You are on page 1of 12
1 Permanent Way Standards EN 13450: 2002 EN 13674: 2003 EN 13481; 2012 EN 13146: 2012 EN 14587: 2007 EN 14730: 2006 EN 13230: 2009 EN 13232: 2003 EN 13848; 2003 Aggregates for railway ballast Railway Applications - Track — Rail Railway Applications — Track — Performance requirements for fastening systems Railway Applications — Track — Test methods for fastening systems Railway Applications — Track — Flash butt welding of rails Railway Applications — Track — Aluminothermic welding of rails Railway Applications - Track — Conerete sleepers and bearers Railway Applications - Track — Switches and crossings Railway Applications — Track — Track geometry quality @Ethan777 2020 Compiled from IES Railway Systems Handbook 2 Rolling Stock Standards Carbody EN 12663-1 Welding BS EN 15085, Bogie BS EN 13103 BS EN 13104 BS EN 13749 Doors BS EN 14752 Air Conditioning BS EN 14750-1 BS EN 14750-2 Battery IEC 60623 Railway applications. Structural requirements of railway vehicle bodies. Locomotives and passenger rolling stock (and alternative method or freight wagons) Railway applications. Welding of railway vehicles and components Railway applications. Wheelsets and bogies. Non-powered axles. Design method Railway applications. Wheelsets and bogies. Powered axles. Design method Railway applications, Wheelsets and bogies. Method of specifying the structural requirements of bogie frames Railway applications. Body side entrance systems for rolling stock Railway applications. Air-conditioning for urban and suburban rolling stock. Comfort parameters. Railway applications. Air-conditioning for urban and suburban rolling stock. Type tesis Secondary cells and batteries containing alkaline or other non-acid electrolytes — vented nickel — cadmium prismatic rechargeable single cells Electrical Equipment BS EN 50155 IEC 60077 Fire NFPA 130 NFF 16-101 NFF 16-102 Noise BS EN ISO 3095 BS EN ISO 3381 Vibration IEC 61373 Railway applications. Electric equipment used on rolling stock Railway applications. Electric equipment for rolling stock Standard for fixed guideway transit and passenger rail systems Railway Rolling Stock: Fire Behaviour, Choice of Materials Railway Rolling Stock: Fire Behaviour, Materials Choosing, Application for Electrical System Railway applications. Acoustics. Measurement of noise emitted by rail bound vehicles Railway applications. Acoustics. Measurement of noise inside rail bound vehicles Railway applications. Rolling Stock Equipment. Shock and vibration tests Testing & Commissioning IEC 61133 ®Ethan777 2020 Railway applications. Rolling Stock. Test of rolling stock on completion of construction and before entry into service Compiled from IES Railway Systems Handbook 3 Power Standards AC LV HY Switchgear lec 60947 lEC 62271 IEC 60376 IEC 61869-2 DC Switchgear IEC 61992 BS EN 50123 Rectifier and Inverter IEC 60148 Cables IEC 60228 IEC 60811 IEC 60230 IEC 60287 IEC 60332 (Part 1, 3) IEC 60754-1 IEC 61034 IEC 61442 IEC 60502-1 IEC 60502-2 Transformer IEC 60076 (Part 1-8) IEC 60214 IEC TR 60616 Low-voltage switchgear and controlgear High-voltage switchgear and controlgear Specification of technical grade sulfur hexafluoride (SFe) for use in electrical equipment Instrument transformers — Part 2: Additional requirements for current transformers Railway applications — Fixed installations ~ DC switchgear Railway applications — Fixed installations — DC switchgear Semiconductor converters — General requirements and line commutated converters Conductors of insulated cables Electric and optical fibre cables — Test methods for non-metallic materials Impulse tests on cables and their accessories Electric cables — Calculation of the current rating Tests on electric and optical fibre cables under fire conditions Test on gases evolved during combustion of materials from cables Measurement of smoke density of cables burning under defined