Alarm and Event Reference Unm2000
Alarm and Event Reference Unm2000
Code: MN000000072
April 2013
Thank you for choosing our products.
Related Documentation
Document Description
I
Document Description
II
Version
Version Description
Intended Readers
u EPON technology
u GPON technology
u Ethernet technology
III
Conventions
Terminology Conventions
Terminology Convention
Symbol Conventions
Cascading
→ Connects multi-level menu options.
menu
IV
Symbol Meaning Description
Bidirectional
↔ The service signal is bidirectional.
service
Unidirectional
→ The service signal is unidirectional.
service
V
Contents
Preface...................................................................................................................I
Version ..........................................................................................................III
Conventions ................................................................................................. IV
1 Overview .....................................................................................................1-1
3.8.1 LINK_LOSS...................................................................3-32
3.8.2 Type Dismatch...............................................................3-34
3.8.3 MGC_DISCONNECTED................................................3-35
3.8.4 BATTERY_VOLTAGE_TOO_LOW.................................3-38
3.8.5 LOF...............................................................................3-39
3.8.6 PLOAM .........................................................................3-40
5.1.1 UP_CRC_ERROR_THRESHOLD /
DOWN_CRC_ERROR_THRESHOLD .............................5-2
5.1.2 UNDERSIZEFRAME_THRESHOLD ................................5-3
5.2.1 UP_CRC_ERROR_THRESHOLD /
DOWN_CRC_ERROR_THRESHOLD .............................5-4
5.2.2 UP_BIP8_OVER_THRESHOLD ......................................5-6
5.2.3 DOWN_BIP8_OVER_THRESHOLD ................................5-7
6 Prompt Alarms.............................................................................................6-1
6.2.1 ILEGAL_ONU_REGISTE.................................................6-6
6.2.2 ONU_AUTO_CONFIG_FAILED .......................................6-9
6.2.3 CPU_USAGE_OVER_THRESHOLD .............................6-10
6.2.4 MEM_USAGE_OVER_THRESHOLD ............................6-12
6.2.5 OPTMODULE_TEMP_OVER ........................................6-14
6.2.6 OPTMODULE_TEMP_OVER ........................................6-15
6.2.7 OPTMODULE_BIAS_OVER ..........................................6-16
6.2.8 OPTMODULE_TXPOWER_OVER ................................6-18
6.2.9 OPTMODULE_RXPOWER_OVER ................................6-20
6.2.10 ONU_TO_OLT_RXPOWER_OVER ...............................6-22
6.2.11 TOTAL_BANDWIDTH_OVER ........................................6-23
6.3.1 ILEGAL_ONU_REGISTE...............................................6-24
6.3.2 ONU_AUTO_CONFIG_FAILED .....................................6-27
6.3.3 CPU_USAGE_OVER_THRESHOLD .............................6-28
6.3.4 MEM_USAGE_OVER_THRESHOLD ............................6-30
6.3.5 ONU_UNAUTHENTICATED ..........................................6-32
6.3.6 OPTMODULE_TEMP_OVER ........................................6-33
6.3.7 OPTMODULE_TEMP_OVER ........................................6-34
6.3.8 OPTMODULE_BIAS_OVER ..........................................6-35
6.3.9 OPTMODULE_TXPOWER_OVER ................................6-37
6.3.10 OPTMODULE_RXPOWER_OVER ................................6-39
6.3.11 ONU_TO_OLT_RXPOWER_OVER ...............................6-40
6.3.12 TOTAL_BANDWIDTH_OVER ........................................6-41
6.8.1 OPTICAL_POWER_LOW..............................................6-53
6.8.2 PROTECT_VOICE_SERVICE_ONLY ............................6-54
6.8.3 User_defined_alarm1 to User_defined_alarm5...............6-55
6.8.4 DOW .............................................................................6-56
6.8.5 SF .................................................................................6-57
6.8.6 SD.................................................................................6-58
6.8.7 LCDG ............................................................................6-59
6.8.8 RDI................................................................................6-60
6.8.9 SUF...............................................................................6-62
6.8.10 LOA...............................................................................6-63
6.8.11 MEM..............................................................................6-64
6.8.12 PEE...............................................................................6-65
6.8.13 MIS ...............................................................................6-67
7 Critical Events..............................................................................................7-1
7.1.1 OLT_REGISER_FAILED..................................................7-2
7.1.2 License_Esn_Fail ............................................................7-2
7.2.1 PULL_OUT_CARD..........................................................7-3
7.2.2 INSERT_CARD ...............................................................7-4
7.3.1 HG_REGISTER_FAILED.................................................7-5
7.3.2 ONU_REGISTER_FAILED ..............................................7-5
7.3.3 UPGRADE_FILE_DISMATCH .........................................7-6
7.3.4 UPGRADE_FAILURE ......................................................7-7
7.3.5 AUTO_UPGRADE_FAILURE ..........................................7-8
9.1.1 CPU_INVERSION_SUCCESSFUL..................................9-2
9.1.2 HSWA_STATUS_SWITCH ..............................................9-3
9.1.3 UPLINK_INVERSION ......................................................9-3
9.1.4 SIGNAL_TRACE .............................................................9-4
9.1.5 TIME_REQ......................................................................9-4
9.1.6 COLD_START .................................................................9-5
9.1.7 TIME_ACK ......................................................................9-6
9.1.8 HG_REGISTER...............................................................9-6
9.1.9 OLT_REGISTER .............................................................9-7
9.1.10 PEER_INSERT ...............................................................9-7
9.1.11 PRECONFIG REQUEST .................................................9-8
9.1.12 LINECARD_SWITCH ......................................................9-8
9.1.13 ACTIVE_STANDBY_CARD_SYNCHRONIZING ..............9-9
9.1.14 ACTIVE_STANDBY_CARD_SYNCHONIZE_FINISH .......9-9
9.2 Prompt Events of the EC4B / EC8B / XG2B / GC4B / GC8B Card .9-10
9.2.1 PON_PORT_PROTECTION_GROUP_STATU-
S_CHANGE ..................................................................9-10
9.2.2 PRE_REGISTER_FAILURE ..........................................9-11
9.2.3 PON_INVERSION_SUCCESSFUL................................9-12
9.2.4 PON_INVERSION_FAILED ...........................................9-12
Figure 1-1 Location of the ESD Protection Sign and Subrack Earth Ground
Sign...............................................................................................1-3
Figure 1-2 Wearing the ESD Protection Wrist Strap.........................................1-4
Figure 1-3 Plugging a Card .............................................................................1-5
Figure 1-4 The Dedicated Fiber Puller.............................................................1-6
Figure 1-5 No Access to Internet.....................................................................1-9
Figure 1-6 Do not Modify Computer Component............................................1-10
Figure 1-7 Do not Modify Protocol Settings ...................................................1-10
Figure 1-8 Do not Modify Computer Name ....................................................1-11
Figure 1-9 Do not Modify LAN Settings .........................................................1-11
Tables
The following introduces the basic information such as the definitions of alarms and
events, and handling principles.
Safety Precautions
Alarm Definition
Alarm Level
Event Definitions
Event Level
Version: D 1-1
AN5116-06B Optical Line Terminal Equipment Alarm and Event Reference
Operators should know the meanings of the security and warning signs on the
AN5116-06B. Table 1-1 lists the meanings and positions of the signs.
The following uses the subrack as an example to introduce the locations of the ESD
protection sign and the subrack earth ground sign.
1-2 Version: D
1 Overview
Figure 1-1 Location of the ESD Protection Sign and Subrack Earth Ground Sign
The ESD protection wrist strap is an accessory of the equipment. Make sure that the
metal fastener of ESD protection wrist strap is in good contact with the skin and the
other end of wrist strap is correctly connected to the ESD protection earth ground
fastener on the cabinet, as shown in Figure 1-2.
Version: D 1-3
AN5116-06B Optical Line Terminal Equipment Alarm and Event Reference
u Before plugging or unplugging a card, wear the ESD protection gloves or the
ESD protection wrist strap and keep both hands dry and clean.
u Do not touch the circuitry, components, or wiring trough when handling the
cards.
4 Before plugging the card, confirm that the corresponding slot is available.
4 Before plugging the card, confirm that cables or optical fibers are not
connected with the card.
4 Before plugging the card, confirm the insertion direction of the card. Do not
insert the card in the opposite direction. The insertion direction of the card
is shown in Figure 1-3.
4 Use care when plugging the card to avoid distorting pins on the backplane.
1-4 Version: D
1 Overview
4 Slide the card along the slide rails of the slot, so as to prevent the
components on the board from contacting each other and causing shorting.
See Figure 1-3 for the card installation.
u Before unplugging the card, confirm the card is not carrying services.
Unplugging the card with services may cause service interruption.
Optical fibers are easily damaged if they are plugged or unplugged by hands without
using any tool. The operators should use the dedicated fiber puller to avoid damage
to optical fiber and fiber connector caused by rough handling.
Caution:
The dedicated fiber puller is required for plugging and unplugging fibers.
The fiber puller is shipped with the AN5116-06B and looks like a nipper and has a
spring cord, as shown in Figure 1-4.
The fiber puller is secured on the cabinet with a spring cord before delivery. By
clipping the fiber connector with the special fiber puller, you can plug or unplug the
fiber very conveniently.
Version: D 1-5
AN5116-06B Optical Line Terminal Equipment Alarm and Event Reference
(1) Spring cord (2) Buckle it into the mounting hole on the
vertical mounting flange
If the pigtail’s output optical power is unknown, please do not insert the optical
module into the card’s optical interface directly. Put the module in the interface
without connecting them, or add an attenuator, so as to avoid damage on the optical
module.
u Check the optical power before connecting the optical fibers; only if the optical
power meets the requirement can the fibers be connected. The equipment
optical power parameters are shown in Product Description.
u Before connecting optical fibers, check whether the optical fiber connector
matches the optical interface. If the optical fiber connector does not match the
optical interface, use a compatible connector.
Protecting Eyes
Looking the optical output interface or the end of the pigtail connected with the
output interface directly will harm your eyes. Never get close to or look directly at the
optical interface or optical fiber connector.
1-6 Version: D
1 Overview
The optical power may be affected if the fiber is bent or pressed with excessive
force. The bend radius should be no less than 38 mm.
u Cover the optical interfaces and optical connectors of the pigtail fibers that are
not in use with anti-dust caps. This can avoid eye injuries caused by a direct
and unintentional look into the optical interfaces or optical connectors, and
prevent dust from entering the optical interfaces or contaminating the optical
connectors.
u Cover the optical interfaces of the replaced cards with anti-dust caps to keep
the optical interfaces clean.
Cleaning
The following lists some common cleaning tools for operation engineers.
u Dedicated cleaning solvent (the first choice is the isoamyl alcohol and the
second choice is the propyl alcohol)
Version: D 1-7
AN5116-06B Optical Line Terminal Equipment Alarm and Event Reference
Shorting
u When a shorting occurs, a quick, significant rise in the current will easily result
in damage to the equipment and unforeseen safety problems.
u During operation, avoid metal fillings, water and other conductive materials into
the in-service equipment so as to prevent damage to electrical apparatus and
components caused by shorting.
Grounding
u Confirm that the protection earth ground bar in the equipment room is grounded
properly.
Power Supply
u Before removing the power cable, confirm that the power supply is
disconnected.
u Never expose the power cable. The unnecessary uninsulated parts should be
completely covered with an insulating tape.
u When the operation conditions permit, first disconnect the power supply, and
then conduct other operations.
u Use UPS power supply to avoid loss of network management data caused by
accidental power failure.
u The computer case, UPS power supply and switch (or hub) should be
connected to protection earth ground.
1-8 Version: D
1 Overview
u To shut down the network management computer, first exit the operation
system normally and then shut off the power supply.
u The network management computer cannot be used for purposes other than
network management. Use of unidentified memory devices should be
prohibited so as to avoid computer viruses.
u Do not delete any file in the network management system randomly or copy
any irrelevant file into the network management computer.
u Do not visit Internet via the network management computer. Doing so may
increase data flow in the net card and hence affects normal network
management data transmission or results in other accidents.
Version: D 1-9
AN5116-06B Optical Line Terminal Equipment Alarm and Event Reference
1-10 Version: D
1 Overview
Version: D 1-11
AN5116-06B Optical Line Terminal Equipment Alarm and Event Reference
The alarm is the notice and alert of a system parameter reaching a certain threshold.
Therefore, users must handle all alarms generated in the system immediately, so as
to minimize fault occurrence, and improve the network quality.
For handling alarms, users must follow certain principles, so as to eliminate alarms
and faults in the shortest possible time.
Instruction
Restoring First and Preparing Second is to restore the services first by switching
it to the protection path or the standby card and then repair faults. The prerequisite
of this principle is that a protection path or a standby card for the faulty working path
or the card exists in the system.
Application Range
This principle is mainly applicable for handling the alarms influencing services.
Instruction
External first and equipment second is to exclude possible external faults (such
as the broken fiber, terminal equipment fault, power supply fault, or equipment room
environment problem) when handling alarms, and then consider faults of this
equipment.
Application Range
1-12 Version: D
1 Overview
Instruction
Higer level first and lower level second is to analyze the alarm with higher level,
such as the critical alarm and major alarm first and then the alarm with lower level,
such as the minor alarm and prompt alarm in the course of alarm analysis. When
handling alarms, users should handle the alarm influencing services first; if this
alarm is caused by the alarm with higher level, then handle the alarm with higher
levels first.
Application Range
This principle is applicable for handling alarms when higher level alarms and lower
level alarms exist at the same time.
Instruction
Majority first and minority second is to handle the majority of alarms of the same
type existing in the network management system first. The handling methods of the
same type alarms are probably the same. After the majority of alarms of the same
type are eliminated, the alarms in the network management system will be reduced
greatly. And this helps the supervision and maintenance staff analyze and judge the
valid alarms.
Application Range
This principle is applicable for handling alarms when the majority of the existing
alarms are of the same type.
Generally, alarms has four levels: critical alarm, major alarm, minor alarm and
prompt alarm.
Version: D 1-13
AN5116-06B Optical Line Terminal Equipment Alarm and Event Reference
u Critical alarm: Refers to the alarm influencing service severely and needing
immediate troubleshooting.
u Minor alarm: Refers to the alarm not influencing services but needing
troubleshooting when the traffic is relatively small to avoid deterioration.
u Prompt alarm: Refers to the alarm not influencing current services but having
the possibility to influence services, users can decide whether to handle it or
not as needed.
The event is the notice of the operations related to the system. Users should handle
the events according to their levels and contents: For the critical event, users should
handle it immediately; and for the prompt event, users only need to execute the
corresponding operation or simply omit it . Handling events should comply with the
relevant rules; users should find out the causes of triggering an event first, and then
adopt the suitable measures.
Events generally have four levels: Critical event, major event, minor event and
prompt event.
u Major event: Refers to the operation or faults possibly influencing the service
and needing troubleshooting.
u Minor event: Refers to the operation or faults not influencing services but
needing troubleshooting when the traffic is relatively small to avoid
deterioration.
u Prompt event: Refers to the operation or faults not influencing current services
but having the possibility to influence services, users can decide whether to
handle it or not as needed.
1-14 Version: D
2 Basic Operation
Viewing Events
Version: D 2-1
AN5116-06B Optical Line Terminal Equipment Alarm and Event Reference
This command is used to query current alarms of the selected object and its sub-
objects. The current alarms include all alarms that have not ended and are not
confirmed by users.
Applicable Object
This command is applicable to the system, module, HSWA card, EC4B / EC8B /
GC4B / GC8B / XG2B card and their PON ports, CE1B card, C155A card and its
STM-1 optical interfaces, HU1A / HU2A / GU6F card and its uplink ports, PUBA
card, FAN card, ONU and its LAN ports.
Prerequisites
Procedure
1. Open the Current Alarm window according to the corresponding path listed in
Table 2-1.
2-2 Version: D
2 Basic Operation
Result
The Current Alarm tab displays the NE / object to be queried, system IP address,
equipment type, alarm name, alarm type, alarm beginning and ending time, alarm
confirmation time, the user confirming an alarm, and alarm confirming information.
Users can handle relevant alarms based on the information displayed in this tab.
This command is used to confirm the current alarm information, indicating that this
alarm has been noticed and is being handled.
Applicable Object
Prerequisites
Procedure
1. Open the Current Alarm tab according to the corresponding path listed in
Table 2-1 and then right-click a certain alarm item.
4 Select Alarm Confirm in the shortcut menu to confirm the current alarm.
Operation Result
u If an alarm has not ended, the alarm will still be displayed in the Current Alarm
tab after being confirmed.
u If an alarm has ended, it can be viewed in the Historical Alarm tab after being
confirmed.
