You are on page 1of 26

© Siemens AG 2019

Industrial Communication

SCALANCE X –
Industrial Ethernet Switches

Edition
Brochure 2019 siemens.com/switches
1
© Siemens AG 2019

Today's requirements on an industrial communication network are


manifold:

◾ Open and integrated communication across the entire company and


across company limits
◾ Uninterrupted flow of information from the sensor/actuator level all
the way to the company level
◾ Fast data exchange between the plant components
◾ Availability of information at any location
◾ Easy and consistent configuration and efficient diagnostics, simple
expansions and modernizations
◾ Integrated security functions which prevent unauthorized access

◾ Comprehensive consideration of cyber security measures in all


phases of the product lifecycle

With the Industrial Ethernet switches from Siemens you can meet
your specific challenges in a customized manner – our comprehensive
product portfolio always has the right switch for you.

2
© Siemens AG 2019

Content
CONTENT 03
Preface 04

Portfolio 06
UNMANAGED 10

Compact Switch Modules CSM 10

SCALANCE X-000 11

SCALANCE X-100 12

SCALANCE X-100 media conver 13

MANAGED LAYER 2 14

SCALANCE X-200 14

SCALANCE X-300 18

MANAGED LAYER 2/3 20

SCALANCE X-400 20

SCALANCE X-500 22

... and more 24

3
© Siemens AG 2019
PREEFACE

The Siemens Path to Digital Enterprise Totally Integrated Automation

Already today, Siemens relies on four-core components to With Totally Integrated Automation, Siemens is the only
realize the Digital Enterprise: Digital Enterprise Software supplier of an integrated product and system range for
Suite, Industrial Communication, Industrial Security and automation in all branches of industry – from incoming
Industry Services. On the way to Industry 4.0, industrial goods via the production process all the way to the
communication forms the basis for enabling the data flows outgoing goods, from the equipment, through the
needed along the added-value chains, which are required aggregation level and the industrial backbone all the way
for the combination of the virtual world and the real to connection to the office network. Siemens offers all
world. This way you can drastically reduce throughput components required for industrial communication: From
times with greatly increase flexibility in order to keep up industry-compliant communication processors all the
with the increasingly strong trend toward individualized way to network components – also available wireless, if
mass production while consistently reducing their necessary. To achieve the highest level of consistency of
consumption of energy and raw materials. the networks and seamless integration of the industrial
plants, different Industrial Ethernet switches are used.
Industrial communication networks: They are used for the structured networking of machines
the basis for digitalization and plants as well as for integrating them into the overall
corporate network. A graduated portfolio of switches all
Industrial communication is essential for any functioning the way to communication processors with integrated
automation. It provides the infrastructure and the required switch, offers the best solution for all types of industrial
network mechanisms for a company-wide data exchange. communication in any environment – from production in
This means: Along the entire value added chain in the clean rooms all the way to operation in rough outdoor
digital factory, from the field to the management level – applications.
regardless if wired or wireless – local or remote. Against
this background, it becomes obvious, on the one hand,
why efficient industrial networks can only be implemented
based on communication standards that ensure a high
level of openness and flexibility. And on the other hand,
it becomes clear that professional planning and implemen-
tation with in-depth application know-how are required.

4
© Siemens AG 2019

PREEFACE
Production vs. enterprise network High availability due to redundancy

Industrial communication differs fundamentally from the Production plants have been designed for and calculated
communication that is used in the office environment. In to ensure high availability. This means plant failures often
the office environment, many clients communicate with result in cost-intensive downtimes, high restart costs and
one server; there are no cross-connections between the loss of valuable data or materials. Redundant control
clients. This type of data transmission can cause systems or networks in redundant design offer protection
bottlenecks and delays when communication links are from automation system failures. To achieve the extremely
being established, when too many clients access a server fast response times required by industrial companies,
simultaneously. Siemens has for many years used standardized network
redundancy procedures that support reconfiguration times
In an industrial environment, these restrictions are not of a few milliseconds in the event of a fault.
acceptable for automation because the cyclic processing This is especially important for process automation in
programs need the latest input data to output which downtimes must be avoided at all costs. The
corresponding control commands to the components. benefits of these network redundancy processes are taken
The applications, communication relationships and advantage of here with the SIMATIC PCS 7 distributed
network structures must be individually adapted in this control system and PROFINET.
case – regardless if for plants in the industry, in the energy
sector, in traffic systems or infrastructures. For critical applications which must be fault-tolerant and
Plus the focus is on optimal utilization of the network prevent any delay in communication, Siemens offers
capacity and thus plants or machines, and on minimizing different solutions.
possible downtimes

5
© Siemens AG 2019
OVERVIEW

Portfolio
UNMANAGED

Compact Switch Modules SCALANCE X-000 SCALANCE X-100 SCALANCE X-200


CSM unmanaged unmanaged managed

More connection to SIMATIC Space-saving, cost-efficient and in- For a reliable network solution with For all network structures in machi-
dustry-compliant entry-level solution all equipment details ne-oriented applications up to
linked units

These unmanaged switches, based in The switches of the SCALANCE X-000 The switches of the SCALANCE X-100 The universal managed switches
design on LOGO!, SIMATIC S7-300/ET product line are unmanaged Industrial product line are rugged unmanaged of the SCALANCE X-200 product
200M or S7-1200, are used for Ethernet switches for implementing a Industrial Ethernet switches with line are well suited for setting up
interface extension of the products simple machine network with different port configurations – also line, star and ring structures up to
listed above. transmission rates of up to 1 Gbps. available as 19 "rack variant, cost- 1 Gbps. They support real-time
optimized box variant and media protocols such as PROFINET or
converter. EtherNet/IP. There are many
versions, for example, in IP65/67
degree of protection, in ultra-flat
design or for setting up bumpless
redundant network structures.

