aspects of
Based on controllers and software covering all aspects of PROFINET, PROFINET 6/7
expertise in terms of applications and technology is combined to create
tailor-made solution packages. Products for PROFINET
Controllers 8 - 13
Software PLC 14 / 15
PROFIsafe 16 / 17
SafetyBridge technology 18 / 19
PROFIenergy 20 /21
Extensive product portfolio
PROFINET system redundancy 22 - 25
From cabling and infrastructure to PLCs, Phoenix Contact offers Software 26 / 27
an unrivalled product portfolio for PROFINET. All components are I/O systems 28 - 31
perfectly coordinated and can be optimally integrated in other control Machine lights 32 / 33
platforms using the PROFINET standard. Proxies 34 / 35
PROFINET HMIs 36 / 37
Switches 38 - 43
Wireless 44 - 47
Security routers and firewalls 48 / 49
Media converters 50 / 51
Everything you need for device development
Isolators, patch panels 52 / 53
In order to integrate PROFINET in your devices, we provide support Surge protection 54 / 55
across all levels: with panel feed-throughs and plug technology for Data cabling 56 - 61
hardware developers and software and certification for firmware
developers. PROFINET expertise
Implementation 62 / 63
Testing 64 / 65
Competence from planning to operation
Service and support 66 / 67
Put our knowledge to good use in all engineering phases. Use our
training courses to enhance your own expertise. Your machines will run
smoothly and error-free.

PHOENIX CONTACT 3

10:00
PROFINET – flexibility is the
key for every application

PROFINET technology features


high-performance and compatible basic
architecture. Functional add-ons meet the
requirements of a wide range of sectors
and solutions.
IT functions complement the automation
technology functions – this enables
PROFINET devices and networks to be
optimally integrated into IT landscapes.

4 PHOENIX CONTACT
Broad market support Flexibility for a Increased efficiency due to
safeguards investments cost-optimized solution easy handling

PROFINET is the leading realtime Use the wide range of PROFINET Over the entire lifecycle of a system –
Ethernet system with the greatest functions in your automation task: from planning to operation – PROFINET
market relevance. From systems • TCP/IP communication is possible at all provides support with integrated
manufacturing near to the process to times functions:
special engineering/series production of • Excellent integration into the
• Redundant controllers or networks to
machines – all areas are addressed by the engineering chain, thanks to the GSD
increase availability
technology and the functions. file and a detailed device model
• Synchronous data exchange with IRT
Accordingly, many technology suppliers
for realtime communication with • Virtually infinite address area, limited
and device manufacturers cater for an
jitter < 1 μs only by the performance capability of
extensive product portfolio.
• In-depth safety integration in the same the controller
The PI Organization and the PROFINET
network, including over wireless paths • Fast startup, thanks to topology
Competence Center network offer
worldwide knowledge transfer. • Flexible diagnostics concept for detailed detection and easy device naming
device and network diagnostics • The network follows the system
structure, thanks to flexible cabling
with various media or even without
cables
• Consistent diagnostic functions
shorten startup and reduce downtimes

PHOENIX CONTACT 5
Solutions for all aspects of PROFINET

Products, sector-specific functions, and


block libraries plus coordinated software
provide the basis for industry solutions
from Phoenix Contact. With our expert
know-how for the relevant sectors,
Phoenix Contact provides support for
stand-alone solutions as well as complex
industrial systems.

Products Software
Everything from a single Engineering is key
source Phoenix Contact software and hardware
An extensive product portfolio are optimally coordinated. When used
offers proven and certified together, they offer solutions for all
hardware for all aspects of levels of an automation task while
PROFINET technology. simultaneously reducing the amount of
engineering involved.

6 PHOENIX CONTACT
Solutions Sectors
Tailored to your industry Controlling processes
Application-specific solution packages are created As an automation specialist with extensive knowledge
in cooperation with our customers and partners. of your sector, we integrate individual industry solutions
You can now benefit from the expertise gained as it based on PROFINET and merge them to form complete
provides the foundation for new innovations. processes. Phoenix Contact provides optimum support for
end users as well as system integrators.

PHOENIX CONTACT 7
Compact controllers

Compact controllers from Phoenix Contact


are ideal for use in PROFINET networks. In
their function here as a PROFINET device,
Standard PLC
they can provide a PROFINET master with
Axiocontrol
process data.
AXC 1050
Thanks to their programmability data can AXC 1050/XC
be preprocessed, thereby reducing the load High-performance PC WORX-programmable
compact controller for the Axioline I/O system
on the PROFINET master. Furthermore,
• Configurable PROFINET RT device
the compact controllers offer an integrated • Max. of 63 Axioline F I/O modules can be
web server that allows process data to be aligned
• Controlled program exit thanks to
displayed in a standard browser. integrated UPS
• XC version for extreme temperatures:
-40°C to +60°C

8 PHOENIX CONTACT
Standard PLC Standard PLC PLC for
Inline Inline machine building

ILC 131 ETH ILC 171 ETH 2TX ILC 191 ME/INC
ILC 131 ETH/XC ILC 191 ETH 2TX ILC 191 ME/AN
ILC 151 ETH
Version of the PC WORX-programmable Version of the PC WORX-programmable
ILC 151 ETH/XC
compact controllers in Inline format for compact controllers in Inline format with
Entry-level PC WORX-programmable networked stations functions for positioning tasks
compact controllers, for distributed remote • 2 Ethernet interfaces with integrated • Configurable PROFINET RT device
stations in Inline format switch • 3 additional INTERBUS remote bus
• Can be flexibly extended with up to • Configurable PROFINET RT device branches
4096 I/O points
• MRP redundancy client • 8 inputs / 4 outputs
• Configurable PROFINET RT device
• ILC 191 ETH 2TX version with integrated • 1 PWM output, 1 x RS-485
• XC versions for extreme temperatures: FPU (floating point unit) • 2 x AI / 2 x AO (/AN version)
-40°C to +60°C
• 2 x high-speed counter (/INC version)

PROFINET transforms the machine into a system module


Task Technology
In smaller machines and systems, the In terms of the engineering, complex
use of PROFINET may not always technology functions such as
be economically viable. These days, positioning, fast counters or the
however, it is expected that conveyor required mathematical functions
lines, lifting tables or grippers will be can be organized into subsystems.
integrated into an automation network. The autonomous units are even
integrated into a PROFINET network
Implementation
independently of the controller using a
PROFINET allows controllers to GSD file.
be cascaded, i.e., a controller can
simultaneously act as a device for a Summary
central control system. This means Acting as PROFINET devices, compact Controllers can simultaneously act as a device
that each controller can either be used controllers from Phoenix Contact for the central control system
stand-alone or as part of the overall can perform even sophisticated tasks.
ensemble. Technology functions can be Machine and system manufacturers are
outsourced to the subareas. therefore always on the safe side.

PHOENIX CONTACT 9
High-performance controllers

High-performance controllers from


Phoenix Contact are the reliable solution
for average to sophisticated automation
tasks. PROFINET supports flexible Your advantages with the
high-performance controllers
expansion with distributed I/Os. Connect Scalable – more interfaces, larger
the PLC flexibly to higher-level controllers memory, greater computing capacity
via the Ethernet ports, or integrate Flexible – can be extended with a wide
range of I/O modules; compatible blocks
lower-level devices with additional I/O simplify I/O access for the programmer
modules. Communicative – with Ethernet-
based protocols such as UDP, TCP,
SNMP, block-based FTP, plus integrated
drivers such as PROFINET controller,
PROFINET device, and Modbus/TCP
client, integrated web server

10 PHOENIX CONTACT
Axiocontrol PLC Standard PLC Advanced PLC

AXC 3050 ILC 330 PN ILC 370 PN 2TX-IB


ILC 350 PN ILC 370 PN 2TX-IB/M
PC WORX-programmable controller for the
ILC 390 PN 2TX-IB
Axioline I/O system PC WORX-programmable controller in Inline
• High-performance PROFINET RT format PC WORX-programmable controller in Inline
controller for up to 256 devices • High-performance PROFINET RT format, for larger volumes
• Configurable PROFINET RT device with up controller for up to 100 devices • High-performance PROFINET RT
to 512 bytes of data that can be exchanged • Configurable PROFINET RT device with up controller for up to 100 devices
• Can be extended with up to 63 I/O to 512 bytes of data that can be exchanged • Configurable PROFINET RT device with up
modules via the Axioline local bus • Can be flexibly extended with up to 4096 to 512 bytes of data that can be exchanged
• 3 Ethernet interfaces for web/FTP server, I/O points, locally or remotely via Inline • 2 Ethernet interfaces for web/FTP server,
open TCP/IP communication, OPC • Ethernet interface for web/FTP server, open TCP/IP communication, OPC
functionality open TCP/IP communication, OPC functionality
functionality • M version with approval for shipbuilding

PROFINET supplies drinking water to customers


Task communicate via Modbus/TCP in the
A newly built water treatment plant same network.
for a city in Turkey covers considerable Summary
distances in difficult terrain.
Thanks to the use of PROFINET,
Implementation a consistent architecture based on
The water is conveyed over a 35 km industrial Ethernet is ensured.
long pipeline from a reservoir in a
mountain region to the treatment
plant.
Technology
Several controllers are cascaded
Redundant network structure for safe drinking
together in a redundant network water supply
architecture. The three main
controllers are integrated into the
network as a PROFINET master and
PROFINET device. Below them are
additional compact controllers which

PHOENIX CONTACT 11
High-performance controllers

If your application places particular


requirements on controller performance,
the class 400 high-performance controllers
are the perfect solution, as they combine Your advantages with the
high-performance controllers
very high performance with an attractive Fast – maximum IEC 61131
price. performance even for sophisticated tasks
with up to 1 μs/1k instructions
In a PROFINET network, all high- Safe – integration of safety functions up
performance controllers act both as to SIL 3 in existing systems, thanks to
PROFIsafe
PROFINET controllers and as PROFINET Highly available – maximum
devices if required. The device can availability in critical processes, thanks to
PROFINET-based controller redundancy
therefore be configured on the same
Well-thought-out – fast startup and
interface or different interfaces. excellent diagnostics, thanks to high-
resolution display
This means that cascaded systems can be
implemented easily.