Version: D 2-3
AN5116-06B Optical Line Terminal Equipment Alarm and Event Reference
This command is used to query history alarms of the selected object and its sub-
objects. The history alarms include all alarms that have ended and have been
confirmed by users or by the system automatically.
Applicable Object
This command is applicable to the system, module, HSWA card, EC4B / EC8B /
GC4B / GC8B / XG2B card and their PON ports, CE1B card, C155A card and its
STM-1 optical interfaces, HU1A / HU2A / GU6F card and its uplink ports, PUBA
card, FAN card, ONU and its LAN ports.
Prerequisites
Procedure
1. Open the Historical Alarm window according to the corresponding path listed
in Table 2-2.
2-4 Version: D
2 Basic Operation
Result
The Historical Alarm tab displays the NE / object to be queried, system IP address,
equipment type, alarm name, alarm type, start and end times, duration, alarm
confirmation time, user confirmation and confirmation information.
This command is used to configure the custom alarm names for dry contacts.
Applicable Object
Prerequisites
Procedures
2. Select the PUBA card or the ONU from the object tree in the left pane.
3. Click the line where the alarm needs configuring in the right side of the pane.
4. Click the blank under the Alarm English Name item, and then select the alarm
name in the drop-down list and the English name will automatically appear.
Version: D 2-5
AN5116-06B Optical Line Terminal Equipment Alarm and Event Reference
Note:
For the PUBA card, 14 custom alarm items can be defined; for the FTTH
type ONU, two custom alarm items can be defined; for the FTTB type
ONU, five custom alarm items can be defined.
6. Click Operation→Apply to same type device check box in the shortcut menu
to deliver the custom alarm names to equipments with the same type in the
system.
Result
As soon as a certain custom alarm is reported to the ANM2000, the ANM2000 will
display this defined alarm name.
This command is used to view the default names and custom names for custom
alarms of dry contacts.
Applicable Object
Prerequisites
2-6 Version: D
2 Basic Operation
Procedures
2. Select the object to be queried from the Object tree in the left pane.
Result
The right pane of the Custom alarm manage window displays the default names
and custom names of custom alarms.
This command is used to set the reporting conditions for custom alarms.
Applicable Object
Prerequisites
Procedure
1) Click the PUBA card in the Object Tree pane and select Config→Service
Config Management in the menu bar to access the Service Config
Management window.
Version: D 2-7
AN5116-06B Optical Line Terminal Equipment Alarm and Event Reference
3) Select Edit→Append or click the Add button in the menu bar to get the
Please Input The Rows For Add: dialog box; and then input 1 in the
dialog box and click OK to create an item.
4) Input the alarm interface No. in the Interface No. column, and select the
alarm reporting condition in the drop-down list of the Alarm Report
Condition item.
1) Click the PON interface connected to the ONU in the Object Tree pane
and select Config→Service Config Management in the menu bar to
access the Service Config Management window.
2) Click the ONU under the interface card in the Remote Object tab in the
Object Tree pane, and select Config→Custom Alarm Config in the
Menu Tree pane.
3) Select Edit→Append or click the Add button in the menu bar to get the
Please Input The Rows For Add: dialog box; and then input 1 in the
dialog box and click OK to create an item.
4) Input the alarm interface No. in the Interface No. column, and select the
alarm reporting condition in the drop-down list of the Alarm Report
Condition item.
Result
When each alarm interface detects the level meeting the reporting conditions, the
alarm will be generated and reported to the network management system.
This command is used to query the event information of the selected object and its
sub-object.
2-8 Version: D
2 Basic Operation
Applicable Object
This command is applicable to the system, module, HSWA card, C4B / EC8B /
GC4B / GC8B / XG2B card and their PON ports, CE1B card, C155A card, STM-1
optical interfaces, HU1A / HU2A / GU6F card and its uplink ports, PUBA card, FAN
card, ONU and its LAN ports.
Prerequisites
Procedure
2. Select the corresponding query conditions in the Event Report tab that
appears to query all events which meet the condition.
Result
The Event Report tab displays the object, event level and starting time of the event
to be queried. Query according to these items.
Version: D 2-9
3 Critical Alarms
The following introduces the critical alarms might be generated by the equipment.
Version: D 3-1
AN5116-06B Optical Line Terminal Equipment Alarm and Event Reference
The following introduces the critical alarms might occur in the HSWA card and the
handling procedure.
3.1.1 CPU_INVERSION_FAILED
Alarm Information
Alarm Name Alarm Level Alarm Type
If the system automatically or manually forced switching between the active and
standby HSWA cards fails, the system will still use the faulty active HSWA card,
resulting in the system service interruption and the OLT failure for providing any
service.
Possible Cause
Handling Procedure
Caution:
If the switching failure occurs on the HSWA card, reset the standby
HSWA card or perform manually forced switching operation. Even if the
switching is successful, the configuration may be lost or service
interruption occurs. It is recommended to contact FiberHome for technical
support if the switching failure occurs in the HSWA card.
1. Check whether the standby HSWA card is inserted into the equipment.
3-2 Version: D
3 Critical Alarms
4 If yes, ➔ Step 2.
4 If no, save the active HSWA card configuration to Flash and then insert the
standby one, ➔ Step 4.
2. Check whether the standby HSWA card is present or not in the ANM2000.
4 If no,➔ Step 3.
4 If yes,➔ Step 4.
1) Right-click the system in the Object Tree pane, and select Detect
Physical Configuration from the shortcut menu to bring up the Detect
Physical Configuration dialog box.
2) Click the Detect Physical Configuration button in the menu bar to detect
the system physical configuration.
4. Check the status of the ACT indicator LED on the standby HSWA card:
4 If the LED blinks slowly, the standby HSWA card is not ready to switch.
Wait a moment and execute the switching between the active and standby
HSWA cards again after the LED became ON.
5. Check whether the active HSWA card works normally, using the Get
Information command to query whether each parameter is normal:
4 If the active HSWA card does not work normally, ➔ Step 6 for the forced
switching.
4 If the active card works normally, contact FiberHome for technical support.
4 If not, stop the current operation and contact FiberHome for technical
support.
Version: D 3-3
AN5116-06B Optical Line Terminal Equipment Alarm and Event Reference
3.1.2 TIME_HAVENT
Alarm Information
Alarm Name Alarm Level Alarm Type
Possible Cause
Handling Procedure
1) Click the HSWA card in the Object Tree pane and select Config→Service
Config Management in the menu bar to access the Service Config
Management window.
¡ If no, ➔ Step 2.
1) Click the system in the Object Tree pane and select Config→Service
Config Management in the menu bar to access the Service Config
Management window.
3-4 Version: D
3 Critical Alarms
Note:
3) Repeat Step 1 to check whether the equipment time synchronizes with the
ANM2000.
3.1.3 TIME_LOSS
Alarm Information
Alarm Name Alarm Level Alarm Type
The AN5116-06B cannot obtain clock signals from the NTP time server.
Possible Cause
The communication between the equipment and the NTP time server interrupts.
Handling Procedure
1. Check whether the physical connection between the uplink interface and the
NTP time server is normal.
4 If the physical connection fault occurs, repair the connection from the
uplink interface to the NTP server.
Version: D 3-5
AN5116-06B Optical Line Terminal Equipment Alarm and Event Reference
3.1.4 TEMPERATURE_OVER
Alarm Information
Alarm Name Alarm Level Alarm Type
Possible Cause
Handling Procedure
2. Check whether too much dust gathers inside the fan unit or the ventilation and
air cooling may be hindered:
3. Check whether the air conditioner at the equipment site works normally:
4 If yes, ➔ Step 5.
3-6 Version: D
3 Critical Alarms
1) Click the HSWA card in the Object Tree pane and select Config→Service
Config Management in the menu bar to access the Service Config
Management window.
3.1.5 STANDBY_POWER_INPUT_FAIL
Alarm Information
Alarm Name Alarm Level Alarm Type
The active and standby power supply loss occurs at same time, and the AN5116-
06B fails to work.
Possible Cause
Handling Procedure
1. Check whether the standby power supply's supply line has faults.
4 If no, ➔ Step 2.
2. Check whether the standby power supply's 220V mains supply is cut off.
Version: D 3-7
AN5116-06B Optical Line Terminal Equipment Alarm and Event Reference
4 If the 220V mains supply is cut off, contact the local power supply
department for troubleshooting.
3.1.6 FAN_ERROR
Alarm Information
Alarm Name Alarm Level Alarm Type
The fan failure may cause the poor heat dissipation for the whole system. If the
equipment works in this situation for a long time, the system cannot keep running
stably, and even hardware faults may occur.
Possible Cause
Handling Procedure
4 If yes, ➔ Step 2.
4 If yes, clear the dust. If the alarm is removed after the cleaning, no
handling is needed; If the alarm persists, ➔ Step 3.
3. Replace the faulty fan unit complying with the operation specification and make
the correct cable connection:
3-8 Version: D
3 Critical Alarms
3.1.7 License_RESOURCE_LOW_ALARM
Alarm Information
Alarm Name Alarm Level Alarm Type
Possible Cause
Handling Procedure
1) Click the HSWA card in the Object Tree pane and select Config→Service
Config Management in the menu bar to access the Service Config
Management window.
3) View whether the value of Maximum Resource is lower than the value of
Applied Resource.
a) If yes, ➔ Step 2.
1) Click the HSWA card in the Object Tree pane and select Config→Service
Config Management in the menu bar to access the Service Config
Management window.
2) Select License→Esn Query in the Menu Tree to open the Esn Query
tab.
Version: D 3-9
AN5116-06B Optical Line Terminal Equipment Alarm and Event Reference
6) Set the parameters and click Create on Device to download the License
to the equipment.
3.1.8 OLT_DISCOVER_LOOP
Alarm Information
Alarm Name Alarm Level Alarm Type
Different loops have different influence on the equipment. Maybe only single ONU
service is influenced, or the card connection or the entire system services are
influenced.
Possible Cause
The OLT detects that loop exists between the core switch ports, slots, and between
slot and uplink port.
Handling Procedure
1. Click the HSWA card in the Object Tree pane and select Config→Service
Config Management in the menu bar to access the Service Config
Management window.
2. Select Get Information→Get Loop Detect Table in the Menu Tree pane to
open the Get Loop Detect Table tab.
3-10 Version: D
3 Critical Alarms
The following introduces the critical alarms might occur in the EC4B / EC8B / XG2B
card and the handling procedure.
3.2.1 CARD_NOT_PRESENT
Alarm Information
Alarm Name Alarm Level Alarm Type
u The ANM2000 or the CLI (Command Line Interface) cannot issue any
command to the card located in this slot successfully.
u All services loaded on this card are interrupted; and the card cannot provide
any service.
Possible Cause
Handling Procedure
4 If the card is unplugged, check the card and insert it again. If the alarm is
removed, no handling is needed; if the alarm still persists, ➔ Step 2.
2. Check whether the card is faulty and whether the ALARM LED on the card is
ON:
4 If the ALM indicator LED on the card is illuminated, replace the card.
Version: D 3-11
AN5116-06B Optical Line Terminal Equipment Alarm and Event Reference
3.2.2 LINK_LOSS
Alarm Information
Alarm Name Alarm Level Alarm Type
Possible Cause
u The optical fiber connected with the PON port (i.e. the fiber link between the
PON port and the splitter) is damaged.
Handling Procedure
1. Detect the optical module of the PON port with an optical power meter:
4 If the optical power is too low or no optical signal exists, the optical module
has faults. Replace the card.
2. Detect the optical fiber (from the PON port to the splitter) with an optical power
meter:
4 If the optical power is too low or no optical signal exists, the fiber link or the
splitter has faults. Repair the physical link.
3.2.3 PHYSIC_ID_CONFLICT
Alarm Information
Alarm Name Alarm Level Alarm Type
3-12 Version: D
3 Critical Alarms
The system cannot authorize the ONUs which use the conflict physical IDs.
Possible Cause
The physical IDs of ONUs under the current EC4B / EC8B / XG2B card’s PON port
conflict with those of the authorized ONUs in the system.
Handling Procedure
1. Check the validity of the two ONUs whose physical identifiers conflict with each
other. Turn off the power of the illegal ONU under the current PON port, change
the ONU terminal and unauthorize the current authorized ONU.
3.2.4 LOGICAL_ID_CONFLICT
Alarm Information
Alarm Name Alarm Level Alarm Type
The system cannot authorize the ONUs which use the conflict logical IDs.
Possible Cause
The logical IDs of ONUs under the current EC4B / EC8B / XG2B card’s PON port
conflict with those of the authorized ONUs in the system.
Handling Procedure
1. Check the validity of the ONUs whose logical IDs conflict with each other. Turn
off the power of the illegal ONU under the current PON port, change the serial
number of the ONU and unauthorize the current authorized ONU.
Version: D 3-13
AN5116-06B Optical Line Terminal Equipment Alarm and Event Reference
3.2.5 OPTMODULE_NOT_PRESENT
Alarm Information
Alarm Name Alarm Level Alarm Type
u The EC4B / EC8B / XG2B card cannot detect the ONU of the PON interface.
u Services of the PON interface on the EC4B / EC8B / XG2B card are abnormal.
Possible Cause
Handling Procedure
4 If no, ➔ Step 2.
3.2.6 LASER_ALWAYS_ON
Alarm Information
Alarm Name Alarm Level Alarm Type
3-14 Version: D
3 Critical Alarms
u The ONU transmits optical signals repetitively and the OLT cannot resolve the
optical signals.
u Except this ONU, all ONU services of the PON interface are interrupted.
Possible Cause
Handling Procedure
1. Check whether the ONU authorized number and the physical ID exist in the
additional alarm information of the LASER_ALWAYS_ON alarm.
4 If no, unplug every branch fiber connected to the splitter and then insert
into the optical power detector to check whether the ONU emits light.
¡ If the optical power meter receives the optical signal, the laser of the
ONU is normal. Replace the ONU.
The following introduces the critical alarms might occur in the GC4B / GC8B card
and the handling procedure.
Version: D 3-15
AN5116-06B Optical Line Terminal Equipment Alarm and Event Reference
3.3.1 CARD_NOT_PRESENT
Alarm Information
Alarm Name Alarm Level Alarm Type
u The ANM2000 or the CLI (Command Line Interface) cannot issue any
command to the card located in this slot successfully.
u All services loaded on this card are interrupted; and the card cannot provide
any service.
Possible Cause
Handling Procedure
4 If the card is unplugged, check the card and insert it again. If the alarm is
removed, no handling is needed; if the alarm still persists, ➔ Step 2.
2. Check whether the card is faulty and whether the ALARM LED on the card is
ON:
4 If the ALM indicator LED on the card is illuminated, replace the card.
3.3.2 LINK_LOSS
Alarm Information
Alarm Name Alarm Level Alarm Type
3-16 Version: D
3 Critical Alarms
Possible Cause
u The optical module of the PON port on the GC4B / GC8B card is faulty.
u The optical fiber connected with the PON port (i.e. the fiber link between the
PON port and the splitter) is damaged.
Handling Procedure
1. Detect the optical module of the PON port on the GC4B / GC8B card with an
optical power meter:
4 If the optical power is too low or no optical signal exists, the optical module
has faults. Replace the card.
2. Detect the optical fiber (from the PON port to the splitter) with an optical power
meter:
4 If the optical power is too low or no optical signal exists, the fiber link or the
splitter has faults. Repair the physical link.
3.3.3 Optical_Module_Not_Identical
Alarm Information
Alarm Name Alarm Level Alarm Type
u The GC4B/GC8B card cannot detect the ONU of the PON interface.
Version: D 3-17
AN5116-06B Optical Line Terminal Equipment Alarm and Event Reference
Possible Cause
Handling Procedure
1. Unplug the optical module of the fault PON interface on the GC4B/GC8B card.
Detect whether the optical module type is 2.5G GPON optical module.
4 If the optical module type is faulty, replace the 2.5G GPON optical module.
4 After replacing the optical module in the same type, faults are removed
and no other handling is needed.
4 After replacing the optical module in the same type, the fault persists and
the PON interface of the card has faults, please contact FiberHome for
technical support.
3.3.4 OPTMODULE_NOT_PRESENT
Alarm Information
Alarm Name Alarm Level Alarm Type
u The GC4B/GC8B card cannot detect the ONU of the PON interface.
Possible Cause
Handling Procedure
3-18 Version: D
3 Critical Alarms
4 If no, ➔ Step 2.
3.3.5 PHYSIC_ID_CONFLICT
Alarm Information
Alarm Name Alarm Level Alarm Type
This alarm does not influence the system; but the system cannot authorize the
ONUs which use the conflict physical IDs.
Possible Cause
The physical IDs of ONUs under the current GC4B / GC8B card’s PON port conflict
with those of the authorized ONUs in the system.