Highlights Unmanaged Switches

◾ Rugged, industry-compliant design


◾ The right version for each application
◾ Investment protection: Existing networks can be
extended with new products
◾ Wide range of usability in small or large
networks, even outside the control cabinet
◾ Avoiding additional training and introduction costs by
using standardized Ethernet technology
◾ Versions for connection of twisted pair
and fiber optic cables
◾ 5 year warranty on all SCALANCE products

6
© Siemens AG 2019

OVERVIEW
MANAGED LAYER 2 MANAGED LAYER 2/3

SCALANCE SCALANCE X-300 SCALANCE X-400 managed / SCALANCE X-500 managed /


X-200IRT managed managed Layer 3 Layer 3

Acting in hard real-time Convincing performance – Segmentation on all levels Structuring high-performance plants
modular and powerful and integrating them into the Office IT

The SCALANCE X-200IRT product High functionality and great Expandable at any time: You can structure your plant network
line includes compact switches flexibility: Thanks to its modular design, the with SCALANCE X-500 19" rack switches
for hard real-time requirements The SCALANCE X-300 products are SCALANCE X-400 product line offers as central components. As 19" rack
(isochronous real-time), for available as workgroup switches and maximum flexibility in the switch, these devices offer complete
example, in high-performance, 19" rack versions or in compact automation network–and high freedom in the selection of
isochronous Motion Control design and extend your plant performance (1 Gbps) with very connection media, transmission rates of
applications. These switches can networks with Gigabit Ethernet small space requirement – compact up to 10 Gbps and different redundancy
also be used to set up redundant power – even under harsh for DIN rail mounting as well. Large concepts. Connection your production
ring structures. conditions. production networks can be easily network to your Enterprise IT – for a
and clearly segmented in this way. network running from the machinery/
cells to your backbone layer.

Managed switches offer in addition

◾ A network for real-time (PROFINET and EtherNet/IP)


and standard TCP/IP, eliminating duplicate
infrastructure
◾ High network availability due to integrated
redundancy mechanisms (ring structures)
◾ Reduced downtimes by saving configuration data
◾ Integration into existing concepts for network security
through integrated security functions
◾ Configuration through WBM or CLI, local or remote
◾ Diagnostics through LEDs on the device, through
WBM or network management through SNMP with
SINEMA server
◾ Integration in the STEP 7 and PCS 7 engineering tools
◾ Integrated system diagnostics with PROFINET
◾ High network and machine availability

7
© Siemens AG 2019
OVERVIEW

Overview of the portfolio

Network components (SCALANCE X) CSM (Compact


Switch Module)
Operations Level

managed
X-500

XR-500
managed
X-400
Control Level

XM-400 PE-400
managed
X-300

X-300 XR-300WG XR-300/XR-300EEC


managed
X-200

XB-200 XC-200 XP-200/ XF-200BA XF-200


XP-200PoE EEC
X-200IRT
managed

X-200RNA X-200IRT X-200IRT XF-200IRT X-200P IRT


Field Level

PRO

LOGO! CSM CSM


unmanaged

CSM 1277 377


X-100

XB-100 XC-100 XR-100WG X-100


Media converter
unmanaged

G_IK10_XX_10255
X-000

X-000 XB-000

Portfolio of the Industrial Ethernet Switches SCALANCE X and Compact Switch Modules (CSM)

Product type Description

C Compact SCALANCE XB 2 0 5 - 3 LD

R Rack

M Modular Product line

F Flat Number of electrical ports

B Box Number of optical ports


System of SCALANCE name
assignment using SCALANCE
P Protected Name extension XB205-3LD as an example
8
© Siemens AG 2019

OVERVIEW
Functions and areas of application

Office features (VLAN)

ET 200M, S7-1200 or
Time synchronization

for SIMATIC S7-300/


Power-over-Ethernet
Diagnostic functions

Additional interface
Can be used under
enhanced ambient
Layer 3 / Routing

Real-Time (IRT)
Modular through

Gigabit Ethernet
media modules

to IEEE 1588
Isochronous
EtherNet/IP
PROFINET
19" design

Support of

conditions

LOGO!
X-500 Ɣ Ɣ Ɣ Ɣ Ɣ Ɣ Ɣ Ɣ Ɣ Ɣ
X-400 Ɣ Ɣ Ɣ Ɣ Ɣ Ɣ Ɣ Ɣ
X-300 Ɣ Ɣ Ɣ Ɣ Ɣ Ɣ Ɣ Ɣ Ɣ

G_IK10_XX_10302
X-200 Ɣ Ɣ Ɣ Ɣ Ɣ Ɣ Ɣ
X-100 Ɣ
X-000 Ɣ Ɣ
CSM Ɣ
Ɣ applies to selected versions

Industrial Ethernet switches SCALANCE X: Overview of the functions

Network setup through


Standard mechanical
Process automation

S7-1200 or LOGO!
Power generation

SIMATIC S7-300,
Office connection

plant engineering
Plant networking

Machine-internal
IIndustry-related

Unit networking
and distribution

Machinery and
applications

engineering
Wind farms

networking
Areas of application / Type of networks /
Requires
Powerful backbone network with very high
X-500 requirements on functionality / port density / ● ● ●
availability as well as interface to Office IT
Powerful plant network with high
X-400 ● ● ●
demand on functionality and availability
Large networks with high demand on
X-300 ● ● ● ●
functionality and availability
Networks with high demand on functionality
X-200 ● ● ● ● ● ● ● ●
and availability

G_IK10_XX_10301
X-100 Networks with low demand on functionality ● ● ● ●
Networks with low demand on functionality ● ●
X-000 and ruggedness
Networks or interface extension for SIMATIC
CSM ●
S7-300, S7-1200, LOGO!
● applies to selected versions