12 PHOENIX CONTACT
Basic PLC Safety PLC Redundant PLC

RFC 470 PN RFC 470S PN 3TX RFC 460R PN 3TX


PC WORX-programmable high-performance PC WORX-programmable high-performance PC WORX-programmable high-performance
controller for the most sophisticated safety controller redundancy controller
applications • High-performance PROFINET RT • High-performance PROFINET RT
• High-performance PROFINET RT controller for up to 256 devices controller for up to 256 devices
controller for up to 256 devices • Integrated PROFIsafe controller according • Maximum availability with AutoSync
• Configurable PROFINET RT device with up to SIL 3, Cat. 4, PLe controller redundancy
to 512 bytes of data that can be exchanged • Configurable PROFINET RT device with up • 3 Ethernet interfaces with 2 separate
• 3 Ethernet interfaces with 2 separate to 512 bytes of data that can be exchanged networks for web/FTP server, open TCP/IP
networks for web/FTP server, open TCP/IP • 3 Ethernet interfaces with 2 separate communication, OPC functionality
communication, OPC functionality networks for web/FTP server, open TCP/IP
communication, OPC functionality

PROFINET makes robots dance


Task Summary
The consistent use of PROFINET was Thanks to the use of PROFINET
required in a production plant for a technology, efficiency, profitability,
leading automobile manufacturer. The modularity, and standardization have
building automation of the production been increased.
plant is also based on PROFINET.
Implementation
Each production cell with 450 robots in
total and the conveying technology are
automated with PROFINET controllers.
Technology
Reliable and high-performance automation for
All IO devices and robots are robot cells
connected via PROFINET by the
RFC 470 controllers. Each PLC is
responsible for controlling different
parts of the conveying technology in its
respective sector as well as connecting
to the adjacent robot controllers.

PHOENIX CONTACT 13
Software PLC

Industrial PCs for visualization and


operation are often only utilized to a
limited extent. Make use of these available
resources and also transform your Your advantages with the
software PLC
industrial PC into a fully-fledged PLC. Robust – crash-proof, long-term stable
PC WORX SRT only makes low demands controller runtime, isolated from the
operating system
on the hardware profile and can therefore
Cost optimized – programming,
be installed on almost all Windows PCs – visualization, and control can be
making it ideal for small applications. performed on the same hardware
Communicative – PROFINET or
PC WORX RT BASIC offers the high Modbus via the Ethernet interface of
the PC, high-performance OPC server,
performance expected from a conventional integrated web server for local operating
PLC and is suitable for sophisticated tasks. and diagnostics concepts

14 PHOENIX CONTACT
Software PLC Software PLC Box PC

PC WORX SRT PC WORX RT BASIC VALUELINE IPC


Software PLC for installation on an industrial Realtime-capable software PLC for Thanks to their wide range of configuration
PC installation on an industrial PC options, Valueline box PCs and panel PCs
• PROFINET RT controller for up to 8 devices • PROFINET RT controller for up to are the ideal solution for numerous fields
256 devices of application. Fanless and designed without
• Configurable PROFINET RT device with up
rotating parts, they provide availability and
to 512 bytes of data that can be exchanged • Configurable PROFINET RT device with up
durability. The maintenance-friendly design
• Visualization, data processing or data to 512 bytes of data that can be exchanged
enables quick and easy access to important
storage run parallel on the same hardware • Visualization, data processing or data components such as the hard disk.
storage run parallel on the same hardware

Installation transforms the IPC into a controller


The installation of the
PC WORX RT BASIC software PLC
transforms the industrial PC into
a fully-fledged controller in just a
few minutes. A realtime extension
is added to the standard operating
system. The actual software PLC then
operates in this realtime environment.
The extension shields the control
application from the Windows world
in such a way that the integrity and the
deterministic behavior of the software
PLC are ensured.
With a multi-core processor, one
processor core is used exclusively
for the software PLC. This offers Shielded and immune to interference: the realtime extension with the control application
additional protection for the control
application. PC WORX RT BASIC uses a standard
The software PLC supports Ethernet interface of the IPC to
PROFINET, Modbus/TCP, and the communicate with the installed I/O
proven INTERBUS system. modules via PROFINET.

PHOENIX CONTACT 15
PROFIsafe

A wide range of safety functions, high


numbers of I/Os, and large networks –
play it safe even in sophisticated automation
Safety controller
systems with high-performance safety
components from Phoenix Contact.
RFC 470S PN 3TX
Reliably integrate functional safety into
PC WORX and SafetyProg-programmable
PROFINET networks. safety controller
• Integrated PROFIsafe controller according
to SIL 3, Cat. 4, PLe
• High-performance PROFINET RT
controller for up to 256 devices
• Configurable PROFINET RT device with up
to 512 bytes of data that can be exchanged

Services for your


machine safety
Detailed consulting
Consultation to clarify your specific
requirements with regard to the
measures required for machine safety

Presentation
• Process assistance for practical
on-site implementation
• Templates for verification
documentation

16 PHOENIX CONTACT
Safety programming PROFIsafe gateway Safety I/O modules

SAFETYPROG – BASIC FL PN/PN SDIO-2TX/2TX IB IL 24 PSDI 8-PAC


SAFETYPROG – ADVANCED IB IL 24 PSDO 8-PAC
Industrial gateway for connecting two safe
SAFETYPROG – PROFESSIONAL IB IL 24 PSDO 4/4-PAC
PROFINET systems
IB IL 24 PSDI 16-PAC
Safety programming system for developing • Coupling of safe and standard I/O data IB IL 24 PSDOR 4-PAC
safe applications for all aspects of safety
• Redundant power supply
controllers Safety I/O modules
• Control-independent
• Based on standard IEC 61131-3 and meets • Flexible use in PROFINET or PROFIBUS by
the safety requirements defined in adapting the bus terminal
IEC 61508 • Single or two-channel sensor and actuator
connection
• PSDOR version with relay outputs

Safety engineering Safety service Safety training


• Assessing safety integrity Free safety technology hotline with • Machinery Directive
• Safety specifications for machinery 24-hour product support • EN ISO 13849-1
• Programming the safety controller + 49 5281 9-462777 • Machine safety practical workshop
• Creating safe functional blocks • Safety lifecycle practical workshop
On-site service for:
• Verifying verification documentation • SISTEMA
• Installation
• Validating safety functions • Safety technology basics
• Startup
• INTERBUS-Safety
• Operation
• PROFIsafe
• Individual seminars and workshops

PHOENIX CONTACT 17
SafetyBridge technology

In your PROFINET network, SafetyBridge


I/Os perform the relevant safety tasks and
quickly and easily integrate functional safety
into your machine or system. You do not What are the advantages of
independence from the network?
require a safety controller for this, you can SafetyBridge technology can be
still use your preferred standard controller. integrated extremely easily into
PROFINET and all popular fieldbus and
SafetyBridge technology offers very flexible Ethernet-based networks.
and cost-effective safety solutions and Continue to benefit from the advantages
of your preferred network solution. No
supports a virtually unlimited range of additional safety networks are required,
possible applications. which saves you time and money
during the design of your machines and
systems.

18 PHOENIX CONTACT
Logic modules Input and output modules Configuration software

IB IL 24 LPSDO 8 V2-PAC IB IL 24 PSDI 16-PAC SAFECONF


IB IL 24 LPSDO 8 V3-PAC IB IL 24 PSDI 8-PAC
The free configuration software for
IB IL 24 PSDO 8-PAC
The SafetyBridge logic modules generate SafetyBridge modules enables the quick
IB IL 24 PSDOR 4-PAC
and monitor the SafetyBridge protocol and configuration of safety functions using
IB IL 24 PSDO 4/4-PAC
process the safety program drag & drop.
• V2 version can be linked to up to 5 safe The SafetyBridge I/O modules can be freely Download at: phoenixcontact.com
input or output modules distributed in the network. The safe I/O
modules acquire and output signals. They
• V3 version can be linked to up to 16
communicate with the logic module via the
safe input or output modules and cross
network and the controller.
communication is supported

Safe Metro transport with PROFINET


Task The solution: SafetyBridge technology
Barcelona's Metro system was with PROFINET. In addition to standard
extended with a line to the signals, safe signals are also transmitted
international airport. In this system via PROFINET.
there is just one tunnel tube with one Summary
platform on top of the other.
Using PROFINET and SafetyBridge
Implementation technology allowed the gate
One condition imposed was the suppliers to implement the relevant
implementation of valid safety requirements in a simple and cost-
standards. Particularly with regard to effective way.
the heavy 6-ton safety gates which
act as air locks in the event of an Maximum safety even over large distances
emergency.
Technology
Due to the distance involved (> 1200 m)
safety relays were not an option and a
safety controller was too expensive.

PHOENIX CONTACT 19
PROFIenergy

Electricity costs have risen continuously in


recent years and are also set to increase
further in future due to the scarcity of
primary sources of energy. This cost Flexible energy management
The PROFIenergy profile uses standard
increase affects the manufacturing industry PROFINET communication for an acyclic
in particular. As a result, the search is on communication protocol. Up-to-date,
standardized consumption values can be
for ways in which to reduce consumption read at any time – even from other
significantly. controllers – or the corresponding
PROFIenergy device can be switched to
PROFIenergy offers a flexible way of setting various energy-saving modes.
devices to ready-to-operate energy-saving It is only by correlating the consumption
values with the operating states that an
mode and then reactivating them. optimum energy-saving concept can be
defined. Provided the termination
devices support WakeOnLAN,
consumption can be reduced to just a
few watts.

20 PHOENIX CONTACT
PROFIenergy PLC PROFIenergy switches

Class 300 ILC controllers FL SWITCH GHS 12G/8


Class 400 RFC controllers FL SWITCH GHS 4G/12
PC WORX RT BASIC
Gigabit-capable high-performance managed
The controllers with IO controller function switch
support the PROFIenergy profile via IEC 61131 • Modular expansion possible
blocks. Connected PROFIenergy-compatible
• PROFINET RT device according to
devices can therefore be switched to energy-
conformance class B
saving mode or read energy values in a
targeted way. • Power consumption of the switch can be
reduced with PROFIenergy
• Integrated PROFINET diagnostics and
access via standardized IT protocols

Energy-efficient production with PROFINET


Task and infrastructure switches, the
In addition to ever growing demands on process devices are switched off during
the number of cycles and engineering breaks in work and energy is saved.
functions, electrical energy costs need The devices can even “go to sleep”
to be reduced in these same systems. automatically if required.
Implementation Summary
Even during a break in work a robot Costs can be reduced significantly
still consumes 40% of its energy in production plants by using
requirement. In some cases these PROFIenergy components.
breaks are several minutes long and
so it is important that energy-draining
process devices are switched to Keep resource consumption in check and save
standby mode during breaks in work, costs – with PROFIenergy
particularly in the automotive body
shop.
Technology
The PROFIenergy protocol is a sub-
discipline of the PROFINET standard.
With the aid of intelligent controllers

PHOENIX CONTACT 21
PROFINET system redundancy

Increase your system availability – with


Phoenix Contact technology for redundant
systems. Communication between the
controller and I/O devices is based on AutoSync technology
• Unique AutoSync technology
system redundancy according to the valid configures all redundancy functions
PROFINET standard and uses familiar automatically.
network redundancy mechanisms such as • The pair of controllers is programmed
on just one controller and one IP
MRP. address. Program and status data is
then transmitted in a fully automated
Redundant Ethernet networks are already way. If required, the pair of controllers
frequently used in industry. With redundant can be visualized redundantly with just
one OPC server.
controllers and redundancy-capable devices,
• The fiber optic cables between the
you can extend your machines and systems controllers can be up to 80 km long.
to create high-availability systems. And all This record distance is suitable for
traffic infrastructure, pipelines, mining,
this without any expert knowledge being etc.
required.

