Ahsan Afzaal Malik Refrigeration & AC – ME 436

1. A major pharmaceutical firm is establishing its production plants across 11 different cities
in Asia, and it needs to incorporate refrigeration systems for refrigerating medicines at a
temperature range of -30 to -15 C and also providing cooling to the habitable rooms at a
temperature range of 5 C to 10 C. Due to logistical reasons, the type of refrigerant used at
each location is different as well (details in Appendix A).

Design an actual vapor compression system with two stage compression and two
evaporators including intercooling and flash gas removal.

2. Assuming that the pharma firm is located in locations where exhaust gases of cement plants
are being wasted away, design a vapor absorption system (with heat exchanger) for
refrigerating during the months of March-August for only the habitable rooms using the
exhaust gas temperatures.

Appendix B lists the minimum requirements for each design. For any queries, you can contact
Engr. Ahsan Afzaal Malik for further clarifications until 18/12/2019.

Department of Mechanical Engineering, Air University, Islamabad, Pakistan


Ahsan Afzaal Malik Refrigeration & AC – ME 436

Appendix A
Part 2
Reg. No Name Part 1 Location Exhaust
Temp
1 160185 Arham Mustansar
2 160308 Omer Abdullah R22 Karachi 150 C
3 160378 Raja Areeb Sultan
4 160380 Uzair Shah Vardag
5 160383 Ali Raza R134a Islamabad 175 C
6 160386 Hamza Tariq
7 160388 Muhammad Talha
8 160390 Umar Ishtiaq R290 Riyadh 200 C
9 160392 Ahmad Tallah Aamer
10 160394 Muhammad Yawar Abbas
11 160398 Hamza Mahmood R404A Dhaka 135 C
12 160400 Ussama Hamid
13 160402 Syed Daud Ahmad Bukhari
14 160404 Umar Saeed R407C Bangkok 160 C
15 160410 Muhammad Saad
16 160412 Syed Murrawat Abbas
17 160416 Hammad Ahmed R410A Kuala Lumpur 190 C
18 160418 Ahmad Sabur Hassan
19 160422 Muhammad Wajih Ul Hassan
20 160424 Muhammad Amad Ul Haq R507 Jakarta 210 C
21 160428 Shah Rukh Mirza
22 160436 Kashif Ali
23 160460 Sheikh Shahmeer Hassan R600a Manila 125 C
24 160486 Muhammad Soban Akmal
25 160514 Farhan Tariq
26 160900 Muhammad Ali R717 Beijing 115 C
27 160903 Muhammad Abdullah
28 160905 Noman Nazar
29 160977 Muhammad Adnan Malik R718 Tashkent 105 C
30 161010 Huzaifa Shahid
31 161028 Hannan Hassan
32 161371 Zia Ahmed R744 Lahore 130 C
33 161372 Rafiullah

Department of Mechanical Engineering, Air University, Islamabad, Pakistan


Ahsan Afzaal Malik Refrigeration & AC – ME 436

Appendix B

Minimum Requirements

1. Classification and design of cycle.


2. T-s and p-h diagrams for all cycles.
3. Schematic diagram of cycles with state labeling and component names.
4. Comment on the working fluid used and its advantages/disadvantages.
5. For refrigerants that do not have a lower temperature range of -30 to -15 C on the p-h chart,
find out a different refrigerant and make use of that instead.
6. Comment on the case-specific differences between Vapor Compression System & Vapor
Absorption System.
7. For extra credit, design a vapor compression system with only one evaporator and compare
it to the vapor absorption system. Comment on which one should be utilized and why.
8. Write down references in APA format.
9. The entire report should be printed on white A4 sheets and then spiral-bound.
10. Use Excel to perform all calculations.
11. Due date is 23/12/2019 (1:00 PM) and viva will be held on 24/12/2019.