SCALANCE X Industrial Ethernet switches: Areas of application

9
© Siemens AG 2019
UNMANAGED

When do you use ... Variants


... CSM? LOGO! CSM CSM 1277 CSM 377

◾ For fast, simple connection of SIMATIC ◾ In LOGO! design ◾ In SIMATIC S7-1200 design ◾ In SIMATIC S7-300 design
S7-300/ET 200M, S7-1200 or LOGO! to ◾ Transmission rate ◾ Transmission rate ◾ Transmission rate
an electrical Industrial Ethernet network up to 100 Mbps up to 100 Mbps up to 100 Mbps
◾ For integration of small machines into ◾ IP20 degree of protection ◾ IP20 degree of protection ◾ IP20 degree of protection
existing automation networks
◾ Temperature range ◾ Temperature range ◾ Temperature range
◾ Stand-alone operation of the machines 0 °C to +55 °C 0 °C to +60 °C 0 °C to +60 °C
◾ For setting up small, local Ethernet
networks

Compact Switch Modules (CSM)


More connection to SIMATIC

◾ Multiplication of Ethernet Network topology


interfaces with LOGO! CSM and
position detection with
◾ Industry-compliant design, for
example, retaining collars for LOGO! CMR Satellite
PROFINET-compliant connector Mobile Cell
HIGHLIGHTS / FEATURES

IE FC RJ45 Plug for additional network phone


strain relief

SMS
✚ Affordable solution with SIMA-
TIC S7-300/ET 200M, S7-1200
or LOGO! GPS signal

LOGO!
BM
LOGO! LOGO!
G_IK10_XX_10383

LOGO!
CMR CSM TD
Position

Industrial Ethernet

siemens.com/csm

10
© Siemens AG 2019

UNMANAGED
When do you use ... Variants
... SCALANCE X-000/XB-000? SCALANCE X005 / X005EEC SCALANCE XB-000

◾ For implementing a simple machine ◾ 5x RJ-45 ports ◾ Up to 8x RJ45-Ports / 1x SC


networking or small Ethernet networks ◾ Metal housing ◾ Plastic housing
◾ For setting up small industrial line or star ◾ Transmission rate up to 100 Mbps ◾ Transmission rate of up to 1 Gbps
structures in machine or plant groups as
well as use in railroad and road traffic ◾ IP30 degree of protection ◾ IP20 degree of protection
◾ Installation in control cabinet, on standard ◾ Installation in control cabinet, control box
mounting rail, on SIMATIC S7-300 mounting ◾ Temperature range -10 °C to +60 °C
rail or for direct wall mounting
◾ Variants with AC 24 V (50/60 Hz) for use in
◾ Retaining collar building automation
◾ Temperature range 0°C to +65°C
◾ Temperature range -40 °C to +70 °C,
EN 50155 and e1/E1
(for SCALANCE X005EEC)

SCALANCE X-000 / XB-000 unmanaged


Simple, space-saving, for industrial use

Electrical and optical network ◾ Diagnostics on the device by


with SCALANCE XB005G means of LEDs (power, link sta-
and SCALANCE XC206-2SFP G tus, data communication)
SCALANCE
1000 Mbit/s XC206-2SFP G ◾ Integrated autocrossover
function makes the use of

HIGHLIGHTS / FEATURES
uncrossed connection cables
PC with possible
CP 1623 ◾ Automatic detection and
negotiation of data rate through
autosensing and
autonegotiation function
SCALANCE 1000 Mbit/s
XB005G
✚ Affordable introduction-level
1000 Mbit/s solution with easy handling

Code IP camera
reader

MV420
MV540

siemens.com/x-000
G_IK10_XX_10259

Conveyor belt

Industrial Ethernet (Twisted Pair)


Industrial Ethernet (Fiber Optic)

11
© Siemens AG 2019
UNMANAGED

When do you use ... Variants


... SCALANCE X-100? SCALANCE XB-100 SCALANCE XR-100WG SCALANCE XC-100 SCALANCE X108PoE

◾ For setting up ◾ Up to 24x RJ45 ports/ ◾ Short design for ◾ Up to 24x RJ45 ports/ ◾ 8x RJ45 ports, of which
electrical and/or 2x SC or ST/BFOC double-sided up to 2x SC or ST/BFOC 2x RJ45 with
optical line and ◾ Transmission rate up installation in 19" con- ◾ Transmission rate up Power-over-Ethernet
star structures in to 100 Mbps trol cabinets to 100 Mbps (PoE)
machine-oriented ◾ IP20 degree of ◾ Bis zu 24x RJ45-Ports, ◾ IP20 degree of ◾ Transmission rate to
applications protection 4x Comboports protection 100 Mbps
◾ When Power-over- ◾ Temperature range ◾ Transmission rate up ◾ Temperature range ◾ IP30 degree of
0 °C bis +60 °C to 100 Mbps -40 °C to +70 °C protection
Ethernet (PoE) is
required ◾ Redundant power ◾ Power supply DC 24 V ◾ Metal/plastic housing ◾ Temperature range
supply DC 24 V / or AC 100-240 V -20 °C to +60 °C
◾ Motor vehicle
AC 24 V (50/60 Hz) ◾ IP30 degree of ◾ Metal housing
approval E1
◾ Plastic housing protection (SCALANCE XC108
◾ PROFINET CC-A ◾ Temperature range only)
compliant 0 °C bis +60 °C