22 PHOENIX CONTACT
Redundant controller Redundancy-capable Switches for
devices redundant networks

RFC 460R IL PN BK DI8 DO4-2TX-PAC FL SWITCH GHS 12G/8


AXL E PN BK FL SWITCH GHS 4G/12
PC WORX-programmable high-performance
PLC with integrated redundancy function System redundancy-capable bus terminals for FL SWITCH GHS high-performance
• Easy startup and automatic configuration the Inline and Axioline I/O system Gigabit switch range
of all redundancy functions, thanks to • PROFINET RT device according to • PROFINET RT device according to
AutoSync technology conformance class B conformance class B
• Scalable fiber optic plug-in connections, • 2 Ethernet ports for the easy creation of • MRP manager and client for fast ring
depending on the distance line and ring topologies redundancy switch-over
• Uninterrupted process in the event of • MRP client function • Integrated PROFINET diagnostics and
failure or when a controller is replaced access via standardized IT protocols

Light in the tunnel with PROFINET


Task which is likewise redundant, supplies all
A revolutionary lighting concept is used the data to the control system.
in the construction of a new tunnel. Summary
The manufacturer of the LED lamps
The consistent PROFINET system
and signal generators guarantees a
allows for all variants of the tunnel
service life of at least 25 years.
lighting. This means, for example, that
Implementation the lighting can be freely dimmed or
The components for lighting, traffic sections of lighting can be switched
control, and emergency equipment off during the night. The durable LED
are not just failsafe, they are also technology and the high availability
exceptionally durable. All termination of the PROFINET system will reduce
devices are redundantly integrated into operating costs significantly over time. Failsafe tunnel lighting thanks to
a PROFINET system. AutoSync technology

Technology
Two redundant pairs of controllers
with PROFINET redundancy and
AutoSync technology communicate
with the configured PROFINET devices
in a network ring. An OPC server,

PHOENIX CONTACT 23
PROFINET system redundancy

System redundancy from Phoenix Contact


is characterized by its easy installation
and startup, together with high-availability
operation. Single point of failure redundancy Areas of application and
applications
is achieved by the systemic properties of • Rolling mills
the components, without the need for any • Tunnel applications
complex measures. A simple topology is (lighting, tunnel boring)
• Fire extinguishing equipment
made possible by the optimum interaction of
• Storage systems
network technology and PROFINET devices. • Alarm and monitoring systems on ships
Moreover, the redundant controllers are • Airport lighting systems
configured without any additional costs or • Fueling systems
• Dosing and mixing systems
engineering measures. Here simplicity and
• Access control
high availability are combined!

24 PHOENIX CONTACT
Controller Controller
MRP (Media Redundancy Protocol)
Switch and Switch and
MRP manager MRP client Redundant ring topology, standardized
according to IEC 62439 “High availability
automation networks”. MRP is part of
PROFINET standard IEC 61158 and
guarantees fast switch-over times.
In a network with a ring topology, the
Standby cable
in case of need MRP manager disables a port so that
the ring is only interrupted logically.
Device Device Data is sent in the network and the
MRP manager sends test telegrams
permanently via the logically disabled
port. In the event of an error, this port
MRP ring
is enabled for data telegrams.
Subcontroller
as PN device Device

Cruising with PROFINET


Task bus coupler and thereby represent the
Increasingly modern fire extinguishing device station.
systems are used in the latest Summary
generations of cruise ships. All the
The outstanding diagnostic properties
systems must be highly available with
and integrated MRP client functionality
minimum hardware and cabling effort.
in the PROFINET devices aid lean
Implementation cabling and efficient error analysis,
The redundant controllers monitor which is particularly important on
the components of a system. The board.
PROFINET devices are grouped in a
single ring over nine decks.
Reduced cabling effort for automation in
Technology
shipbuilding
The biggest challenge is monitoring the
flow monitors and the pump drives of
this equipment. Reliable operation must
be ensured in case of need. The Inline
automation kit from Phoenix Contact
contains suitable products which can
be easily connected to the PROFINET

PHOENIX CONTACT 25
Software

Phoenix Contact offers software from


configuration to system operation.
All products interact perfectly and impress
with their innovative functions and intuitive, PROFINET engineering
Consistent engineering solution –
user-friendly operation. as a user, first carry out planning
and configuration in PC WORX or
PROFINET, PROFIBUS, PROFIenergy, and SafetyProg. For startup, the tools offer
PROFIsafe are therefore always deeply consistent functions such as device
naming or topology detection. The tools
integrated into the software. Third-party already include functional blocks with
devices and proprietary products are pre-certified functions or functional
blocks for diagnostics.
equally well supported.
Fast error localization –
Diag+ provides PROFINET functions
with path-specific network diagnostics
or device-specific alarm texts.
SNMP-based tools are also available for
comprehensive diagnostics between IT
and automation levels.

26 PHOENIX CONTACT
Programming Safety programming

PC WORX SAFETYPROG SAFECONF


Software for programming and startup, from An IEC 61508-certified programming The free configuration software for
compact controllers to redundancy systems environment for PROFIsafe-compatible SafetyBridge modules enables the easy
• Programming according to IEC 61131 with controllers from Phoenix Contact configuration of safety functions using
comprehensive function libraries • Application-related programming according drag & drop (see also page 18/19).
• Online monitoring, debugging, and detailed to IEC 61131-3 Download at: phoenixcontact.com
project comparison • Pre-certified safety blocks for many safety
• Network and station configuration for functions available in a PLCopen library
PROFINET and INTERBUS • See also page 16/17

PLC/PROFINET diagnostics SNMP network diagnostics SNMP HMI integration

DIAG+ FL VIEW FL SNMP OPC SERVER


Diagnostic tool for troubleshooting and SNMP-based diagnostic tool Mapping of SNMP items to OPC objects for
system monitoring of networks with • Automatic detection and clear easy integration of the PROFINET/Ethernet
PC WORX-configured controllers representation of the network topology infrastructure in visualization systems
• System downtimes are avoided, thanks to • Trend function for long-term monitoring • Easy assignment of MIBs
precise topology-based representation • Defined selection of items
• Proactive response due to threshold value
• Advanced diagnostics concepts monitoring • Easy device integration, thanks to
• Reliable diagnosis of device and network • Events at a glance with event log function ready-made profiles
errors • Easy integration of traps and
alarms

PHOENIX CONTACT 27
I/O systems for the control cabinet

Whether modular or compact, in the


control cabinet or terminal box – thanks
to advanced I/O devices, communication
is fast and cost-effective. In addition to Your advantages with Axioline F
Fast – transmits data in realtime from
PROFINET, automation solutions from the I/O level to the controller. The
Phoenix Contact cover many common bus result: high measuring accuracy, lower
cycle times, better control quality,
systems and networks. thanks to extremely short response
times.
Thanks to the modular engineering of
Robust – thanks to the excellent EMC
PROFINET, the bus terminals and I/O design and shock-tested housing
modules are optimally integrated into the Easy – thanks to plug-in electronics and
push-in connection technology
configuration and diagnostics concept using
any controller.

28 PHOENIX CONTACT
Axioline F bus coupler Inline bus coupler

AXL BK PN IL PN BK DI8 DO4-2TX-PAC


IL PN BK DI8 DO4 2TX-SCRJ-PAC
The robust Axioline F bus coupler
communicates with the controller in realtime The Inline bus coupler enables the easy
• Can be extended with up to 63 modules, migration of existing system concepts by
e.g., digital, analog, temperature recording, replacing the bus terminal
communication modules • Can be extended with up to 63 modules,
• High packing density and easy to connect, e.g., digital, analog, temperature recording,
thanks to push-in technology communication modules
• PROFINET device for RT/IRT according to • PROFINET RT device according to
conformance class B/C conformance class B
• MRP client redundancy function • MRP client redundancy function

Minimize downtimes with PROFINET


Task ports on the controller where this
In machine building and systems information is stored. In the event of
manufacturing, it is not possible for device replacement, this information is
qualified personnel to be on hand at all used to start up the I/O station.
times for applications operated in areas Summary
that are difficult to access.
In addition to outstanding diagnostic
Implementation properties, the PROFINET devices
All PROFINET devices from offer service functions that have been
Phoenix Contact support tool-free integrated into the devices based
device replacement. This means that on decades of experience in fieldbus
in the event of a possible error at systems.
an I/O module, the module can be Tool-free device replacement and outstanding
replaced without specialist knowledge diagnostic properties thanks to PROFINET
and the system starts up the module
automatically.
Technology
The networked devices supply
information from connected
neighboring devices to the PROFINET

PHOENIX CONTACT 29
I/O systems for field installation

Acquire input and output data


directly in your systems and machines.
Phoenix Contact offers a wide range of I/O
devices with IP65/IP67 protection suitable Your advantages with Axioline E
Fast – reduced installation time, thanks
for every use. to SPEEDCON rapid interlock system
Thanks to standard PROFINET mechanisms Robust – vibration and shock-proof
housing enables use under adverse
such as topology detection and port-specific conditions
diagnostics, even distributed field devices Easy – color coding of functions and
can be easily installed and diagnosed in your M12 power simplify startup. Clearly
assigned signals facilitate diagnostics
automation solution. directly at the slot.

