No: DISSTAI1AAA_STM
OTIS FIELD COMPONENT MANUAL
Page: 1/37
Engineering Center
‘Service Too! Manual
Shanghai
GCS ESC Control Software Dates a aene00e
GCS ESC Control Software
Service Too! Manual
Authorization Date D1: 01. Aug 2009
Running on PCB: DAA26800AH
Software Version: D1331411AAA
Document Revision vo.3
Date Author Page Comment
20108.2008_| F_ Wang Ta Original version
07.08.2008] F- Wang ba Yai removed from Display STST
<2>
Display SELFTST <2><3> re-
moved.No: DISBiAI1AAA STM
OTIS FIELD COMPONENT MANUAL,
Page: 5/37
Engineering Center
‘Shanghai
Service Too! Manual bate: 01 «Aug 2009
GCS ESC Control Software Ms Oath
2 Flow Chart Of General Menu Structure
‘Down
Interm (stopped) >
fadgust Maintenance =3
Statistic [banguage
teaed
lerrortegging=3
Starts a>
Date/tine
Lats
It's" is shown in the lower right corner of the display, the menu will continue on the next
screen, when GOON will be pressed
requires Customer password al password = 5
requires OTIS password (incl. Customer menus) at password = 5OTIS FIELD COMPONENT MANUAL,
Engineering Center
‘Shanghai
No.
Page:
Service Too! Manual .
GCS ESC Control Software ae
2.1. Escalator Service Tool Main Display
Attar the Escalator Service Tool is plugged, the main display is shown. The first line holds
different information, depending on the actual state of the system. The second line always
shows the operational mode. GOON will switch to the main menu.
2.4.1 Normal Operation
In normal operation the first line shows the selected direction (No Direction,
up oF Down)
Operational modes:
[waxm Up initialization after power on
Inspection Inspection operation with Inspection Tool
Locked Locked failure, reset via reset button
(Not Available [Noi Available normal failure
Idle Ready for operation
Continuous Continuous operation
Interm. (stopped) _| Intermittent operation Stopped
Interm. (running) _| Intermittent operation running
Restart Resiarl device is active
2.1.2 Errors and Warnings
If the system is in failure mode or maintenance is required, a appropriate message is
scrolled over the first ine of the display (see 3.8 Escalator Service Tool Error Messages ).
Error Message.
Not Available >
DISST411AAA STMOTIS
Engineering Center
Shanghai
FIELD COMPONENT MANUAL
Service Too! Manual
GCS ESC Control Software
No: DISS#I1AAA STM
Page: 7/37
Dale: 01 - Aug 2009
3 Escalator Service Tool Main Menu
‘The main menu is the root of the Escalator Service Tool menu.
3.1 Adjust
Adjust. =1
Statistic =2 >
‘GOON / GOBACK
Maintenance =3
Language = =4 >
GOON GOBACK
Password = =5
Serialnumber=6 >
‘GOON / GOBACK
oris
This menu holds submenus for adjusting the functionality of the system. In the future this
menu will be expanded with new features (i.e. healings).
3.1.1 Mode/Drive
‘GOON, GOBACK
Lubrication =3
Messages =4
8
8
This menu holds submenus for adjusting the operation mode of the escalator.
Mode =1
Drive =2 >
‘GOON GOBACK
Parameter =3No: DISBiAI1AAA STM
OTIS FIELD COMPONENT MANUAL,
Page: 8/37
Engineering Center
‘Shanghai
Service Too! Manual
GCS ESC Control Software
Dale: 01 - Aug 2009
3.1.1.4 Mode
‘Adjustment of the escalator operation mode by key input. The mode which is currently se-
lected is indicated by an *. Options will only be displayed when they are enabled by the
install parameters.
Continuous
*Intermitted=2 >
‘GOON | GOBACK
2 way =)
Acchange of the mode has to be confirmed.
Are You sure ?