conditions ‘Test methods for accessories for power cables with rated voltages from 6kV (Um = 7,2kV) up to 30kKV (Um = 36kV) Power Cables with Extruded insulation and their Accessories for Rated Voltages from 1 kV (Um = 1,2kV) up to 30kV (Um = 36kV) ~ Parl 1: Cables for rated voltages from 1kV (Um = 1,2kV) and 3 kV (Um = 3,6kV) Power Cables with Extruded insulation and their Accessories for Rated Voltages from 1 kV (Um = 1.2kV) up to 30kV (Um = 36kV) — Part 2: Cables for rated voltages ftom 6kV (Um = 7.2kV) up to 30 ky (Um = 36kV) Power transformers. Tap-changers Terminal and tapping markings for power transformers Ethan777 2020 Compiled from IES Railway Systems Handbook 3 4 Signalling and PSD Standards Main Standards BS 1376-1974 IEEE 1474.1-2004 IEEE 14742-2003 IEEE 1474.3-2008 IEEE 1474.4-2011 IEC 62267: 2009 IEC 62267: 2011 IEC 62280: 2014 IEC 62290-1: 2014 IEC 62425: 2007 IEC 62427: 2007 BS EN 50155: 2007 BS EN 50238-1: 2003 BS EN 50121- 2015 BS EN 50121-4; 2015 BS EN 50125-3: 2003 BS EN 50128: 2011 BS 376-2; 2015 NR BR 930 ISSUE 2: 1985 Specification for Colour of Light Signals IEEE Standard for Communications-Based Train Control (CBTC) Performance anc Functional Requirements IEEE Standard for User Interface Requirements in Communications-Based Train Control (CBTC) Systems IEEE Recommended Practice for Communications Based Train Control (CBTC) System Design and Functional Allocations IEEE Recommended Practice for Functional Testing of a Communications- Based Train Control (CBTC) System Railway applications ~ Automated urban guided transport (AUGT) — Safety requirements Railway applications — Automated urban guided transport (AUGT) - Safety requirements Part 2: Hazard analysis at top system level Railway applications - Communication, signalling and processing systems Safety related communication in transmission systems Railway applications - Urban guided transport management and command | control systems — Part 4: System principles and fundamental concepts Railway applications ~ Safety Related Electronic Systems for Signalling Railway applications - Compatiaility between ralling stock and train detection systems Railway applications ~ Electronic equipment used on rolling stock Railway applications — Compatibility between ralling stock and train detection systems. General Amended by Corrigendum, August 2010. Corrigendum, December 2014 Railway applications — Electromagnetic Compatibility. Part 3.2: Rolling Stock — Apparatus Applicable to signalling as signalling equipment mounted on the train Railway applications — Electromagnetic Compatibility. Part 4: Emission & immunity of the Signalling & Telecommunication Apparatus Railway applications — Environmental conditions for equioment — Part 3: equipment for signalling and telecommunications: Railway applications - Communications signalling and processing systems. Software for railway control and protection systems Railway signalling symbols. Specification for symbols for circuit diagrams Specification for miniature tractive armature DC Neutral Line Relay (Plug-in type) for railway signalling purposes ©Ethan777 2020 Compiled from IES Railway Systems Handbook 4 Signalling and PSD Standards General Standards IEEE Standard 80-2013 BS EN 13674-1 BS EN 61287-1: 2014 BS EN 50305: 2002 IEC 62236-3-2: 2008 IEC 62236-4: 2008 IEC 62278: 2002 IEEE 1482.1-2013 BS EN ISO 11064: 2000 - 2013 BS ISONEC 90002: 2014 Fire Standards BS 476-4: 1970 BS 476-7: 1997 SFSRTS: 2012 BS EN 12101-1: 2005+A1: 2006 BS EN 45645-1: 2013 BS EN 45545-2; 2013+A1; 2016 BS EN 45545-3; 2013 BS EN 45545-4; 2013 2013+A1; 2015 2013 BS EN 45545-7; 2013 @Ethan777 2020 IEEE guide for safety in AC substation grounding Railway applications — Track — Rail — Part 1: Vignole railway rails 46 kg/m and above Railway applications ~ Power convertors installed on board rolling stock. Characteristics and test methods. Railway Applications. RaiNway