ABSTRACT
In this work an equivalent electrical circuit to estimate the PV/T solar collector producibility is presented. The
solution of the circuit allows evaluation of thermal and electrical power produced by the collector. The electrical
circuit is modified according to whether the problem is solved in stationary or transient conditions. As regards
the stationary approach, two different circuits can be schematized: the first allows evaluation of the magnitudes
at different points along the motion direction of the fluid; the resolution of the second electric circuit allows
direct evaluation of the average magnitudes between the inlet and outlet collector section. With the transient
model, instead, it is possible to estimate the behaviour of the collector by adding, to the previous circuit, a
capacitor of capacity equal to those of the thermal collector. Obviously, when the transient condition is
exhausted, the various determined quantities are identical to those measured in stationary conditions. Finally, the
study shows that the electrical circuit used for this type of collector is similar to that of the solar thermal
collector, with the difference that some circuit components also contain electrical quantities.
843
where Gc is the global radiation incident on the collector Since, to estimate the average useful power between inlet
plane, Ac is the absorbing surface area, (τα) is the effective and outlet it is necessary to solve the circuit and then
product between the cover transmission coefficient and the calculate the mean arithmetic value between the magnitudes
plate absorption coefficient, Qu is the thermal power given to evaluated in the two extreme sections, it was considered
the heat transfer fluid, Qp is the power lost by radiation and appropriate to schematize a second electrical circuit in which
dU p the magnitudes estimated are already averages, so as to make
convection, while is the power accumulated by the the immediate calculation. With the new circuit the analysis
dt
can be extended to more irradiation values (time values) on
plate.
the plane of the collector and, therefore, to perform the
estimation of the useful daily power.
2.1 Stationary thermal analysis
The electrical circuit of Figure 2, in this case, describes the
following thermal balance:
Setting the solar irradiance absorbed with S [S=Gc·(τα)],
the plate temperature with Tp and the fluid temperature with
Tf, Eq. (1), written in stationary conditions, for an element of T f Tin T p Ta T f Tin T p Ta
S (3)
area (W·dx), becomes: Ac 1 R2 R1
2m c p
T p x Ta T p x Ta
Uc
m c p dT f x dT f x
S Cf (2)
W dx 1 dx Re Tout Tin
Uc with the hypothesis: T f
2
where Tin and Tout represent, respectively, the inlet and outlet
where Cf is the hourly specific thermal capacity of the fluid, temperature of the fluid.
W is the collector width, Uc is the global heat exchange
coefficient between plate and external air and Ta is the
external air temperature.
Referring to Eq. (2) it is possible to schematize the
equivalent electric circuit shown in Figure 1.
844
3. HEAT BALANCE EQUATION OF A PV/T With simple algebra [3, 7], Eq. (8) can be rewritten as:
COLLECTOR
1 (Ta TR ) log10 Gc
Hybrid thermal-photovoltaic solar collectors [3], or PV/T, Gc 1 R
are systems able to convert simultaneously solar energy into
electricity and heat. A PV/T collector, generally, is composed (9)
of a coil, or of a bundle of tubes in parallel, in which the heat dT f x
transfer fluid circulates and above which the photovoltaic Cf
dx
T p x Ta U c R Gc
module is glued, by means of a highly conductive glue, or
laminated; they can be glazed or uncovered. Figure 4 shows
an assembly drawing of a PV/T glazed collector. Setting:
1 (Ta TR ) log10 Gc
S Gc 1 R
~
(10)
Gc 1 a S 1 a
~ S
U c U c R Gc U c R (11)
where ηa is the electrical efficiency of the collector when the
cell temperature is equal to external air temperature.
Eq. (9) becomes:
~
dT f x T p x Ta
dT f x T p x Ta (12)
Figure 4. Assembly drawing of a PV/T collector [3] S Cf Cf ~
dx 1 dx Re
~
Uc
The instantaneous heat balance equation of the absorber
plate, in the case of the PV/T collector, is described by Eq.
This last expression, with the change of variables
(5).
introduced, is identical to Eq. (2) relative to the traditional
thermal collector.
dU p
Gc Ac Qu Q p Qe
~ Referring to Eq. (12) it is possible to schematize the
(5)
dt equivalent electric circuit shown in Figure 5.
The electrical circuit of Figure 5 is similar to that of Figure
where, the useful power transferred to the heat transfer fluid 1, with the difference that some circuit variables also contain
~ the electrical component in accordance with Eqs. (10) and
is indicated with Q u while Qe represents the useful electrical
(11).
power generated.
