You are on page 1of 18

Ener

gof
low AG

Aboutt
hec
ompany
Ener
gofl
ow AGi
sanI SO 9001cert
if
iedSwisscompanydedi
catedtodesi
gn,engi
neer
ingandmanuf
act
ureof
fl
ow met
eri
ngsol
uti
onsandr el
atedproduc
tsbasedontheult
rasoni
ctec
hnology
.

AI
M
Westri
vetoprovi
dest
ate-
of-t
he-ar
t,c
ostef
fecti
vet
urnk
eyt ec
hni
cals
oluti
onst
oourv
aluedc
li
entsthr
oughout
theworl
df orfl
uidmeasurementandmoni t
ori
ng i
nr el
atedfi
el
dsac r
ossawiderangeofindust
ri
esand
appl
i
cati
ons.

Ex
per
ienc
e,Ex
per
ti
se&Ef
fi
ci
enc
y!
Ourc ompactt
eam ofEXPERIENCEDprof
essi
onalswit
hav as
tglobalex
pos
ureisdedic
atedt
oprovi
dethebest
answert ocli
ent
'srequi
rementsbased on ourEXPERTI
SE,and ourbusines
spr ac
tic
esand management
conceptsar
eaimedt oprov
idethehi
ghestdegreeofEFFI
CIENCY.

EnergoflowAGc anprovidetheopti
mal s
ol ut
iontoally
ourflowmet eri
ngrequirements–thewiderangeofour
productscoversal
lthef eas
iblefl
uidfl
ow s i
tuati
ons
.Andi fyouhav eanunus ual,outofthewayc ase–just
contactuswiththedetail
s!Wel ov
ec hal
lengesandourt eam ofEngineer
swillbejusttoohappytoprov
idethe
exactflow metercor
respondingtoyourr equir
ements.

1
Ul
tr
asoni
cLi
qui
dFl
ow met
ers

Ul
tr
asoni
cli
qui
dfl
ow met
ersENERGOFL
OW L
F
TheEner goflowL Fseriesofliqui
df l
owmet ersisdes i
gnedt oper f
ec ti
onforrel
iableandac c
uratemeasurement
ofliqui
df low i nfil
l
ed pi pel
inesus i
ng the puls
e- t
ime met hod.Thes ef l
ow met ers c an be used f
orf l
ow
moni t
ori
ngandmeas urementofpot abl
e,technicalorr i
v erwat er,oilandpet r
oleum pr oducts,heat
-tr
ansfer
agent,soluti
onsofal kali
sandac ids,war medfuel oi
l,heav yoi l
,s tablegascondens ateandl i
quif
iedpetr
oleum
gas,effl
uents ,etc
.atpr essuresupto250bar .As pecialver s
ionc apabl eofworkingatf lui
dpressuresupto400
barisavailableforapplicati
onslikemeas ur
ementofs tratalwat erf r
om oilwel
ls.Thef low metersoftheseries
aremanuf acturedinv ariousv er
sionsforappli
cati
onov erav astrangeofpr ocessc onditi
ons:

●forpipelinesfr
om DN25upt oDN7000
●forfl
ow s peedsasl ow as0. 1m/ sandashi ghas10m/ s
●forambi enttemper aturesaslow as- 65deg.Candashi ghas+70deg.Candat100% humi di
ty
●forl
iquidt emperaturesi ntherangeof- 20deg.Cupto150deg.C
●inhaz ardousareasandhar dtoac cessloc
ations
●forcl
amp- oninst
allat
ion,thepr ocesspress
ur ei
snotaconsi
derati
on,i
nli
never
sionsar
eavai
l
ableforl
i
qui
d
pressuresashi ghas400bar
●forfl
uidswi thac onsiderableamountofs uspendedsol
i
dpar t
icl
esandbubbl
es(upto5% byvol
ume)

Themaj
oradv
ant
agesoft
heEner
gof
low L
Fser
iesl
i
qui
dfl
ow met
ersar
e:

1.Noobs t
ruc t
iontothefl
ow andz er
opr essurel
oss
2.Nomov ingpar tsandnomec hanic
alwearort ear
3.Easyinstal
lati
onands i
mplici
tyofuse
4.Easyint
egr ati
onintoal
lkindsofproc
es smanagementsystems
5.Highaccuracy,l
argetur
n-downrati
o,reli
ablemeas
urementandfas
treac
ti
ont
ochangesi
npr
oces
scondi
ti
ons

2
Ul
tr
asoni
cLi
qui
dFl
ow met
ers

Thefl
owme t
ersoft
heser
iesa
remanuf
act
ure
dinvar
i
ousve
r s
ions–
i
n-l
inese
cti
ons,e
mbe dde
ds e
nsor
sins
tal
l
ati
onandcl
amp-ont y
pe.

ENERGOFLOW LFwi thclamp-onsensor s,embeddedsensor sandi n-li


nesect ionsar edesi
gnedfor
useinf i
el
dc ondit
ionsformonit
ori
ngandmeas urementoffl
ow ofl
i
quidseg.potable,t
ec hni
calorri
verwat
er,
heat-
transf
eragent ,sol
uti
onsofalkal
i
sandac ids
,oilandpet
rol
eum produc
ts,heatedfueloil
,tar
,energyoil
,
coke-c
hemi c
alr aw materi
al
,stabl
egasc ondensateandli
quefi
edgas,effl
uents,andal soli
quid ammonia,
sal
tpeter
,etc.

