You are on page 1of 2

PROJECT : PROPOSED 20ML CONCRETE RESERVOIR PAEC / INTEGRATED INNOVATORS, CO.

LOCATION : AFP ROAD, QUEZON CITY DESIGNED BY: MTE CHECKED BY: AMV/ROS
SUBJECT : SIZING OF DOWNSPOUTS DATE: 04 April 2011 DATE: 05 April 2011

Data:
Projected Projected Total No. Total Size of Roof Drains
Roof Designation Roof Area Roof Area Projected of Tributary Vertical Leaders Table A
(See Sketch) (Horizontal) (50% Vertical) Roof Area DS Area per Drain Size
sq.m. sq.ft. sq.m. sq.ft. sq.ft. Downspout in mm

Roof Area 2,740.50 29,501.38 0 - 29,501.38 10 2,950.14 5.0 127


say 150mm dia.

Total Roof Area = 2,740.50 sq.m. REMARKS:


29,501.38 sq.ft.
Say 29,500 sq.ft. Adopt 10pcs downspout with 150mm diameter =
10 x 5,400 sq.ft. = 54,000 sq.ft. > 29,501.38 sq.ft.

Therefore: SAFE !

i = 10 in./hr
or 250mm/hr (TOR)

DS dia. = 6 in
or 150mm