SCALANCE X-100 unmanaged


Full basic version for industrial use

Electrical and optical networks in industry and building automation

◾ Metal housing, also in


19" design
◾ Retaining collar Industrial Data Center

◾ Diagnostics on the device via


LEDs (power, link status, data
HIGHLIGHTS / FEATURES

traffic) and signaling contact


◾ Use of straight-through con-
necting cables thanks to inte-
grated autocrossover function
SCALANCE
◾ Automatic detection and XR526-8C
negotiation of data rate through
autosensing and
autonegotiation function SCALANCE Desigo CC SCALANCE
◾ Redundant power supply XM416-4C Management XR324-4M EEC
Station
SCALANCE SCALANCE
◾ Installation in control cabinet, XB205-3 Desigo XC124
on standard mounting rail, on Room SCALANCE
SIMATIC mounting rail or for Automation XC106-2
direct wall mounting Stations
SCALANCE SIPLUS
XB205-3 SCALANCE SIMATIC S7-1200
XB004-1
(Power AC 24 V) SIPLUS
Desigo SIMATIC ET200SP
Room
Automation SIMATIC SIMATIC
✚ Compact solution, good price/ SCALANCE
Stations MV540 MV420
performance ratio, unmanaged XB205-3
SCALANCE XB004-1
G_IK10_XX_10400

and still many ports in small (Power AC 24 V)


spac
Desigo Primary Conveyor belt
Automation Stations
Industrial Ethernet (Twisted Pair)
siemens.com/x-100 Industrial Ethernet (Fiber Optic)

12
© Siemens AG 2019

UNMANAGED
When do you use ... Variants
... SCALANCE X-100 media converter? SCALANCE X101-1 SCALANCE X101-1LD

◾ For the implementation of fiber-optic ◾ Implementation of 1x 10/100 Mbps RJ45 to ◾ Implementation of 1x 10/100 Mbps RJ45 to
cables on copper cable in Industrial 1x 100 Mbps ST/BFOC (multimode) 1x 100 Mbps ST/BFOC (single mode)
Ethernet networks ◾ Distances up to 5 kilometers ◾ Distances up to 26 kilometers
◾ For integration of remote stations in ◾ Temperature range -10 °C to +60 °C ◾ Temperature range -10 °C to +60 °C
glass fiber networks through fiber-optic
cables
◾ For bridging large distances

SCALANCE X-100 media converter


Customized conversion

Optical line topology with SCALANCE X101-1 and SCALANCE XC-100

◾ Conversion of electrical signals


into optical signals within
Industrial Ethernet
networks
◾ Retaining collar

HIGHLIGHTS / FEATURES
◾ Transmission rate up to
SIMATIC S7-1500 100 Mbps
with CP 1543-1
◾ Diagnostics on the device by
means of LEDs (power, link
status, data communication)
FDELQHW ◾ Redundant power supply
6,0$7,&6ZLWK SIMATIC S7-1200 6,0$7,&
,QGXVWULDO(WKHUQHW)&&DEOH[

&3$GYDQFHG with CP 1243-1 ,(3%/,1.31,2


✚ Very easy handling; enable
6&$/$1&(
;&
flexible and cost-efficient
combination of copper or fiber
optic cables
6&$/$1&( 6&$/$1&(
,()& ; ;&
0ELWV

5-
3OXJ 6&$/$1&(
;&
*B,.B;;B

352),%86 siemens.com/x-100
)&6WDQGDUG&DEOH
PROFINET/,QGXVWULDO(WKHUQHW 7ZLVWHG3DLU
PROFINET/,QGXVWULDO(WKHUQHW )LEHU2SWLF 6,0$7,&(7SUR

13
© Siemens AG 2019
MANAGED L2

When do you use ... Variants


... SCALANCE X-200? SCALANCE XF-200 SCALANCE XB-200

◾ For setting up Industrial Ethernet bus, ◾ Flat design ◾ Compact design


star and ring structures for high ◾ Plastic housing ◾ Plastic housing
network availability and increased
demand on functionality ◾ Retaining collar ◾ Up to 13x RJ45 / 3x ST/BFOC or SC
◾ For machine-oriented applications ◾ Up to 8x RJ45 / 2x ST/BFOC ◾ Distances up to 26 kilometers
◾ Distances up to 5 kilometers ◾ Console port
◾ Slanted cable outlet for easy pulling and ◾ Temperature range 0°C to +60°C
plugging connectors ◾ For PROFINET and EtherNet/IP applications
◾ Temperature range -40 °C to +60 °C

SCALANCE X-200 managed


Universal and convenient

Machine networking with PROFINET and SCALANCE XB-200

◾ Lightweight and rugged design


◾ Transmission rate up to
100 Mbps
Enterprise Resource
◾ Redundant power supply Planning (ERP)
◾ Installation in control cabinet,
HIGHLIGHTS / FEATURES

on DIN rail and wall mounting


Industrial Ethernet

✚ Increased plant availability due


to integration of configuration SIMATIC
and remote diagnostics S7-1500 mit
SCALANCE CP 1543-1
✚ High network availability W774-1 RJ45
✚ Space-saving in control cabinet,
control box SCALANCE SCALANCE SCALANCE
XB208 XB208 XB208 PROFINET

SIMATIC SIMATIC SIMATIC


RF680R RF615R RF615R

SIMATIC SIMATIC
RF650M RF650A
siemens.com/x-200
G_FS10_XX_01147

SIMATIC RF685R
SIMATIC SIMATIC
RF640A RF640A

14
© Siemens AG 2019

MANAGED L2
SCALANCE XC-200 SCALANCE XF-200BA

◾ Compact design ◾ Flat design with flexible bus adapter concept


◾ Metal/plastic housing ◾ Plastic housing
◾ Retaining collar ◾ Up to 4x RJ45 / 4x SC RJ
◾ Up to 24x RJ45 / 2x ST/BFOC, SC or SFP ◾ Temperature range -40 °C bis +70 °C
◾ Distances up to 200 km via SFPs
◾ NAMUR NE 21-konform, Conformal Coating,
◾ Integrated diagnostics for fiber optic (Fiber Monitoring) installation altitude up to 4000 m
◾ For PROFINET and EtherNet/IP applications
◾ Integration of S2 devices in a high-availability R1 system
◾ Full Gigabit versions (SCALANCE XC-200G) (SCALANCE XF204-2BA DNA “Y-switch” only)
◾ Temperature range -40 °C to +70 °C ◾ For EtherNet/IP applications (SCALANCE XF204-2BA only)
◾ NAMUR NE21-compliant, conformal coating, installation
◾ Support for VLAN (SCALANCE XF204-2BA only)
altitude up to 4000 m (SCALANCE XC-200EEC)
◾ Trackside railway approval EN 50121-4
◾ Support of virtual networks (VLAN)