Rolling Stock Cables Having Special Fire Performance, Test Methods Railway applications ~ Electromagnetic Compatibility, Part 3.2: Rolling Stock — Apparatus Railway applications ~ Electromagnetic Compatibility. Part 4 Emission & Immunity of the Signalling & Teleconmunication Apparatus Railway applications ~ Specification and demonstration of reliability, availabilily, maintainability and safely (RAMS) IEEE Standard tor Rail Transit Vehicle Event Recorders Ergonomic design of control centres. Part 1: 2001 Principles for the design of control centres Part 2: 2001 Principles for the arrangement of control suites Part 3: 2000 Control room layout Part 4: 2013 Layout and dimensions of workstations Part 5: 2008 Displays and controls Part 6: 2005 Environmental reauirements for control centres Part 7: 2006 Principles for the evaluation of contro! centres Software engineering ~ Guidelines for the application of 1S0 9002: 2008 to computer software Fire tests on building materials and suuctures. Methods of test 10 determine the classification of the surface spread of flame of products Standard for Fire Safely in Rapid Transit System, Components for smoke and heat control systems. Specification for smoke curtains Code of practice for fire precautions in the design and construction of passenger carrying trains Compiled from IES Railway Systems Handbook 5 4 Signalling and PSD Standards Cable and Wire Standards IEC 60228: 2004 Conductors of insulated cables Electric cables — Tests on extruded over sheaths TEC Ruaee 2o0r with a special protective function Tests on electric and optical fibre cables under fire IEC 60332-1-1: conditions. Part 1-1 Test for vertical flame 2004+AMD1: 2015 CSV propagation for a single insulated wire or cable - Apparatus Tests on electric and optical fibre cables under fire conditions. Part 1-3 Test for vertical flame propagation for a single insulated wire or cable. — Procedure for determination of flaming droplets / particles IEC 60332-1-3: 2004+AMD1: 2015 CSV Test on Gases Evolved During Combustion of IEC 60754-1; 2011 Materials from Cables — Part 1; Determination of the Halogen Acid Gas Content IEC 60794 (1-76) Optical Fibre Cables Electric and optical fibre cables — Test methods for IEC 60811-201: 2012 non-metallic materials — Part 201: General tests — Measurement of insulation thickness Electric and optical fibre cables — Test methods for IEC 60811-202: 2012 non-metallic materials — Part 202: General tests — Measurement of thickness of non-metallic sheath Electric and optical fibre cables — Test methods for IEC 60811-203: 2012 non-metallic materials — Part 203: General tests — Measurement of overall dimensions Electric and optical fibre cables — Test methods for non-metallic materials — Part 501: General tests — IEC 60811-501: 2012 Mechanical tests — Test for determining the mechanical properties of insulating and sheathing compounds IEC 61034-1: 2005+AMD1: Measurement of smoke density of cables burning 2013 CSV under defined conditions — Part 1: Test apparatus @Ethan777 2020 Compiled from IES Railway Systems Handbook 4 Signalling and PSD Standards Electrical and IT Standards BS 1363-1: 1995+A4: 2012 CPS: 1998 BS EN 0076-1; 2011 BS EN 61558-1 2005+A1: 2009 Ethernet Standard IEEE 802.3 IEEE 802.11-2012 IEC 61000-5-2: 1987 IEC 61000-1-2: 2016 SS 551: 2009 13 A lused plugs, 13 A plugs, socket-outlets, adaptors and connection units, Specification for rewireable and non-rewireable Code of Practice For Electrical Installations Power transformers ~ Part 1: General Safety of Power Transformers Power Supplies Reactors and similar products, General Requirements and Tests. LOBASES LOMbis (1.25 MB/s) over thick coax — same as DIX except Type field is replaced by Length and an 802.2 LLC header follows the 802.3 header |EEE Standard for Information technology — Telecommunications. and information exchange between local systems and