30 PHOENIX CONTACT
Axioline E Axioline E IO-Link/ Fieldline Modular
analog converters

AXL E PN ... AXL E IOL ... FLM BK PN M12 DI 8 M12-2TX


I/O range with a block design for field IO-Link/analog converters for the acquisition Bus coupler for the Fieldline Modular I/O
installation in IP65/IP67 and output of analog signals system
• Plastic or metal version • Analog input for current • Can be extended with up to 16 devices for
• Extensive product portfolio with digital • Analog input for voltage digital input/output, analog input/output,
input/output, analog input/output, and temperature recording or IO-Link master
• Temperature input
temperature recording with IO-Link • 2 Ethernet ports in M12 connection
• Analog output for current
master in combination with IO-Link/analog technology
converter • Analog output for voltage
• PROFINET RT device according to
• 2 Ethernet ports • IP65/IP67 protection conformance class B
• PROFINET RT device according to • IO-Link specification 1.1 • MRP client redundancy function
conformance class B
• MRP client redundancy function
• Shared device and fast startup (FSU)

One device,
numerous possibilities A
in

3/h

/s

3
/m

1
3
Nm

Nm

Nm

SP

SP
°C

10
Nl

ETH 1 ETH 2
LNK LNK

Together with the IO-Link/analog


Mode / Enter Set

D-32825 Blomberg
ACT
X21
ACT
X22
AI
converters, the Axioline E IO-Link
www.phoenixcontact.com
RDY BF SF

Ord.No.: 2700704
Id.-Nr.: PSK AFS6050IOL
Made in Germany

OU2: 1 L+
switch 2
OU1:
switch/
3
PWR IN PWR OUT
US
4

A
impulse L–

master enables flexible processing of


OU2: 1 L+
switch 2
OU1: 3
I

AO
switch/
4
impulse L–
IND. CONT.

UA
EQ 11 MA

E174189
X31 X32

signals in field installation. Conversion


U: 18...30 V IP 65
I OUT : < 250 mA
AA K12

of analog signals directly at the


30 31
X01 X02

D D A

measurement location and digital DI


32 33
X03 X04

transmission via unshielded cables UA


X05
UA
X06 TEMP
simplify installation. In addition, they DO
D

UA UA
X07 X08

result in interference-free measured


value transmission.
The Axioline E IO-Link master is very Interference-free and flexible: signal processing via IO-Link
versatile. The following functions can
be used by using the various operating • IO-Link device communication
modes of an IO-Link port: (e.g., flow sensors, valve islands,
photoelectric barriers or distance
• Digital standard signals
meters)
• Analog signals (in combination with
the IO-Link/analog convertors)

PHOENIX CONTACT 31
Machine lights

Make the most of your machine lighting:


with PLD machine lights, you can benefit
from all the advantages of LED technology
PLD communication
and save additional material costs and
module, PROFINET
installation time.
PLD CM 360 PN
Thanks to the use of a communication
PROFINET communication module for a
interface, PLD machine lights create brand modular lighting system
new possibilities, thereby increasing the • 2 PWM outputs for controlling the PLD
machine lights
efficiency of your machine. Integrate your • 1 digital input for error messages from the
machine lighting in your PROFINET network controlled lights
• IP67 protection
and control the lights directly via the PLD • 2 ports in M12 connection technology
communication module. • PROFINET RT device according to
conformance class B

Your advantages with


PLD machine lights
• No-load switching saves on additional
components
• Thanks to flashing mode, fast processes can
be monitored easily and inexpensively
• Continuous dimming offers customized light
settings
• Error messages and diagnostic information
increase machine availability
• The optics prevent glare for the machine
operator
• Series connections with the SPEEDCON
M12 rapid interlock system save cabling time
and material

32 PHOENIX CONTACT
PLD machine light, PLD machine light, PLD machine light,
200 mm 365 mm 695 mm

PLD M 360 W-50 200 PLD M 360 W-50 365 PLD M 360 W-50 695
50° emission angle 50° emission angle 50° emission angle
PLD M 360 W-100 200 PLD M 360 W-100 365 PLD M 360 W-100 695
100° emission angle 100° emission angle 100° emission angle
• 24 V DC supply voltage • 24 V DC supply voltage • 24 V DC supply voltage
• 5000 K color temperature • 5000 K color temperature • 5000 K color temperature
• LED service life of at least 65,000 hours • LED service life of at least 65,000 hours • LED service life of at least 65,000 hours
• IP67 protection • IP67 protection • IP67 protection

Custom machine lighting thanks to PROFINET


Task operation. The flashing mode enables
Users are increasingly using PROFINET easy monitoring of fast processes.
as the central communication medium Technology
in their machines and systems.
The PLD communication module
Increasingly, machine lighting has to be
enables the machine lights to
integrated into these systems so that
be integrated directly into the
it can be customized according to the
communication network as a
application.
PROFINET device and controlled via
Implementation the PROFINET controller.
Depending on the machine type, Summary
product or step, various demands are
Integrating the machine lighting
placed on the lighting of a machine. Situation-specific lighting – with intelligent
in PROFINET creates brand new
Thanks to their PROFINET connection, machine lights
possibilities for industrial lighting.
PLD machine lights can be adapted
quickly according to the specific
situation. For example, a high level
of illumination can be provided for
maintenance, while energy-efficient
light settings are sufficient for

PHOENIX CONTACT 33
Proxies

PROFINET is characterized by its subsystems


which can be integrated into a consistent
communication and diagnostics concept via a
proxy. Based on the standardized PROFINET Your advantages with the proxies
Consistent handling – supports the
specification, the user can access all field value-added chain in configuration,
devices. There is no duplicate configuration operation, and diagnostics since
configuration and diagnostics are carried
or addressing on the controller and proxy out completely via PROFINET functions
side. Data exchange, diagnostics, and Investment security – existing
parameterization of the proxy are carried system concepts, even those with large
INTERBUS or PROFIBUS networks, can
out via the PROFINET protocol. Older easily cross over into the PROFINET
systems or subsegments, in which Ethernet world

communication is not advantageous, can


be integrated into the PROFINET network
without any loss of information.

34 PHOENIX CONTACT
INTERBUS subsystem INTERBUS subsystem PROFIBUS subsystem
(FO)

FL NP PND-4TX IB FL NP PND-4TX IB-LK FL NP PND-4TX PB


Fully-fledged INTERBUS master as a Fully-fledged INTERBUS master as a Fully-fledged PROFIBUS master as a
PROFINET proxy PROFINET proxy PROFINET proxy for connecting any
• PROFINET RT device according to • PROFINET RT device according to PROFIBUS devices in PC WORX-based
conformance class B conformance class B applications
• MRP client redundancy function • MRP client redundancy function • PROFINET RT device according to
conformance class B
• 4 switched ports in RJ45 format for line or • 4 switched ports in RJ45 format for line or
star topology star topology • MRP client redundancy function
• INTERBUS master for up to 512 devices • INTERBUS master for up to 512 devices • 4 switched ports in RJ45 format for line or
with remote bus interface in optically star topology
regulated fiber optic path • PROFIBUS master DP V1 for a maximum
of 126 devices with up to 12 Mbps

Safe take-off and landing with PROFINET


Task installed at the gateways via two paths.
In order to increase the safety and Summary
therefore the availability of runway
The ideal solution was found with
lighting, the PC-based control system
the aid of redundant PROFINET
was extended by one level.
controllers, PROFINET-to-PROFIBUS
Implementation gateways, and IEC 61870-5-104
As a result of growing air traffic, the communication in the control system.
availability of take-off and landing strips The next step should follow with
is of fundamental importance. Just as the integration of PROFINET in the
important is the continuous monitoring termination devices.
of the function of all components used.
Reliable control and monitoring of
Technology
lighting systems
The existing control system has
been extended with two redundant
PROFINET controllers which
communicate in the network with
gateways. The light beacon elements,
such as controllers and the flashlight
and uninterruptable power supply are

PHOENIX CONTACT 35
PROFINET HMIs

A significant advantage of PROFINET is its


ability to process conventional protocols
transparently in addition to data packets
for PROFINET communication. This Your advantages with
PROFINET-compatible HMIs
means that components for operation and Easy – the HMIs are connected to the
monitoring can also be connected easily network via the Ethernet interface.
They can be managed by the controller
in the PROFINET network and without as PROFINET devices and get their IP
the need for expensive converters. The address, for example, from the project.
PROFINET device functions of the HMIs Flexible – the devices can be integrated
at any point in the network. In addition,
and the visualization data are transmitted the number of stations for local
using just one medium. visualization is only limited by the OPC
server used.
Well-thought-out – the devices
are actively identified in the topology
representation via SNMP or PDev and
errors are detected at every point in the
system

36 PHOENIX CONTACT
TP 3000 series TP 5000 series VISU+

TP 3000 TP 5000 VISU+ 2


HMIs with integrated PROFINET stack for HMIs with integrated PROFINET stack for The VISU+ software is a SCADA visualization
standard visualization tasks high-end visualizations with data connection to the controller. In
• Integrated PROFINET stack • Integrated PROFINET stack addition to standard functions for operation
and monitoring, trend representation, and
• Conformance class B • Conformance class B
alarm handling, the tool also offers functions
• Active PROFINET connection monitoring • Active PROFINET connection monitoring for production data acquisition, logging, and
• IP address assignment via DCP • IP address assignment via DCP connection to database and ERP systems.

More at a glance with PROFINET


Task Summary
A large conveyor system covers several Various panels are positioned along
production halls and is controlled the conveyor line, which transmit
centrally by a PROFINET controller. information to employees – saving the
inconvenience of referring to a central
Implementation
visualization monitor.
To some extent, employees manually
interact with the system and the
conveyed goods at several points along
the line. Emergency stops must be
visualized accordingly.
Technology
Intelligent access management in large and
Access management can be achieved confusing systems
thanks to the logic operations of the
OPC and PROFINET variables used
in the control program. This means
that entries can be checked based on
access rights and the physical position
of the HMI so as to prevent incorrect
operation.

PHOENIX CONTACT 37
Switches

For lean PROFINET networks, the focus


is on reliable and cost-effective realtime
operation. In addition to the integrated
Standard switch, IP67
switches in the PROFINET devices, a wide
range of infrastructure components are
available for creating PROFINET networks. FL SWITCH 1605 M12
Thanks to its wide temperature range and
The conformance class A switches high degree of protection, the IP67 switch is
suitable for a wide range of tasks outside the
support the minimum requirements of the control cabinet
PROFINET specification. • Unmanaged switch according to
conformance class A
The compact, machine-mountable IP67 • 5 ports with M12 connection technology
switches can be installed directly in the
field.

Your advantages with


Lean Managed Switches
Reliable – all switches support
the Rapid Spanning Tree algorithm
which allows redundant network
topologies
Easy – the devices can be easily
configured, thanks to the reduced
management functions
Flexible – ideal for networking
compact units. The extended
temperature range and the
numerous interface versions enable
universal use.