Electrical and optical line and redundant ring structures using HRP standby coupling

◾ Compact design
◾ Transmission rate of up to
1 Gbps
Operator Stations Operator Stations
◾ Slot for C-PLUG removable
medium for easy device

HIGHLIGHTS / FEATURES
replacement in fault scenario
◾ Installation in control cabinet,
on standard mounting rail, on
SCALANCE SCALANCE SIMATIC mounting rail or for
XM408-8C XM408-8C direct wall mounting
Standby Standby ◾ Redundant power
Master 1000 Mbit/s Slave
supply

SCALANCE SCALANCE ✚ High network availability


SIMATIC SIMATIC XC206-2SFP XC206-2SFP
Field PG S7-1518F ✚ Use in process automation
100 Mbit/s

SIMOTION D
SCALANCE XC208 Axis grouping
SCALANCE XC208

PROFINET SIMOTION D
Axis grouping
SIMATIC SIMATIC SIMOTICS XP
ET 200SP ET 200SP siemens.com/x-200
G_IK10_XX_50725

SIMOTICS XP
PROFINET/Industrial Ethernet (Twisted Pair)
Industrial Ethernet (Fiber Optic)

15
© Siemens AG 2019
MANAGED L2

When do you use ... Variants When do you use ... Variants
... SCALANCE XP-200? SCALANCE XP-200 ... SCALANCE X-200RNA? SCALANCE X-200RNA

◾ For installation outside ◾ Up to 16x M12, of which 4x Power-over-Ethernet (PoE) ◾ For critical applications ◾ For seamless networks
the control cabinet ◾ Up to 4x 1 Gbps Ports (SCALANCE XP216 only) that require fault toler- with PRP/HSR
◾ Outdoors even in areas ◾ Metal housing with slim design ance in connection with ◾ Up to 4x RJ45 ports /
requiring a high degree ◾ High degree of protection IP65 system redundancy: For 2x FO
of protection and very short reconfigura-
◾ Temperature range -40 °C bis +70 °C ◾ IP20 degree of
demanding climatic tion times of the network
◾ NAMUR NE21-compliant, conformal coating, protection
ambient conditions installation altitude up to 4000 m ◾ In process automation or
power distribution plants ◾ Temperature range
◾ When space is restricted (SCALANCE XP-200EEC) -40°C to +60°C
◾ Support of virtual ◾ For PROFINET and EtherNet/IP applications
◾ Combo ports and
networks (VLAN) ◾ Slot for C-PLUG removable medium for easy temperature range
device replacement in fault scenario -40 °C to 70°C
◾ Variants for railway applications according to (for EEC variants)
EN 50155, EN 45545 (EEC variants)
◾ Motor vehicle approval e1/E1

SCALANCE X-200 managed


Universal and convenient

◾ Transmission rate SCALANCE XP-200


up to 1 Gbps trainside and trackside ANT 795-6MN
◾ Redundant power supply
SCALANCE
ANT793-8DJ W788-2 M12
✚ Very high network availability EEC
HIGHLIGHTS / FEATURES

Industrial Ethernet
✚ Easy commissioning, diagnos- (Trainside) SCALANCE
tics and device replacement XP208PoE EEC
✚ Easy coupling of networks SCALANCE
✚ For harsh ambient conditions W788-2 M12
EEC SCALANCE
✚ Use in hazardous areas XP216PoE EEC

Tunnel

Communication
Server

Trainguard SCALANCE
Train Control XR552-12M
siemens.com/x-200

Workstations

16
© Siemens AG 2019

MANAGED L2
When do you use ... Variants
... SCALANCE X-200IRT? SCALANCE X-200IRT SCALANCE XF-200BA IRT SCALANCE X-200IRT PRO

◾ For PROFINET applications ◾ For hard real-time ◾ Flat design with flexible ◾ For hard real-time
with IRT requirements ◾ Up to 4x RJ45 / bus adapter concept ◾ Up to 4x RJ45 /
(Isochronous Real Time) 4x ST/BFOC or SC RJ ◾ Plastic housing 3x SC RJ Push-Pull
◾ For high-speed Motion Control ◾ IP30 degree of protection ◾ Up to 4x RJ45 or ◾ With PROFINET-compliant
applications 4x SC RJ push-pull connection
◾ Bumpless redundancy
◾ For plant concepts without control (MPRD) ◾ 2x bus adapter slots technology
cabinet ◾ High degree of protection
◾ Temperature range ◾ Support of PROFINET with
◾ For seamless switching in case of -25°C to +50°C IRT real-time capability IP65/67
redundancy ◾ Bumpless redundancy
◾ Bumpless redundancy
◾ For high-precision applications (MPRD) (MPRD)
(isochronous mode) ◾ Temperature range
◾ Temperature range
-40 °C bis +70 °C -25 °C to +60 °C

◾ Transmission rate 10/100 Mbps


◾ Redundant power supply

ANT793-8DJ ANT793-8DJ ANT793-8DJ


✚ High network availability

HIGHLIGHTS / FEATURES
✚ Hard real-time
ANT 795-6MN
SCALANCE ✚ Bumpless redundancy (MRPD)
W788-2 M12 for seamless switches
EEC SCALANCE ✚ For harsh ambient conditions
SCALANCE
W788-2 M12
W788-2 M12 EEC ✚ Rugged, industry-compliant
SCALANCE EEC
XP216PoE EEC device connector
Industrial Ethernet
(Trainside)
✚ Implementation of isochronous
Tunnel Tunnel applications
SCALANCE
✚ PROFINET CC-C compliant
XP208PoE EEC

Industrial Ethernet (Trackside)

Infotainment
Server
siemens.com/x-200
G_IK10_XX_50702

Content
Workstation

17
© Siemens AG 2019
MANAGED L2

When do you use ... Varianten


... SCALANCE X-300 or SCALANCE X-300 SCALANCE XR-300WG
SCALANCE XR-300 managed?

