Energent Microsteam® Turbine Power System Technical Overview

Microsteam Turbine Power System


®

PLC Control System with Color



Panel Display Power from Lost Energy

• Single-button startup
• Automatic synchronization
0/7%2K7E

 • Approved interconnection


• Unattended operation

• Hardwired safety trips

Pre-Wired, Factory-Tested Instrumentation
 and Controls
      
• Quick connect cables
34%!-,/!$,"(2
TOPSIG
• Plug-and-play operation
TOPSIG • Minimum installation costs
TOPSIG
Full Load Power Output
• 275 kWe @ 480 V, 60 Hz, 3 Phase
High Efficiency Radial Outflow Turbine • 275 kWe @ 400 V, 50 Hz, 3 Phase
• 80% at pressure ratio 2.5:1
• 70% at pressure ratio 5:1 Full Load Steam Heat Rate
• 3,690 Btu/kWh
Erosion Resistant Alloy Construction
• Tolerant of poor-quality steam Standard Maximum Inlet Pressure
• Titanium alloy rotor • 200 psig
• Stainless steel nozzle
Standard Minimum Discharge Pressure
High Efficiency Epicyclic Gearbox • 2 psig
• 97% at 300 kWe shaft
Steam Flow Rate
High Efficiency Induction Generator • 4,000 - 20,000 lb/hour
• 96% at 275 kWe
Typical Letdown Duty
Quiet Operation • 200/60 psig, 150/30 psig, 125/30 psig,
• 85 dBA untreated acoustically 125/15 psig

34" x 42" x 78" Vertical Shaft Long Life


• Installs through standard door • 15 Year Design
• Installation in congested equipment rooms

Energent Corporation
The Cryogenic Industries Group of Companies
2321 S. Pullman Street
ACD Cryo • ACD • CI-China • CI-Houston • CI-Korea Santa Ana, California 92705 USA
CI-Malaysia • Cosmodyne • CryoAtlanta • CryoCal Tel: +1.949.261.7533 x227
CryoCanada • Cryoquip • Cryoquip-Australia
Cryoquip-China • Cryoquip-East Coast • Cryoquip-Europe Web: www.energent.net
Cryoquip-Malaysia • Energent • PCS • Wittemann E-mail: info@energent.net
Energent’s Microsteam Turbine Power System efficiently ®

converts your wasted steam energy into electric power.


Steam Inlet Turbine System Advantages Performance
• High Turbine Efficiency: Under many conditions, the
Greater than 80% measured Microsteam® Turbine will pay for
Steam Outlet
in independent testing. itself in two to three years. As
an example, if the steam load is
• Reliable and Resistant to 13,500 lb/h and the pressure is
Corrosion and Erosion: reduced from 150 psig to 30 psig,
Titanium alloy construction the Microsteam® Turbine will
with novel design to clear any generate 275 kWe. The amount
particulates or contamination. of additional steam utilized to
Epicyclic Gear produce the power is 4 lb/kWe.
• Compact Power Package:
34” W x 42” L x 78” H. For service of 8,000 hours per
Allows easy access through year, with an average electricity
standard doors and fits in cost of $0.15/kWh and a steam
congested equipment rooms. cost of $0.015/lb, the net savings
Generator • Simple Installation: Controls would be calculated as follows:
Lube Oil Pump and electrical are pre-cabled NET SAVINGS = (275 x .15 –
and factory assembled—just 275 x 4 x .015) x 8,000 = $198,000
hook up the steam and electrical per year.
The Microsteam® Turbine is in commercial
operation and has been independently tested at interconnection.
the United Technologies Research Laboratory How much will you save?
to qualify the installation in the 7 World Trade • Simple operation: Single button Energent will survey your steam
Center Building.
startup and shutdown, unattended usage and conditions and, based
operation with automatic upon your electricity and steam
from the Microsteam® Turbine is
electrical synchronization and bills, provide a free estimate of
connected directly to the building
safety controls. your annual savings from installing
power panel with utility approved
protective relays, reducing the • User Friendly Control Panel: a Microsteam® Turbine.
purchased electricity. Separable from
Revolutionary. Innovative. Green. for progressive-minded facility power package is
steam equipment
All words which accurately managers who want to optimize an installed in parallel to The system is based on
with prefabricated
describe Energent’s Microsteam® existing resource, improve energy an existing PRV. When patented Euler turbine
quick connect
Turbine. This efficient, compact security, contain electricity costs, started, the turbine technology. In addi-
cables.
power system generates electricity and take an important step towards automatically takes tion to achieving the
from previously wasted steam creating a sustainable future. over the steam highest efficiency,
energy in buildings and plants. flow control from the rugged turbine
Any application having steam How It Works the PRV. When rotor is constructed A typical installation
to generate electricity
boilers or steam service with The operating principle is simple— the turbine is from corrosion from an existing steam

pressure reduction valves (PRVs) is energy otherwise dissipated by shut down, the resistant titanium system utilizing a PRV.
Connected in parallel
a candidate for this “plug and play” reducing the steam pressure in a PRV automatically alloy and has a design with the PRV, the high-
valve is converted to power by pressure steam source
preassembled system. These units resumes steam control. that readily handles poor feeds both the PRV
represent a significant opportunity the Microsteam® Turbine. The The power generated quality steam. and the steam turbine.

You might also like