Flow met
ersar
edesi
gned forsi
ngl
echannelandtwo-c
hannel
s(fourchannel
sunders
pec
ialor
der
).Eac
h
channelc
anbeusedi
ndependent
lyt
oaccountf
orl
iqui
dindi
ffer
entpipel
i
nes.

Wit
heachchanneloffl
owmet ertwos
ens
orsar
eus
ed.Sens
orsar
epl
acedi
nas
trai
ghtpar
tofpi
pel
i
ne,whi
ch
i
sprot
ect
edfrom prec
ipi
tat
ions.

Clamp-onsensors(theyar
emountedonthes
urf
aceofthepipe),embeddedsensor
s(whi
chareinser
ted
i
ntoapert
ures,madeinthepipewal
l
)canbeusedforl
argerpipediamet
ers(
upt
opipeDN4m,largersi
zes
unders
pecialor
der
).

TECHNI
CALCHARACTERI
STI CS
Parameter Clamp-onsensors Embeddeds ens
ors
Innerdiameterofthepipel
i
ne,mm 70…3200 25…4000
Accurac
yoff l
ow meas ur
ement ,% ± 1,0;± 1,5 ±0,5;± 1
Rangeoff l
ow veloc
itymeasurement,m/s 0,1-10 0,1-10
Rangeofoper at
ingtemperaturesfort
hesens
ors
,°C -20...
120(250) -20...
150(
250)
Rangeofoperat
ingtemper
atur
esf
ortheel
ect
roni
cuni
t,
°C -20..
.60(75) -20..
.60(75)
Rangeofoperat
ingtemper
atur
esf
orPSU,°
C 5..
.40(75) 5..
.40(75)
Suppl
yvolt
age,V »220;
10±24 »220;10±24
Requi
redpowerisnotmore,W 10 10

Powersuppl
yandc onnect
ionunit(PSU)isequippedwi
ththeint
erf
ace RS-232/RS-
485forc
onnecti
onwi t
h
computer
.Fl
owmeterformspulse-f
requencysi
gnalands
ignal
ofdir
ectc
urrent0..
.5or4.
..
20mA,proport
ional
tovol
umetri
cfl
ow r
ate.

3
Ul
tr
asoni
cLi
qui
dFl
ow met
ers

I
n-linesec
t i
onsar
eint
endedf
orme di
um ga
ugepr
ess
ureupto1,
6MPa,wit
hli
qui
dtempe
rat
uref
rom 0.
..150de
g.C,
f
orinnerpi
peli
nedi
ameter(
DN)from 200…1600mm andcanbeins
tal
l
edinplaces
,ex
posedt
oc l
imatic
i
nfl
uences(dampbasement
s,wel
l
s )
.

Theflow met
ersareal
soavai
l
abl
ewit
habuil
tinbat
ter
yonboar
dfori
nst
all
ati
onats
iteswher
epoweri
snot
avai
l
able.Theli
fet
imeoft
hebatt
eryi
smor
ethanoney ear
.

TECHNI
CALCHARACTERISTICS
Vol
umef
l
ow Nomi
naldi
amete
rofPi
pl
el
ine,mm
rat
em3/
h 32 40 50 80 100 150 200 250 300
Qmax 30 45 75 180 285 640 1130 1770 2550
Qt 2,
0 2,
5 3,
0 5,
0 6,
0 9,
0 12 15,
0 18,
0
Qmin 0,
20 0,
35 0,
5 1,
3 2,
0 4,
0 8,
0 12,
4 17,
8
Qthreshold 0,
015 0,
025 0,
035 0,
1 0,
15 0,
35 0,
6 0,
9 1,
3

ADVANTAGES:
● Simplici
tyandr eliabili
tyint heoper ati
on;
● Wi derangeoft hemeas urement sofv olumet ri
cfl
ow r ate(1: 150) ;
● Thec r
eatedar c
hi vesc ontainedhour lydat aforpas t1024hour s( morethan42day s
);
● Adj ust
mentoff low met erint hec ompl etes etwi t
hi n-li
nes ec t
ioni scarr
iedoutonmanuf acturer;
● Ther eisnoc ontrac t
ioninsidet hei n-l
ines ection;thereforeflow met erdoesnotcreatetheresi
stancetothe
f
low ofl i
quidanddoesnoti nt roduc edi sturbanc esintothef low;
● Aut omaticadjusti
ngoft hes ignall evel;
● Flow met erisequi ppedwi thpul s
e- fr
equenc yout put,anal ogout put(onorder),andinter
faceRS232;
● Flow met erwitht heaut onomouspowers uppl ywor ksupt o4y earswithoutthereplac
ementofbat t
ery
;
● Flow met ercanbeeas il
yint egr atedi ntoaut omat edSCADAs y
s t
emsandex is
tingcontr
olsystems ;
●I ntervalbetweenv erif
icati
on-2y ear s.