Handling Procedure
1. Check the validity of the two ONUs whose physical IDs conflict with each other.
Turn off the power of the illegal ONU under the current PON port, change the
ONU terminal and unauthorize the current authorized ONU.
3.3.6 LOGICAL_ID_CONFLICT
Alarm Information
Alarm Name Alarm Level Alarm Type
Version: D 3-19
AN5116-06B Optical Line Terminal Equipment Alarm and Event Reference
The system cannot authorize the ONUs which use the conflict logical IDs.
Possible Cause
The logical IDs of ONUs under the current GC4B / GC8B card’s PON port conflict
with those of the authorized ONUs in the system.
Handling Procedure
1. Check the validity of the ONUs whose logical IDs conflict with each other. Turn
off the power of the illegal ONU under the current PON port, change the serial
number of the ONU and unauthorize the current authorized ONU.
3.3.7 PHYSICAL_PASSWORD_CONFLICT
Alarm Information
Alarm Name Alarm Level Alarm Type
The system cannot authorize the ONUs which use the conflict physical passwords.
Possible Cause
The physical passwords of ONUs under the current GC4B / GC8B card’s PON port
conflict with those of the authorized ONUs in the system.
Handling Procedure
1. Check the validity of the ONUs whose physical passwords conflict with each
other. Turn off the power of the illegal ONU under the current PON port, change
the serial number of the ONU and unauthorize the current authorized ONU.
3-20 Version: D
3 Critical Alarms
3.3.8 LASER_ALWAYS_ON
Alarm Information
Alarm Name Alarm Level Alarm Type
u The ONU transmits optical signals repetitively and the OLT cannot resolve the
optical signals.
u Except this ONU, all ONU services of the PON interface are interrupted.
Possible Cause
Handling Procedure
1. Check whether the ONU authorized number and the physical ID exist in the
additional alarm information of the LASER_ALWAYS_ON alarm.
4 If no, unplug every branch fiber connected to the splitter and then insert
into the optical power detector to check whether the ONU emits light.
¡ If the optical power meter receives the optical signal, the laser of the
ONU is normal. Replace the ONU.
Version: D 3-21
AN5116-06B Optical Line Terminal Equipment Alarm and Event Reference
The following introduces the critical alarms might occur in the PUBA card and the
handling procedure.
3.4.1 CARD_NOT_PRESENT
Alarm Information
Alarm Name Alarm Level Alarm Type
u The ANM2000 or the CLI (Command Line Interface) cannot issue any
command to the card located in this slot successfully.
Possible Cause
The PUBA card is unplugged from the equipment or the PUBA card in the
equipment is faulty.
Handling Procedure
4 If the card is unplugged, check the card and insert it again. If the alarm is
removed, no handling is needed; if the alarm still persists, ➔ Step 2.
2. Check whether the card is faulty and whether the ALARM LED on the card is
ON:
4 If the ALM indicator LED on the card is illuminated, replace the card.
3-22 Version: D
3 Critical Alarms
The following introduces the critical alarms might occur in the CE1B card and the
handling procedure.
3.5.1 CARD_NOT_PRESENT
Alarm Information
Alarm Name Alarm Level Alarm Type
u The ANM2000 or the CLI (Command Line Interface) cannot issue any
command to the card located in this slot successfully.
Possible Cause
The CE1B card is unplugged from the equipment or the CE1B card in the equipment
is faulty.
Handling Procedure
4 If the card is unplugged, check the card and insert it again. If the alarm is
removed, no handling is needed; if the alarm still persists, ➔ Step 2.
2. Check whether the card is faulty and whether the ALARM LED on the card is
ON:
4 If the ALM indicator LED on the card is illuminated, replace the card.
Version: D 3-23
AN5116-06B Optical Line Terminal Equipment Alarm and Event Reference
The following introduces the critical alarms might occur in the C155A card and the
handling procedure.
3.6.1 CARD_NOT_PRESENT
Alarm Information
Alarm Name Alarm Level Alarm Type
u The ANM2000 or the CLI (Command Line Interface) cannot issue any
command to the card located in this slot successfully.
Possible Cause
The C155A card is unplugged from the equipment or the C155A card in the
equipment is faulty.
Handling Procedure
4 If the card is unplugged, check the card and insert it again. If the alarm is
removed, no handling is needed; if the alarm still persists, ➔ Step 2.
2. Check whether the card is faulty and whether the ALARM LED on the card is
ON:
4 If the ALM indicator LED on the card is illuminated, replace the card.
3-24 Version: D
3 Critical Alarms
3.6.2 155_OPTICAL_LOS
Alarm Information
Alarm Name Alarm Level Alarm Type
Possible Cause
Handling Procedure
4 If yes, replace the broken optical fiber and plug in the new one. If the alarm
is removed, no handling is needed; if the alarm still persists, ➔ step 2.
4 If not, ➔ Step 2.
2. Detect the Rx optical power of the alarmed C155A card. If the optical power is
normal, check whether the optical fiber is firmly connected to the port. If yes,
replace the alarmed C155A card.
3. Check whether the optical fiber is firmly connected to the port of the optical
transmitting card on the far end equipment. If yes, replace the card on the far
end equipment. If the alarm persists, contact technicians of FiberHome.
Version: D 3-25
AN5116-06B Optical Line Terminal Equipment Alarm and Event Reference
3.6.3 LOF
Alarm Information
Alarm Name Alarm Level Alarm Type
Possible Cause
u The signals transmitted from the far end equipment have no frame structure.
Handling Procedure
4 If the optical power is normal, replace the alarmed C155A card. If the alarm
is removed after replacing, no handling is needed; if the alarm still persists,
➔ Step 3.
2. Check whether the optical fiber between the local end equipment and the far
end equipment and its interface are damaged:
4 If yes, replace the optical fiber and the interface. If the alarm is removed
after replacing, no handling is needed; if the alarm still persists, ➔ Step 3.
4 If not, ➔ Step 3.
4 If the equipment at the far end works abnormally, restore it to the normal
working status. If the alarm is removed after restoration, no handling is
needed; if the alarm still persists, contact FiberHome for technical support.
4 If the equipment at the far end works normally, contact FiberHome for
technical support.
3-26 Version: D
3 Critical Alarms
3.6.4 LFA
Alarm Information
Alarm Name Alarm Level Alarm Type
Possible Cause
Handling Procedure
4 If the optical power is normal, replace the alarmed C155A card. If the alarm
is removed after replacing, no handling is needed; if the alarm still persists,
➔ Step 3.
2. Check whether the optical fiber between the local end equipment and the far
end equipment and its interface are damaged:
4 If yes, replace the optical fiber and the interface. If the alarm is removed
after replacing, no handling is needed; if the alarm still persists, ➔ Step 3.
4 If not, ➔ Step 3.
4 If the equipment at the far end works abnormally, restore it to the normal
working status. If the alarm is removed after restoration, no handling is
needed; if the alarm still persists, contact FiberHome for technical support.
4 If the equipment at the far end works normally, contact FiberHome for
technical support.
Version: D 3-27
AN5116-06B Optical Line Terminal Equipment Alarm and Event Reference
3.6.5 AIS
Alarm Information
Alarm Name Alarm Level Alarm Type
Possible Cause
Handling Procedure
1. Check whether the optical fiber connection is correct via the optical interface
loopback.
4 If yes, ➔ Step 2.
2. Check whether the equipment at the far end connected via the optical fiber
works normally:
4 If the equipment at the far end works abnormally, restore it to the normal
working status. If the alarm is removed after restoration, no handling is
needed; if the alarm still persists, contact FiberHome for technical support.
4 If the equipment at the far end works normally, contact FiberHome for
technical support.
The following introduces the critical alarms might occur in the uplink card and the
handling procedure.
3-28 Version: D
3 Critical Alarms
3.7.1 CARD_NOT_PRESENT
Alarm Information
Alarm Name Alarm Level Alarm Type
u The ANM2000 or the CLI (Command Line Interface) cannot issue any
command to the card located in this slot successfully.
Possible Cause
The uplink card is unplugged from the equipment or the uplink card in the equipment
is faulty.
Handling Procedure
4 If the card is unplugged, check the card and insert it again. If the alarm is
removed, no handling is needed; if the alarm still persists, ➔ Step 2.
2. Check whether the card is faulty and whether the ALARM LED on the card is
ON:
4 If the ALM indicator LED on the card is illuminated, replace the card.
3.7.2 GUP_NO_OPTICS_SIGNAL
Alarm Information
Alarm Name Alarm Level Alarm Type
Version: D 3-29
AN5116-06B Optical Line Terminal Equipment Alarm and Event Reference
Possible Cause
Handling Procedure
1. Check whether the uplink optical interface is connected with the optical fiber:
4 If yes, ➔ Step 2.
2. Check whether the fiber connection of the uplink optical interface is normal:
3. Detect the optical fiber on the uplink port or the optical module with the optical
power meter:
4 If no optical signal is detected, the optical fiber is faulty. Replace the optical
fiber and ➔ Step 5.
1) Click the HU1A card in the Object Tree pane and select Config→Service
Config Management in the menu bar to access the Service Config
Management window.
3) In the Uplink Port Properties tab, click the designated port and cancel the
Port Enable check box to disable the uplink port.
3-30 Version: D
3 Critical Alarms
5) Select the Port Enable check box to enable the uplink port again.
1) Click the HU1A card in the Object Tree pane and select Config→Service
Config Management in the menu bar to access the Service Config
Management window.
3) In the Uplink Port Properties tab, click the designated port and select
Disable in the drop-down list of Port Auto Negotiate to disable the port
automatic negotiation function.
5) Select Enable in the drop-down list of Port Auto Negotiate to enable the
port automatic negotiation function again.
3.7.3 OPTMODULE_NOT_PRESENT
Alarm Information
Alarm Name Alarm Level Alarm Type
Version: D 3-31
AN5116-06B Optical Line Terminal Equipment Alarm and Event Reference
Possible Cause
Handling Procedure
4 If no, ➔ Step 2.
The following introduces the critical alarms might occur in the ONU and the handling
procedure.
3.8.1 LINK_LOSS
Alarm Information
Alarm Name Alarm Level Alarm Type
u If a single ONU reports this alarm, all subscriber services of this ONU may be
interrupted.
u If all ONUs under a PON port of the OLT card report this alarm, all subscriber
services under the PON port are interrupted.
Possible Cause
3-32 Version: D
3 Critical Alarms
4 The optical module of the uplink PON port on the ONU is faulty.
u If all ONU under a PON port of the OLT card report the alarm, probable reasons
are:
4 The optical module of the PON port on the OLT card is faulty.
Handling Procedure
1) Check whether the ONU's PON port is connected with an optical fiber:
2) Check whether the fiber connection for the ONU’s PON port is normal;
Check whether the LOS LED on the ONU is ON.
¡ If no and the LOS indicator LED is On, unplug the optical fiber and
clean it with dedicated fiber wiping paper, and then re-insert it. If the
alarm ends, no handling is needed; if the alarm persists, ➔ Step 3).
3) Detect whether the ONU receives optical signals via the optical power
meter.
¡ If the ONU does not receive any optical signal, the optical fiber's
physical link is faulty. Replace the optical fiber, and if the alarm is
removed after the replacement, no handling is needed; if the alarm
persists, ➔ Step 4).
u If all ONUs under the PON port of the OLT card report this alarm:
Version: D 3-33
AN5116-06B Optical Line Terminal Equipment Alarm and Event Reference
1) Detect the optical module of the PON port on the OLT card with an optical
power meter:
2) Detect the optical fiber (from the PON port to the splitter) with an optical
power meter:
¡ If no optical signal exists, the main fiber link or the splitter is faulty.
Repair the physical link. If the alarm ends, no handling is needed; if
the alarm persists, ➔ Step 3).
3) Detect each optical fiber at the ONU side under the PON port with an
optical power meter:
¡ If no optical signal exists, the branch fiber link or the splitter is faulty.
Repair the physical link. If the alarm ends, no handling is needed; if
the alarm persists, contact FiberHome for technical support.
Alarm Information
Alarm Name Alarm Level Alarm Type
The ONU cannot work normally and cannot provide services for subscribers.
Possible Cause
u The type of the new ONU is not identical to that of the original one when
replacing the ONU.
3-34 Version: D
3 Critical Alarms
u The type of the preconfigured ONU in the ANM2000 is not identical to the
physically connected ONU type, and there are two possibilities:
Handling Procedure
u Replace the ONU. If the type of the new ONU is inconsistent with the original
one, use a correct one.
u The preconfigured ONU type in the ANM2000 is not identical to the physically
connected ONU type.
3.8.3 MGC_DISCONNECTED
Alarm Information
Alarm Name Alarm Level Alarm Type
u If a single ONU's voice service configuration has faults, the NGN voice service
of the ONU subscriber is influenced.
Version: D 3-35
AN5116-06B Optical Line Terminal Equipment Alarm and Event Reference
u If the uplink physical link of the OLT has faults, the NGN voice service of all
ONU subscribers is influenced.
Possible Cause
After the NGN voice services are configured, the communication between the ONU
and the MGC is disconnected; this may be caused by the following events:
4 If a single ONU reports this alarm, the physical connection between the
ONU and the OLT maybe has faults.
4 If all ONU reports this alarm, the OLT's physical connection maybe has
faults.
u The configuration of the NGN voice service is modified and the modification is
wrong.
4 If a single ONU reports this alarm, maybe the ONU’s IP address, VLAN ID
or MGC address configuration is incorrect.
4 If all ONUs report this alarm, maybe the OLT’s local uplink platform data,
VLAN configuration or MGC address configuration is incorrect and the
incorrect configuration has been delivered to all ONUs.
Handling Procedure
1) Check whether the physical connection from the ONU to the OLT is
normal:
3-36 Version: D
3 Critical Alarms
1) Check whether the physical connection from the uplink card to the IP
bearer network equipment is normal:
2) Check whether the configured local VLAN range of the NGN service is
consistent with the planned data. Operate as follows.
a) Click the HSWA card in the Object Tree pane and select Config→
Service Config Management in the menu bar to access the Service
Config Management window.
3) Check whether the MGC address configuration of the NGN service uplink
interface is correct. Operate as follows.
Version: D 3-37
AN5116-06B Optical Line Terminal Equipment Alarm and Event Reference
a) Click the HSWA card in the Object Tree pane and select Config→
Service Config Management in the menu bar to access the Service
Config Management window.
3.8.4 BATTERY_VOLTAGE_TOO_LOW
Alarm Information
Alarm Name Alarm Level Alarm Type
The ONU cannot work normally because the voltage of the battery is overlow.
Possible Cause
Handling Procedure
1. Check whether the alarm is removed after replacing the ONU standby battery:
3-38 Version: D
3 Critical Alarms
3.8.5 LOF
Alarm Information
Alarm Name Alarm Level Alarm Type
The data flow synchronization loss occurs during the delimitation process, which
may cause ONU disconnection.
Possible Cause
The OLT does not receive any frame that is validly delimited from the ONU within
successive 4 frames due to the loss on the optical fiber, bad connection at the
interface or optical module fault.
Handling Procedure
1. Restart the ONU and observe for 5 minutes to see whether the alarm is
removed.
2. View and confirm that the optical fiber is connected with the interface normally.
If optical fiber loss occurs or the interfaces are not firmly connected, replace the
optical fiber or restore the normal connection on the interface.
3. Test whether the ONU's optical module is normal with the PON dedicated
optical power meter and testing optical fiber.
4 If no, replace the optical module. If the alarm ends after the replacement,
no handling is needed; if the alarm still persists, please contact FiberHome
for technical support.
4 If the equipment at the far end works normally, contact FiberHome for
technical support.
Version: D 3-39
AN5116-06B Optical Line Terminal Equipment Alarm and Event Reference
Caution:
Checking whether the optical module is working normally will interrupt the
service.
3.8.6 PLOAM
Alarm Information
Alarm Name Alarm Level Alarm Type
The services of the ONU may be interrupted and the ONU may even be
disconnected.
Possible Cause
After transmitting the PLOAM frame, the OLT has not received the PLOAMu frames
sent from the ONU for successively three times due to the loss on the optical fiber,
bad connection at the interface or optical module fault.
Handling Procedure
1. Restart the ONU and observe for 5 minutes to see whether the alarm is
removed.
2. View and confirm that the optical fiber is connected with the interface normally.
If optical fiber loss occurs or the interfaces are not firmly connected, replace the
optical fiber or restore the normal connection on the interface.
3-40 Version: D
3 Critical Alarms
3. Test whether the ONU's optical module is normal with the PON dedicated
optical power meter and testing optical fiber.
4 If no, replace the optical module. If the alarm ends after the replacement,
no handling is needed; if the alarm still persists, please contact FiberHome
for technical support.