Qe
qe e Gc (6)
Ac
845
dT f x Taking into account the change of variables, Eqs. (10) and
qu x C f (13) (11), the electrical circuit of Figure 6, relative to the PV/T
dx collector, is similar to that of Figure 2 corresponding to the
traditional thermal collector.
Tp x T f x
qu x ~ (14)
Rf 3.2 Transient thermal analysis
~ x
Re RC f The circuit that describes Eq. (20) is shown in Figure 7;
Tp x Tin T ' 1 e (16) also in this case, the electric circuit is similar to that of Figure
R 3 relative to the traditional thermal collector.
where:
~~
T ' Ta Tin S Re
~ ~
R Re R f
Integrating Eqs. (15) and (16) over the entire length of the
plate, the equations for the calculation of the plate and fluid
average temperature and, therefore, the equations to calculate
the thermal and electrical average powers are obtained:
qu FR S Uc Tin Ta
~ ~ ~
(17)
Figure 7. Equivalent electric circuit in transient conditions,
S~
~
qe aGc R Gc ~ 1 FR Tin Ta FR
~
(18) PV/T collector
Uc
4. MATLAB RESOLUTION
~ T f Tin
T p Ta
T f Tin T p Ta
S ~ (19)
Ac 1 R2 R1
~
2m c p Uc
Figure 9. Figure displayed in “Shows equation”
846
Figure 8. Graphical interface of the computer code for the PV/T solar collector in transient conditions
5. VALIDATION OF MODELS By the resolution of the circuit shown in Figure 1, the local
values of the plate temperature Tp, of the fluid temperature Tf
To verify the correctness of the results provided by the and of the specific useful power qu, along the motion
models, initially a solar thermal collector, whose direction, are obtained; their trend is shown in Figure 11. The
characteristics are summarized in Table 1, is used. In the average value of the specific useful power obtained is of 568
same table, also the data of solar radiation on the collector W/m2. By the resolution of the circuit shown in Figure 2
plane, external air temperature and temperature of the (stationary conditions and average magnitudes), instead, a
incoming fluid to the collector are reported. value of the specific useful power of 568.8 W/m2 is obtained.
The same value, as shown in Figure 12, is reached
847
asymptotically with the resolution of the electric circuit in
transient conditions (Figure 3), when the transient condition
is exhausted.
Figure 11. Fluid temperature, plate temperature and The small difference between the two solutions is
specific useful power trend attributable to the evaluation of a single value of the global
heat exchange coefficient Uc, non-provided by the
manufacturer. It is derived from coefficients a1 and a2.
For the analysis of the models relative to the PV/T
collector, a collector with the characteristics reported in
Table 3 is used. Figure 14 shows the thermal efficiency of
the PV/T collector compared to the thermal efficiency of a
solar thermal collector, while Figure 15 shows the electrical
efficiency of the PV/T collector compared to the electrical
efficiency of the photovoltaic panel.
848
Figure 14. Thermal efficiency of a solar thermal collector
and thermal efficiency of a PV/T collector
849
Figure 18. Thermal and electrical power estimated with the stationary circuit model, for a PV/T solar collector
Figure 19. Thermal and electrical power estimated with the transient circuit model, for a PV/T solar collector
From the results presented in Figure 20, it is observed that, stationary conditions. On the contrary, in the afternoon hours,
under transient conditions, for the capacitive effects of the during which the collector cools down, the specific useful
collector, in the early hours of the day during which the power transferred to the heat transfer fluid is greater than that
collector is heated, the specific useful power transferred to obtained in stationary conditions (the collector takes more
the heat transfer fluid is less than that obtained under time to cool down).
850
Figure 20. Thermal and electrical power trend, stationary and transient circuit model, PV/T collector
6. CONCLUSIONS
REFERENCES
In this paper a simple predictive model to estimate PV/T
collector performance has been presented. The model is [1] Cannistraro A., Cannistraro G., Cannistraro M.,
based on an equivalent electrical circuit of the collector, Galvagno A. (2016). Analysis of the air pollution in
whose solution allows the evaluation of thermal and the urban center of four Sicilian cities, International
electrical power produced. The electrical circuit is modified Journal of Heat and Technology, Vol. 34, Special
according to whether the problem is solved in stationary or Issue 2, pp. S219-S225. DOI: 10.18280/ijht.34S205
transient conditions. As regards the stationary approach, two [2] Cannistraro A., Cannistraro G., Cannistraro M.,
different circuits were schematized: the first allowed Galvagno A., Trovato G. (2016). Technical and
evaluation of the quantities at different points along the economic evaluations about the integration of
motion direction of the fluid; the resolution of the second CoTrigeneration systems in the dairy industry,
electric circuit allowed direct evaluation of the average International Journal of Heat and Technology, Vol.