◾ For large networks with high demand on ◾ For high-speed plant networks ◾ Short design for double-sided installation in
functionality and availability ◾ Up to 20x RJ45 / 4x ST/BFOC, SC or SFP 19" control cabinets
◾ For installation in a 19" control cabinet ◾ Transmission rate of up to 1 Gbps ◾ Up to 24x RJ45-ports, 4x comboports
(SCALANCE XR-300) ◾ Overall height 1 HU
◾ Distances up to 200 kilometers
◾ Temperature range -40 °C to +70 °C ◾ Transmission rate of up to 1 Gbp
◾ Up to 2x 2-port media modules ◾ DC 24 V or AC 100-240 V
(for SCALANCE X308-2M) ◾ IP30 degree of protection
◾ 2 ports with Power-over-Ethernet ◾ Temperature range
(for SCALANCE X308-2M PoE) -40 °C to +70 °C
◾ Railway approval in accordance with ◾ Switchable between PROFINET and
EN 50155 and e1/E1 (for SCALANCE X308-2TS) EtherNet/IP diagnostics

SCALANCE X-300 managed


Compact high performance
Integration of control cabinets with SCALANCE XC-200 into an optical Gigabit ring, under adverse ambient
conditions with SCALANCE XR-300EEC

◾ Compact design
◾ Rugged metal housing PC
◾ Retaining collar SCALANCE XM416
◾ Support of virtual networks with BUS ANALYZER
(VLAN) AGENT XM400
HIGHLIGHTS / FEATURES

◾ Redundant power supply

✚ High performance and network


availability
✚ Use in railway applications Control cabinet Control cabinet
✚ No need for additional network
SCALANCE SCALANCE
components and cabling
XC206-2SFP G XC206-2SFP G
✚ Easy network configuration and
network extension
✚ Flexible adaptation to different
network structures

SIMATIC
ET 200SP
SIMATIC HMI SIMATIC S7-1500 SIMATIC
siemens.com/x-300 TP700 Comfort ET 200SP
SIMATIC S7-400 with
CP 443-1 Advanced

PROFINET/Industrial Ethernet (Twisted Pair)


PROFINET/Industrial Ethernet (Fiber Optic)

18
© Siemens AG 2019

MANAGED L2
Accessories
SCALANCE XR-300 SCALANCE XR-300EEC Media modules and
plug-in transceivers

◾ For modular network configuration ◾ For harsh ambient ◾ 2-port media modules
◾ Up to 12x 2-port media modules conditions ◾ Electrical variants:
◾ 8x RJ45- ports with ◾ Up to 4x 2-port media modules RJ45, M12, VD (Variable Distance)
Power-over-Ethernet ◾ Overall height 1 HU ◾ Optical versions:
(for SCALANCE XR324-4M PoE) ◾ Transmission rate of up to 1 Gbps SC, ST/BFOC
◾ Overall height 1 HU ◾ Distances up to 200 kilometers ◾ Variants for plug-in transceivers
◾ Transmission rate of up to 1 Gbps ◾ Temperature range ◾ Temperature range
◾ Distances up to 200 kilometers -40 °C to +70 °C -40 °C to +70 °C
◾ Temperature range -40 °C to +70 °C ◾ Approval to IEC 61850-3 ◾ Variants with conformal coating
◾ EN 50155 and e1/E1
(for SCALANCE XR324-12M TS and
XR324-12M PoE TS)

SCALANCE XR-300 managed


Flexible high performance

◾ Rugged metal housing


SINEC PC ◾ Support of virtual networks
NMS Operation (VLAN)
SCALANCE ◾ Modular with media modules
◾ Redundant power supply

HIGHLIGHTS / FEATURES
XM416-4C

SCALANCE
XR324-4M EEC ✚ High performance and network
availability
✚ Use in railway applications
Control cabinet Control cabinet ✚ Easy network configuration and
SCALANCE network extension
SCALANCE XR328-4C WG XP208PoE ✚ Flexible adaptation to different
EEC network structures

SCALANCE
W788-1
M12 EEC
SIMATIC SIMATIC SIPLUS
ET 200SP CPU ET 200SP ET 200S
with CP 1543SP-1
siemens.com/x-300
G_IK10_XX_10215

SIMATIC S7-400 with SIPLUS S7-400 SIMATIC


CP 443-1 Advanced PC ET 200SP CPU
with CP 1543SP-1

19
MANAGED L2/3
© Siemens AG 2019

When do you use ... Variants Extension modules


... SCALANCE XM-400 SCALANCE XM-400 Port Extender
managed?