4 If the equipment at the far end works normally, contact FiberHome for
technical support.
Caution:
Checking whether the optical module is working normally will interrupt the
service.
Reference Information
u PLOAM: Used for transmitting the OAM function information between the ONU
and the OLT.
Version: D 3-41
4 Major Alarms
Version: D 4-1
AN5116-06B Optical Line Terminal Equipment Alarm and Event Reference
4.1.1 CONFIG_HAVENOT_SAVED
Alarm Information
Alarm Name Alarm Level Alarm Type
Possible Cause
Handling Procedure
1) Click the active HSWA card in the Object Tree pane and select Config→
Service Config Management in the menu bar to access the Service
Config Management window.
4-2 Version: D
4 Major Alarms
4.1.2 TOO_MANY_TDM
Alarm Information
Alarm Name Alarm Level Alarm Type
Possible Cause
Handling Procedure
1. Check the quantity of the TDM card in the AN5116-06B subrack and unplug the
redundant TDM cards.
4.1.3 CUR_ALARM_NUM_OVER_THRESHOLD
Alarm Information
Alarm Name Alarm Level Alarm Type
Possible Cause
The cumulative number of alarms in the current system exceeds the preconfigured
threshold value.
Version: D 4-3
AN5116-06B Optical Line Terminal Equipment Alarm and Event Reference
Handling Procedure
1. The number of current alarms is less than the threshold value when handling
other alarms in the system.
4.1.4 ALARM_NUM_OVER_THRESHOLD
Alarm Information
Alarm Name Alarm Level Alarm Type
The newly-added system alarms cannot be displayed in the ANM2000 GUI and
subscribers cannot get the latest system status and handle the new alarms.
Possible Cause
The cumulative number of alarms in the current system exceeds the preconfigured
threshold value.
Handling Procedure
1. Analyze system alarms in the alarm report pane and resolve questions put
forward by alarms one by one and delete alarms which have been handled in a
timely manner.
The following introduces major alarms of the EC4B / EC8B / XG2B card.
4-4 Version: D
4 Major Alarms
4.2.1 CARD_TYPE_NOT_IDENTICAL
Alarm Information
Alarm Name Alarm Level Alarm Type
u The ANM2000 or the CLI (Command Line Interface) cannot issue any
command to the card located in this slot successfully.
Possible Cause
The type of the card physically inserted in the equipment is not identical to that
preconfigured in the ANM2000.
Handling Procedure
1. Check the type of the card physically inserted in the equipment to verify
whether the card type matches the configuration in the ANM2000.
4 If the physical card type does not match the configuration in the ANM2000,
replace the card and ➔ Step 2.
2. Modify the card type in the ANM2000 to make it identical to the physical card
type in the equipment:
1) In the ANM2000, right-click the system in the Object Tree pane and select
the Card Config in the shortcut menu.
3. After modifying the card configuration, users should confirm whether the alarm
is removed:
Version: D 4-5
AN5116-06B Optical Line Terminal Equipment Alarm and Event Reference
4.3.1 CARD_TYPE_NOT_IDENTICAL
Alarm Information
Alarm Name Alarm Level Alarm Type
u The ANM2000 or the CLI (Command Line Interface) cannot issue any
command to the card located in this slot successfully.
Possible Cause
The type of the card physically inserted in the equipment is not identical to that
preconfigured in the ANM2000.
Handling Procedure
1. Check the type of the card physically inserted in the equipment to verify
whether the card type matches the configuration in the ANM2000.
4 If the physical card type does not match the configuration in the ANM2000,
replace the card and ➔ Step 2.
2. Modify the card type in the ANM2000 to make it identical to the physical card
type in the equipment:
4-6 Version: D
4 Major Alarms
1) In the ANM2000, right-click the system in the Object Tree pane and select
the Card Config in the shortcut menu.
3. After modifying the card configuration, users should confirm whether the alarm
is removed:
4.4.1 CARD_TYPE_NOT_IDENTICAL
Alarm Information
Alarm Name Alarm Level Alarm Type
u The ANM2000 or the CLI (Command Line Interface) cannot issue any
command to the card located in this slot successfully.
Possible Cause
The type of the card physically inserted in the equipment is not identical to that
preconfigured in the ANM2000.
Version: D 4-7
AN5116-06B Optical Line Terminal Equipment Alarm and Event Reference
Handling Procedure
1. Check the type of the card physically inserted in the equipment to verify
whether the card type matches the configuration in the ANM2000.
4 If the physical card type does not match the configuration in the ANM2000,
replace the card and ➔ Step 2.
2. Modify the card type in the ANM2000 to make it identical to the physical card
type in the equipment:
1) In the ANM2000, right-click the system in the Object Tree pane and select
the Card Config in the shortcut menu.
3. After modifying the card configuration, users should confirm whether the alarm
is removed:
4.4.2 E1_LOS
Alarm Information
Alarm Name Alarm Level Alarm Type
Possible Cause
4-8 Version: D
4 Major Alarms
u The far end equipment connected with the E1 interface has faults.
Handling Procedure
1. Check whether the E1 connection between the OLT and the far end equipment
is normal and perform the E1 loopback test:
1) Click the CE1B card in the Object Tree pane and select Config→Service
Config Management in the menu bar to access the Service Config
Management window.
2) Select Config→E1 Loop in the Menu Tree pane to open the E1 Loop tab.
4) Click Create on Device button to test the E1 connection between the OLT
and the far end equipment.
¡ If yes, ➔ Step 2.
2. Check whether the equipment at the far end connected via the E1 transmission
line works normally:
4 If the equipment at the far end works abnormally, restore it to the normal
working status. If the alarm is removed after restoration, no handling is
needed; if the alarm still persists, contact FiberHome for technical support.
4 If the equipment at the far end works normally, contact FiberHome for
technical support.
4.4.3 E1 LFA
Alarm Information
Alarm Name Alarm Level Alarm Type
Version: D 4-9
AN5116-06B Optical Line Terminal Equipment Alarm and Event Reference
Possible Cause
u The far end equipment connected with the E1 interface has faults.
Handling Procedure
1. Check whether the E1 connection between the OLT and the far end equipment
is normal and perform the E1 loopback test:
1) Click the CE1B card in the Object Tree pane and select Config→Service
Config Management in the menu bar to access the Service Config
Management window.
2) Click the ONU under the interface card in the Remote Object tab in the
Object Tree pane, and select Config→E1 Loop in the Menu Tree pane to
open the E1 Loop tab.
4) Click Create on Device button to test the E1 connection between the OLT
and the far end equipment.
¡ If yes, ➔ Step 2.
2. Check whether the equipment at the far end connected via the E1 transmission
line works normally:
4 If the equipment works abnormally, restore the far end equipment to the
normal working status. If the alarm is removed after restoration, no
handling is needed; if the alarm still persists, ➔ Step 3.
4-10 Version: D
4 Major Alarms
4.4.4 E1_AIS
Alarm Information
Alarm Name Alarm Level Alarm Type
Possible Cause
u The far end equipment connected with the E1 interface has faults.
Handling Procedure
1. Check whether the E1 connection between the OLT and the far end equipment
is normal and perform the E1 loopback test:
1) Click the CE1B card in the Object Tree pane and select Config→Service
Config Management in the menu bar to access the Service Config
Management window.
2) Select Config→E1 Loop in the Menu Tree pane to open the E1 Loop tab.
4) Click Create on Device button to test the E1 connection between the OLT
and the far end equipment.
¡ If yes, ➔ Step 2.
2. Check whether the equipment at the far end connected via the E1 transmission
line works normally:
4 If the equipment at the far end works abnormally, restore it to the normal
working status. If the alarm is removed after restoration, no handling is
needed; if the alarm still persists, contact FiberHome for technical support.
Version: D 4-11
AN5116-06B Optical Line Terminal Equipment Alarm and Event Reference
4 If the equipment at the far end works normally, contact FiberHome for
technical support.
4.5.1 CARD_TYPE_NOT_IDENTICAL
Alarm Information
Alarm Name Alarm Level Alarm Type
u The ANM2000 or the CLI (Command Line Interface) cannot issue any
command to the card located in this slot successfully.
Possible Cause
The type of the card physically inserted in the equipment is not identical to that
preconfigured in the ANM2000.
Handling Procedure
1. Check the type of the card physically inserted in the equipment to verify
whether the card type matches the configuration in the ANM2000.
4 If the physical card type does not match the configuration in the ANM2000,
replace the card and ➔ Step 2.
2. Modify the card type in the ANM2000 to make it identical to the physical card
type in the equipment:
1) In the ANM2000, right-click the system in the Object Tree pane and select
the Card Config in the shortcut menu.
4-12 Version: D
4 Major Alarms
3. After modifying the card configuration, users should confirm whether the alarm
is removed:
4.6.1 CARD_TYPE_NOT_IDENTICAL
Alarm Information
Alarm Name Alarm Level Alarm Type
u The ANM2000 or the CLI (Command Line Interface) cannot issue any
command to the card located in this slot successfully.
Possible Cause
The type of the card physically inserted in the equipment is not identical to that
preconfigured in the ANM2000.
Handling Procedure
1. Check the type of the card physically inserted in the equipment to verify
whether the card type matches the configuration in the ANM2000.
Version: D 4-13
AN5116-06B Optical Line Terminal Equipment Alarm and Event Reference
4 If the physical card type does not match the configuration in the ANM2000,
replace the card and ➔ Step 2.
2. Modify the card type in the ANM2000 to make it identical to the physical card
type in the equipment:
1) In the ANM2000, right-click the system in the Object Tree pane and select
the Card Config in the shortcut menu.
3. After modifying the card configuration, users should confirm whether the alarm
is removed:
4.6.2 UP_SPEED_OVER_THRESHOLD
Alarm Information
Alarm Name Alarm Level Alarm Type
Possible Cause
u The real-time uplink rate of the uplink card port exceeds the configured alarm
threshold.
4-14 Version: D
4 Major Alarms
Handling Procedure
1. Click the system in the Object Tree pane and select Config→Service Config
Management in the menu bar to access the Service Config Management
window.
3. Click the used template to check whether the alarm reporting threshold whose
Alarm Code is UP_SPEED_OVER_THRESHOLD needs to be modified.
4 If yes, ➔ Step 4.
4 If no, ➔ Step 6.
6. If the traffic of the uplink card port exceeds the expectation, it is recommended
to configure the LACP to perform traffic sharing for the uplink port. For the
detailed operations, refer to EPON Configuration Guide or GPON Configuration
Guide.
4.6.3 DOWN_SPEED_OVER_THRESHOLD
Alarm Information
Alarm Name Alarm Level Alarm Type
Version: D 4-15
AN5116-06B Optical Line Terminal Equipment Alarm and Event Reference
Possible Cause
u The real-time downlink rate of the uplink card port exceeds the configured
alarm threshold.
Handling Procedure
1. Click the system in the Object Tree pane and select Config→Service Config
Management in the menu bar to access the Service Config Management
window.
3. Click the used template to check whether the alarm reporting threshold whose
Alarm Code is DOWN_SPEED_OVER_THRESHOLD needs to be modified.
4 If yes, ➔ Step 4.
4 If no, ➔ Step 6.
6. If the traffic of the uplink card port exceeds the expectation, it is recommended
to configure the LACP to perform traffic sharing for the uplink port. For the
detailed operations, refer to EPON Configuration Guide or GPON Configuration
Guide.
4-16 Version: D
4 Major Alarms
4.7.1 CARD_TYPE_NOT_IDENTICAL
Alarm Information
Alarm Name Alarm Level Alarm Type
u The ANM2000 or the CLI (Command Line Interface) cannot issue any
command to the card located in this slot successfully.
u All services loaded on this card are interrupted; and the card cannot provide
voice services.
Possible Cause
The type of the card physically inserted in the equipment is not identical to that
preconfigured in the ANM2000.
Handling Procedure
1. Check the type of the card physically inserted in the equipment to verify
whether the card type matches the configuration in the ANM2000.
4 If the physical card type does not match the configuration in the ANM2000,
replace the card and ➔ Step 2.
2. Modify the card type in the ANM2000 to make it identical to the physical card
type in the equipment:
1) In the ANM2000, right-click the system in the Object Tree pane and select
the Card Config in the shortcut menu.
Version: D 4-17
AN5116-06B Optical Line Terminal Equipment Alarm and Event Reference
3. After modifying the card configuration, users should confirm whether the alarm
is removed:
4.8.1 CPU_VER_LOW
Alarm Information
Alarm Name Alarm Level Alarm Type
Possible Cause
The ONU’s chip software version is an old version, which is not compatible with the
service configuration of the AN5116-06B system.
Handling Procedure
1) Start the FTP server and make configuration. Copy the corollary CPU
version to the corresponding folder.
2) Log into the ANM2000. Click the active HSWA card in the Object Tree
pane and select Config→Service Config Management in the menu bar
to access the Service Config Management window.
4-18 Version: D
4 Major Alarms
4) Select the type of ONU to be upgraded and click OK to open the Batch
Upgrade ONU tab in the ANM2000 GUI. Configure the parameters
according to the actual situation. After setting, click Execute in the
Administrative Tools pane to upgrade ONUs in a batch manner.
2. After the upgrade is successful, check whether the new functions configured on
the ONU are available.
4.8.2 E1_LOS
Alarm Information
Alarm Name Alarm Level Alarm Type
Note:
Possible Cause
u The far end equipment connected with the E1 interface has faults.
Handling Procedure
1. Check whether the E1 connection between the ONU and the far end equipment
is normal and perform the E1 loopback test:
1) Click the PON interface connected to the ONU in the Object Tree pane
and select Config→Service Config Management in the menu bar to
access the Service Config Management window.
Version: D 4-19
AN5116-06B Optical Line Terminal Equipment Alarm and Event Reference
2) Click the ONU under the interface card in the Remote Object tab in the
Object Tree pane, and select Config→E1 Port Loop in the Menu Tree
pane to open the E1 Port Loop tab.
4) Click Create on Device button to test the E1 connection between the ONU
and the far end equipment.
2. Check whether the equipment at the far end connected via the E1 transmission
line works normally:
4 If the equipment at the far end works abnormally, restore it to the normal
working status. If the alarm is removed after restoration, no handling is
needed; if the alarm still persists, contact FiberHome for technical support.
4 If the equipment at the far end works normally, contact FiberHome for
technical support.
4.8.3 E1 LFA
Alarm Information
Alarm Name Alarm Level Alarm Type
Note:
Possible Cause
4-20 Version: D
4 Major Alarms
u The far end equipment connected with the E1 interface has faults.
Handling Procedure
1. Check whether the E1 connection between the ONU and the far end equipment
is normal and perform the E1 loopback test:
1) Click the PON interface connected to the ONU in the Object Tree pane
and select Config→Service Config Management in the menu bar to
access the Service Config Management window.
2) Click the ONU under the interface card in the Remote Object tab in the
Object Tree pane, and select Config→E1 Port Loop in the Menu Tree
pane to open the E1 Port Loop tab.
4) Click Create on Device button to test the E1 connection between the ONU
and the far end equipment.
2. Check whether the equipment at the far end connected via the E1 transmission
line works normally:
4 If the equipment at the far end works abnormally, restore it to the normal
working status. If the alarm is removed after restoration, no handling is
needed; if the alarm still persists, contact FiberHome for technical support.
4 If the equipment at the far end works normally, contact FiberHome for
technical support.
4.8.4 E1_AIS
Alarm Information
Alarm Name Alarm Level Alarm Type
Version: D 4-21
AN5116-06B Optical Line Terminal Equipment Alarm and Event Reference
Note:
Possible Cause
u The far end equipment connected with the E1 interface has faults.
Handling Procedure
1. Check whether the local end equipment works normally and perform the E1
loopback test:
1) Click the PON interface connected to the ONU in the Object Tree pane
and select Config→Service Config Management in the menu bar to
access the Service Config Management window.
2) Click the ONU under the interface card in the Remote Object tab in the
Object Tree pane, and select Config→E1 Port Loop in the Menu Tree
pane to open the E1 Port Loop tab.
¡ If the alarm still persists, the local end equipment is faulty. If the alarm
ends after replacing the ONU, no other handling is needed. If the
alarm persists after the replacement, ➔ Step 2.
2. Check whether the equipment at the far end connected via the E1 transmission
line works normally:
4-22 Version: D
4 Major Alarms
4 If the equipment at the far end works abnormally, repair the far end
equipment. If the alarm is removed after restoration, no handling is
needed; if the alarm still persists, contact FiberHome for technical support.
4 If the equipment at the far end works normally, contact FiberHome for
technical support.
4.8.5 DC_LOW_VOLTAGE_ALARM
Alarm Information
Alarm Name Alarm Level Alarm Type
When the DC voltage is too low, the ONU cannot work normally or provide services
for users.