4
Ul
tr
asoni
cLi
qui
dFl
ow met
ers

L
iqui
dFl
ow met
erL
F131Hf
orhi
ghpr
ess
ureappl
i
cat
ions

Forapplicati
onswherethemedi um press
urei sver
yhigh,eg.meas ur
ingt hefl
ow ofst
rat
alwater,wehave
developedthemodelL F131H.Thedev ic
ec anbeus edforbidi
rect
ionalmeas urementoffl
ow ofmediumsat
pressureashi ghas40Mpa.Thes ef l
ow met ersar
eavail
ableintwov ersi
ons -withanintegr
all
ymounted
Elec
tronic
suni thav
ingabuil
t-i
nbatter
ywhi c
hpr ovi
desf
ullautonomousf uncti
onal
it
yformorethanfoury
ears
,
orwithas t
andardremot
elyinst
all
edElectr
onicsunit
.

TheL F131H f
low meter
sarewidelyusedinthedownstr
eam appli
cati
onsintheOi l& Gasindust
ry,eg.at
extr
acti
onwell
ssinc
etheyareruggedandc anhandl
eaggres
siv
eliqui
dsats uc
hhighpr ess
ure.Theyarealso
usedforappl
i
cati
onsli
kecementi
ngofwellsandmeasur
ementofflow ofchemical
sinjec
tedint
owellsathigh
press
ure.
TECHNI
CALCHARACTERI
STI
CS
P
ara
met
ers Nomina
linne
rdiametero
fthepi
pel
i
ne,DN,mm
50 80 100
Li
quidt
emper ayure,
ºC 0..
.150ºC
Gaugepres
s ure,MPa 16MPa,25MPa
Maxi
mum flow Qmax,m3/
h 71 180 285
Tr
ans i
ti
onalfl
ow Qt,m3/ h 4,
2 6,8 8,5
Minimum fl
ow Qmin,m3/ h 0,
7 1,8 2,8
Threshol
dflow QThreshold,m3/
h 0,
15 0,
35 0,
35
Rel
ati
veer
rorofmeas
urementoff
low andv
olume,%
Qt… Qmax ± 1%
Qmin … Qt ± 4%
Qthreshold… Qmin cal
cul
ati
oni
sconduc
tedwi
thnonstandar
diz
edaccuracy
F
ort
hef
lowsl
essQthreshold v
olumeisnotac
cumulat
ed(
Flow i
stakenasequaltozero)

5
Ul
tr
asoni
cLi
qui
dFl
ow met
ers

Por
tabl
eUl
tr
asoni
cLi
qui
dFl
ow met
erEner
gof
low L
F2P2

Theport
abl
ef l
ow met
erENERGOFLOW L F2P2withcl
amp-onsensorsi
sdesignedforus
ei nfiel
dcondit
ions
formoni
tor
ingandmeasurementoff
low ofli
qui
dseg.water
,petr
oleum andpetrol
eum product
s,indus
trial
chemi
cal
s,sol
vent
s,et
c.i
nf ul
l
yfi
ll
edpipel
ines
.Thesetcomesi
nahandy ,easytocarr
ydurablecaseandc an
beusedfor
:

●s
ingl
echa
nnel(accur
acy1.5%)a
ndtwi
nc ha
nnel
(accur
a c
y0.5%...
.1% )f
lowmeasur
ementsonasi
ngl
epipel
i
ne
●r
eal-
ti
mec ompar
isonorsummati
onoff
lowsintwoadjacentpi
pel
ines(s
ingl
echannelmodeperpi
pel
ine)

Thi
ss etisaboonf orrepai
rteamsandf i
el
dengineers
.Thebui l
t-
indigi
talosci
l
lographf ac
il
it
yandi nl
i
ne
cal
i
brati
onfunct
ionmakeinst
all
ati
onandc ommiss
ioni
ngv eryfast
,simpleandeasy.
Thefl
owme te
rcanal
sobeuseda saful
l
fl
edgedst
anda l
onel
iquidfl
owme te
rforin-
si
tuins
tall
at
ionsinremot
eplace
s.

Thec
ompl
etes
etc
ompr
isesoft
hef
oll
owi
ng:

1 LF2P2 –El
ectr
onicuni
t(twi
nchannel
)wi
thL
CDdi
spl
ayandk
eyboar
d 1 pc
.
2 El
ect
roac
oust
ictr
ansducer 4 pc
s.
3 Remov ableplates(forclamp-onins
tal
l
ati
on) 16pcs.
4 Poweruni t/Bat t
eryc harger5V
,1А 1 pc
.
5 Thick
nes sgauge 1 pc
.
6 Water-resi
stantgrease 1 pc
.
7 Accumul at
orc harger 1 pc
.
8 Tappinghammerwi thscrewdri
ver 1pc
9 Measuringroul et
te 1pc
10 Standardsstr
ipf
orcal
ibrat
ionofthic
knessgauge 1pc
11 Connec t
ingcabl
esf
ortransduc
er swit
hc onnec
tor
s,2x10m 2set
s
12 Carryi
ngc as
e 1pc
13 Accessori
esfori
nst
all
ati
ononpi pes(chai
nsandclamps
) 1set

Manufac
turer
'swar
rantycer
ti
fi
cat
e,inst
ruct
ion manual and s
oft
ware CD wit
hc abl
e(f
orc
onnec
ting t
he
el
ect
ronicuni
ttoPCfordat
atrans
ferandconfi
gurat
ion)ar
eprovi
dedwit
heac hset
.
TECHNI
CALCHARACTERI
STI
CS
Par
ameter Value
Pi
peinnerdi
amet er
,mm 70-3200
Accur
acyoffl
ow meas ur
ement ,% ±1,0%,±1,5%
Rangeoffl
ow veloc
itymeasurement,m/s 0,1-10
Rangeofoperat
ingtemperaturesfort
hesens
ors
,°C -20…+120
Rangeofoperat
ingtemper
atur
esfortheel
ect
roni
cunit
,°C +5…+45
Rel
ati
veerr
orofmeas ur
ementofexpendi
tur
eandv ol
ume,mm ±0,2
Suppl
yvolt
age,V 220or6,
5
Requi
redpowerisnotmore,W 10