◾ For high-performance ◾ For flexible plant networks ◾ 8x RJ45 ports with PE408
plant networks ◾ 8x or 16x RJ45 ports ◾ 8x RJ45 ports with Power-over-Ethernet
◾ For communication in Layer 3 networks ◾ Can be extended up to 24x ports with PE408 PoE
(with port and function extender) ◾ 8x SFP slots with PE400-8SFP
◾ 4x or 8x combo ports, optionally RJ45 or ST/ ◾ Temperature range
BFOC, SC or SFP -40 °C to +70 °C
◾ Transmission rate of up to 1 Gbps
◾ Temperature range
-40 °C to +70 °C

SCALANCE X-400 managed


Powerful networking of plants

◾ Compact design
◾ Retaining collar Operator Station (OS) OS SIMATIC IT SIMATIC Batch
◾ Can be extended with modules
◾ Optical connection of layer 3
functionality
HIGHLIGHTS / FEATURES

◾ Installation in control cabinet,


on standard mounting rail, on
SIMATIC mounting rail
SCALANCE Terminal bus
◾ Support of virtual networks
XM408-8C
(VLAN)
◾ Console port 1000 Mbit/s
◾ Redundant power supply

✚ High performance and network


availability
SINEC OS Server
✚ Easy expansion of the network
NMS Operation (redundant)
1000 Mbit/s

SCALANCE
XM408-8C
siemens.com/x-400 Plant Bus

SCALANCE 1000 Mbit/s


XM408-8C

SCALANCE
XM408-8C
PROFINET/Industrial Ethernet (Twisted Pair)
PROFINET/Industrial Ethernet (Fiber Optic)
Structuring of a network with
20 SCALANCE XM-400
MANAGED L2/3
© Siemens AG 2019

Accessories
Power Supplies Plug-in transceiver Pluggables

◾ Power supplies for 54 V DC supply for ◾ Optical connection to cables with LC ◾ Optical connection to existing
Power-over-Ethernet according to connectors cables with SC or ST/BFOC connectors
IEEE 802.3at ◾ Transmission rates 100 or 1000 Mbps ◾ Transmission rates 100 or 1000 Mbps
◾ Input current 24 V DC for PS924 PoE ◾ Can be used in conjunction with SCALANCE ◾ Can only be used in conjunction with
◾ Input current 85 - 265 V AC for PS9230 PoE XM408-8C, XM416-4C and PE400-8SFP SCALANCE XM408-4C
◾ High power for connected terminal devices ◾ Temperature range ◾ Temperature range
possible (up to 30 watts) -40 °C to +85 °C -40 °C to +85 °C
◾ Temperature range ◾ Variants with conformal coating
-40 °C to +70 °C

Accessories

◾ Port extender in design of


OS Engineering Station (ES)
SCALANCE XM-400

✚ Expansion of the network


without tools

HIGHLIGHTS / FEATURES
✚ Extension during operation
(hot swappable)
✚ No need for additional network
SCALANCE components and cabling
XM408-8C
✚ Space-saving design
IPC with ✚ Distances up to 200 kilometers
CP 1623 SIMATIC
ET 200M

Redundant control -
OS Server S7-400H
(redundant)

SC
SCALANCE
X
XM408-8C
siemens.com/x-400

Redundant control -
S7-400H
SCALANCE
XM408-8C
G_IK10_XX_50804

SIMATIC
ET 200M

PROFIBUS

21
© Siemens AG 2019
MANAGED L2/3

When do you use ... Variants


… SCALANCE XR-500? SCALANCE XR524-8C SCALANCE XR526-8C

◾ For structuring high-speed production ◾ For large scales (24 ports) ◾ For large scales (26 ports)
networks with connection to ◾ Overall height 1 HU ◾ Overall height 1 HU
the Enterprise IT
◾ 24x RJ45 ports with transmission rates of up ◾ 2x SFP+ ports with 10 Gbps
◾ For transmission of high data rates to 1 Gbps
(10 Gbps) ◾ 26x RJ45 ports with transmission rates of up
◾ 8x combo ports, optionally RJ45 or SFP to 1 Gbps
◾ Temperature range ◾ 8x combo ports, optionally RJ45 or SFP
0 °C to +50 °C ◾ Temperature range
0 °C to +50 °C

SCALANCE X-500 managed


Structuring high-performance systems and connecting corporate IT systems

◾ 19" design in different height


DMZ
units (HU)
◾ Rugged metal housing
Core Layer

◾ Support of virtual networks


(VLAN)
HIGHLIGHTS / FEATURES

◾ Modular with media modules or


SFP and SFP+ plug-in
transceivers
◾ Redundant power supply Industrial Ethernet
◾ Console port (Fiber Optic) – 10 GBit/s
SCALANCE XR500

SCALANCE XR526-8C
Distribution Layer

✚ Very high performance and


network availability
✚ Granular network extension to Factory hall 1

10 Gbps during operation SCALANCE


XM416-4C
✚ Flexible adaptation to different SCALANCE Industria
network structures XC206-2SFP (Fiber Optic)

SCALANCE XC206-2SFP

Machine 1
siemens.com/x-500 SCALANCE SC642-2C
SIMATIC S7-150
SCALANCE W77
CM 1542-1
SCALANCE PROFINET/ CP 1543-1
XB216 Industrial Ethernet
Access Layer

Connection of automation networks


Automated
to the Office IT over the guided
22 Industrial Ethernet backbone vehicles
SIMATIC MindConnect ET 200SP TP 1200
S7-1500 Nano S
© Siemens AG 2019

MANAGED L2/3
Accessories
SCALANCE XR528-6M SCALANCE XR552-12M Media modules Plug-in transceiver

◾ For large scales ◾ For very large scales (52 ports) ◾ 4-port media modules ◾ Cables with LC connectors
(28 ports) ◾ Up to 12x 4-port media modu- ◾ Electrical and optical variants ◾ SFP plug-in transceiver with
◾ Up to 6x 4-port media modules les for electrical and ◾ Can be used in SCALANCE transmission rates
for electrical and optical optical connections XR552-12M and XR528-6M 100 or 1000 Mbps
connections ◾ Overall height 3 HU ◾ SFP+ plug-in transceiver with
◾ Temperature range
◾ Overall height 2 HU ◾ 4x SFP+ ports with 10 Gbps 0 °C to +60 °C 10 Gbps
◾ 4x SFP+ ports ◾ 48 ports with transmission ◾ Temperature range
with 1 or 10 Gbps rates of up to 1 Gbps -40 °C to +85 °C
◾ 24 ports with transmission rates ◾ Temperature range ◾ Variants with conformal
of up to 1 Gbps 0 °C to +60 °C coating
◾ Temperature range
0 °C to +60 °C