Possible Cause
Handling Procedure
Version: D 4-23
AN5116-06B Optical Line Terminal Equipment Alarm and Event Reference
4.8.6 AC_FAIL
Alarm Information
Alarm Name Alarm Level Alarm Type
The ONU cannot work normally and cannot provide services for subscribers.
Possible Cause
Handling Procedure
Alarm Information
Alarm Name Alarm Level Alarm Type
The ONU cannot work normally and cannot provide services for subscribers.
4-24 Version: D
4 Major Alarms
Possible Cause
Handling Procedure
1. Check whether the connection between the ONU and the storage battery is
normal.
4 If yes, ➔ Step 2.
2. Replace the ONU battery and check whether the alarm is removed.
4.8.8 E1_TIMING_UNLOCK
Alarm Information
Alarm Name Alarm Level Alarm Type
Note:
Possible Cause
u The far end equipment connected with the E1 interface has faults.
Version: D 4-25
AN5116-06B Optical Line Terminal Equipment Alarm and Event Reference
Handling Procedure
2. Check whether the equipment at the far end connected via the E1 transmission
line works normally:
4 If the equipment at the far end works abnormally, restore it to the normal
working status. If the alarm is removed after restoration, no handling is
needed; if the alarm still persists, contact FiberHome for technical support.
4 If the equipment at the far end works normally, contact FiberHome for
technical support.
4.8.9 RX_POWER_HIGH_ALARM
Alarm Information
Alarm Name Alarm Level Alarm Type
The ONU service is influenced or even all services are disconnected because the
optical module cannot work well.
Possible Cause
u The setting of the alarm threshold value of the ONU Rx optical power is
unreasonable.
4-26 Version: D
4 Major Alarms
Handling Procedure
Caution:
Checking whether the optical module is working normally will interrupt the
service.
1. Observe the alarm for 5 minutes to check whether the alarm is removed
automatically.
2. Test the Rx optical power on the ONU side with the PON dedicated optical
power meter and testing optical fiber to check whether the optical power is
within the normal range:
4 If the optical power is too high, add optical attenuators in the optical path or
replace the optical module of the PON port on the OLT side.
3. Check whether the setting of maximum threshold value for the Rx optical power
is reasonable:
1) Click the system in the Object Tree pane and select Config→Service
Config Management in the menu bar to access the Service Config
Management window.
3) Check whether the alarm threshold value in the Alarm Code is valid.
Version: D 4-27
AN5116-06B Optical Line Terminal Equipment Alarm and Event Reference
4.8.10 RX_POWER_LOW_ALARM
Alarm Information
Alarm Name Alarm Level Alarm Type
The ONU service is influenced or even all services are disconnected because the
optical module cannot work well.
Possible Cause
u The setting of the alarm threshold value of the ONU Rx optical power is
unreasonable.
Handling Procedure
Caution:
Checking whether the optical module is working normally will interrupt the
service.
1. Observe the alarm for 5 minutes to check whether the alarm is removed
automatically.
2. Test the Rx optical power on the ONU side with the PON dedicated optical
power meter and testing optical fiber to check whether the optical power is too
low:
4-28 Version: D
4 Major Alarms
4 If the optical power is over-low, check and repair the optical fiber line or
replace the PON port optical module on OLT side. If the alarm ends, no
handling is needed; if the alarm still persists, please contact FiberHome for
technical support.
3. Check whether the setting of minimum threshold value for the Rx optical power
is reasonable:
1) Click the system in the Object Tree pane and select Config→Service
Config Management in the menu bar to access the Service Config
Management window.
3) Check whether the alarm threshold value in the Alarm Code is valid.
4.8.11 TX_POWER_HIGH_ALARM
Alarm Information
Alarm Name Alarm Level Alarm Type
The ONU service is influenced or even all services are disconnected because the
optical module cannot work well.
Version: D 4-29
AN5116-06B Optical Line Terminal Equipment Alarm and Event Reference
Possible Cause
u The setting of the alarm threshold value of the ONU Tx optical power is
unreasonable.
Handling Procedure
Caution:
Checking whether the optical module is working normally will interrupt the
service.
1. Observe the alarm for 5 minutes to check whether the alarm is removed
automatically.
2. Test the Tx optical power of the ONU optical module with the PON dedicated
optical power meter and testing optical fiber to check whether the optical power
is too high:
4 If the optical power is over-high, replace the optical module. If the alarm
ends after the replacement, no handling is needed; if the alarm still persists,
please contact FiberHome for technical support.
3. Check whether the setting of maximum threshold value for the Tx optical power
is reasonable:
1) Click the system in the Object Tree pane and select Config→Service
Config Management in the menu bar to access the Service Config
Management window.
3) Check whether the alarm threshold value in the Alarm Code is valid.
4-30 Version: D
4 Major Alarms
4.8.12 TX_POWER_LOW_ALARM
Alarm Information
Alarm Name Alarm Level Alarm Type
The ONU service is influenced or even all services are disconnected because the
optical module cannot work well.
Possible Cause
u The setting of the alarm threshold value of the ONU Tx optical power is
unreasonable.
Handling Procedure
Caution:
Checking whether the optical module is working normally will interrupt the
service.
1. Observe the alarm for 5 minutes to check whether the alarm is removed
automatically.
Version: D 4-31
AN5116-06B Optical Line Terminal Equipment Alarm and Event Reference
2. Test the Tx optical power of the ONU optical module with the PON dedicated
optical power meter and testing optical fiber to check whether the optical power
is too low:
4 If the optical power is over-low, replace the optical module. If the alarm
ends after the replacement, no handling is needed; if the alarm still persists,
please contact FiberHome for technical support.
3. Check whether the setting of minimum threshold value for the Tx optical power
is reasonable:
1) Click the system in the Object Tree pane and select Config→Service
Config Management in the menu bar to access the Service Config
Management window.
3) Check whether the alarm threshold value in the Alarm Code is valid.
4.8.13 BIAS_HIGH_ALARM
Alarm Information
Alarm Name Alarm Level Alarm Type
4-32 Version: D
4 Major Alarms
The ONU service is influenced or even all services are disconnected because the
optical module cannot work well.
Possible Cause
u The setting of the alarm threshold value of the ONU optical module's bias
current is unreasonable.
Handling Procedure
Caution:
Checking whether the optical module is working normally will interrupt the
service.
1. Observe the alarm for 5 minutes to check whether the alarm is removed
automatically.
2. Test the Rx optical power on the ONU side and the Tx optical power of the
ONU optical module with the PON dedicated optical power meter and testing
optical fiber to check whether the optical power is within the normal range:
4 If the optical power exceeds the normal range, replace the optical module.
If the alarm ends after the replacement, no handling is needed; if the alarm
still persists, please contact FiberHome for technical support.
3. Check whether the setting of maximum threshold value of the ONU optical
module's bias current is reasonable:
1) Click the system in the Object Tree pane and select Config→Service
Config Management in the menu bar to access the Service Config
Management window.
Version: D 4-33
AN5116-06B Optical Line Terminal Equipment Alarm and Event Reference
3) Check whether the alarm threshold value in the Alarm Code is valid.
4.8.14 BIAS_LOW_ALARM
Alarm Information
Alarm Name Alarm Level Alarm Type
The ONU service is influenced or even all services are disconnected because the
optical module cannot work well.
Possible Cause
u The setting of the alarm threshold value of the ONU optical module's bias
current is unreasonable.
Handling Procedure
Caution:
Checking whether the optical module is working normally will interrupt the
service.
4-34 Version: D
4 Major Alarms
1. Observe the alarm for 5 minutes to check whether the alarm is removed
automatically.
2. Test the Rx optical power on the ONU side and the Tx optical power of the
ONU optical module with the PON dedicated optical power meter and testing
optical fiber to check whether the optical power is within the normal range:
4 If the optical power exceeds the normal range, replace the optical module.
If the alarm ends after the replacement, no handling is needed; if the alarm
still persists, please contact FiberHome for technical support.
3. Check whether the setting of minimum threshold value of the ONU optical
module's bias current is reasonable:
1) Click the system in the Object Tree pane and select Config→Service
Config Management in the menu bar to access the Service Config
Management window.
3) Check whether the alarm threshold value in the Bias Current Overlow is
valid.
Version: D 4-35
AN5116-06B Optical Line Terminal Equipment Alarm and Event Reference
4.8.15 VCC_HIGH_ALARM
Alarm Information
Alarm Name Alarm Level Alarm Type
The ONU service is influenced or even all services are disconnected because the
optical module cannot work well.
Possible Cause
u The setting of the alarm threshold value of the ONU optical module's voltage is
unreasonable.
Handling Procedure
Caution:
Checking whether the optical module is working normally will interrupt the
service.
1. Observe the alarm for 5 minutes to check whether the alarm is removed
automatically.
2. Test the Rx optical power on the ONU side and the Tx optical power of the
ONU optical module with the PON dedicated optical power meter and testing
optical fiber to check whether the optical power is within the normal range:
4 If the optical power exceeds the normal range, replace the optical module.
If the alarm ends after the replacement, no handling is needed; if the alarm
still persists, please contact FiberHome for technical support.
4-36 Version: D
4 Major Alarms
3. Check whether the setting of maximum threshold value of the ONU optical
module's voltage is reasonable:
1) Click the system in the Object Tree pane and select Config→Service
Config Management in the menu bar to access the Service Config
Management window.
3) Check whether the alarm threshold value in the Bias Voltage Overhigh is
valid.
4.8.16 VCC_LOW_ALARM
Alarm Information
Alarm Name Alarm Level Alarm Type
The ONU service is influenced or even all services are disconnected because the
optical module cannot work well.
Possible Cause
u The setting of the alarm threshold value of the ONU optical module's voltage is
unreasonable.
Version: D 4-37
AN5116-06B Optical Line Terminal Equipment Alarm and Event Reference
Handling Procedure
Caution:
Checking whether the optical module is working normally will interrupt the
service.
1. Observe the alarm for 5 minutes to check whether the alarm is removed
automatically.
2. Test the Rx optical power on the ONU side and the Tx optical power of the
ONU optical module with the PON dedicated optical power meter and testing
optical fiber to check whether the optical power is within the normal range:
4 If the optical power exceeds the normal range, replace the optical module.
If the alarm ends after the replacement, no handling is needed; if the alarm
still persists, please contact FiberHome for technical support.
3. Check whether the setting of minimum threshold value of the ONU optical
module's voltage is reasonable:
1) Click the system in the Object Tree pane and select Config→Service
Config Management in the menu bar to access the Service Config
Management window.
3) Check whether the alarm threshold value in the Bias Voltage Overlow is
valid.
4-38 Version: D
4 Major Alarms
4.8.17 INNER_TEMP_HIGH
Alarm Information
Alarm Name Alarm Level Alarm Type
The ONU service is influenced or even all services are disconnected because the
optical module cannot work well.
Possible Cause
Handling Procedure
4 If the fan has faults or rotates too slowly, replace the fan.
4 If the ambient temperature is too high, improve the ventilation and take
cooling measures.
Version: D 4-39
AN5116-06B Optical Line Terminal Equipment Alarm and Event Reference
4.8.18 INNER_TEMP_LOW
Alarm Information
Alarm Name Alarm Level Alarm Type
The ONU service is influenced or even all services are disconnected because the
optical module cannot work well.
Possible Cause
Handling Procedure
4.8.19 REMOTE_ONU_UNI_LOOPBACK
Alarm Information
Alarm Name Alarm Level Alarm Type
The subscriber equipment connected to the port fails to use the service.
Possible Cause
The port which the ONU connects with the subscriber equipment is in the loopback
status.
4-40 Version: D
4 Major Alarms
Handling Procedure
1. Check whether the loop exists in the user equipment's connection line.
4 If no, ➔ Step 2.
2. Click the PON interface connected to the ONU in the Object Tree pane and
select Config→Service Config Management in the menu bar to access the
Service Config Management window.
3. Click the ONU under the interface card in the Remote Object tab in the Object
Tree pane, and select Config→Port Loop Detect in the Menu Tree pane.
Select Disable in the UNI Loop Detect Management drop-down list of the port
and disable the port loopback.
4. Click Create on Device to write the configuration to the equipment. If the alarm
ends, no handling is needed; if the alarm still persists, please contact
FiberHome for technical support.
4.8.20 POWER_FAIL_ALARM
Alarm Information
Alarm Name Alarm Level Alarm Type
The ONU cannot work normally and cannot provide services for subscribers.
Possible Cause
Handling Procedure
Version: D 4-41
AN5116-06B Optical Line Terminal Equipment Alarm and Event Reference
¡ The ONU power supply is shut off and make sure the power supply
switch is ON.
¡ If the external power supply and the power cable connection are
normal, and the ONU power supply switch is ON, please contact
FiberHome for technical support.
4-42 Version: D
5 Minor Alarms
Version: D 5-1
AN5116-06B Optical Line Terminal Equipment Alarm and Event Reference
5.1.1 UP_CRC_ERROR_THRESHOLD /
DOWN_CRC_ERROR_THRESHOLD
Alarm Information
UP_CRC_ERROR_
THRESHOLD / DOWN_ Minor alarms Service quality alarm
CRC_ERROR_THRESHOLD
The service provided by the system is influenced and the uplink card's uplink /
downlink data has packet loss.
Possible Cause
u The poor network quality causes the uplink / downlink CRC error to reach the
threshold value.
Handling Procedure
1. Check the network quality to see whether the network cable, optical fiber and
optical module are aging.
4 If yes: replace the aging network cable, optical fiber and optical module. If
the alarm ends, no handling is needed; if the alarm still persists, ➔ Step 2.
4 If no, ➔ Step 2.
2. Check the optical fiber connector and bend angle. The bend radius of the
optical cable should be more than 38mm. Clean the optical fiber connector with
fiber wiping paper.
4 If the alarm is removed after cleaning the optical fiber connector and
adjusting the bend angle, no other handling is needed.
5-2 Version: D
5 Minor Alarms
4 If the alarm persists after cleaning the optical fiber connector and adjusting
the bend angle, ➔ Step 3.
4 If yes, ➔ Step 4.
1) Click the uplink card in the Object Tree pane and select Config→Service
Config Management in the menu bar to access the Service Config
Management window.
3) Input the suitable threshold value in the Crc Statistics Threshold column.
Reference Information
CRC (Cyclical Redundancy Check): A method of checking for errors in data that has
been transmitted on a communications link. A sending device applies a 16- or 32-bit
polynomial to a block of data that is to be transmitted and appends the resulting
cyclic redundancy code (CRC) to the block. The receiving end applies the same
polynomial to the data and compares its result with the result appended by the
sender. If they agree, the data has been received successfully. If not, the sender can
be notified to resend the block of data.
5.1.2 UNDERSIZEFRAME_THRESHOLD
Alarm Information
Alarm Name Alarm Level Alarm Type
Version: D 5-3
AN5116-06B Optical Line Terminal Equipment Alarm and Event Reference
The system bandwidth is occupied by the undersized packets, so the quality of the
services provided is influenced.
Possible Cause
The quantity of the undersized packets currently received by the system exceeds
the configured threshold.
Handling Procedure
1. Check whether the equipment at the far end connected with the uplink card
works normally:
4 If the equipment at the far end works abnormally, restore it to the normal
working status. If the alarm is removed after restoration, no handling is
needed; if the alarm still persists, contact FiberHome for technical support.
4 If the equipment at the far end works normally, contact FiberHome for
technical support.
Reference Information
Undersized packet: The frame that is smaller than 64 bytes. The undersized
packets are considered as the fragments generated in the signal collision, and
should be discarded.
5.2.1 UP_CRC_ERROR_THRESHOLD /
DOWN_CRC_ERROR_THRESHOLD
Alarm Information
UP_CRC_ERROR_
THRESHOLD / DOWN_ Minor alarms Service quality alarm
CRC_ERROR_THRESHOLD
5-4 Version: D
5 Minor Alarms
The service provided by the system is influenced and the packet loss occurs in the
uplink data of the ONU.
Possible Cause
u The poor network quality causes the uplink/downlink CRC error to reach the
threshold value.
Handling Procedure
1. Check whether the network cable of the LAN port is connected normally:
4 If no, replace the network cable. If the alarm ends after the replacement,
no handling is needed; if the alarm still persists, ➔ Step 2.
4 If yes, ➔ Step 2.
4 If yes, ➔ Step 3.
1) Click the PON interface connected to the ONU in the Object Tree pane
and select Config→Service Config Management in the menu bar to
access the Service Config Management window.
2) Click the ONU under the interface card in the Remote Object tab in the
Object Tree pane, and select Config→LAN Port PM Threshold in the
Menu Tree pane to open the LAN Port PM Threshold tab.