38 PHOENIX CONTACT
Lean Managed Switch, Lean Managed Switch, Lean Managed Switch,
copper 1 FO 2 FO

FL SWITCH LM 5TX FL SWITCH LM 4TX/1FX FL SWITCH LM 4TX/2FX


FL SWITCH LM 8TX FL SWITCH LM 4TX/1FX SM
Versions of the Lean Managed Switch range
FL SWITCH LM 8TX-B FL SWITCH LM 4TX/1FX ST
with two fiber optic interfaces for flexible
FL SWITCH LM 4TX/1FX SM ST
Copper versions of the Lean Managed Switch topologies
range for networking compact units Versions of the Lean Managed Switch range • Managed switch according to conformance
• Managed switch according to conformance with one fiber optic interface for integrating class A
class A individual remote stations
• 4 ports in RJ45 format
• 5/8 ports in RJ45 format • Managed switch according to conformance
• 2 ports in FX format for various fiber optic
class A
• RSTP redundancy function plugs and cable versions
• 4 ports in RJ45 format
• RSTP redundancy function
• 1 port in FX format for various fiber optic
plugs and cable versions
• RSTP redundancy function

Lean PROFINET networks


Task switches are integrated in the parking
The automation of parking garages garage management system in order to
requires a lean network with maximum detect errors and rectify them quickly.
availability because, just like in a Summary
production system, it really costs
The switches with SNMP support
money if a space cannot be utilized.
and redundancy mechanisms provide
Implementation the platform for fast and available
A PROFINET controller, which controls PROFINET communication between
the numerous distributed bus couplers, the controller and the distributed
is used to monitor the parking spaces. devices.
Information regarding the status of
parking spaces directs the flow of Monitoring of parking garages with lean
vehicle traffic inside the parking garage. networks and fast detection of errors

Technology
An available network is essential for
smooth operation in this application.
The reconfiguration times of the
switches in the event of a connection
error are less important, however the

PHOENIX CONTACT 39
Managed switches

Increase the productivity of your machines


and systems and ensure fast and consistent
information flow. Phoenix Contact offers
innovative Smart Managed Switches tailored Your advantages with managed
switches
to your system. Easy – PROFINET operating mode
set via the SMART mode button,
The industrial DIN rail switches support device replacement without specialist
Fast Ethernet or Gigabit on all ports knowledge thanks to local memory,
monitoring and configuration of switch
and are ideal for use in the PROFINET functions in web-based management
RT environment. At the same time, they In-depth PROFINET integration –
provide the bandwidth required for the MRP support for guaranteed, fast switch-
over times, PROFINET device functions
integration of IT realtime services, such for consistent configuration, fast startup,
as video or Voice-over-IP in automation and improved error diagnostics
IT acceptance – thanks to the
networks. supported standard protocols, the
switches are suitable for automation
tasks as well as IT installations

40 PHOENIX CONTACT
Smart Managed Switch Smart Managed Switch Gigabit Modular Switch

FL SWITCH SMCS 8TX-PN FL SWITCH SMCS 16TX FL SWITCH GHS 4G/12


FL SWITCH SMCS 8GT FL SWITCH SMCS 14TX/2FX FL SWITCH GHS 12G/8
FL SWITCH SMCS 6TX/2SFP FL SWITCH SMCS 14TX/2FX-SM
Switches in the GHS range have been
FL SWITCH SMCS 6GT/2SFP
The Smart Managed Switches with 16 ports developed for use in the production
FL SWITCH SMN 6TX/2POF-PN
consolidate all paths at central points in the backbone
FL SWITCH SMN 8TX-PN
automation solution • PROFINET RT device according to
Switches for networking application islands • PROFINET RT device according to conformance class B
with the higher-level backbone network, conformance class B • Up to 12 Gigabit ports, including up to
with optional Gigabit function and fiber optic
• Optional MRP manager function 4 with SFP
interfaces
• Various IT management functions • Modular expansion possible with up to
• PROFINET RT device according to
(redundancy, SNMP agent, port mirroring) 28 ports
conformance class B
• Extended temperature range of • Various IT management functions such as
• Optional MRP manager function
-40°C to +70°C redundancy, SNMP agent, port mirroring
• Various IT management functions
• Optional Layer 3 function
(redundancy, SNMP agent, port mirroring)
• Optional MRP manager function

Reliable control of large PROFINET networks


Task cells. In this way, any errors in the
In very large applications, such as in cell or in the network backbone
the automotive industry, a managed can be visualized. All data can also
infrastructure is the basis for high be transmitted to other network
availability. management tools via SNMP.
Implementation Summary
In PROFINET systems with lower- The managed switches form the high-
level cells, depending on the design, availability backbone for the individual
several hundred controllers work cells and the overall system. At the
with thousands of termination devices same time, they also act as the bridge
within one large network. head for the operator IT, up to Layer 3
functions. Reliable communication – between the
Technology
processing cells and the operator IT
Managed switches are used in the
individual cells. They are deeply
integrated into the control application
in PROFINET mode. The switches
ensure communication across the

PHOENIX CONTACT 41
Realtime switches

Thanks to their integrated ERTEC


technology, the realtime switches from
Phoenix Contact offer optimum properties
for PROFINET applications with increased Your advantages with realtime
switches
jitter and synchronization requirements. Optimum PROFINET integration –
thanks to hardware-based determination
They enable you to structure your networks of distances, fiber optic diagnostics,
flexibly, as they can be used directly in prioritized data exchange, and fixed
bandwidth reservation for PROFINET
the field or in small control boxes. These telegrams
switches integrate IT functions with hard Easy handling – error-free device
realtime requirements – with up to 1 μs replacement in the field possible, thanks
to local storage of all settings on a
accuracy. memory card
Maximum availability – robust metal
housing in IP20 or IP67, with redundant
power supply as an option

42 PHOENIX CONTACT
IRT switch IRT switch IRT switch, IP67

FL SWITCH IRT 4TX FL SWITCH IRT 2TX 2POF FL SWITCH IRT IP TX/3POF
FL SWITCH IRT TX 3POF
The PROFINET IRT switch range enables PROFINET IRT switch version with IP67
the creation of tree structures and rings in The IRT switch versions with 2 or 3 POF protection
PROFINET IRT networks interfaces support IRT structuring • With 1 copper port and 3 fiber optic ports
• 4 copper ports in RJ45 format • With 1 or 2 copper ports and 2 or 3 fiber • Hardware-supported PROFINET
• Hardware-supported PROFINET optic ports prioritization according to conformance
prioritization according to conformance • Integrated ERTEC technology and class C
class C hardware-supported PROFINET • Indication of the distance
• Indication of the distance prioritization
• Easy field installation, thanks to push-pull
• Diagnostics and indication of the distance connection technology (AIDA)
• POF ports for creating interference-free • POF ports for creating interference-free
fiber optic rings that can be diagnosed fiber optic paths that can be diagnosed

Prio. 6
Ethernet
I = xm I = xm I = xm

FO Ethernet
PROFINET PROFINET/Ethernet

Fiber optic budget Fiber optic budget


PN = Prio. 6 POF > xdB POF > xdB

Prioritized PROFINET data transmission Diagnostics for fiber optic paths


The realtime switches scan the header of incoming The FL SWITCH IRT devices can be diagnosed via
data packets for a PROFINET ID and always forward PROFINET fiber optic paths and the diagnostic data
PROFINET telegrams with the highest priority – and in made available to the controller.
the realtime data phase in the case of PROFINET IRT It is therefore possible to continuously monitor the
bandwidth reservation. quality of the fiber optic paths. For improved assessment
In this way, even Ethernet telegrams with the highest of the fiber optic path, FL IRT switches also make the
priority rating (priority 6), which video streams also use distances between two devices in the PROFINET device
for example, do not adversely affect PROFINET realtime available to the maintenance engineer.
communication.

PHOENIX CONTACT 43
Industrial Bluetooth

Bluetooth is the ideal solution for reliable


wireless communication with PROFINET –
even for safety applications.
Your advantages with Bluetooth
The FL BT EPA Bluetooth Ethernet modules
port adapter connects your PROFINET- • Extremely reliable wireless
transmission, thanks to redundant
compatible automation devices wirelessly transmission channels
to the network – quickly and easily. • Working range of up to 100 m in open
The EPA modules are optimized for industrial halls and up to 250 m
outdoors (depending on ambient
PROFINET and PROFIsafe. Typical features conditions)
of PROFINET such as IP address assignment • A secure wireless path can be
established quickly and easily by
via DCP (Discovery and Configuration pressing the Mode button
Protocol) and neighbor detection with
LLDP (Link Layer Discovery Protocol) are
therefore supported. PROFINET packets
are also prioritized based on the IP header
information and are transmitted over the
wireless path with priority.

44 PHOENIX CONTACT
Bluetooth Ethernet Bluetooth Ethernet Bluetooth access point
adapter adapter set

FL BT EPA FL BT EPA AIR SET FL BT EPA MP


The EPA “intelligent antenna” concept Complete set for the easy wireless The EPA MP (multipoint) enables the
combines a reliable wireless module with integration of a PROFINET or PROFIsafe creation of a Bluetooth network with up to
an integrated special antenna in compact device in a PROFINET network – seven connections. Thanks to the external
and robust IP65 industrial housing – easy setup using the Mode button. antenna connection, various different
for extremely easy integration in your antennas can be used which suit the specific
application. application.

Fast movement of goods with PROFINET


Task Bluetooth paths can be optimally
In container ports or distribution integrated in PROFINET networks.
centers, there are typically large The PROFINET-optimized
numbers of autonomous, moving configuration, including prioritization
system parts. In practice, most of these and LLDP support, can be easily
areas are equipped with numerous selected via the Mode button and the
WLAN access points. connected termination devices are
optimally integrated into the network.
Implementation
Regardless of whether the PROFINET Summary
devices are operating as devices in the Particularly in applications that already
network or whether a controller acting involve high-density wireless data
as the PROFINET master distributes traffic, PROFINET does not just permit Integration, startup, and diagnostics of
the data to the I/O modules via the use of Bluetooth but actually autonomous system parts via PROFINET
Bluetooth, practically any number of allows the sections to be integrated
systems can be operated in parallel seamlessly into the overall PROFINET
in the overall system through the use network.
of the enhanced frequency hopping
method.
Technology
Whether to provide redundancy or
as the only way to transmit data, the

PHOENIX CONTACT 45
Industrial WLAN

Wireless LAN – unrivaled flexibility


combined with low maintenance and
installation costs.
Your advantages with the
The latest generation of our WLAN WLAN 5100 access point
modules supports IEEE 802.11n with Faster – the new high-speed
WLAN 5100 brings WLAN 802.11n to
MiMo (multiple input multiple output) industrial applications and with it a data
technology for maximum reliability, data rate of up to 300 Mbps
throughput, and range. In combination with Further – thanks to its excellent
receiver technology and higher
the integrated QoS (Quality of Service) transmission power, the range of the
prioritization, time-critical PROFINET or new WLAN 5100 is up to four times
greater*
safety applications can be implemented More reliable – MiMo technology with
with low latency. three antennas significantly increases the
robustness, speed, and range of wireless
communication

* Compared to current 802.11b/g


WLAN devices. The range depends
on the antennas used and the ambient
conditions. The actual performance can
vary according to range, connection
speed, ambient conditions, size of the
network, and other factors.