6
Ul
tr
asoni
cLi
qui
dFl
ow met
ers

Doppl
erf
low met
ersf
orl
i
qui
d
Ult
rasoni
cFlow metersLDFaredes
ignedformeas uringflow vel
oci
ty,vol
umetr
icflow r
ateandl i
quidvolume,
tr
ansport
edt hr
oughpipeli
nesi
ntheforwardorrev ersedirec
tionusingtheDopplereff
ect.Theyc anbeus ed
f
ormeas uri
ngac ous
tic
all
yopaquef
lui
ds–s l
urr
ies,liquidswithsuspendedpart
icl
esandot hercontaminati
on.
.

Thefl
owmeterc ompr
isesoftwocl
amp-onelec
troacoust
ictr
ansducer
sandaremot
elyi
nstal
ledelec
troni
csuni
t
andcanbeus edtomeas ur
ebidi
rect
onalf
low offl
uidscontai
ningnotl
esst
han0.1% ofsuspendedparti
cl
es
orgasbubbl
es.

Thes
ef l
owmeterscan beinst
all
edonpipeshav
ingwal lt
hic
knes
sof2t
o20mm madeofv
ari
ousac
ous
tic
all
y
tr
anspar
entmater
ial
s:steel
,casti
ron,c
ement.plas
tic et
c.

TECHNI
CALCHARACTERI
STI
CS
Parameter Value
Innerdiamet
erofthepipel
ine,mm 40-1600
Rangeofv el
oci
tymeasurement ,m/s 0,1-6
Accurac
yofthemeas ur
ement ,% 2
Rangeofoperati
ngtemperaturesforthes
ens
ors
,ºC -20..
.+100
Supplyvol
tage,V 220or12
Consumedpower,W 12
Dis
tancebetweensens
orsandel
ect
roni
cuni
t,m,notmor
e 70

Themaj oradvantagesoftheUlt
ras
oni cFl
ow metersLDFare:
● Easyinstal
l
ationands i
mpli
ci
tyofus e;
● Appli
cableformeas ur
ementsinpipeli
nesevenifthepi
pewall
saregr
eat
lyc
orr
odedorhav
eat
hic
klay
erof
sedi
ment ;
● Easyintegr
ationintoal
lki
ndsofpr ocessmanagementsyst
ems;
● Reli
ableandac curat
emeasurement .

7
Ul
tr
asoni
cLi
qui
dFl
ow met
ers

Hi
ghac
cur
acy5c
hannelL
iqui
dfl
owmet
erL
F505

Forappl
ic
ationsrequi
ri
ngveryhi
ghaccurac
y ,wecanoff
ertheL F505liqui
dflowmet er
.Thedevi
cec
anbeused
f
orreli
abl
eandac cur
atemeasur
ementofs peedofthefl
uid,f
low rat
eandt otalfl
ow infi
l
ledpi
pel
i
neshav
ing
anominalinnerdiameteri
ntherangeof100upto300mm andatpr essur
eupt o6,3MPa.

Thedev
icei
sequi
ppedwi
thanRS232i
nter
fac
efordat
aout
putaswel
laspul
seout
put
.

The f
low met
ers are pr
ecal
i
brat
ed on water
.Unders peci
alor
der
,they c
an be pr
ecal
i
brat
ed on l
i
qui
d
hydr
ocar
bonsorothermediaaspert
hec l
ient’
srequi
rement
.

TECHNI
CALCHARACTERI
STICS:
Par
amet
er I
nnerdi
amet
erofPi
pel
i
ne,mm
100 150 200 250 300
Ac
c ur
acyoff
low measurement
,%,notl
esst
han
+/-0.15% f
orfl
ow range 280-140 600-300 1200-
600 1800-
900 2500-1250
+/-0.25% f
orfl
ow range 280-28 600-60 1200-
120 1800-
180 250-250
Repeati
bil
it
y,% 0,04
Medium temperat
ure,deg.C -
30...+150
Medium press
ure,MPa 1,6
Supplyvolt
age,V 220
Dis
tancebetweenelectr
onic
sunitand 150
Inl
i
nes ecti
on,m,notmorethan

