You are on page 1of 1

GENERAL NOTES:

FOOTING SCHEDULE
DEPTH(D) REINFORCEMENT
FOOTING SIZE (L x B)
in inch
b1 b2
F1 5'-0"x6'-0" 18" Y 10 @ 6"c/c Y 10 @ 6"c/c

CF1 5'-0"x10'-6" 18'' Y 10 @ 6"c/c Y 10 @ 6"c/c

EF1 5'-0"x5'-0" 18" Y 10 @ 6"c/c Y 10 @ 6"c/c

EF2 5'-0"x6'-0" 21" Y 12 @ 6"c/c Y 10@ 8"c/c


EF3 6'-0"x6'-0" 21" Y 12 @ 6"c/c Y 10 @ 6"c/c

3"
b2

COLUMN 8T12
12"

COL.DOWELS.

12"
L
N.GROUND LEVEL
12"

T10@8"C/C COL.STIRRUPS
(BOTHWAYS)
12"

12"
CONST.JOINT
GOOD FOR CONSTRUCTION
b1 b2
6'-0"

18"

T8@8"C/C
PROJECT TITLE:

3T12('U BAR') b1
3T12('U BAR')
D

DRAWING TITLE:
(IN PLAN) ECCENTRIC FOOTING TYPICAL
SECTION & REINF. DETAILS.
P.C.C IN 1:4:8 DEALT: CHECKED BY: DRAWING NO:
4"

(TYPICAL)
B SCALE: ISSUE DATE:
3"
3"

ARCHITECT:
B
TYPICAL SECTION OF 3"

ECCENTRIC FOOTING. TYPICAL PLAN OF STRUCTURAL CONSULTANT:

ECCENTRIC FOOTING.