46 PHOENIX CONTACT
WLAN 5100 WLAN
access point Ethernet adapter

FL WLAN 5100 FL WLAN EPA


FL WLAN 5101 FL WLAN EPA 5N
FL WLAN EPA RSMA
• Supports the 2.4 GHz and 5 GHz band
• PROFINET prioritization based on the • Modules for the 2.4 GHz and 5 GHz band
Ethernet header information • PROFINET prioritization based on the
Ethernet header information

Improved warehousing with PROFINET


Task Summary
Today, shuttles that store and retrieve Thanks to the compact design of
goods replace more and more the Ethernet adapters, PROFINET
conventional storage and retrieval communication can be transmitted to
equipment in high rack systems. the shuttles without any problems.
Roaming is also supported where
Implementation
multiple access points are used.
Shuttles represent an efficient
solution as many vehicles can operate
in the racks in parallel. The energy
consumption of shuttles is low and
when parked the batteries of these
autonomous transport devices are Convenient wireless connection of high rack
charged. shuttles and storage systems with PROFINET

Technology
A central PROFINET controller is used
in the storage system which transmits
commands to the shuttles wirelessly,
wherever they are in the system.

PHOENIX CONTACT 47
Security routers and firewalls

Failures, sabotage or data loss can result


in significant financial losses. With mGuard
technology, Phoenix Contact offers an
industrial firewall/router solution for the Your advantages with
mGuard security routers
DIN rail. Thanks to IPsec encryption, the Easy – the mGuard components
VPN versions can also be optimally used in are integrated into the network as
autonomous systems
remote maintenance.
Flexible – the firewall can protect
Another advantage of the mGuard range entire PROFINET production cells or
termination devices such as visualization
is the 1:1 NAT function which means that PCs or servers
there is no need to readdress a machine or Secure – incoming and outgoing data
packets are protected with predefined
system, e.g., for PROFINET-controlled wind firewall rules with no adverse affect on
power plants that are identically networked the protected systems
in a wind park.

48 PHOENIX CONTACT
Firewall/router PCI firewall/router Gigabit firewall/router

FL MGUARD RS2000 TX/TX VPN FL MGUARD PCI4000 FL MGUARD GT/GT


FL MGUARD RS4000 TX/TX FL MGUARD PCI4000 VPN FL MGUARD GT/GT VPN
FL MGUARD RS4000 TX/TX VPN
Stateful inspection firewall that can be Gigabit-capable firewall/router for maximum
DIN rail-mountable stateful inspection integrated in PCI format for every PC data throughput on the DIN rail
firewall/router • Reduced engineering effort and IP • 2 SFP ports
• Reduced engineering effort and IP addresses saved, thanks to 1:1 NAT • Reduced engineering effort and IP
addresses saved, thanks to 1:1 NAT • External storage medium for the addresses saved, thanks to 1:1 NAT
• External storage medium for the configuration • External storage medium for the
configuration • Maximum level of security with encrypted configuration
• Maximum level of security with encrypted VPN connection and IPsec protocol • Maximum level of security with encrypted
VPN connection and IPsec protocol (VPN versions) VPN connection and IPsec protocol
(VPN versions) (VPN versions)

Comfortable boarding with PROFINET


Task and position. However, each boarding
Passenger boarding bridges are installed bridge is also integrated into the
at international airports which are airport network.
directly integrated into the operator's Summary
network. These bridges are fully
Thanks to the use of the mGuard
automated and offer maximum comfort
router with its stateful inspection
for boarding practically any type of plane.
firewall, it is possible to effectively
Implementation separate the bridges from and to the
The boarding bridges are part of a airport network. The required TCP
complex system based on a database, ports are explicitly enabled during
which also provides apron information startup.
for pilots. Laser information provides Integration and efficient control of
optimum support for pilots when boarding bridges in the network
taxiing.
Technology
Each passenger boarding bridge has
its own PROFINET controller which
controls the devices in the bridge
and continuously readjusts the height

PHOENIX CONTACT 49
Media converters

For maximum immunity to interference and


transmission ranges in industrial Ethernet
applications, media converters transparently
FO converter
convert Ethernet data to fiber optics.
Rugged
We offer the right technology for every
FL MC 2000E LC
application: media converters with 1300 nm FL MC 2000E SM40 LC
wavelength for particularly large distances, • Suitable for applications in energy
technology according to IEC 61850
devices with 660 nm for easy-to-use
• Robust design for high EMC requirements
POF/HCS technology or media converters • Devices for multi-mode and single-mode
with WDM technology for single-fiber fibers, up to 40 km with LC duplex
connection
transmission, e.g., in rotating applications. • Pass through mode with short latency for
time-critical applications such as
Media converters with short latency PROFINET RT
are particularly suitable for time-critical
applications such as PROFINET RT.

50 PHOENIX CONTACT
FO converter FO converter FO converter
Standard Single fiber Optical diagnostics

FL MC EF 1300 MM SC FL MC EF WDM-SET FL MC 10/100BASE-T/FO 660


FL MC EF 1300 MM ST
• Full duplex communication using a single • For distances up to 300 m with easy-to-use
FL MC EF 1300 SM SC
glass fiber POF/HCS technology
• Devices for multi-mode or single-mode • Single-fiber transmission of optical signals in • Integrated optical diagnostics of the fiber
fibers and various connection technologies rotating applications with optical slip rings optic connection for high availability
• Diagnostic functions for continuous link • Save on cable fibers and plugs and also • Pass through mode with short latency for
monitoring for optimum availability double the bandwidth of existing cable time-critical applications such as
• Auto negotiation for easy startup connections PROFINET RT

PROFINET in the blades of wind power plants


Task wavelengths (1310 and 1550 nm) for
To achieve consistent PROFINET the input and output data. This makes
communication in wind power plants, it possible to communicate with the
fiber optic technology is also required rotor hub via a single fiber.
in the rotating parts of the plant. In Summary
addition to the physical limits of copper
The significant price difference between
cables with regard to distance, the key
single and two-channel optical rotary
factor is resistance to EMC.
joints makes the use of this media
Implementation converter an attractive solution. It
In wind power plants, information such allows full duplex operation combined
as pitch control is transmitted to the with absolute EMC robustness and an
rotating part. This must work reliably extended temperature range. Reliable data transmission for all aspects of
in order to ensure the availability of the slip ring communication in wind power plants
plant. In addition, practical diagnostics
must be possible for all devices.
Technology
A pair of media converters convert the
PROFINET signals at both ends using a
multiplex method, which uses different

PHOENIX CONTACT 51
Network isolators and
RJ45 patch panels

The FL ISOLATOR electrically isolates


copper-based Ethernet devices with
transmission speeds of up to 1 Gbps. With
high-quality electrical isolation up to 4 kV, Your advantages with the
FL ISOLATOR
immunity to interference is increased • Electrical isolation of data cables and
significantly in industrial applications. cable shielding
Transparent data transmission enables use • Electric strength of up to 4 kV
• Transmission speed of up to 1 Gbps
in all PROFINET applications.
• No power supply required
The mini patch panels provide a convenient • Easy installation upstream of the
alternative to on-site assembly of RJ45 network device to be protected
plugs. The cross-control-cabinet field • Approval for EN 50121 (track) and
EN 50155 (rolling stock)
cabling is simply connected to screw, • Different versions for different
spring-cage or IDC connection terminal installation requirements
• Protocol-transparent and immediate
blocks, depending on the version selected.
data transmission
RJ45 patch cables are then used for
connection to the termination devices.

52 PHOENIX CONTACT
Network isolator Network isolator Ethernet patch panel
with RJ45 connection up to 100 Mbps with with various connections
M12 connection

FL ISOLATOR 1000-RJ/RJ FL ISOLATOR 100-M12 FL-PP-RJ45-SC, 8-pos.


FL ISOLATOR 100-RJ/SC FL ISOLATOR 100-M12 RMS FL CAT5 TERMINAL BOX, 4-pos.
FL ISOLATOR 100-RJ/RJ FL-PP-RJ45-SCC, 8-pos.
• Network isolator for electrical
FL-PP-RJ45-LSA, 8-pos.
• Network isolator for electrical isolation up to 4 kV
FL-PP-RJ45/RJ45, 8-pos.
isolation up to 4 kV • Transmission speeds of up to 100 Mbps FL-PP-RJ45/RJ45-B, 8-pos.
• Transmission speeds of up to 1 Gbps • Vibration-proof M12 connection
• DIN rail mounting
• Plug-in screw terminal block for convenient technology with SPEEDCON rapid
connection of field cables, marked with interlock system • CAT5e
PROFINET cable colors • Flexible installation options, thanks to • Shielding either directly on DIN rail or via
wall and DIN rail mounting RC combination
• Ideal for railway applications

Comfortable rail travel with PROFINET


Task temperature range of -40°C to +70°C
Especially in rail vehicles, large potential and meets all the requirements of
differences can occur between the European railway standards. The
individual train segments. In addition, device can also be mounted outside
very high demands are placed on the of the control cabinet and does not
mechanical stability of the products generate any additional latency in
and compliance with the corresponding communication.
standards is therefore essential. Summary
Implementation Immediate data communication with
The train segments are electrically increased safety enables undisturbed
isolated from one another using communication and enhances passenger
isolators. The devices do not require comfort. Immediate data communication across all
an additional power supply and are train segments
protocol transparent, so can also be
used in PROFINET networks without
any problems.
Technology
Electrical isolation via the M12
connections of up to 4 kV enables a