([WHUQDO
Firewall
:$15RXWHU &RUH
HIGHLIGHTS / FEATURES

MindSphere

HIGHLIGHTS / FEATURES
,QWHUQHW
Firewall/IOS Firewall/IOS

Industrial Data Center


Firewall
SCALANCE XR552-12M SCALANCE XR552-12M SINEMA
Remote
SCALANCE XR528-6M Connect

SCALANCE XR526-8C
Firewall SCALANCE
XR528-6M
SCALANCE
Factory hall 2 X308-2M Server + SINEC NMS Control
SCALANCE SCALANCE
XC206-2SFP Industrial Ethernet XC206-2SFP
al Ethernet (Fiber Optic) – 1 GBit/s
SCALANCE
– 1 GBit/s
XC206-2SFP

SINEC SCALANCE XC206-2SFP SINEC


NMS Operation NMS Operation

Machine 2 Machine 3
SCALANCE SC642-2C
00F with
74-1

MindConnect
ET 200SP TP 1200 Nano PROFINET / Industrial Ethernet
SCALANCE
XB216

PROFINET/Industrial Ethernet

RCoax

23
G_IK10_XX_10425

SIMATIC ET 200SP TP 1200 SCALANCE


CALANCE W722-1, ET 200SP CPU, CP 1543SP-1 S7-1500F W788-2 M12
© Siemens AG 2019
... and more

Switches ... and more


C-PLUG/KEY-PLUG SIMATIC NET Selection Tool

Update your network components to minimize plant The SIMATIC NET Selection Tool is your reliable wizard for
downtimes. selecting Industrial Ethernet switches. The selection can
either take place directly from the product portfolio or by
The KEY-PLUG removable medium allows you to enable specifying the technical requirements as well as by type of
additional functions especially for industrial use. application. Integrated configurators help you select
modules and accessories as well as during checking of
The C-PLUG is used for fast and easy device replacement correct function and during ordering.
when an error occurs through automatic backup of
siemens.com/snst-standalone
configuration data.

The KEY-PLUG supports the C-PLUG functionality and is also


used for extending or retrofitting additional device
functions, for example, enabling software extension to
Layer 3 switching (routing) for SCALANCE XM-400 and
SCALANCE XR-500.
siemens.com/plugs

24
© Siemens AG 2019

... and more


FastConnect cabling system Network management
SINEC NMS

Can be assembled on site – easy, fast and without errors. The degree of networking, scope of data, and complexity
With FastConnect, Siemens has developed a sophisticated of network structures are constantly increasing. This calls
fast connection system for cables, connectors and for a powerful and future-proof network management sys-
assembly tools that you can use to make changes quickly tem to pave the way for the digital transformation in
and without errors on site. FastConnect is available for industry.
PROFINET/Industrial Ethernet and PROFIBUS, for RJ45, M12
or Sub-D/RS-485. And also for Fiber Optic (fiber optic The new SINEC NMS network management system has
cables) ST/BFOC, SC, SC RJ and LC for different lengths. been specially designed for the high demands placed on
industrial communication networks in the Digital Enter-
siemens.com/fastconnect
prise. It is capable of mastering these challenges in all
sectors.

For example, through comprehensive detection and moni-


toring of the entire network, rule-based configuration of
the network infrastructure, and central firmware manage-
ment with topology-based rollout. Thanks to its distributed
approach, SINEC NMS makes it easy to adapt flexibly to the
requirements of all types of plant networks.
siemens.com/sinec-nms

25
© Siemens AG 2019

Siemens AG
Process Industries and Drives Division
Security information
Process Automation Siemens provides products and solutions with industrial
Postfach 48 48 security functions that support the secure operation of
90026 Nürnberg
Germany
plants, systems, machines and networks.
In order to protect plants, systems, machines and networks
© Siemens AG 2019
against cyber threats, it is necessary to implement – and
Subject to change without prior notice continuously maintain – a holistic, state-of-the-art indus-
Article no. 6ZB5530-1AN02-0BB2 trial security concept. Siemens’ products and solutions
IC-FPN9Z-DIPAP-XXXX-27 / Dispo 26000 constitute one element of such a concept.
BR 0119 3. WÜ 26 En
Printed in Germany Customers are responsible for preventing unauthorized
access to their plants, systems, machines and networks.
Such systems, machines and components should only be
The information provided in this brochure contains merely general
descriptions or characteristics of performance which in case of actual
connected to an enterprise network or the internet if and
use do not always apply as described or which may change as a result to the extent such a connection is necessary and only
of further development of the products. An obligation to provide the when appropriate security measures (e.g. firewalls and/or
respective characteristics shall only exist if expressly agreed in the network segmentation) are in place.
terms of contract. Availability and technical specifications are subject
to change without notice. For additional information on industrial security measures
All product designations may be trademarks or product names that may be implemented, please visit
of Siemens AG or supplier companies whose use by third parties https://www.siemens.com/industrialsecurity.
for their own purposes could violate the rights of the owners.
Siemens’ products and solutions undergo continuous
development to make them more secure. Siemens strongly
recommends that product updates are applied as soon as
they are available and that the latest product versions are
used. Use of product versions that are no longer supported,
and failure to apply the latest updates may increase
customer’s exposure to cyber threats.
To stay informed about product updates, subscribe to the
Siemens Industrial Security RSS Feed under
https://www.siemens.com/industrialsecurity.

siemens.com/switches

You might also like