metropolitan atea networks—Specific requirements Part 11: Wireless LAN Medium Access Control (MAC) and Physical Layer (PHY) Specifications Electromagnetic compatbility (EMC). Part 5: Installation and mitigation guidelines ~ Section 2: Earthing and cabling Electromagnetic compatbility (EMC). Part 1-2: General - Methodology for the achievement of the functional safety of electrical and electronic equipment with regard to electromagnetic phenomena Code of practice for Earthing ISO/IEC 11801; 2002 (CONS-2-1) Information Technology. Generic cabling for customer premises. Mechanical and Building Standards BS EN 1991-1-1: 2002 BS EN 1991-1-7: 2006+A1: 2014 BS EN 1991-1-1: 2002 ISO 10816-1: 1995+A1: 2009 ISO 10816-1: 1995. BS EN ISO 1461: 2009 IEC 60529: 1989+AMD1: 1999+AMD2:2013 CSV Loading for buildings. Code of practice for dead and imposed loads Eurocode 1. Actions on structures. General actions. Densities, selt- weight, imposed load for buildings Mechanical vibration — Evaluation of machine vibration by measurements on non-rotating parts — Part 1: General guidelines, Hol Dip Galvanised Coatings on Fabricated tron and Steel Articles ~ Specifications and Test Methods Degrees of protection provided by enclosures (IP Code) ©Ethan777 2020 Compiled trom IES Railway Systems Handbook 5 C3 System Standards Communication Systems Standards SCDF Code of Practice for Fire Precautions in Rapid Transit Systems, 2017 Edition SCDF Code of Practice for Fire Precautions in Buildings Code of Practice for Emergency Voice Communication SS540 Systems in Buildings Standard for Fixed Guideway Transit and Passenger Rail NFPA 130 Systems Control Systems Standards Railway application — Communications, signalling and tor isco processing systems — Software for railway control and protection system CPFPRTS Code Of Practice For Fire Precautions In Rapid Transit (for ISCS, AMS) Systems, 2017 Edition Cyber-Security Systems Standards APTA SS-CCS- Securing Control and Communications Systems in Transit RP-001-10 Environments Part 1 APTASS-CCS- — Securing Contral and Communications Systems in Transit RP-002-13 Environments Part 1 APTA SS-CC-03- Securing Control and Communications Systems in Transit 15 Environments Part 3a APTA SS-CCS- Securing Control and Communications Systems in Transit RP-004-16 Environments Part 3b Railway applications - Communication, signalling and EN 50159 processing systems —Safety-related communication in transmission systems @Ethan777 2020 Compiled trom IES Railway Systems Handbook 6.1 Mechanical Services Standards Tunnel Ventilation System SCDF Code of Practice for Fire Precautions in Rapid Transit Systems, 2017 Edition $8638 Code of Practice for Electrical Installation $S551 Code of Practice for Earthing Environmental Control System $3530 Code of Practice for Energy Efficiency Standard for Building Services and Equipment $8553 Code of Practice for Air-conditioning and Mechanical Ventilation in Buildings SS554 Code of Practice for Indoor Air Quality for Air-conditioned Buildings SS638 Code of Practice for Electrica) Installation SS551 Code of Practice for Earthing SCDF Code of Practice for Fire Precautions in Rapid Transit Systems, 2017 Edition NEA Code of Practice for The Control of Legionella Bacteria in Coaling Towers NEA Code of Practice on Pollution Control BCA Green Mark Scheme Fire Protection System $8638 Code of Practice for Electrical Installation SS CP10 Code of Practice for Installation and Servicing of Electrical Fire Alarm Systems: SS CP48 Code of Practice for Water Services SSCP52 Code ot Practice for Automatic Fire Sprinkler System SS551 Code of Practice for Earthing SS575 Code of Practice for Fire Hydrant, Rising Mains and Hose Reel Systems. ss578 Use and Maintenance of Portable Fire Extinguishers SSEN3 Specification for Portable Fire Extinguishers NFPA 2001 Standard on Clean Agent Fire Extinguishing Systems SCDF Code of Practice for