Yes=
34.4.2 Drive
‘Adjustment of the drive operation mode by key input. The mode which is currently selected
is indicated by an *. Options will only be displayed when they are enabled by the install pa-
rameters.
Direct
*Y/D Start =2 >
‘GOON | GOBACK
ETA plus
‘Acchange of the made has to be confirmed.
‘Are You sure ?
Yes=No: DISBiAI1AAA STM
OTIS FIELD COMPONENT MANUAL,
Engineering Center
‘Shanghai
Page: 9/37
Service Too! Manual
GCS ESC Control Software
Dale: 01 - Aug 2009
3.1.1.3 Parameter
Adjustment of operation mode specific parameters. GOON/GOBACK will go through the
parameter list. Parameters will only be displayed when they are enabled by the install pa-
rameters. To modify a value, the new one has to be typed in and confirmed with ENTER.
star/Delta Delay
Ss <727 >
Display Uunit_| min. | max. | Description
Siar/Delta Delay s_| 4 | 10 | StavDelta start time
INT:LongRuntime | _s__| 31 | 256 | Long runtime in civection for intermitied and ETA + mode
Low Speed Time | (7208) | 1 | 240 | Time at low speed with VF standby
ETA:maxPersons | (#) | 1 | 31 | Estimated passengers for switching star to delta in ETA +
mode
ETA:minPersons | (#) | 0 | 30 | Estimated passengers for switching delia to star in ETA +
mode
A modification of a parameter has to be confirmed
3.1.2 Brake Distance
Are You sure ?
Yes=
The last brake distance can be marked either as the optimal (1) or as the maximal (2) dis-
tance. These values will be used in the maintenance menu (3.3.3 Brakedistance) to get in-
formation about the condition of the brake system.
Brakedst socom
Opt.=1 Max.=2No: DISBiAI1AAA STM
OTIS FIELD COMPONENT MANUAL,
Page: 10/37
Engineering Center
‘Shanghai
Service Too! Manual
GCS ESC Control Software
Dale: 01 - Aug 2009
3.1.3 Lubrication
Adjustment of the lubrication parameters. If the lubrication system is disabled by the install
parameters following Message is displayed.
Mech .Lubrication
system!
Otherwise GOON/GOBACK will go through the parameter list. To modify a value, the new
one has to be typed in and confirmed with ENTER.
WorkingTime Pump
6(*108) <-222 >
Display Uunit_| min. | max. | Description
WorkingTime Pump | (*10s) |_1 | 256 | Working time of pump
Pause Time Pump | hb | 0 _| 255 | Pause time of the pump
Work Time 2.vaive | _s | 0 | 255 | Working time second valve
Work. Daily Hour h | 0 | 24 | 0.29 = Dally hour to start lubrication (24 = not clock con-
trolled
Lubrication Test__| (ot) | 0 | 1 _| Lubrication test on (1) or off (0)
A modification of a parameter has to be confirmed
Are You sure ?
Yes=No: DISBiAI1AAA STM
OTIS FIELD COMPONENT MANUAL,
Engineering Center
‘Shanghai
Service Too! Manual
GCS ESC Control Software
Page: 11/37
Dale: 01 - Aug 2009
3.1.4 Messages
Adjustment of parameters affecting some kind of user
interface. GOON/GOBACK will go
through the parameter list. Parameters will only be displayed when they are enabled by the
install parameters. To modify a value, the new one has
ENTER
to be typed in and confirmed with
Buzzer Time
5s <-222>
Dispia Uunit_| min. | max. | Description
Buzzer Time s_| 0 | 255 | Buzzer time atter emergency stop button (0 = disabled)
ERMS address (| 0 | 255 | Address of escalator to ERMS-2 (0 = no ERMS-2)
OPICD Disp Mode | (ot) | 0 | 4 _| Display ‘OTIS’ on OPICP (1) or not (0)
A modification of a parameter has to be confirmed
Are You sure
Yes=
3.2 Statistics
‘This menu holds submenus with statistical information of
escalators operation
Passengers =1
Runtime
‘GOON | GOBACK
ErrorLogging=3
starts S|
‘GOON GOBACK,
Date/Time =:No: DISBiAI1AAA STM
OTIS FIELD COMPONENT MANUAL,
Page: 12/37
Engineering Center
‘Shanghai
Service Too! Manual
GCS ESC Control Software
Dale: 01 - Aug 2009
3.2.1 Passengers
Display of the passenger counters separated into total, per month, per week and per day.
