You are on page 1of 5

Electronic Service Tool 2015A v1.

0
Product Status Report

6/22/2019 11:47 AM

Product Status Report


Parameter Value
Engine Serial Number JGBF5119U22626U
Equipment ID ALLAM MARINE LTD
Comments

2806-E18 (JGBF5119U22626U)
Parameter Value
Equipment ID ALLAM MARINE LTD
Engine Serial Number JGBF5119U22626U
ECM Serial Number 27106233JL
Software Group Part Number 3049466-00
Software Group Release Date APR08
Software Group Description 2806 50/60Hz BSFC

Critical Events - 2806-E18 (JGBF5119U22626U)


Description Start Time Elapsed Extreme Average
No Critical Events.

Logged Diagnostic Codes [ECM Diagnostic Clock = 24855.6393 hours] - 2806-E18


(JGBF5119U22626U)
Code Description Occ. First Last
No Logged
Diagnostic
Codes

Logged Event Codes [ECM Diagnostic Clock = 24855.6393 hours] - 2806-E18


(JGBF5119U22626U)
Code Description Occ. First Last
No Logged
Events

Active Diagnostic Codes - 2806-E18 (JGBF5119U22626U)


Code Description
261-13 Engine Timing Calibration : Out of Calibration

Active Event Codes - 2806-E18 (JGBF5119U22626U)


Code Description
No Active
Events
Current Totals - 2806-E18 (JGBF5119U22626U)
Description Value Unit
Total Engine Operating Hours 24856 hours

Configuration - 2806-E18 (JGBF5119U22626U)


Description Value Unit
Equipment ID ALLAM MARINE LTD
Engine Serial Number JGBF5119U22626U
ECM Serial Number 27106233JL
Software Group Part Number 3049466-00
Software Group Release Date APR08
Software Group Description 2806 50/60Hz BSFC
Rating Number 2
Rated Frequency 50 Hz
Rated Genset Speed 1500 rpm
Rated Real Genset Power Unavailable Parameter
Rated Apparent Genset Power 650 kVA
Engine Rating Application Type Prime
External Speed Selection Switch Installed Enabled
Engine Acceleration Rate 500 rpm/s
Droop/Isochronous Switch Installed Enabled
Droop/Isochronous Selection Isochronous
Engine Speed Droop 4.0 %
Digital Speed Control Installed Not Installed
Speed Control Minimum Speed 125 rpm
Speed Control Maximum Speed 125 rpm
Digital Speed Control Ramp Rate Unavailable rpm/s
Crank Terminate RPM 400 rpm
Desired Speed Input Arrangement 0-5 VDC Input
Fuel Enable Input Configuration Switch to Battery +
Critical Override Switch Installed Not Installed
Emergency Shutdown Override Input Switch to Ground
Configuration
Governor Gain Factor #1 15729
Governor Minimum Stability Factor #1 1049
Governor Maximum Stability Factor #1 2097
Full Load Setting (FLS) -2
Full Torque Setting (FTS) 17
Customer Password 1 ********
Customer Password 2 ********
Total Tattletales 3

Lifetime: Time vs Engine Coolant Temperature - 2806-E18 (JGBF5119U22626U)


Engine Coolant Temperature( hours %
Deg F )
<122 22.45 0.09
122-130 10.45 0.04
131-139 25.25 0.10
140-148 190.05 0.76
149-157 1036.45 4.17
158-166 2414.75 9.72
167-175 3532.10 14.21
176-184 9115.70 36.68
185-193 8326.05 33.50
194-202 170.05 0.68
203-211 11.15 0.04
212-220 0.20 0.00
221-229 0.00 0.00
230-238 0.00 0.00
239-247 0.00 0.00
>248 0.00 0.00

Lifetime: Time vs Intake Manifold Air Temperature - 2806-E18 (JGBF5119U22626U)