8
Ul
tr
asoni
cLi
qui
dFl
ow met
ers

L
iqui
dfl
ow met
ers
elec
tiongui
de
No.ofmeasur
ementchannel
s
x–numberofc hannel sofmeas urement
0-Fl
angeds ectionwi t
hElec t
roAcoust
icTransduc er s
1–Clamp- ons tationary ElectroAcous
ticT
r ansduc ers
2–hot-tappedi ns tal
lati
onofEl ect
roAcousti
cT rans ducer
sinpi
pel
i
newal
l
3–Customers pec ifi
cappli
c ati
ons
P–portablev ersion
x–numberofEATpai rs
Appl
icat
ion
A–s t
andardappli
cat
ions
H –Highpress
ureappli
cat
ions
O –Customerspeci
fi
cappli
cat
ions
Ambi
entt
emper
atur
e
L-Low temperaturevers
ion(-
60….+40deg.C)
S-Standardversion(-
30….+40deg.C)
H -Hi
ght emperaturever
sion(
-30….+70deg.C)
I
nst
all
ati
ondat
a
DNxxxx–Pi
penomi
naldi
amet
er,mm
Accur
acyofmeasur
ement
N –nor
mal(1,
5% f orQttoQmax ,3% f
orQmi
ntoQt
)
S–Standar
d(1% forQtt oQmax ,2% f
orQmi
ntoQt
)
C–highaccur
acymeasurementsupto0.
5%
O –Cust
omerspec
ifi
cupto0.25%
Pr
oceesconnect
ion
N –nofl
anges,hot-
tappeds
ens
ors
D –Fl
angesDIN
xxx–PN,bar
A–FlangesANSI
xxxx–c l
as s
C–c l
amp-onsensors
O –Cust
omers peci
fi
c
El
ect
roni
csbl
ock
I–integr
all
ymountedelec
tronicsblockwit
hdispl
ay
R –Remotemountedelect
ronicsblock
W –Elect
ronicj
unc
tionboxwi t
houtl oc
aldi
spl
ay
Hazar
dousar
eacer
tif
icat
ion
I–Exicer
ti
fi
cat
ion( ATEX)
W –wit
houtcer
tif
icati
on(fornonhaz
ardousappl
i
cat
ions
)
Powersuppl
y
A–220VACpowers uppl
ysy s
tem wi
thintr
insi
cbarri
ersandc ommunic at
ioninter
fac
e
D –24VDCpowers upplysy
s t
em wit
hintri
nsicbar
ri
ersandc ommuni cati
oninterf
ace
O –Cus
tomerspec
ifi
c
W –wit
houtpowers uppl
y,cust
omertoprov i
derequi
redpoweri nput
B–Powersupplyf
rom onboar dbatt
ery(batt
erytober epl
acedev er
y3y ear
s)
Accessor
ies(
opt
ional
)
F–Meetingflangeswithnutsandstudstobesuppli
edwi
thf
low met
er
R –s
trai
ghtpipe-runstobesuppli
edwithfl
ow meter
C–Flow condit
ionertobesuppli
edwithfl
ow meter
N-Noadditi
onalac ces
sor
ies

9
Cal
i
brat
ionandpr
ovi
ngr
igs

Cal
i
brat
ionandpr
ovi
ngr
igsf
orl
i
qui
dfl
ow met
ers

Thepr incipl
eoft hefuncti
oningoft her i
gisasf ol
lows :
Bys witchingononeormor efansaf l
ow ofthemedi um i sgener at
edi nthepipingoft heri
g.Thef l
owrat eand
pressureoft hemedi um isregulatedbyc ontrol
l
ingt hepump,t he fanandadi aphragm v alve.Thef l
ow t hus
generatedi smeas uredbyt her ef
erencef l
ow met eraswel last hef l
ow met erbei ngv erif
iedorc al
ibrated.
Reference pr es
sure and temper aturetransmit
tersar e used f ordet er
mi ni
ng t he wor ki
ng conditi
ons .The
accumul atedpulsequant i
tyov eranumberofc y c
lesi srecor dedandt hetotalmeas ur edvolumeats tandar d
temper atureandpr ess
ureisc alc
ulatedforboththef l
owmet ers.Thec ompar i
sonoft her esul
tsgivesar eli
able
meas urementoft heac c
urac yoft hemet erunderv eri
fi
cation.Di ffer
entr ef
erenc eflow met ersareus edf or
dif
ferentr angesofmeas urementwhi chalsoimproves t heac curacyandr eli
abil
ityoft heresult
s.

FORL
IQUI
DFL
OW METERS:

Desi
gnedforautomatedtesti
ng,gradi
ngandc ali
brat
ionofmet
ers
,fl
ow met
ersandmas
smet
ersofl
i
qui
d
usi
ngtwomeas urementmethods:
● methodofcomparis
onwi t
hs t
andardfl
ow meter(mode1);
● methodofstat
icweighi
ng(mode2) .

Inmode1c ounter
sandflow meterswithrel
ati
veacc
uracyofvol
umetri
cfl
owrat
eandvol
umemeasurement
±0,3% andmorearet
estedorc al
ibr
ated.
Inmode2t hefl
ow metersi
ncludi
ngmas smeterswi
threl
ati
veaccur
acy±0,05% andmorear
etest
edand
cal
i
brat
ed.

10
Addi
ti
onal

UL
TRASONI
CNON-
INTRUSI
VEPI
GDETECTORUL
IS-
A

ULIS-
Ai sanon- i
ntr
usiv
eultrasoni
cpi gpassagei ndi
cat
ordesignedforr
eli
abl
edetect
ionofallki
ndsofpigs
usedforpiggingoff
il
ledli
qui
dpi pel
ines.Itals
opr ovi
desindi
cati
onandanes t
imateofacc
umulateddebr
isin
fr
ontoft hepi gandanes ti
mat eoft heeffect
ivenessofthepi ggi
ngproc
edure.Thedevic
ei scer
ti
fi
edas
i
ntri
nsi
call
ys afef
oruseinhaz ar
dousar eas.