PHOENIX CONTACT 53
Surge protection

Phoenix Contact has developed special


surge arresters to protect the sensitive
interfaces of automation devices in
PROFINET networks. For example, a new DATATRAB – the all-round solution
for protecting data interfaces
surge protection device for high-speed data In addition to the DT-LAN-CAT.6+,
networks is available in the form of the which combines various data protocols
in a single device, the DATATRAB
new DATATRAB DT-LAN-CAT.6+, which range offers further versions for serial
meets performance requirements in terms bus interfaces. The different versions
conform to the respective system and
of transmission quality according to Class EA are equipped with the appropriate
(CAT6+). This means that even data rates connection technology.
of up to 10 Gbps can be reliably transmitted 19" rack
according to the latest standard. • Very compact
• Protects up to 24 RJ45 ports
In addition to protecting data, the protection
• Top connections for communication
of the power supply must also be considered. with hubs and switches
• Bottom connections for building cabling
• Protects all 8 wires of the data cable
• Direct grounding via housing connection
• Indirect grounding via gas-filled surge
arrester in the housing

54 PHOENIX CONTACT
DATATRAB adapter / DATATRAB
DIN rail module 19" versions

DT-LAN-CAT.6+ DT-LAN-19"-24
DT-LAN-19"-20
• Protective adapter for insertion in the
DT-LAN-19"-16
data cable to protect LAN interfaces
DT-LAN-19"-12
according to Class EA/CAT6 (10GBaseT)
DT-LAN-19"-8
• IEC category: C1, C2, C3, D1 DT-LAN-19"-4
• Maximum continuous voltage Uc: 3.3 V
• With surge-protected ports
• Nominal discharge current: 2 kA (8/20)
• For use in Ethernet/PROFINET, token ring,
• Cut-off frequency fg: > 500 MHz FDDI/CDDI, according to Class D/CAT5e
of EN 50173 (1GBaseT)
• IEC category: C1, C2, C3
• Maximum continuous voltage Uc: 6 V
• Nominal discharge current: 10 kA (8/20)

LNK MODE LNK MODE LNK MODE LNK MODE LNK MODE LNK MODE LNK MODE LNK MODE
X 13 X 15 X 17 X 19 X 13 X 15 X 17 X 19

X 14 X 16 X 18 X 20 X 14 X 16 X 18 X 20
FL SWITCH GHS 8GT/8 FL SWITCH GHS 8GT/8
Ord. No. 29 83 200 Ord. No. 29 83 200
X 29
X29 X 29
X29
MEM MEM
MAC MAC
Address Address

X1 X7 US1 X1 X7 US1
US2 US2
X2 X8 FAIL X2 X8 FAIL
X3 X9 X3 X9

X4 X10
10 X4 10
X10

X5 X11
X11 X5 X11
X11

X6 X12 X6 X12

LNK LNK
X1 X3 X5 X7 X9 X1
X11 X1 X3 X5 X7 X9 X1
X11
X 1 2 3 4 5 6 7 8 9 10 11 12 X 1 2 3 4 5 6 7 8 9 10 11 12
X2 X4 X6 X8
X30 X100 X12
X30
US1 GND US1
US2 D11D12 U I X2 X4 X6 X8
X30 X100 X12
X30
US1 GND US1
US2 D11D12 U
UII
MODE MODE
(X1 or X5
5 _ X 4or X8) (X1 or X5
5 _ X 4or X8)
S1 GND US2 GND|UI GNDI
X30 US1 X31 UI GNDI|DI1 DI2 R1 R2 R3 R4 V.32 V.24 S1 GND US2 GND|UI GNDI
X30 US1 X31 UI GNDI|DI1 DI2 R1 R2 R3 R4 V.32 V.24

MODE MODE

FL SWITCH SMSC 8GT FL SWITCH SMSC 8GT


Ord. No. 2891123 Ord. No. 2891123

1 3 5 7 1 3 5 7

ACT SPD FD 2 4 6 8 ACT SPD FD 2 4 6 8

LINK
LINK LINK
MAC US1 US2 FAIL MAC US1 US2 FAIL
Address 1 2 3 4 5 6 7 8 Address 1 2 3 4 5 6 7 8
00.A0.45.08.04.02 00.A0.45.08.04.02
Mode Mode

aggregation
X9 X10 X11 X12 X9 X10 X11 X12
US1 GND US2 GND R1 R2 MEM V24 US1 GND US2 GND R1 R2 MEM V24
Ethernet

FO
Gig abit

OUT
PoE OUT
DATATRAB 2881007

DATATRAB 2881007
DT-LAN-CAT.6+ U c: 7 V DC

DT-LAN-CAT.6+ U c: 7 V DC

OUT
DATATRAB 2881007
I n:
I max : 1,5 A

I n:
I max : 1,5 A
2,5 kA asym.

2,5 kA asym.
DT-LAN-CAT.6+ U c: 7 V DC
I n:
I max : 1,5 A
2,5 kA asym.

PLC
MRESET RUN
STP FAIL E
11 15 19 Q1 US
RUN/PROG 12 16 I10 Q2 UM
13 17 I11 Q3 UL
14 18 I12 Q4
ETH
10/100 BASE-T

LNK INLINE CONTROL


ACT ILC 350 ETH
100 Ord.No.: 2737203

RESET

IL
PRG
RDY/RUN
BSA
FAIL
PF

DATATRAB: high-speed surge protection for unrivaled Gigabit performance

PHOENIX CONTACT 55
Copper cabling:
assembled cables

In PROFINET, copper-based data


transmission is designed such that a
channel length of 100 m can always be
implemented with a uniform cable type, Your advantages with PROFINET
cables
whereby a maximum of four connectors All assembled PVC (type A/B) and PUR
are permitted. Any combination of solid (type C) cables are 100 % electrically
tested. They are flame-retardant and
(type A), stranded (type B), and special their transmission properties meet
cables (type C) is possible. CAT5e.
In order to satisfy requirements in the
We offer the right cabling solution for your field of automation, the cables have a
application. SPEEDCON rapid interlock higher degree of protection. All cables
and lines comply with PROFINET
technology cuts connection time by 90%. guidelines.

56 PHOENIX CONTACT
Data, M12, D-coded, and Power, M12, T-coded Power supply, M12,
RJ45 A-coded

Straight M12 pin to free cable end Straight pin to free cable end Straight pin to free cable end
NBC-MSD SCO-PN/.../... SAC-4P-MST/ ...-PUR SCO SAC-5P-MS/ ...-186 SCO
Straight M12 pin to straight RJ45 Straight socket to free cable end Straight socket to free cable end
NBC-MSD-R4AC SCO-PN/.../... SAC-4P- ...-PUR/FST SCO SAC-5P- ...-186/FS SCO
Straight M12 pin to angled RJ45 Straight pin to straight socket Straight pin to straight socket
NBC-MSD-R4ACR SCO-PN/.../… SAC-4P-MST/ ...-PUR/FST SCO SAC-5P-MS/ ...-186/FS SCO
Straight M12 pin to version 14 metal Angled pin to free cable end • Other cable assemblies available on request
NBC-MSD-R4RC SCO-PN/.../… SAC-4P-MRT/ ...-PUR SCO
• 5-pos. cable
Straight M12 pin to straight M12 pin Angled socket to free cable end
NBC-MSD-MSD SCO-PN/.../... SAC-4P- ...-PUR/FRT SCO • (...) denotes cable length in meters that
can be selected
Straight M12 pin to angled M12 socket • Other cable assemblies available on request
NBC-MSD-FRD SCO-PN/.../…
• 4-pos. cable
Straight M12 pin to straight M12 socket
NBC-MSD-FSD SCO-PN/.../… • (...) denotes cable length in meters that
can be selected
• Other cable assemblies available on request
• 4-pos. cable
• First instance of (...) denotes cable type
(e.g. , “93C”), second instance of (...)
denotes cable length in meters that can be
selected

Main parameters of symmetrical PROFINET cables

PROFINET type A PROFINET type B PROFINET type C


Cable type
Designation: 93A Designation: 93B / 93M / 937 Designation: 93C / 93R

Installation type Stationary, Moveable, Special applications


no movement after occasional movement (e.g., highly flexible, continuous
installation or vibration movement or torsion)

Conductor cross section AWG 22/1 AWG 22/7 AWG 22/..

Cable diameter 5.5 - 8.0 mm Application-specific

Conductor diameter 1.5 ±0.1 mm Application-specific

Sheath color Green, RAL 6018 Application-specific

Shielding Aluminum foil and braided shield Application-specific

Number of conductors 4

Relevant standards IEC 61784-5-3 / IEC 61918_ed. 2.0

Environmental class Outside enclosure

Note: other cable types available on request

PHOENIX CONTACT 57
Copper cabling:
connectors for assembly

The connectors for assembly for symmetrical


cabling with copper cables are optimally
tailored to the requirements of PROFINET
and its cables. IDC and spring-cage connection
RJ45 and M12 connectors with our
Fast connection technology simplifies work QUICKON fast connection technology
on site. are available for fast local assembly of
patch cables.
No special tools are required to
assemble the connectors. The wires
are simply connected in the connector
without stripping. In addition,
conventional spring-cage connection
technology is available in the M12
connector.