Up/down CRC_threshold 0
Version: D 5-5
AN5116-06B Optical Line Terminal Equipment Alarm and Event Reference
5.2.2 UP_BIP8_OVER_THRESHOLD
Alarm Information
Alarm Name Alarm Level Alarm Type
The services of the ONU may be interrupted and the ONU may even be
disconnected.
Possible Cause
The quantity of the BIP8s (load bit errors) within the uplink data received by the OLT
exceeds the configured threshold due to the loss on the optical fiber, bad connection
at the interface and optical module fault.
Handling Procedure
1. Restart the ONU and observe for 5 minutes to see whether the alarm is
removed.
2. View and confirm that the optical fiber is connected with the interface normally.
If optical fiber loss occurs or the interfaces are not firmly connected, replace the
optical fiber or restore the normal connection on the interface.
3. Test whether the ONU's optical module is normal with the PON dedicated
optical power meter and testing optical fiber.
4 If no, replace the optical module. If the alarm ends after the replacement,
no handling is needed; if the alarm still persists, please contact FiberHome
for technical support.
4 If the equipment at the far end works normally, contact FiberHome for
technical support.
5-6 Version: D
5 Minor Alarms
Caution:
Checking whether the optical module is working normally will interrupt the
service.
5.2.3 DOWN_BIP8_OVER_THRESHOLD
Alarm Information
Alarm Name Alarm Level Alarm Type
The services of the ONU may be interrupted and the ONU may even be
disconnected.
Possible Cause
The quantity of the BIP8s (load bit errors) within the uplink data received by the OLT
exceeds the configured threshold due to the loss on the optical fiber, bad connection
at the interface and optical module fault.
Handling Procedure
1. Restart the ONU and observe for 5 minutes to see whether the alarm is
removed.
2. View and confirm that the optical fiber is connected with the interface normally.
If optical fiber loss occurs or the interfaces are not firmly connected, replace the
optical fiber or restore the normal connection on the interface.
Version: D 5-7
AN5116-06B Optical Line Terminal Equipment Alarm and Event Reference
3. Test whether the ONU's optical module is normal with the PON dedicated
optical power meter and testing optical fiber.
4 If no, replace the optical module. If the alarm ends after the replacement,
no handling is needed; if the alarm still persists, please contact FiberHome
for technical support.
4 If the equipment at the far end works normally, contact FiberHome for
technical support.
Caution:
Checking whether the optical module is working normally will interrupt the
service.
5-8 Version: D
6 Prompt Alarms
Version: D 6-1
AN5116-06B Optical Line Terminal Equipment Alarm and Event Reference
6.1.1 CPU_USAGE_OVER_THRESHOLD
Alarm Information
Alarm Name Alarm Level Alarm Type
The CPU running speed of this card may become lower, and the system may
collapse.
Possible Cause
u The programs running in the card are too many in quantity or too large in size.
Handling Procedure
1) Click the HSWA card in the Object Tree pane and select Config→Service
Config Management in the menu bar to access the Service Config
Management window.
2. Observe for a period of time to check whether the CPU utilization ratio
decreases.
6-2 Version: D
6 Prompt Alarms
4 If yes, ➔ Step 4.
1) Click the HSWA card in the Object Tree pane and select Config→Service
Config Management in the menu bar to access the Service Config
Management window.
4) Input the appropriate CPU utilization threshold value in the CPU Usage
Threshold (%) column.
6.1.2 MEM_USAGE_OVER_THRESHOLD
Alarm Information
Alarm Name Alarm Level Alarm Type
The CPU running speed of this card may become lower, and the system may
collapse.
Possible Cause
u The programs running in the card are too many in quantity or some programs
occupy too much memory space.
Version: D 6-3
AN5116-06B Optical Line Terminal Equipment Alarm and Event Reference
Handling Procedure
1) Click the HSWA card in the Object Tree pane and select Config→Service
Config Management in the menu bar to access the Service Config
Management window.
2. Observe for a period of time to check whether the memory utilization ratio
decreases.
4 If yes, ➔ Step 4.
1) Click the HSWA card in the Object Tree pane and select Config→Service
Config Management in the menu bar to access the Service Config
Management window.
4) Input the appropriate memory utilization threshold value in the CPU Usage
Threshold column.
6-4 Version: D
6 Prompt Alarms
Alarm Information
Alarm Name Alarm Level Alarm Type
The used License resource reaches the pre-set threshold. If users continue to use it,
the license resource will be insufficient and the functions controlled by License
cannot be used.
Possible Cause
Handling Procedure
1) Click the HSWA card in the Object Tree pane and select Config→Service
Config Management in the menu bar to access the Service Config
Management window.
¡ If no, ➔ Step 2.
1) Click the HSWA card in the Object Tree pane and select Config→Service
Config Management in the menu bar to access the Service Config
Management window.
Version: D 6-5
AN5116-06B Optical Line Terminal Equipment Alarm and Event Reference
a) If yes, ➔ Step 3.
1) Click the HSWA card in the Object Tree pane and select Config→Service
Config Management in the menu bar to access the Service Config
Management window.
2) Select License→Esn Query in the Menu Tree to open the Esn Query
tab.
6) Set the parameters and click Create on Device to download the License
to the equipment.
The following introduces prompt alarms of the EC4B / EC8B / XG2B card.
6.2.1 ILEGAL_ONU_REGISTE
Alarm Information
Alarm Name Alarm Level Alarm Type
6-6 Version: D
6 Prompt Alarms
Possible Cause
u In the authentication based on the logical ID white list (without password), the
logical ID of an ONU to be registered does not match the item in the logical ID
white list.
Handling Procedure
a) Click the HSWA card in the Object Tree pane and select Config→
Service Config Management in the menu bar to access the Service
Config Management window.
b) Enter 1 in the Please Input the Row for Add dialog box that appears
and click OK to create one whitelist. Enter the corresponding physical
address and select slot number, PON port and ONU type.
• If the alarm still persists after the physical ID is added, ➔ Step 3).
Version: D 6-7
AN5116-06B Optical Line Terminal Equipment Alarm and Event Reference
a) Click the HSWA card in the Object Tree pane and select Config→
Service Config Management in the menu bar to access the Service
Config Management window.
2) Add the ONU's logical SN number in the logical SN white list setting.
a) Click the HSWA card in the Object Tree pane and select Config→
Service Config Management in the menu bar to access the Service
Config Management window.
d) Input the corresponding SN number and select the slot number, PON
port and ONU type.
6-8 Version: D
6 Prompt Alarms
• If the alarm still persists after the logical ID is added, ➔ Step 3).
6.2.2 ONU_AUTO_CONFIG_FAILED
Alarm Information
Alarm Name Alarm Level Alarm Type
The ONU cannot be authorized and it cannot provide services for subscribers.
Possible Cause
u ONUs with the same MAC address of the PON port have been registered.
Version: D 6-9
AN5116-06B Optical Line Terminal Equipment Alarm and Event Reference
u The PON port accessed 64 ONUs and the 64 authorization numbers have been
assigned. If the 65th ONU is accessed to the PON port, the OLT cannot assign
the newly-added ONU with an authorization number.
u If the number of ONUs accessed to a PON port is less than 64 but the sum of
bandwidth assigned to these ONUs is greater than the total bandwidth of the
PON port, then the OLT cannot assign the newly added ONU with an
authorization number.
Handling Procedure
4 If no, ➔ Step 2.
2. Check the PON port’s total bandwidth and subscriber service bandwidth
assignment:
4 If the service bandwidth is larger than the PON port’s total bandwidth,
adjust the service bandwidth and ➔ Step 3.
3. Authorize the ONU again manually under this OLT. Refer to EPON
Configuration Guide for more details.
6.2.3 CPU_USAGE_OVER_THRESHOLD
Alarm Information
Alarm Name Alarm Level Alarm Type
The CPU running speed of this card may become lower, and the system may
collapse because of the excessive utilization.
Possible Cause
6-10 Version: D
6 Prompt Alarms
u The programs running in the card are too many in quantity or too large in size.
Handling Procedure
1) Click the designated card in the Object Tree pane and select Config→
Service Config Management in the menu bar to access the Service
Config Management window.
2. Observe for a period of time to check whether the CPU utilization ratio
decreases.
4 If yes, ➔ Step 4.
4 If no, ➔ Step 5.
1) Click the active HSWA card in the Object Tree pane and select Config→
Service Config Management in the menu bar to access the Service
Config Management window.
4) Input the appropriate CPU utilization threshold value in the CPU Usage
Threshold (%) column.
Version: D 6-11
AN5116-06B Optical Line Terminal Equipment Alarm and Event Reference
4 If yes, ➔ Step 6.
1) Click the designated card in the Object Tree pane and select Config→
Service Config Management in the menu bar to access the Service
Config Management window.
2) Select Config→PM Class Threshold in the Menu Tree pane to open the
IPM Class Threshold tab.
6.2.4 MEM_USAGE_OVER_THRESHOLD
Alarm Information
Alarm Name Alarm Level Alarm Type
The CPU running speed of this card may become lower, and the system may
collapse because of the excessive utilization.
Possible Cause
u The programs running in the card are too many in quantity or some programs
occupy too much memory space.
Handling Procedure
1) Click the designated card in the Object Tree pane and select Config→
Service Config Management in the menu bar to access the Service
Config Management window.
6-12 Version: D
6 Prompt Alarms
2. Observe for a period of time to check whether the memory utilization ratio
decreases.
4 If yes, ➔ Step 4.
4 If no, ➔ Step 5.
1) Click the active HSWA card in the Object Tree pane and select Config→
Service Config Management in the menu bar to access the Service
Config Management window.
4) Input the appropriate CPU utilization threshold value in the CPU Usage
Threshold column.
4 If yes, ➔ Step 6.
Version: D 6-13
AN5116-06B Optical Line Terminal Equipment Alarm and Event Reference
1) Click the designated card in the Object Tree pane and select Config→
Service Config Management in the menu bar to access the Service
Config Management window.
2) Select Config→PM Class Threshold in the Menu Tree pane to open the
IPM Class Threshold tab.
6.2.5 OPTMODULE_TEMP_OVER
Alarm Information
Alarm Name Alarm Level Alarm Type
The optical module does not work well and services of the PON port will be
influenced and all services may even be disconnected.
Possible Cause
Handling Procedure
4 If the fan unit has faults or rotates too slowly, replace the fan unit.
4 If the ambient temperature is too high, improve the ventilation and take
cooling measures.
6-14 Version: D
6 Prompt Alarms
3. Check whether the setting of maximum and minimum threshold value for the
temperature is reasonable:
1) Click the active HSWA card in the Object Tree pane and select Config→
Service Config Management in the menu bar to access the Service
Config Management window.
6.2.6 OPTMODULE_TEMP_OVER
Alarm Information
Alarm Name Alarm Level Alarm Type
The optical module does not work well and services of the PON port will be
influenced and all services may even be disconnected.
Possible Cause
Version: D 6-15
AN5116-06B Optical Line Terminal Equipment Alarm and Event Reference
Handling Procedure
1. Check whether the setting of maximum and minimum threshold value for the
temperature is reasonable:
1) Click the active HSWA card in the Object Tree pane and select Config→
Service Config Management in the menu bar to access the Service
Config Management window.
¡ If no, ➔ Step 2.
2. Check whether the interface card works normally. Replace the optical module.
6.2.7 OPTMODULE_BIAS_OVER
Alarm Information
Alarm Name Alarm Level Alarm Type
The optical module does not work well and services of the PON port will be
influenced and all services may even be disconnected.
6-16 Version: D
6 Prompt Alarms
Possible Cause
u The setting of the alarm threshold value of the optical module's bias current is
unreasonable.
Handling Procedure
1. Observe the alarm for 5 minutes to check whether the alarm is removed
automatically.
2. Test the optical power of the OLT and ONU optical modules via the PON
dedicated optical power meter and testing optical fiber to check whether the
optical power is within the normal range:
4 If the optical power is not within the normal range, replace the optical
module.
Caution:
Checking whether the optical module is working normally will interrupt the
service.
3. Check whether the setting of maximum and minimum threshold value for the
temperature is reasonable:
1) Click the active HSWA card in the Object Tree pane and select Config→
Service Config Management in the menu bar to access the Service
Config Management window.
Version: D 6-17
AN5116-06B Optical Line Terminal Equipment Alarm and Event Reference
The maximum alarm threshold value for the bias current 100.0
The minimum alarm threshold value for the bias current 0.0
6.2.8 OPTMODULE_TXPOWER_OVER
Alarm Information
Alarm Name Alarm Level Alarm Type
The optical module does not work well and services of the PON port will be
influenced and all services may even be disconnected.
Possible Cause
u The setting of the alarm threshold value of the optical module's Tx optical
power is unreasonable.
Handling Procedure
1. Observe the alarm for 5 minutes to check whether the alarm is removed
automatically.
2. Test the Tx optical power of the PON optical module on the designated card via
the PON dedicated optical power meter and testing optical fiber to check
whether the optical power is within the normal range:
4 If the Tx optical power exceeds the maximum threshold, replace the optical
module or add the attenuator in the optical fiber line.
6-18 Version: D
6 Prompt Alarms
4 If the Tx optical power is lower than the threshold value, replace the optical
module.
Caution:
Checking whether the optical module is working normally will interrupt the
service.
3. Check whether the setting of maximum and minimum threshold value for the Tx
optical power is reasonable:
1) Click the active HSWA card in the Object Tree pane and select Config→
Service Config Management in the menu bar to access the Service
Config Management window.
Reference Information
The normal range of the optical module's Tx optical power on the OLT side is shown
in the following table:
Version: D 6-19
AN5116-06B Optical Line Terminal Equipment Alarm and Event Reference
Note:
PX10 means the 10km optical module and PX20 means the 20km optical
module. The 1490 nm power meter is used to test OLT side transmitting
optical power and ONU side receiving optical power. The 1310 nm power
meter is used to test OLT side receiving and ONU side transmitting
optical power.
6.2.9 OPTMODULE_RXPOWER_OVER
Alarm Information
Alarm Name Alarm Level Alarm Type
The optical module does not work well on the ONU side and services of the PON
port will be influenced and even all services are disconnected.
Possible Cause
u The setting of the alarm threshold value of the ONU Rx optical power is
unreasonable.
Handling Procedure
1. Observe the alarm for 5 minutes to check whether the alarm is removed
automatically.
6-20 Version: D
6 Prompt Alarms
2. Test the Tx optical power on the ONU side and via the PON dedicated optical
power meter and testing optical fiber to check whether the optical power is
within the normal range:
4 If the Tx optical power exceeds the maximum value, add the optical
attenuator or replace the ONU optical module.
4 If the Tx optical power is lower than the threshold value, place the ONU
optical module.
Caution:
Checking whether the optical module is working normally will interrupt the
service.
3. Check whether the setting of maximum and minimum threshold value for the
Rx optical power is reasonable:
1) Click the active HSWA card in the Object Tree pane and select Config→
Service Config Management in the menu bar to access the Service
Config Management window.
Version: D 6-21
AN5116-06B Optical Line Terminal Equipment Alarm and Event Reference
Reference Information
The normal range of the optical module's Rx optical power is from -29dBm to -6dBm.
6.2.10 ONU_TO_OLT_RXPOWER_OVER
Alarm Information
Alarm Name Alarm Level Alarm Type
The optical module does not work well on the ONU side and services of the PON
port will be influenced and even all services are disconnected.
Possible Cause
u The setting of the alarm threshold value of the Rx optical power from the ONU
to OLT is unreasonable.
Handling Procedure
1. Check whether the Tx optical power on the ONU side is normal via the PON
optical power meter and testing optical fiber and whether the optical module is
aged or damaged.
4 If the Tx optical power exceeds the maximum value, add the optical
attenuator or replace the ONU optical module.
4 If the Tx optical power is lower than the threshold value, place the ONU
optical module.
4 If the Tx optical power is within the normal range, contact FiberHome for
technical support.
2. Check whether the setting of maximum and minimum threshold value for the
Rx optical power is reasonable:
6-22 Version: D
6 Prompt Alarms
1) Click the active HSWA card in the Object Tree pane and select Config→
Service Config Management in the menu bar to access the Service
Config Management window.
6.2.11 TOTAL_BANDWIDTH_OVER
Alarm Information
Alarm Name Alarm Level Alarm Type
When a lot of subscriber services are running together, the quality of the subscriber
services may decrease, even some subscriber services may be interrupted.
Possible Cause
Under the PON port, the sum of the minimum guaranteed bandwidth of subscriber
services exceeds the maximum bandwidth of the system.
Handling Procedure
Version: D 6-23
AN5116-06B Optical Line Terminal Equipment Alarm and Event Reference
4 If not, add an OLT for the capacity expansion and assign the newly added
ONU to the PON port of this OLT.