Thepi gdetectorcompr i
sesofanul t
rasonicnon-intr
usivesensorc lamped tot heoutsi
deofthepi peanda
remotelyi
nstall
edelec t
roni
csunit
.Thec lamp-ondes i
gnofthes ens orall
owst hedevi
cetobeus edforallpi
pe
siz
es.Theel ectroni
csuni tprovi
desv i
sualindic
ation ofpig passageaswel ladr yrel
ayoutputs ignalfor
i
ntegrati
onintoex is
tingcontr
olsyst
ems .Besides,theelect
ronicsuni tpr
ovidesarchi
vi
ngofupt o120ev ents
ofpig detect
ion and automaticres
etf uncti
ons.Wi ththehel p ofs peci
al
ized sof
twareprovi
ded,gr aphi
cal
vis
uali
zati
onoft heappr oachofthedebr isplugaswel laspig/spher epassageandc hangeindensityofthe
fl
uidi
spos si
ble.

Themaj oradvantagesoft heULIS-Apigdetectorare:


● Thenon- i
ntr
us i
vedes i
gnprovideszeropressuredr opandnoobs t
ruc
tiont othef
low ort
hepigandal
lows
foral
lk i
ndsofapplicati
ons-highpressure,sours ervi
ceetc ;
● Anyty peofpig,sphereetc.canbedet ectedinbot hdirec
tions;
● Therearenomec hanicalmovingparts-sonowearort ear,mini
mum s ervi
ci
ng;
● Theac ti
venatureoft heult
rasoni
cdev i
ceguar anteesreli
ablepigdet
ec ti
onelimi
nat
ingfal
seal
armsdueto
outsi
deinterf
erence.

11
Addi
ti
onal

Detect
ors ar
e cer
tif
ied f
oruse i
n hazar
dous ar
ea and have EC-
Type Exami
nat
ion cer
tif
icat
e
numberFTZU 11ATEX0144X.

EASYI
NSTAL
LATI
ON

1.Trans ducersoft hedet ectors houldbei nstall


edont hepipeli
nesfordetectionoft hel arge-si
zeobject
s
(i
nc l
udi ngpigs,s epar ati
ngbal l
s,gauges ,diagnos t
icsdevicesetc.
),propell
edbyt hel i
quidf l
ow inthe
pipelinesundert hepr essure,fordet ermi nati
onoft hemomentwhent heobj ectisc r
os si
ngt hepipel
i
ne
sectionunderc ont rol.Ac orrespondingwar ni
ngs i
gnali
ss entt othedat ac oll
ecti
ons yst
em ortot he
Adv anc edCommuni cat i
onsSy st
em (ACS) .
2.Detec toralsopr ovidest hedet ecti
onoft hes o-call
ed«par aff
inplugs»(referredaspl ugs )intheoil
pipelines.
3.Detec torisdes i
gnedf orthepi peli
neswi thpas sagediamet erDNf rom 150upt o500mm andf rom 350upto
1200mm,andwal lthicknes supt o60mm.
a. Det ect
orc ons i
st sofas ystem uni t(SU)andanel ect
roacousticact
ivet r
ans ducer( EAT),attachedtothe
pipeli
nes urfac ebyamount ingtool .EATi sc onnecti
ngt otheSUbya4- wirecable.
b. EATt ransmit sandr ec ei
vesanul trasonicsignal.
c. UL IS-ASUi si ntendedf orins t
all
ationi ndoorandout doorofex pl
osionhaz ardz ones .

Paramet
e r
so ftheindi
c a
tor Va
lue
Diamete
ro fthepipeli
ne,mm 15
0–1 200
Speedofmo v e
me nto fthedevi
ceofc
lea
ri
ngo
nthepi
pel
i
ne,k
m/h 1–8
Lengthofthede vi
ceo fcle
ari
ng,m 1–2
Envi
ronmentt empe r
ature -40…+6 0°C
Vol
tageofde vi
ce 22
0V ,5
0Hz
Powerco nsumpti
o n,Wt,nomor
e 6
1."Dryc ontac
t""Event" 30V
,2 0
0mÀ
2."Dryc ontac
t""Fuse" 30V
,2 0
0mÀ
3.Currento ut
put 4–2 0mÀ
4.Seri
alinterf
ace RS-
232/RS48
5
Dis
tancef ro
mt hega ugeupt
othee
lec
tro
nicbl
ock
,m,nomo
re 150
Cert
if
ica
t i
on Se
nso
r:I
I2 GExibII
BT4
El
ect
roni
csbl
ock:I
I(2
)G[
Exi
b]I
IB

EATisdesi
gnedi
nexplos
ionsafeenc
los
ureandc anbeinst
alledindoor
sandoutdoor
sinexpl
osi
onhaz
ard
zonesac
cor
dingt
orul
es,regul
ati
ngel
ect
ri
calequi
pmentappl
icati
onintheexpl
osi
onhazar
dzones.

12
Addi
ti
onal

Sk
idd
esi
gna
ndf
abr
i
cat
i
on
Keepi
nginli
newit
hourprinc
ipl
eof3E's–Experi
enc
e,Exper
ti
se&Effi
ci
ency
,Energofl
ow AGpr
ovi
desi
tsc
ust
omer
'swi
th
i
ndivi
dual
l
ydesi
gned,pr
efabri
cat
edandpret
est
edinst
rument
ati
ons
kidsforvar
iousappl
ic
ati
ons
.

