Professional Documents
Culture Documents
Quiet Liner
Technical Data Sheet
Product Code: AQL
DESCRIPTION APPLICATION
“R” is a measure of the resistance to heat flow of a material of any Base glass fiber is non-combustible when tested to ASTM E84.
given thickness. (“R” = m2. °C/W or hr. ft2. °F/Btu.)
Facing Flame Smoke Fuel
T Spread Developed Contributed
R = where “T” = thickness
K and “K” or “ ” = thermal conductivity WGF 25 50 0
28
property requirements of the following specifications: 30000
24
• U.S. Federal Specification HH-I-545 B, TYPE I 20000
4000 10
550
0
500
0
400
8
350
2000
0
300
280
7
Friction Loss
260
0
240
0
220
6
200
0
0
180
0
160
1000
0
140
800
120
0
100
600 4
900
0
800
500
700
DIA
400
600
200
FPM
25 1 0.12 0.32 0.70 0.93 0.95 0.99 0.75 For velocities to 10 m/s: fasteners should start within 75 mm of the
AQL 240
50 2 0.27 0.69 1.01 1.07 1.06 1.05 0.95 upstream transverse edges of the liner and 75 mm from longitudinal
15 ½ 0.05 0.13 0.32 0.65 0.79 0.93 0.45 joints, and should be spaced at maximum of 300 mm from the corner
0.29 0.45 0.77 1.00 0.93 0.96 0.80
break. Elsewhere, they should be a maximum 450 mm on centers
AQL 320 25 1
except to be placed not more than 150 mm from a longitudinal joint
50 2 0.37 0.92 1.04 1.14 1.13 1.01 1.05
and 300 mm from a corner break.
15 ½ 0.05 0.12 0.29 0.51 0.68 0.80 0.40
AQL 480 25 1 0.22 0.52 0.73 0.98 1.02 1.00 0.80 For velocities from 10 to 20 m/s: fasteners should be placed as
50 2 0.30 0.85 1.03 1.07 1.06 1.00 1.00 above, except to be spaced at a maximum of 150 mm from the
25 1 0.06 0.19 0.62 0.83 0.90 0.95 0.65
corner break. Elsewhere, they should be a maximum of 400 mm
AQL 640 on centers except to be placed not more than 150 mm from the
50 2 0.21 0.75 1.00 1.00 1.00 0.95 0.95
longitudinal joint and 300 mm from the corner break. In addition to
the edge coating of transverse joints, longitudinal joints should be
Installation Recommendation for flexible blanket similarly coated with adhesive. For velocities from 20 to 30 m/s,
fasteners should be similarly spaced as for 10 to 20 m/s. In addition,
Quiet Liner Products are available in roll and board metal nosing should be installed to secure the liner at all upstream
types. The desired application length can be easily measured and transverse edges.
cut from the full size. Quiet Liner is applied to the interior
No maintenance is required. Quiet Liner have a high Acoustical Ceiling Panels ACP
resistance to accidental damage from knocks and handling
Blanket Insulation BKT
during installation and maintenance. Dimensionally stable
HD Series Blanket Insulation HDB
under varying conditions of temperature and humidity, rot-
proof, odourless, non-hygroscopic and will not sustain vermin or Board Insulation BD
fungus due to its inorganic and mineral compositions. Roof Insulation RI
Roof Deck Board Insulation RD
The product will maintain its thermal properties throughout the Cavity Wall Insulation CWI
lifetime of the construction and will not age. fibreglass is Pre-engineered Metal Building Insulation MBI
non toxic and not hazardous to health. Faced Duct Wrap FDW
Duct Liner DL
STORAGE Duct Liner Board DLB
To avoid moisture in the building construction, insulation Mechanical Board Insulation MBD
products stored outside must be kept dry. We recommend Heavy Density Pipe Insulation PI
products to be always stored in covered and dry areas. is Pipe Wrap Insulation PWI
not liable for the damage resulting from inadequate utilization, Thermal Insulating Wool TIW
loading and off loading and mishandling of its products. Quiet Liner AQL
Woven Facing AWF
WARRANTY Prefabricated Duct Board PDB
Authorized Distributor