6.3.1 ILEGAL_ONU_REGISTE
Alarm Information
Alarm Name Alarm Level Alarm Type
Possible Cause
Handling Procedure
a) Click the HSWA card in the Object Tree pane and select Config→
Service Config Management in the menu bar to access the Service
Config Management window.
6-24 Version: D
6 Prompt Alarms
b) Input the corresponding physical address and select the slot number,
PON port and ONU type.
• If the alarm still persists after the physical ID is added, ➔ Step 3).
a) Click the HSWA card in the Object Tree pane and select Config→
Service Config Management in the menu bar to access the Service
Config Management window.
¡ If the alarm still persists after the modification, contact FiberHome for
technical support.
Version: D 6-25
AN5116-06B Optical Line Terminal Equipment Alarm and Event Reference
1) Check whether the password of the ONU is in the password white list
a) Click the HSWA card in the Object Tree pane and select Config→
Service Config Management in the menu bar to access the Service
Config Management window.
b) Input the corresponding password and select the slot number, PON
port and ONU type.
• If the alarm still persists after the password is added, ➔ Step 3).
a) Click the HSWA card in the Object Tree pane and select Config→
Service Config Management in the menu bar to access the Service
Config Management window.
6-26 Version: D
6 Prompt Alarms
¡ If the alarm still persists after the modification, contact FiberHome for
technical support.
6.3.2 ONU_AUTO_CONFIG_FAILED
Alarm Information
Alarm Name Alarm Level Alarm Type
The ONU cannot be authorized and it cannot provide services for subscribers.
Possible Cause
u ONUs with the same MAC address of the PON port have authorized.
u The PON port accessed 128 ONUs and the 128 authorization numbers have
been assigned. If the 129th ONU is accessed to the PON port, the OLT cannot
assign the newly-added ONU with an authorization number.
u If the number of ONUs accessed to a PON port is less than 128 but the sum of
bandwidth assigned to these ONUs is greater than the total bandwidth of the
PON port, then the OLT cannot assign the newly added ONU with an
authorization number.
Handling Procedure
4 If no, ➔ Step 2.
Version: D 6-27
AN5116-06B Optical Line Terminal Equipment Alarm and Event Reference
2. Check the PON port’s total bandwidth and subscriber service bandwidth
assignment:
4 If the service bandwidth is larger than the PON port’s total bandwidth,
adjust the service bandwidth and ➔ Step 3.
3. Authorize the ONU again manually under this OLT. Refer to Configuration
Guide for more details.
6.3.3 CPU_USAGE_OVER_THRESHOLD
Alarm Information
Alarm Name Alarm Level Alarm Type
The CPU running speed of this card may become lower, and the system may
collapse because of the excessive utilization.
Possible Cause
u The programs running in the card are too many in quantity or too large in size.
Handling Procedure
1) Click the designated card in the Object Tree pane and select Config→
Service Config Management in the menu bar to access the Service
Config Management window.
6-28 Version: D
6 Prompt Alarms
2. Observe for a period of time to check whether the CPU utilization ratio
decreases.
4 If yes, ➔ Step 4.
4 If no, ➔ Step 5.
1) Click the active HSWA card in the Object Tree pane and select Config→
Service Config Management in the menu bar to access the Service
Config Management window.
4) Input the appropriate CPU utilization threshold value in the CPU Usage
Threshold (%) column.
4 If yes, ➔ Step 6.
1) Click the designated card in the Object Tree pane and select Config→
Service Config Management in the menu bar to access the Service
Config Management window.
2) Select Config→PM Class Threshold in the Menu Tree pane to open the
IPM Class Threshold tab.
Version: D 6-29
AN5116-06B Optical Line Terminal Equipment Alarm and Event Reference
6.3.4 MEM_USAGE_OVER_THRESHOLD
Alarm Information
Alarm Name Alarm Level Alarm Type
The CPU running speed of this card may become lower, and the system may
collapse because of the excessive utilization.
Possible Cause
u The programs running in the card are too many in quantity or some programs
occupy too much memory space.
Handling Procedure
1) Click the designated card in the Object Tree pane and select Config→
Service Config Management in the menu bar to access the Service
Config Management window.
2. Observe for a period of time to check whether the memory utilization ratio
decreases.
6-30 Version: D
6 Prompt Alarms
4 If yes, ➔ Step 4.
4 If no, ➔ Step 5.
1) Click the active HSWA card in the Object Tree pane and select Config→
Service Config Management in the menu bar to access the Service
Config Management window.
4) Input the appropriate CPU utilization threshold value in the CPU Usage
Threshold column.
4 If yes, ➔ Step 6.
1) Click the designated card in the Object Tree pane and select Config→
Service Config Management in the menu bar to access the Service
Config Management window.
2) Select Config→PM Class Threshold in the Menu Tree pane to open the
IPM Class Threshold tab.
Version: D 6-31
AN5116-06B Optical Line Terminal Equipment Alarm and Event Reference
6.3.5 ONU_UNAUTHENTICATED
Alarm Information
Alarm Name Alarm Level Alarm Type
After being authorized, the ONU can provide services for system.
Possible Cause
The designated card has detected that an ONU is registered, but cannot find the
corresponding item that matches this ONU’s MAC address in the local authorization
table.
Handling Procedure
1. Omit this alarm or authorize the unauthorized ONU (take the authentication
mode based on the physical ID as example):
1) Click the active HSWA card in the Object Tree pane and select Config→
Service Config Management in the menu bar to access the Service
Config Management window.
3) In the PON Authentication Mode tab, select the slot and the PON port of
the designated and set the corresponding authentication mode as
PHYSIC_ID AUTHENTICATION. Then click the Create on Device button
to write the configuration to the equipment.
6) In the Obtain Unauthorized ONU dialog box that appears, select the
corresponding slot number and PON port number, and then click the
Obtain Unauthorized ONU button under the dialog box.
6-32 Version: D
6 Prompt Alarms
7) The lower pane will display the unauthorized ONUs. Select the ONUs to be
authorized and click the OK button to authorize them.
6.3.6 OPTMODULE_TEMP_OVER
Alarm Information
Alarm Name Alarm Level Alarm Type
The optical module does not work well and services of the PON port will be
influenced and all services may even be disconnected.
Possible Cause
Handling Procedure
4 If the fan unit has faults or rotates too slowly, replace the fan unit.
4 If the ambient temperature is too high, improve the ventilation and take
cooling measures.
3. Check whether the setting of maximum and minimum threshold value for the
temperature is reasonable:
1) Click the active HSWA card in the Object Tree pane and select Config→
Service Config Management in the menu bar to access the Service
Config Management window.
Version: D 6-33
AN5116-06B Optical Line Terminal Equipment Alarm and Event Reference
6.3.7 OPTMODULE_TEMP_OVER
Alarm Information
Alarm Name Alarm Level Alarm Type
The optical module does not work well and services of the PON port will be
influenced and all services may even be disconnected.
Possible Cause
Handling Procedure
1. Check whether the setting of maximum and minimum threshold value for the
temperature is reasonable:
1) Click the active HSWA card in the Object Tree pane and select Config→
Service Config Management in the menu bar to access the Service
Config Management window.
6-34 Version: D
6 Prompt Alarms
¡ If no, ➔ Step 2.
2. Check whether the interface card works normally. Replace the optical module.
6.3.8 OPTMODULE_BIAS_OVER
Alarm Information
Alarm Name Alarm Level Alarm Type
The optical module does not work well and services of the PON port will be
influenced and all services may even be disconnected.
Possible Cause
u The setting of the alarm threshold value of the optical module's bias current is
unreasonable.
Version: D 6-35
AN5116-06B Optical Line Terminal Equipment Alarm and Event Reference
Handling Procedure
1. Observe the alarm for 5 minutes to check whether the alarm is removed
automatically.
2. Test the optical power of the OLT and ONU optical modules via the PON
dedicated optical power meter and testing optical fiber to check whether the
optical power is within the normal range:
4 If the optical power is not within the normal range, replace the optical
module.
Caution:
Checking whether the optical module is working normally will interrupt the
service.
3. Check whether the setting of maximum and minimum threshold value for the
temperature is reasonable:
1) Click the active HSWA card in the Object Tree pane and select Config→
Service Config Management in the menu bar to access the Service
Config Management window.
The maximum alarm threshold value for the bias current 100.0
The minimum alarm threshold value for the bias current 0.0
6-36 Version: D
6 Prompt Alarms
6.3.9 OPTMODULE_TXPOWER_OVER
Alarm Information
Alarm Name Alarm Level Alarm Type
The optical module does not work well and services of the PON port will be
influenced and all services may even be disconnected.
Possible Cause
u The setting of the alarm threshold value of the optical module's Tx optical
power is unreasonable.
Handling Procedure
1. Observe the alarm for 5 minutes to check whether the alarm is removed
automatically.
2. Test the Tx optical power of the PON optical module on the designated card via
the PON dedicated optical power meter and testing optical fiber to check
whether the optical power is within the normal range:
4 If the Tx optical power exceeds the maximum threshold, replace the optical
module or add the attenuator in the optical fiber line.
4 If the Tx optical power is lower than the threshold value, replace the optical
module.
Caution:
Checking whether the optical module is working normally will interrupt the
service.
Version: D 6-37
AN5116-06B Optical Line Terminal Equipment Alarm and Event Reference
3. Check whether the setting of maximum and minimum threshold value for the Tx
optical power is reasonable:
1) Click the active HSWA card in the Object Tree pane and select Config→
Service Config Management in the menu bar to access the Service
Config Management window.
Reference Information
The normal range of the optical module's Tx optical power on the OLT side is shown
in the following table:
Note:
The Class B+ optical module allows channel insertion loss of 28dB and
supports the optical split ratio up to 1:64; tThe Class C+ optical module
allows channel insertion loss of 32dB and supports the optical split ratio
up to 1:128.
6-38 Version: D
6 Prompt Alarms
6.3.10 OPTMODULE_RXPOWER_OVER
Alarm Information
Alarm Name Alarm Level Alarm Type
The optical module does not work well on the ONU side and services of the PON
port will be influenced and even all services are disconnected.
Possible Cause
u The setting of the alarm threshold value of the ONU Rx optical power is
unreasonable.
Handling Procedure
1. Observe the alarm for 5 minutes to check whether the alarm is removed
automatically.
2. Test the Tx optical power on the ONU side and via the PON dedicated optical
power meter and testing optical fiber to check whether the optical power is
within the normal range:
4 If the Tx optical power exceeds the maximum value, add the optical
attenuator or replace the ONU optical module.
4 If the Tx optical power is lower than the threshold value, replace the ONU
optical module.
Caution:
Checking whether the optical module is working normally will interrupt the
service.
Version: D 6-39
AN5116-06B Optical Line Terminal Equipment Alarm and Event Reference
3. Check whether the setting of maximum and minimum threshold value for the
Rx optical power is reasonable:
1) Click the active HSWA card in the Object Tree pane and select Config→
Service Config Management in the menu bar to access the Service
Config Management window.
Reference Information
The normal range of the optical module's Rx optical power is from -29dBm to -6dBm.
6.3.11 ONU_TO_OLT_RXPOWER_OVER
Alarm Information
Alarm Name Alarm Level Alarm Type
The optical module does not work well and services of the PON port will be
influenced and all services may even be disconnected.
Possible Cause
6-40 Version: D
6 Prompt Alarms
u The setting of the alarm threshold value of the ONU Rx optical power is
unreasonable.
Handling Procedure
1. Check whether the optical power is normal via the PON optical power meter
and testing optical fiber and whether the optical module is aged or damaged.
2. Check whether the setting of maximum and minimum threshold value for the
Rx optical power is reasonable:
1) Click the active HSWA card in the Object Tree pane and select Config→
Service Config Management in the menu bar to access the Service
Config Management window.
6.3.12 TOTAL_BANDWIDTH_OVER
Alarm Information
Alarm Name Alarm Level Alarm Type
Version: D 6-41
AN5116-06B Optical Line Terminal Equipment Alarm and Event Reference
When a lot of subscriber services are running together, the quality of the subscriber
services may decrease, even some subscriber services may be interrupted.
Possible Cause
Under the PON port, the sum of the minimum guaranteed bandwidth of subscriber
services exceeds the maximum bandwidth of the system.
Handling Procedure
4 If not, add an OLT for the capacity expansion and assign the newly added
ONU to the PON port of this OLT.
6.4.1 CPU_USAGE_OVER_THRESHOLD
Alarm Information
Alarm Name Alarm Level Alarm Type
The CPU running speed of this card may become lower, and the system may
collapse.
Possible Cause
u The programs running in the card are too many in quantity or too large in size.
6-42 Version: D
6 Prompt Alarms
Handling Procedure
1) Click the CE1B card in the Object Tree pane and select Config→Service
Config Management in the menu bar to access the Service Config
Management window.
2. Observe for a period of time to check whether the CPU utilization ratio
decreases.
4 If yes, ➔ Step 4.
1) Click the active HSWA card in the Object Tree pane and select Config→
Service Config Management in the menu bar to access the Service
Config Management window.
4) Input the appropriate CPU utilization threshold value in the CPU Usage
Threshold (%) column.
Version: D 6-43
AN5116-06B Optical Line Terminal Equipment Alarm and Event Reference
6.4.2 MEM_USAGE_OVER_THRESHOLD
Alarm Information
Alarm Name Alarm Level Alarm Type
The CPU running speed of this card may become lower, and the system may
collapse.
Possible Cause
u The programs running in the card are too many in quantity or some programs
occupy too much memory space.
Handling Procedure
1) Click the CE1B card in the Object Tree pane and select Config→Service
Config Management in the menu bar to access the Service Config
Management window.
2. Observe for a period of time to check whether the memory utilization ratio
decreases.
6-44 Version: D
6 Prompt Alarms
4 If yes, ➔ Step 4.
1) Click the active HSWA card in the Object Tree pane and select Config→
Service Config Management in the menu bar to access the Service
Config Management window.
4) Input the appropriate memory utilization threshold value in the CPU Usage
Threshold column.
6.5.1 CPU_USAGE_OVER_THRESHOLD
Alarm Information
Alarm Name Alarm Level Alarm Type
The CPU running speed of this card may become lower, and the system may
collapse.
Possible Cause
u The programs running in the card are too many in quantity or too large in size.
Version: D 6-45
AN5116-06B Optical Line Terminal Equipment Alarm and Event Reference
Handling Procedure
1) Click the C155A card in the Object Tree pane and select Config→
Service Config Management in the menu bar to access the Service
Config Management window.
2. Observe for a period of time to check whether the CPU utilization ratio
decreases.
4 If yes, ➔ Step 4.
1) Click the active HSWA card in the Object Tree pane and select Config→
Service Config Management in the menu bar to access the Service
Config Management window.
4) Input the appropriate CPU utilization threshold value in the CPU Usage
Threshold (%) column.
6-46 Version: D
6 Prompt Alarms
6.5.2 MEM_USAGE_OVER_THRESHOLD
Alarm Information
Alarm Name Alarm Level Alarm Type
The CPU running speed of this card may become lower, and the system may
collapse.
Possible Cause
u The programs running in the card are too many in quantity or some programs
occupy too much memory space.
Handling Procedure
1) Click the C155A card in the Object Tree pane and select Config→
Service Config Management in the menu bar to access the Service
Config Management window.
2. Observe for a period of time to check whether the memory utilization ratio
decreases.
Version: D 6-47
AN5116-06B Optical Line Terminal Equipment Alarm and Event Reference
4 If yes, ➔ Step 4.
1) Click the active HSWA card in the Object Tree pane and select Config→
Service Config Management in the menu bar to access the Service
Config Management window.
Alarm Information
Alarm Name Alarm Level Alarm Type
User_defined_alarm1 to
Prompt alarm Environmental alarm
User_defined_alarm14
Possible Cause
u The PUBA card detects that the signals at the dry contact change.
6-48 Version: D
6 Prompt Alarms
Handling Procedure
4 If yes, ➔ Step 2.
1) Click the PUBA card in the Object Tree pane and select Config→Service
Config Management in the menu bar to access the Service Config
Management window.
2) Select Config→User Defined Alarm Config in the Menu Tree and the
User Defined Alarm Config window appears.
6.7.1 PORT_DISCONNECTED
Alarm Information
Alarm Name Alarm Level Alarm Type
Version: D 6-49
AN5116-06B Optical Line Terminal Equipment Alarm and Event Reference
Note:
The alarm only occurs in the uplink card whose unplink port is the
Ethernet interface.
All services on the unplink card port will be interrupted in the OLT system.
Possible Cause
Handling Procedure
1. Make sure that the port is disabled manually or the network cable is unplugged.
4 If no, ➔ Step 2.
2. Check whether the connection of the optical fiber or the network cable of the
uplink card and the far end equipment is normal.