At
ypi
cals
kids
uppl
ypr
ojec
tcompr
isesoft
hef
oll
owi
ngs
tages
:
Design–Ourt eam ofengineer
sprovi
descompleteski
ddesignserv
icesstar
ti
ngf r
om ac onceptualst
udyoft
hetechni
c al
assi
gnmentandt hroughfini
sheddr
awingsreadyforf
abri
cat
ion.Thedes i
gnprocessincl
udesdetail
edanal
ysi
sofel
ectr
ical,
i
nstrumentat
ion,programmingandfabri
cat
ionaspect
s.Incl
os ei
nter
ac t
ionwit
ht hec l
i
ent,wedev is
eopti
malsol
uti
onsfor
thecli
ent
'srequir
ement s.

Fabrication–Atourfaci
l
iti
es,ourtechni
ci
ansandengi neer
sprovi
def
abr
icat
ionofski
dsfrom awi
derangeofmater
ial
s
andinstr
umentsasperourowndes i
gnorasperdrawingsprovi
dedbyt
hecl
ient.Thes
tri
ctqual
it
ycont
rolpr
ocedur
esand
useoflatestt
echnol
ogi
esguaranteesthebestr
esult
s.

Calibr
ationandCont rol
s–Bef oreshippi
ng,ourengineersmak
es ur
ethatallt
heins
trument
sinc
ludedintheskidar
e
corr
ectl
yc al
i
brat
edandproperl
ywiredandt hecontr
olsystemsar
eadequatel
yprogr
ammed.Thec l
ientget
sa“ Pl
ugand
Play
”modul ewhichpr
ovi
desful
lfunct
ionali
tyandbestperfor
mance.

Testi
ng–Allski
ds ys
temsar evi
gor
ousl
yt es
tedatourf
aci
l
iti
est
oens
urepr
operoper
ati
oni
nthef
iel
dandc
onf
ormanc
e
tothehi
ghes
tint
ernati
onalqual
i
tyst
andards.

Commi ssi
oning–Ourteam oft
echni
ci
answi
ll
assi
styouwi
tht
hecommiss
ioningoft
hesuppl
i
edmodul
eatyourf
acil
i
tyunt
il
youar
ec ompl
etel
ysat
is
fi
edwiththeski
d'
soper
ati
on.Wecanal
soprov
ideextensi
vet
rai
ni
ngofcus
tomer
'sper
sonnel
.

Des
ign,Ins
tal
l
ati
onandc
ommi
ssi
oni
ngoff
low met
eri
ngand
monit
ori
ngsyst
ems
Energofl
ow AG c anprovi
deservi
cesf ortur
nk eyinstal
lat
ionoff low meteri
ngandf l
owmoni t
orings ys
temsf orvari
ous
appli
cati
ons.T aki
ngintoacc
ountthewi der angeoff l
ow met er
ings ol
uti
onsdevel
opedbyus ,wec anof ferthec l
i
ent
syst
emsi ncorporat
ingt
helat
estdevelopmentsintechnologiesanddatat r
ansf
erforvi
rtual
l
yalltypesoffluidsandpr oc
ess
condit
ions;bei tcommunalwaters uppl
ys yst
ems ,leakdet ecti
ons y
s t
emsf orpi
pel
ines,cust
odyt ransfers ol
uti
onsfor
hydrocarbons–y ounameitandwewi l
ldoit
.

Beginni
ngf r
om desi
gn,ourteam wor
ksinc l
osecoll
aborationwit
hthec
li
enttodev
elopatail
ormadesol
uti
onexac
tlyas
pert hecli
ent'
srequir
ementsandexecutesthewhol epr ojec
ttothecl
i
ent'
sutmostsat
isf
acti
on.Wecanals
oprov i
de
economical
lyopti
mizedsol
uti
onsformoderni
zati
on,developmentandext
ensi
onofalr
eadyexi
sti
ngsys
tems.

13
Addi
ti
onal

Hot
-tappingi
nst
all
ati
onandcommi
ssi
oni
ngoful
tr
asoni
cfl
ow
met
er sforpi
pel
i
nesupto6000mm di
ameter
Energof
low AG off
ersit
ss ervi
cesfordesi
gn,instal
lat
ionandcommissi
oni
ngoff
low meter
inguni
tsforl
i
qui
dsandgases
i
n-si
tu on exi
sti
ng press
ur i
zed pi
pel
ineswith diameter
saslargeas6000m.Themet hod i
nvol
vestheuseofspec
ifi
c
tec
hniquesandi ns
trumentsanddoesnotr equirestoppi
ngthefl
uidf
low.

Themet
hodisespec
ial
l
yeff
ect
iveforl
argediameterpi
pel
inesandinc
aseswher
efl
ow met
eri
ngi
srequi
redi
nanex
ist
ing
pi
pel
i
newhil
estoppi
ngthef
low ordr
aini
ngthepipeisnotfeas
ibl
e.

Themethodtakesi
ntoac c
ountt
heact
ualgeomet
ryofthepipel
ineatt
hei
nst
all
ati
ons
ite,pr
oces
scondi
ti
onsandot
her
l
ocalf
act
ors
,thusprovi
dinghi
ghl
yacc
urat
eandrel
iabl
eresul
ts.