58 PHOENIX CONTACT
PROFINET connectors for copper conductors

Connectors for data transmission Connectors for power supply

Copper Class 2 Class 1

RJ45 RJ45 M12 D-coded M12 X-coded Push-pull M12 power M12
2-pair 4-pair 2-pair 4-pair power T-coded A-coded
IP20 protection

– – – – –

RJ45 RJ45
INDUSTRIAL INDUSTRIAL
IP65/IP67 protection

Push-pull ADVANCE Push-pull ADVANCE Push-pull


version 14 version 14 M12 plug connector M12 socket M12 socket
device connection
Modular

Push-pull Push-pull Push-pull


panel mounting panel mounting M12 flush-type M12 flush-type panel mounting M12 flush-type M12 flush-type
frame frame connector, socket connector, socket frame connector connector

Modern automation processes and PROFINET


Adapters and accessories devices require a durable and reliable
connection for data and power transmission.
M12 to RJ45 M12 to RJ45 Robot RJ45 Our connectors and adapters with IP20
4-pair 4-pair multi-port patch panel and IP65/IP67 protection for cabling with
copper cables have been developed and are
designed for the permanent operation of your
applications:
• High vibration resistance
IP20


• High transmission reliability
• High resistance to EMC/ESD
Bulkhead Bulkhead
D-coded X-coded Patch panel • Protection against inadvertent removal
IP65/IP67

– –

Multi-port Terminal
distributor outlet

PHOENIX CONTACT 59
Fiber optic-based data cabling

High transmission speed, low attenuation,


and no electromagnetic interference.
Networking with fiber optics is particularly
suitable for fast, safe, and modern data The right fiber type for your
application
communication in PROFINET applications • POF (polymer optical fiber) for short
and the infrastructure of industrial systems. transmission paths up to 100 m and a
maximum data rate of up to 100 Mbps
You can rely on Phoenix Contact's many
• PCF (polymer-clad fiber) for medium-
years of experience. length transmission paths up to 500 m
and a maximum data rate of up to
1 Gbps
• GOF (glass optical fiber) multi mode for
long transmission paths up to 4.5 km
and a data rate of up to 10 Gbps
• GOF single mode up to 50 km and a
data rate of up to 40 Gbps

60 PHOENIX CONTACT
PROFINET connectors for fiber optics

Fiber optic connectors

SC-RJ POF SC-RJ POF SC-RJ HCS SC-RJ HCS


IP20 protection

– –

SC-RJ SC-RJ
IP65/IP67 protection

Push-pull ADVANCE Push-pull Push-pull ADVANCE Push-pull


device connection
Modular

Push-pull panel mounting frame, Push-pull panel mounting frame, Push-pull panel mounting frame, Push-pull panel mounting frame,
metal plastic metal plastic

Number of additional Maximum channel lengths


Optical channels
plug-in connections POF PCF GOF-MM GOF-SM

EQP TE 0 50 m 100 m 2000 m 14,000 m

EQP TE 1 43.5 m 100 m 2000 m 14,000 m

EQP TE 2 37 m 100 m 2000 m 14,000 m

Steckverbinder Extract from the PROFINET installation guidelines


EQP: Equipment TE: Terminal equipment Connector
Steckverbinder Plug-in connection
Steckverbindung

Steckverbinder
Steckverbindung
Steckverbinder
Steckverbindung
Unlike generic cabling, PROFINET makes it possible to
Steckverbinder The definition of the channel eliminates the need for plug-in
Steckverbindung
generate the channel for various industrial situations without connections on the active devices. This must be taken into
Steckverbindung
significant planning effort. consideration when determining the plug-in connections in the
channel.

PHOENIX CONTACT 61
PROFINET expertise:
implementation

Do you want to integrate PROFINET in


your automation devices and solutions?
KW-Software supports you with all aspects
of this leading automation technology. Quick and easy
PROFINET integration
KW-Software provides technology • The technology components have
been developed and are available for
components for integrating PROFINET different CPU types and operating
controller and device interfaces, as well as systems.
for safe communication with PROFIsafe V2. • They can be quickly adapted to your
individual device platform, if required.
You can therefore quickly implement
and certify your PROFINET interface.

62 PHOENIX CONTACT
PROFINET PROFINET network Safe communication
communication stacks configuration via PROFINET

PROFINET controller/device PROFINET configurator PROFIsafe V2


The PROFINET stacks can be used The PROFINET configurator provides basic Automation devices with safety functions
on platforms with standard Ethernet and convenient functions for configuring require special communication profiles for
interfaces – from a DIN rail PC to a and parameterizing PROFINET networks. safe data exchange in the network. PROFIsafe
complex robot controller. Isochronous These include scanning and diagnosing the V2 is the communication profile for safety
realtime communication (PROFINET IRT) connected devices. technology with PROFINET.
is also possible with the I210 Intel Ethernet A special network display shows the topology KW-Software supports you during the
controller. of your PROFINET network. The PROFINET development of your safe automation device
A highly integrated communication solution configurator can be used on its own or with certified software components and an
specifically for compact I/O devices and integrated in a programming system. open technology platform.
drives is available in the form of the TPS-1
single chip device interface.

KW-Software –
technology for automation leaders
As a leading supplier, KW-Software has been developing
software for the global players in automation for more than
30 years. Our core technologies of IEC 61131 CONTROL,
IEC 61508 SAFETY, and PROFINET are used successfully
worldwide.
Technology from KW-Software provides the proven and
future-oriented foundation for hundreds of thousands of
automation devices and systems. Our products demonstrate
their quality and reliability in state-of-the-art machines and
systems on a daily basis. The range of applications spans
almost all branches of industry. KW-Software is based in the CENTRUM INDUSTRIAL IT (CIIT ) on the
campus of the Ostwestfalen-Lippe University of Applied Sciences in
Find out more: kw-software.com Lemgo, Germany. The CIIT is the Science to Business Center for
automation. Here we work in close cooperation with renowned research
institutions.

PHOENIX CONTACT 63
PROFINET expertise:
testing

Phoenix Testlab is an accredited PROFIBUS


and PROFINET International (PI) test
laboratory and has been performing
certification tests for PROFINET IO devices Your advantages with
Phoenix Testlab
for several years. • High quality of testing by specialized test
engineers
The 140 employees of the independent
• Flexible processing of all orders in a
test laboratory and certification institute timely manner
provide advice on and also test and certify • Comprehensive full service for your
device
various specific areas of technical products.
• Many years of experience in all areas of
This also includes protocol tests for fieldbus testing
systems. • Supplementary testing such as
PROFIenergy profile test, network
load test, PROFIsafe profile test
(external) or pretesting during
development

64 PHOENIX CONTACT
State machine test GSD file test Interoperability test

Semi-automated testing of standardized The device description file is the basis for A key requirement of end users is that
state machines using special test software. error-free configuration using configuration I/O devices and I/O controllers from
This guarantees reproducible testing with an software. different manufacturers work together
extendable number of test scenarios. Automatic test software is used to test all in an automation system without any
Compliance with IEC 61158-5-10, entries offline. problems. Phoenix Testlab uses various
IEC 61158-6-10, and IEC 61784. Conformity with current requirements is PROFINET IO devices and controllers to test
checked. interoperability. The test setup is constantly
being extended to incorporate a wider
variety of devices.

Full service from a single source


Consultation and test planning:
PROFINET conformance testing as a recognized PI test
laboratory:
• State machine test
• Hardware test
• Interoperability test
• GSD file test
• EMC test
Phoenix Testlab in Blomberg, Germany, www.phoenix-testlab.de
Additional/supplementary tests:
• Recognized by the Federal Maritime and Hydrographic Combining consultation, complete testing, certification,
Agency of Germany for testing in accordance with and training lays the best foundations for seamlessly
maritime classification standards and inexpensively integrating Phoenix Testlab into your
• Environmental simulation tests (climate, vibration, development, production, and quality management.
corrosion, IP protection tests, etc.) The service offered not only includes technical testing of
• Testing in accordance with established standards of products, but also international management of approvals
automobile manufacturers for your devices.
• Radio tests
• EMC tests
Worldwide certification management for your
products:
• Notified body according to R&TTE Directive 99/5/EC;
Telecommunication Certification Body (TCB) according to
FCC, USA
• Competent body according to EMC Directive 89/336/EEC

PHOENIX CONTACT 65
PROFINET expertise:
service and support

Whatever the task at hand, the PROFINET


solution you are looking for to meet your
objective or the products you would like to
use: our specialists are always on hand no Professional service
We provide comprehensive support
matter where you are. throughout the implementation of your
PROFINET application. Benefit from our
Our flexible service concept enables an expertise in the following areas:
approach on every imaginable level, thanks • PROFINET
to the extensive technological expertise • Industrial Ethernet
of our specialists. At the same time, the • Ethernet security
• Wireless LAN
specific requirements of all industries are
• Bluetooth
taken into consideration. We always have • PC WORX
the right solution for you.

Your personal contact person will provide


telephone support and, in the event of a
fault, will organize immediate delivery of
replacement parts or on-site service.

66 PHOENIX CONTACT
Training Service Engineering

Discover the added value our individual You can rely on our support for the smooth Whatever your automation task: our
training concepts and training services offer. operation of your application. Our experts engineering specialists are available to answer
With our tailor-made concepts, we help you deal with queries encountered in practical any questions you may have. Based on the
and your employees to make optimum use applications every day. They draw on their typical phases of a project, we work with you
of the control and I/O systems from Phoenix experience of all sectors and knowledge of at each stage.
Contact. the components and technologies used. With our expertise and years of experience
With our free consultation service, you Our service specialists will be happy to we provide support that is tailored to your
can arrange with us the contents, duration, support you with the following services: industry and the specific phase of your
location, and date of your individual training • Hotline project.
session. • On-site service Simply give us an outline of the applications
Should you have any queries regarding our you would like to implement and we will
• Startup support
training services and qualification concepts, provide you with a technical concept that
• Professional workshops includes suitable hardware and software.
please contact your local contact person or
contact our Back Office Training team directly If queries arise during startup and operation, • Configuration
(+ 49 5281 9 -4 62161 or e-mail us on in addition to your local specialists you can
• Programming
automation-training@phoenixcontact.com). also contact our free 24-hour hotline at any
time (+ 49 5281 9-462888) or e-mail us on • Visualization
We will happily advise you on the
automation-service@phoenixcontact.com. • Coaching
implementation of your qualification
requirements and work with you to create If this is not sufficient, our startup support If queries arise in the run-up to or during a
your own individual training program. team and on-site service will be there to project, in addition to your local specialists
provide assistance. you can also contact us at any time on
+ 49 5 281 9 -462166 or e-mail us on
projectconsulting@phoenixcontact.com.

Certified PROFINET Installer Certified PROFINET Engineer


Professional network installation The training covers the particular
is crucial when it comes to the requirements that must be observed
availability and quality of PROFINET during planning, programming, and
communication. startup for a PROFINET system.
Once they pass the final examination,
Once they pass the final examination,
participants receive the certificate of
participants receive the certificate of
“Certified PROFINET Engineer” which
“Certified PROFINET Installer” which
is recognized by the PNO.
is recognized by the PNO.

PHOENIX CONTACT 67
Always up-to-date, always available to you. Here
you'll find everything on our products, solutions
and service:

phoenixcontact.net

Product range
• Cables and connectors • I/O systems • Plug-in connectors
• Controllers and PLCs • Industrial communication technology • Protective devices
• DIN rail power supplies and UPS • Industrial lighting • Relays
• Electronic reversing contactors and • Installation and mounting material • Sensor cables and connectors
motor control • Marking and labeling • Software
• Electronics housing • Measurement and control technology • Surge protection devices
• Ethernet networks • Modular terminal blocks • System cabling for DCS and PLC
• Fieldbus components and systems • Monitoring and signaling • Tools
• Functional safety • PCB terminal blocks and • Wireless data communication
• HMIs and industrial PCs PCB connectors

© PHOENIX CONTACT 2013


Printed in Germany
52005040/2013-09-16/01
MNR 52004384/2013-09-16/01