Intake Manifold Air hours %
Temperature( Deg F )
<104 0.00 0.00
104-112 0.00 0.00
113-121 0.00 0.00
122-130 0.05 100.00
131-139 0.00 0.00
140-148 0.00 0.00
149-157 0.00 0.00
158-166 0.00 0.00
167-175 0.00 0.00
176-184 0.00 0.00
185-193 0.00 0.00
194-202 0.00 0.00
203-211 0.00 0.00
>212 0.00 0.00

Lifetime: Time vs Intake Manifold Pressure (Gauge) - 2806-E18 (JGBF5119U22626U)


Intake Manifold Pressure hours %
(Gauge)( psi )
<12 0.00 0.00
12-12 0.00 0.00
13-14 0.00 0.00
15-15 0.00 0.00
16-16 0.00 0.00
17-18 0.00 0.00
19-19 0.00 0.00
20-21 0.00 0.00
22-22 0.00 0.00
23-24 0.00 0.00
25-25 0.00 0.00
26-27 0.00 0.00
28-28 0.00 0.00
>29 0.05 100.00

Lifetime: Time vs Actual Engine Speed And Engine Load Factor - 2806-E18 (JGBF5119U22626U)
rpm <1100 1100- 1300- 1500- 1700- 1900- 2100- >2300 Total
1299 1499 1699 1899 2099 2299
%
<50 1.35 0.25 13688.5 6797.00 0.00 0.00 0.00 0.00 20487.1
5 5
50-60 0.00 0.00 234.80 282.70 0.00 0.00 0.00 0.00 517.50
60-70 0.00 0.00 71.45 72.70 0.00 0.00 0.00 0.00 144.15
70-80 0.00 0.00 4.85 2.95 0.00 0.00 0.00 0.00 7.80
80-90 0.00 0.00 0.20 0.10 0.00 0.00 0.00 0.00 0.30
>90 0.05 0.00 0.05 0.00 0.00 0.00 0.00 0.00 0.10
Total 1.40 0.25 13999.9 7155.45 0.00 0.00 0.00 0.00 21157.0
0 0

Lifetime: Total Occurrences vs Actual Engine Speed - 2806-E18 (JGBF5119U22626U)


Actual Engine Speed( rpm ) %
<2500 0.00 0.00
2500-2599 0.00 0.00
2600-2699 0.00 0.00
2700-2799 0.00 0.00
2800-2899 0.00 0.00
2900-2999 0.00 0.00
3000-3099 0.00 0.00
3100-3199 0.00 0.00
3200-3299 0.00 0.00
>3300 0.00 0.00

Injector Trim Calibration - 2806-E18 (JGBF5119U22626U)


Injector Serial Number File Version
Injector1 000000005A520681902F 0
Injector2 000000005A5206818426 0
Injector3 000000005A5206810195 0
Injector4 000000005A52068147D3 0
Injector5 000000005A5206820221 0
Injector6 000000005A52068150D3 0

Monitoring System - 2806-E18 (JGBF5119U22626U)


Description State Trip Point Delay Time
Engine Overspeed
Least Severe (1) On 2000 rpm 1 sec
Most Severe (3) Always On 2140 rpm 0 sec
Action Alert (2) Always On 2050 rpm 0 sec
High Boost Pressure
Action Alert (2) Always On None 5 sec
High Boost Pressure
Least Severe (1) On 43.5 psi 60 sec
High Engine Coolant
Temperature
Least Severe (1) On 219 Deg F 60 sec
Most Severe (3) Always On 226 Deg F 10 sec
Action Alert (2) Always On 221 Deg F 10 sec
High Engine Inlet Air
Temperature
Least Severe (1) On 167.0 Deg F 60 sec
Action Alert (2) Always On 172.4 Deg F 10 sec
High Fuel Temperature
Least Severe (1) On 140.0 Deg F 60 sec
Action Alert (2) Always On 154.4 Deg F 60 sec
Low Engine Oil
Pressure
Most Severe (3) Always On None 2 sec
Action Alert (2) Always On None 2 sec
Low Engine Oil
Pressure
Least Severe (1) On 44 psi 60 sec

You might also like