magnitudes between the inlet and outlet collector section. 34, Special Issue 2, pp. S332-S336. DOI:
With the transient model, instead, it was possible to estimate 10.18280/ijht.34S220
the behaviour of the collector by adding a capacitor of [3] Cucumo M., Cucumo D., De Rosa A., Ferraro V.,
capacitance equal to those of the thermal collector to the Kaliakatsos D., Marinelli V. (2009). Analisi teorica di
previous circuit. Obviously, when the transient condition is un collettore solare cogenerativo PV/T a liquido, 64°
exhausted, the various determined quantities are identical to Congresso Nazionale ATI, L’Aquila, Italia.
those measured in stationary conditions. Finally, the study [4] Cucumo M., Ferraro V., Kaliakatsos D., Mele M.,
showed that the electrical circuit used for this type of Cucumo D. (2017). Predictive methods to estimate the
collector is similar to that of the solar thermal collector, with producibility of PV/T solar collectors, International
the difference that some circuit components also contain Journal of Heat and Technology, Vol. 35, Special
electrical quantities. Issue 1, pp. S71-S77. DOI: 10.18280/ijht.35Sp0110
Electrical circuit resolution was obtained through the [5] Sproul A.B., Bilbao J.I., Bambrook S.M. (2012). A
MatLab software, schematizing the circuit in Simulink novel thermal circuit analysis of solar thermal
(software integrated with MatLab). collectors, 50th Annual Conference, Australian Solar
Simulating the behaviour of a thermal solar collector and a Energy Society (Australian Solar Council),
cogenerative PV/T solar collector, it was verified that the Melbourne, Australia.
three circuit models, stationary with local magnitudes, [6] Evans D.L. (1981). Simplified method for predicting
stationary with average magnitudes and transient (when photovoltaic array output, Solar Energy, Vol. 27, pp.
transient is exhausted), provide the same results. 555-560. DOI: 10.1016/0038-092X(81)90051-7
Comparing, instead, the PV/T collector behaviour in [7] Florschuetz L.W. (1979). Extension of the Hottel–
stationary and transient conditions, for a whole day, it was Whillier model to the analysis of combined
observed that, for the capacitive effects of the collector, photovoltaic/thermal flat plate collectors, Solar
during the morning hours in which the collector heats, the Energy, Vol. 22, pp. 361-366. DOI: 10.1016/0038-
transient model provides useful power values lower than the 092X(79)90190-7
stationary model and the opposite in the afternoon hours,
during which the collector cools.
851
NOMENCLATURE ~ global heat exchange coefficient between plate
Uc
and external air for a PV/T collector, W. m-2.
Ac absorbing surface area, m2 K-1
Cf hourly specific thermal capacity of the fluid, W. Up internal energy, J
m-1. K-1 W collector width, m
Cp plate specific thermal capacity, J. m-2. K-1 x motion direction of the fluid, m
cp specific heat of the fluid, J. kg-1. K-1
F’ collector efficiency factor Greek symbols
~ PV/T collector efficiency factor
F'
~ β temperature coefficient for cell efficiency, °C-1
FR PV/T collector removal factor
intensity coefficient for cell efficiency
Gc global radiation on the collector plane, W. m-2 ε percentage error, %
L collector length, m η efficiency
m mass flow rate of the fluid, kg. s-1 ηa electrical efficiency with Tc=Ta condition
Q power, W (τα) effective product between the cover
~ PV/T power, W transmission coefficient and the plate absorption
Q
q specific power, W. m-2 coefficient
q average specific power, W. m-2
Subscripts
Re thermal resistance between plate and external
air for thermal collector, m2. K. W-1 a external air
~ thermal resistance between plate and external
Re c cell
air for PV/T collector, m2. K. W-1 e electric
Rf thermal resistance between plate and fluid for es electric steady
thermal collector, m2. K. W-1 et electric transient
~ thermal resistance between plate and fluid for
Rf f fluid
PV/T collector, m2. K. W-1 in inlet section
S solar irradiance absorbed by the thermal out outlet section
collector plate W. m-2 p plate (collector)
~ solar irradiance absorbed by the PV/T collector
S R reference conditions
plate W. m-2 u thermal
T temperature, °C uCalc thermal calculated
T average temperature, °C uReal thermal real
Uc global heat exchange coefficient between plate us thermal steady
and external air for a thermal collector, W. m-2. ut thermal transient
K-1