Professional Documents
Culture Documents
Sepam series 80
Intelligent solutions
Sepam series 60 for custom applications
Sepam series 40
High-performing solutions
for demanding applications
Sepam series 20
Simple solutions
Sepam series 10
for standard applications
Basic solutions
for simple applications
II. Modularity
III. Performance
IV. Simplicity
10 I / 8 O 50BF
S23 T23
1 comm. port
3V + V0 B21
81R B22
Basic +
M61
67N
Basic +
67N S62 T62 G62
67
Sepam series 20
● 1 communication port
Sepam series 40
● Current and voltage metering for all applications:
● all measurements available
● directional protection functions
● 1 communication port
II. Modularity
III. Performance
IV. Simplicity
For installation
in the most convenient
place for the user
● Sepam series 20 :
1 module / 8 temperature inputs
● Sepam series 40 :
2 modules / 16 temperature inputs
● MSA 141
● 0-10mA, 0-20mA or
4-20mA
To have one
remote measurement
Communication protocols :
● Modbus RTU
● DNP3
● IEC 60870-5-103
Physical interface:
● 2-wire RS 485
● 4-wire RS 485 (modbus only)
● Fiber optic
To connect Sepam to
communication network
● SFT2826,
disturbance recording data
display software
● 10 inputs / 8 outputs
(1 MES114 module)
● 1 analog output
(1 MSA141 module)
● 1 communication ports
(1 ACE interface)
II. Modularity
III. Performance
IV. Simplicity
● CT / VT supervision
● Operating temperature
from -25°C to +70°C
● Recloser co-ordination
● Inhibition of closing
A complete function,
dependable and ready to use!
● Boolean operators
NOT, AND, OR, XOR,
timers, latched relays,
time programmable pulses
● Syntax checking
Metering
All the measurements are
available:
● RMS and residual phase
currents
Pmax=3,2
E Active+
U21=
P=
I1=2,1
178A = MW
6,6
MW kVRMS
● Peak demand and average
currents tore= 5,2A
Io 755454
Qmax=1,0
I2=900k
Q=
U32= 6,6MW.h
177A VAr
kV
MVAr
RMS
● Phase-to-neutral, phase-to- E Active- =
phase and residual voltages S=
U13=
0I3=2,3
178A
50 6,6
72MVA kV
100MW.h
150%Ino
RMS
Switchgear diagnosis
Continuous, comprehensive breaking device
monitoring:
● Number of operations
● Operating time
● Charging time
CT / VT supervision
Permanent checking of the complete
measurement chain, from the CT and VT
sensors up to the Sepam analog inputs :
● Phase unbalance
● Tripping currents
● Alarm history
● Tripping context
Parallel S-LAN and E-LAN Two S-LAN networks and one E-LAN network
networks in parallel (Sepam series 80)
E-LAN
Legend
S-LAN network
Protocol selection :
Modbus, DNP3 or
IEC 60870-5-103
Physical interface :
2-wire or 4-wire RS 485,
fibre optic with star or
ring architecture
E-LAN network,
2-wire RS 485
Modem Modem
Simplified choice
● A consistent product range, organized by application
● Disconnectable
without any precautions
● Remote modules
● assembly on DIN rail
● connection via prefabricated
cords fitted with RJ45 plugs
To use at best
the available space!
● Screw type
or
To suit your
connection habits
● Windows environment
● On-line help
● Available in 4 languages,
customizable (French,
Spanish, English UK and US)
To derive maximum
benefit from your Sepam!
● Preparation of
● Sepam parameters
● protection settings
● File management
To reduce
commissioning time!
Local connection:
SFT2841 on laptop, connection
to advanced UMI by CCA783 cord E-LAN
@1 @2 @3 @4
Remote connection for
protection functions management
and network diagnosis:
SFT2841 on desktop connected
to Sepam units via E-LAN
CCA783
communication network
● Current operation
● Recovery of:
● parameters and
protection settings
● disturbance recording
records
● alarm history
To facilitate
servicing operations!
● Customization of alarm
messages on advanced UMI
● Customization of signal
lamp labels
More solutions
More modularity
More performance
More simplicity