Hot-
tapping devi
ceforins
tall
ati
on ofs
ens
orsi
n pi
pel
i
nes
underpressureEner
gof
low HSID-01
Toc reat emet eri
ngs tat
ionsonl argedi amet erpipelinesaswell
asforon- the-si
temoni t
or ing( eg.duringr epairs)offlowr at
ein
pipelinesi nf i
eldusings tandar dflow met ers,thes pec i
al
ist
sof
Ener goflow AG hav edev el opedt het echnology( met hodology
,
tools and gadget s) f or i nstall
ati
on of i ns erti
on-t
ype
electroac ousti
ct r
ansduc ers( EAT) i nto pipelinewal l
s,which
cant henbec onnectedtot hes tandardelec tr
onicsbl ockofthe
corres pondingEner gofl
ow GForL Fs eri
esf low met ers
,thus
creatingaf ullfl
edgedf l
ow met erin-si
tuwi thouts toppingthe
technol ogicalproces
s .

HSID-01 i
s used forhigh-preci
sion s
pacing ofinput/out
put
poi
ntsofacousti
cc hannel
sont hes ur
fac
eoft hepi pel
i
ne,for
dri
l
li
ngwor kwi t
houtdepr ess
urizati
onoft hepipel
ineandf or
hermeti
cinst
all
ati
onandr emov alofEATs.

Thedev i
cecan beused forinstal
l
at i
on ofs ensorsinr
ound
pi
pel
inesaswellasthosewithanex pressedell
ipti
ci
tywi
thout
st
oppingthef
low orempty
ingt hepipeline.

14
Addi
ti
onal

I
nte
gra
tedme
ter
i
nga
ndmo
nit
ori
ngs
yst
ems

Beingthesuppli
erofav as
tr angeoffl
uidmonit
ori
ngandmeasurementequi
pment,Ener
gofl
ow AGc anal s
o
designint
egrat
eds ys
temst ail
ormadeforyourrequi
rement
s.Thepurposeofsuc
ha s ys
tem istoc ol
lect
processdat
af r
om vari
ousremot el
yloc
atedsi
tesandprovi
deacces
stothecons
oli
dateddataforanaly
s i
sto
authori
zedusers
.

T
ypical
l
y,anint egrat
eds yst
em incl
udes:
●f i
el
dinstr
ument ationformeas ur
ingvar
iousprocessparametersatsit
e;
●f i
el
dPL Csfordat aaccumulati
onandmoni tori
ngoffiel
ddevicesatthesit
e;
●f i
el
dpowers upplyandbac kupunits
;
●s i
tedatatransmi s
sionunit
s;
● di
spatc
hers tati
onswi t
hSCADAs yst
em forcol
lect
ingdatafr
om v ar
ioussi
tesandc
oll
ati
ngi
tforus
erac
ces
s.

Suchs ys
temsar ei
ndi
spens
ibl
ef oroiland nat
uralgaspi
pel
ines
,ir
ri
gat
ion s
yst
ems,munici
palwaterand
was t
ewaternet
work
sandotherfaci
l
iti
eshavi
nganumberofs i
test
obemonitor
edspr
eadoverrel
ati
vel
ylar
ge
areas.

15
Addi
ti
onal

Gr
eenP
owe
rSo
lut
i
ons

Energofl
ow AG i
sdedi
cat
edt
ospr
eadt
hei
deaofc
reat
ingabet
terenv
ironmentbyus
ingec
ologi
cal
l
ycl
ean
sol
utions
.

Allourdevic
esc anbes uppli
edwi t
h"Gr eenPowerSol
uti
ons
"-sol
arener
gybas
edautonomouspowersuppl
y
unitscapableofprovidi
ngt hef ul
lfuncti
onal
i
tyoftheequi
pment
.Ourengi
neersc
anal s
oprovi
deforsuch
solut
ionsforequipments uppl
iedbyot hermanuf
act
urer
s.

Typi
cally,s uchas ol
uti
onwoul dcompr i
seoft hr
eemaj orparts:
1.As olarpaneloft herequi r
eds i
zeforc onverti
ngs ol
arenergyi ntother equier
edamountofel ect
ric
alpower.
2.Anac cumulatorbatt
eryf orstor
ingt hegener at
edpower .
3.Ani ntelli
gentcontr
oll
erf orsmoot hoperationoft hewholes y
s tem -f orregul
ati
ngthepowerout putandf
or
moni toringthestat
usoft hesolarpanel,theac cumulatorbatteryaswel lastheambientcondi
ti
ons.The
controllercanbeequi ppedwi thaL CDscreenf ordis
playi
ngt hedat a.I tisal
sopossi
bletoconnecttoa
SCADAs yst
em viaGPS/ GPRSorot hernetwor ksforremotemoni toringoft heunit
.

nor
I dert odes i
gnsuchas ol
uti
on,thef
oll
owingdatawouldgener
all
yberequi
red:
● adetail
eds peci
fi
cati
onofthetec
hnic
alcharac
ter
ist
icsoft
heequipmentt
obedeploy
edandpower
ed;
● meteorol
ogicaldataonthesi
teofins
tal
lat
ion;
●faci
lit
iesformount i
ngthesol
arpanel
.

16
Energofl
ow AG,
Ringst
rasse28,CH-
4600Ol
ten,Swi
tzer
land
T
el:+41622128907
F
ax:+41622128912
www.energofl
ow.c
om
sal
es@energofl
ow.com

You might also like