GOON/GOBACK will go through the list.
Passengers total
yenanencc >
‘GOON GOBACK
Passengers/Month
2OOQOCOOKK >
‘GOON GOBACK
Passengers/Week
SOCCOGOOGKK >
‘GOON | GOBACK
engers/Day
SOG00G000K
3.2.2Runtime
Display of the runtime counter separated into total, and per week. GOON/GOBACK will go
through the list.
Runtime total
socpeococa: h >
‘GOON GOBACK
Runtime/Week
soopsecoca: hNo: DISBiAI1AAA STM
OTIS FIELD COMPONENT MANUAL,
Page: 19/37
Engineering Center
‘Shanghai
Service Too! Manual
GCS ESC Control Software
Dale: 01 - Aug 2009
3.2.3 Error Logging
Display of the chronological error memory. First date and time of the last deletion of the
memory is shown. Afterwards the numbered errors are shown, starting with the newest one.
GOON/GOBACK will go through the list.
Deleted since
‘T.MM.33 bh:mm >
‘G0oN | GOBACK
255:Last Error
TT.MMM bh:mm:ss>
%
001:First Brror.
TT.MM™M hh:mm:ss
‘GOON GOBACK
After the oldest error logged, it will be asked whether the memory should be deleted or not.
No More Errors
Delete=
GOON GORACK
Delete zrror ?
Yes=
3.2.4Starts
Display of the starts counters separated into total and per week. GOON/GOBACK will go
through the list
Starts total
yeogoo00G, >
‘GOON GOBACK
Starts/Week
2000000000.oTIs FIELD COMPONENT MANUAL |S DNS} SI¥
Page: 14/37
Engineering Center
‘Shanghai
Service Too! Manual bate: 01 «Aug 2009
GCS ESC Control Software Ms Oath
3.2.5Time and Date
Display of the system time. With GOON the adjustment mode can be started. To modify a
value, the new one has to be typed in and confirmed with ENTER.
Fri 03-Nov-2000
09:30:45 >
‘GOON GOBACK
Setup Time ?
‘GOON GOBACK
Hour (0. .23)
Ooh — <-727 >
Year, month, day, weekday, hour, minute and seconds have to be entered
3.3 Maintenance
This menu holds submenus with dynamic information about the escalators aperation. In the
future this menu can be expanded with new features (i.e. Temperature).
Motorspeed
Handrail = =2 >
‘GOON GOBAGK
Brakedist. =
3.3.1 Motorspeed
Display of the actual number of revolutions of the motor.
Motorspeed
2000 rpm
3.3.2Handrailspeed
Display of the actual handrail frequency.
Handrailspd [#2]
2 XK R: XXXoTIs FIELD COMPONENT MANUAL |S DNS} SI¥
Page: 15/37
Engineering Center
‘Shanghai
Service Too! Manual bate: 01 «Aug 2009
GCS ESC Control Software Ms Oath
3.3.3 Brakedistance
Display of the last brake distance and it's deviation to the maximal and optimal value, which
where adjusted under 3.1.2. GOON/GOBACK will go through the list.
Brake Distance
HOOOKK mm >
‘GOON | GOBACK
Diff. to Maximum
ECOG mm >
GOON | GOBACK
Diff. to optimum
AOCOGK mm.
3.4 Language
‘Adjustment of the Escalator Service Tool menu language by key input. The language which
is currently selected is indicated by an *. English and German are currently available but
further languages will be supported in the future
*English
Deutsch = =2