Fire Precautions in Buildings SCDF Singapore Fire Safety Engineering Guidelines (SFEG) BCA Code on Accessibility in the Built Environment SSO Chapter 109A Fire Safety Act SCDF Code of Practice for Fire Precautions in Rapid Transit Systems, 2017 Edition ®@Ethan777 2020 Compiled from IES Railway Systems Handbook 6.1 Mechanical Services Standards Lifts, Escalators and Travellators SS550 $8626 $8638 55546 88638 EN 81-20 EN 81-50 EN 115-1 ISO 18738-1 Code of Practice for Installation, Operation and Maintenance of Electric Passenger and Goods Lifts Code of Practice for Design, Installation and Maintenance of Escalators and Moving Walks Code of Practice for Electrical Installations. Code of Practice for Emergency Voice Communication Systems in Buildings Code of Practice for Energy Efficiency Standard for Building Services and Equipment Safety Rules for the Construction and Installation of Lifts — Lifts for the Transport of Persons and Goods Safety Rules for the Construction and Installation of Lifts — Examination and Tests Safety of Escalators and Moving Walks — Part 1: Construction and Installation Measurement of Ride Quality — Part 1: Lifts (elevators) BCA Code on Accessibility in the Built Environment SCDF Code of Practice for Fire Precautions in Rapid Transit Systems, 2017 Edition 6.2 Electrical Services Standards SS551 S531-1 8S531-2 SS531-3 $8563 SS535 SS555 58530 S638 NFPA 130 Code of Practice for Earthing Cote of Practice tor lighting of workplaces — indoor Code of Practice for lighting of workplaces ~ outdoor (Outdoor workplace safety Code of practice for the design, installation and maintenance of emergency lighting and power supply systems in buildings Code of practice for Installation, Operation, Maintenance, Performance and Consitructional Requirements of Mains Failure Standby Generating Systems Cade of practice for protection against lightning Code of Practice for Energy Efficiency Standard for Building Services and Equipment Code of Practice for Electrical Installations ‘Standard for Fixed Guideway Transit and Passenger Rail Systems SCDF Code of Practice tor Fire Precautions in Rapid Transit Systems, 2017 Edition SP Power Grid Guidelines/Requirements for transmission substation buildings @Ethan777 2020 Compiled from IES Railway Systems Handbook 10 7 Systems Assurance Standards EN 50126: 1999 EN 50126. IEC 62278: 2002 EN 50128: 2001 EN 50128: 2011 IEC 62279: 2002 IEC 62279: 2015 EN 50129: 2003 EN 50129: 2018 IEC 62425: 2007 EN 50159: 2011 IEC 62280: 2014 IEC 62267: 2009 IEC TR 62267-2: 2011 :2017 Railway applications — Specification and demonstration of reliability, availability, maintainability and safety (RAMS) Railway applications - Communications signalling and processing systems. Software for railway control and protection systems Railway applications - Communications signalling and processing systems. Safety related electronic systems for signalling Railway applications - Communications signalling and processing systems. Safety related communications in transmission systems Railway applications — Automated urban guided transport (AUGT) — Safety requirements. Railway applications — Automated urban guided transport (AUGT) — Safety requirements — Part 2: Hazard analysis at top system level UK Railway Safety Principles and Guidance UITP Position Paper: Preventing and Combating Fire in Metro Systems (November 2003) The International Railway Industry's Engineering Safety Management (iESM) Handbook @Ethan777 2020 Compiled from IES Railway Systems Handbook 1 8 Asset Management Standards ISO 55000: 2014 = Asset Management ISO 31000: 2018 —_ Risk Management EN 50126: 2017 IEC 60300-3-12 @Ethan777 2020 Railway applications — Specification and demonstration of reliability, availability, maintainability and safety (RAMS) Application Guide — Integrated Logistics Support Compiled from IES Railway Systems Handbook 12

You might also like