4 If yes, ➔ Step 3.
4 If the equipment fails to power on, power on the equipment. If the alarm is
removed, no handling is needed.
6-50 Version: D
6 Prompt Alarms
6.7.2 UP_SPEED_OVER_THRESHOLD
Alarm Information
Alarm Name Alarm Level Alarm Type
Possible Cause
u The real-time uplink rate of the uplink card port exceeds the configured pre-
warning threshold.
Handling Procedure
1. Click the system in the Object Tree pane and select Config→Service Config
Management in the menu bar to access the Service Config Management
window.
3. Click the used template to check whether the alarm reporting threshold whose
Alarm Code is UP_SPEED_OVER_THRESHOLD needs to be modified.
4 If yes, ➔ Step 4.
4 If no, ➔ Step 6.
6. If the traffic of the uplink card port exceeds the expectation, it is recommended
to configure the LACP to perform traffic sharing for the uplink port. For the
Version: D 6-51
AN5116-06B Optical Line Terminal Equipment Alarm and Event Reference
6.7.3 DOWN_SPEED_OVER_THRESHOLD
Alarm Information
Alarm Name Alarm Level Alarm Type
Possible Cause
u The real-time downlink rate of the uplink card port exceeds the configured pre-
warning threshold.
Handling Procedure
1. Click the system in the Object Tree pane and select Config→Service Config
Management in the menu bar to access the Service Config Management
window.
3. Click the used template to check whether the alarm reporting threshold whose
Alarm Code is DOWN_SPEED_OVER_THRESHOLD needs to be modified.
4 If yes, ➔ Step 4.
4 If no, ➔ Step 6.
6-52 Version: D
6 Prompt Alarms
6. If the traffic of the uplink card port exceeds the expectation, it is recommended
to configure the LACP to perform traffic sharing for the uplink port. For the
detailed operations, refer to EPON Configuration Guide or GPON Configuration
Guide.
6.8.1 OPTICAL_POWER_LOW
Alarm Information
Alarm Name Alarm Level Alarm Type
The optical module works unstably and the ONU service is influenced or even all
services are disconnected.
Possible Cause
Handling Procedure
1. Observe the alarm for 5 minutes to check whether the alarm is removed
automatically.
Version: D 6-53
AN5116-06B Optical Line Terminal Equipment Alarm and Event Reference
2. Test the optical power of the OLT and ONU optical modules via the PON
dedicated optical power meter and testing optical fiber to check whether the
optical power is within the normal range:
4 If the optical power is not within the normal range, replace the optical
module.
4 If the Tx optical power is within the normal range, contact FiberHome for
technical support.
Caution:
Checking whether the optical module is working normally will interrupt the
service.
6.8.2 PROTECT_VOICE_SERVICE_ONLY
Alarm Information
Alarm Name Alarm Level Alarm Type
When the storage battery voltage is too low, the ONU fails to work normally, which
cannot provide voice services for users.
Possible Cause
Handling Procedure
1. Check whether the alarm is removed after replacing the ONU standby battery:
6-54 Version: D
6 Prompt Alarms
Alarm Information
Alarm Name Alarm Level Alarm Type
User_defined_alarm1 to
Prompt alarm Environmental alarm
User_defined_alarm5
The running environment of the equipment may change. The change in some
environmental parameters may lead to the equipment running instability, even may
result in the equipment failure. To ensure the long-period and stable running of the
equipment, users need to handle this alarm immediately.
Possible Cause
u The ONU detects that the signals at the dry contact change.
Note:
Handling Procedure
4 If yes, ➔ Step 2.
1) Click the PON interface connected to the ONU in the Object Tree pane
and select Config→Service Config Management in the menu bar to
access the Service Config Management window.
Version: D 6-55
AN5116-06B Optical Line Terminal Equipment Alarm and Event Reference
2) Click the ONU under the interface card in the Remote Object tab in the
Object Tree pane, and select Config→Custom Alarm Config in the
Menu Tree pane to open the Custom Alarm Config tab.
6.8.4 DOW
Alarm Information
Alarm Name Alarm Level Alarm Type
The services of the ONU may be interrupted and the ONU may even be
disconnected.
Possible Cause
The Tx signals of the ONU do not arrive at the expected positions due to the loss on
the optical fiber, bad connection at the interface and optical module fault.
Handling Procedure
1. Restart the ONU and observe for 5 minutes to see whether the alarm is
removed.
2. View and confirm that the optical fiber is connected with the interface normally.
If optical fiber loss occurs or the interfaces are not firmly connected, replace the
optical fiber or restore the normal connection on the interface.
6-56 Version: D
6 Prompt Alarms
3. Test whether the ONU's optical module is normal with the PON dedicated
optical power meter and testing optical fiber.
4 If no, replace the optical module. If the alarm ends after the replacement,
no handling is needed; if the alarm still persists, please contact FiberHome
for technical support.
4 If the equipment at the far end works normally, contact FiberHome for
technical support.
Caution:
Checking whether the optical module is working normally will interrupt the
service.
6.8.5 SF
Alarm Information
Alarm Name Alarm Level Alarm Type
The services of the ONU may be interrupted and the ONU may even be
disconnected.
Possible Cause
The bit error rate of the ONU’s uplink service flow≥10-X (8≥X≥3) due to the loss on
the optical fiber, bad connection at the interface and optical module fault.
Handling Procedure
1. Restart the ONU and observe for 5 minutes to see whether the alarm is
removed.
Version: D 6-57
AN5116-06B Optical Line Terminal Equipment Alarm and Event Reference
2. View and confirm that the optical fiber is connected with the interface normally.
If optical fiber loss occurs or the interfaces are not firmly connected, replace the
optical fiber or restore the normal connection on the interface.
3. Test whether the ONU's optical module is normal with the PON dedicated
optical power meter and testing optical fiber.
4 If no, replace the optical module. If the alarm ends after the replacement,
no handling is needed; if the alarm still persists, please contact FiberHome
for technical support.
4 If the equipment at the far end works normally, contact FiberHome for
technical support.
Caution:
Checking whether the optical module is working normally will interrupt the
service.
6.8.6 SD
Alarm Information
Alarm Name Alarm Level Alarm Type
The services of the ONU may be interrupted and the ONU may even be
disconnected.
Possible Cause
The bit error rate of the ONU’s uplink service flow≥10-Y (9≥Y≥4, and Y should be
larger than the X in the ONU_SF alarm) due to the loss on the optical fiber, bad
connection at the interface and optical module fault.
6-58 Version: D
6 Prompt Alarms
Handling Procedure
1. Restart the ONU and observe for 5 minutes to see whether the alarm is
removed.
2. View and confirm that the optical fiber is connected with the interface normally.
If optical fiber loss occurs or the interfaces are not firmly connected, replace the
optical fiber or restore the normal connection on the interface.
3. Test whether the ONU's optical module is normal with the PON dedicated
optical power meter and testing optical fiber.
4 If no, replace the optical module. If the alarm ends after the replacement,
no handling is needed; if the alarm still persists, please contact FiberHome
for technical support.
4 If the equipment at the far end works normally, contact FiberHome for
technical support.
Caution:
Checking whether the optical module is working normally will interrupt the
service.
6.8.7 LCDG
Alarm Information
Alarm Name Alarm Level Alarm Type
The services of the ONU may be interrupted and the ONU may even be
disconnected.
Version: D 6-59
AN5116-06B Optical Line Terminal Equipment Alarm and Event Reference
Possible Cause
Loss of GEM channel delineation occurs on the ONU due to the loss on the optical
fiber, bad connection at the interface and optical module fault.
Handling Procedure
1. Restart the ONU and observe for 5 minutes to see whether the alarm is
removed.
2. View and confirm that the optical fiber is connected with the interface normally.
If optical fiber loss occurs or the interfaces are not firmly connected, replace the
optical fiber or restore the normal connection on the interface.
3. Test whether the ONU's optical module is normal with the PON dedicated
optical power meter and testing optical fiber.
4 If no, replace the optical module. If the alarm ends after the replacement,
no handling is needed; if the alarm still persists, please contact FiberHome
for technical support.
4 If the equipment at the far end works normally, contact FiberHome for
technical support.
Caution:
Checking whether the optical module is working normally will interrupt the
service.
6.8.8 RDI
Alarm Information
Alarm Name Alarm Level Alarm Type
6-60 Version: D
6 Prompt Alarms
The services of the ONU may be interrupted and the ONU may even be
disconnected.
Possible Cause
The ONU has detected that the data from the OLT have faults due to the loss on the
optical fiber, bad connection at the interface and optical module fault.
Handling Procedure
1. Restart the ONU and observe for 5 minutes to see whether the alarm is
removed.
2. View and confirm that the optical fiber is connected with the interface normally.
If optical fiber loss occurs or the interfaces are not firmly connected, replace the
optical fiber or restore the normal connection on the interface.
3. Test whether the ONU's optical module is normal with the PON dedicated
optical power meter and testing optical fiber.
4 If no, replace the optical module. If the alarm ends after the replacement,
no handling is needed; if the alarm still persists, please contact FiberHome
for technical support.
4 If the equipment at the far end works normally, contact FiberHome for
technical support.
Caution:
Checking whether the optical module is working normally will interrupt the
service.
Version: D 6-61
AN5116-06B Optical Line Terminal Equipment Alarm and Event Reference
6.8.9 SUF
Alarm Information
Alarm Name Alarm Level Alarm Type
The services can only be configured after the ONU distance measurement is
successful.
Possible Cause
After the OLT has received the optical pulse from the ONU, the ONU distance
measurement has been failed twice.
Handling Procedure
1. Restart the ONU and observe for 5 minutes to see whether the alarm is
removed.
2. View and confirm that the optical fiber is connected with the interface normally.
If optical fiber loss occurs or the interfaces are not firmly connected, replace the
optical fiber or restore the normal connection on the interface.
3. Test whether the ONU's optical module is normal with the PON dedicated
optical power meter and testing optical fiber.
4 If no, replace the optical module. If the alarm ends after the replacement,
no handling is needed; if the alarm still persists, please contact FiberHome
for technical support.
4 If the equipment at the far end works normally, contact FiberHome for
technical support.
6-62 Version: D
6 Prompt Alarms
Caution:
Checking whether the optical module is working normally will interrupt the
service.
Reference Information
Distance measurement: The PON system uses the TDMA uplink mode; the
transmission of all uplink data is controlled by the OLT. For the differential fiber
distance of up to 20 km, the difference between the transmission delays from the
nearest ONU to the OLT and the furthest ONU to the OLT is 100µs. In order to avoid
the uplink burst data collision between different ONUs, the OLT should measure the
relative distance. The OLT should measure the relative distance from each ONU to
the OLT according to the round-trip transmission delay and adjust the ONU uplink
transmission time, so as to ensure that all the ONU reaches OLT simultaneously.
6.8.10 LOA
Alarm Information
Alarm Name Alarm Level Alarm Type
Possible Cause
The OLT has not received the uplink confirmation information that should have been
sent from the ONU due to the loss on the optical fiber, bad connection at the
interface and optical module fault.
Handling Procedure
1. Restart the ONU and observe for 5 minutes to see whether the alarm is
removed.
Version: D 6-63
AN5116-06B Optical Line Terminal Equipment Alarm and Event Reference
2. View and confirm that the optical fiber is connected with the interface normally.
If optical fiber loss occurs or the interfaces are not firmly connected, replace the
optical fiber or restore the normal connection on the interface.
3. Test whether the ONU's optical module is normal with the PON dedicated
optical power meter and testing optical fiber.
4 If no, replace the optical module. If the alarm ends after the replacement,
no handling is needed; if the alarm still persists, please contact FiberHome
for technical support.
4 If the equipment at the far end works normally, contact FiberHome for
technical support.
Caution:
Checking whether the optical module is working normally will interrupt the
service.
6.8.11 MEM
Alarm Information
Alarm Name Alarm Level Alarm Type
Possible Cause
The OLT receives unknown messages from the ONU due to the loss on the optical
fiber, bad connection at the interface and optical module fault.
6-64 Version: D
6 Prompt Alarms
Handling Procedure
1. Restart the ONU and observe for 5 minutes to see whether the alarm is
removed.
2. View and confirm that the optical fiber is connected with the interface normally.
If optical fiber loss occurs or the interfaces are not firmly connected, replace the
optical fiber or restore the normal connection on the interface.
3. Test whether the ONU's optical module is normal with the PON dedicated
optical power meter and testing optical fiber.
4 If no, replace the optical module. If the alarm ends after the replacement,
no handling is needed; if the alarm still persists, please contact FiberHome
for technical support.
4 If the equipment at the far end works normally, contact FiberHome for
technical support.
Caution:
Checking whether the optical module is working normally will interrupt the
service.
6.8.12 PEE
Alarm Information
Alarm Name Alarm Level Alarm Type
The services of the ONU may be interrupted and the ONU may even be
disconnected.
Version: D 6-65
AN5116-06B Optical Line Terminal Equipment Alarm and Event Reference
Possible Cause
The OLT receives a PEE message from the ONU due to the loss on the optical fiber,
bad connection at the interface and optical module fault.
Handling Procedure
1. Restart the ONU and observe for 5 minutes to see whether the alarm is
removed.
2. View and confirm that the optical fiber is connected with the interface normally.
If optical fiber loss occurs or the interfaces are not firmly connected, replace the
optical fiber or restore the normal connection on the interface.
3. Test whether the ONU's optical module is normal with the PON dedicated
optical power meter and testing optical fiber.
4 If no, replace the optical module. If the alarm ends after the replacement,
no handling is needed; if the alarm still persists, please contact FiberHome
for technical support.
4 If the equipment at the far end works normally, contact FiberHome for
technical support.
Caution:
Checking whether the optical module is working normally will interrupt the
service.
Reference Information
PEE: Physical Equipment Error, indicating to the OLT that this ONU cannot
simultaneously transmit the GEM frame and the OMCI frame from the GEM layer to
the TC layer.
6-66 Version: D
6 Prompt Alarms
6.8.13 MIS
Alarm Information
Alarm Name Alarm Level Alarm Type
The services of the ONU may be interrupted and the ONU may even be
disconnected.
Possible Cause
The optical fiber loss occurs, the interface is not connected securily or the optical
module is faulty.
Handling Procedure
1. Restart the ONU and observe for 5 minutes to see whether the alarm is
removed.
2. View and confirm that the optical fiber is connected with the interface normally.
If optical fiber loss occurs or the interfaces are not firmly connected, replace the
optical fiber or restore the normal connection on the interface.
3. Test whether the ONU's optical module is normal with the PON dedicated
optical power meter and testing optical fiber.
4 If no, replace the optical module. If the alarm ends after the replacement,
no handling is needed; if the alarm still persists, please contact FiberHome
for technical support.
4 If the equipment at the far end works normally, contact FiberHome for
technical support.
Version: D 6-67
AN5116-06B Optical Line Terminal Equipment Alarm and Event Reference
Caution:
Checking whether the optical module is working normally will interrupt the
service.
6-68 Version: D
7 Critical Events
The following introduces properties, possible reasons, influences on the system and
handling procedures of critical events of the equipment.
Version: D 7-1
AN5116-06B Optical Line Terminal Equipment Alarm and Event Reference
The following introduces properties, possible reasons, influences on the system and
handling procedures of all critical events on the HSWA card.
7.1.1 OLT_REGISER_FAILED
Event information
Event Name Event Level
OLT_REGISER_FAILED Critical Events
Faults occur when the OLT adds in the resource management system and resource
management system of the network operator fails to manage the OLT.
Possible Cause
The communication between the ANM2000 and the resource management system
of the network operator is interrupted.
Handling Procedure
1. Test whether the physical link between the ANM2000 and the resource
management system of the network operator is normal.
7.1.2 License_Esn_Fail
Event information
Event Name Event Level
License_Esn_Fail Critical Events
7-2 Version: D
7 Critical Events
Possible Cause
Handling Procedure
1. Click the HSWA card in the Object Tree pane and select Config→Service
Config Management in the menu bar to access the Service Config
Management window.
2. Select License→Esn Query in the Menu Tree to open the Esn Query tab.
4. FiberHome engineer will modify the ESN and IP and provide a new License.
Upload the new License to the FTP server.
6. Set the parameters and click Create on Device to download the License to the
equipment.
The following introduces properties, possible reasons, influences on the system and
handling procedures of all critical events.
7.2.1 PULL_OUT_CARD
Event information
Event Name Event Level
PULL_OUT_CARD Critical Events
Version: D 7-3
AN5116-06B Optical Line Terminal Equipment Alarm and Event Reference
All functions of this card are disabled and all services on this card are interrupted;
that is, the card cannot provide the relevant services and functions.
Possible Cause
A card is unplugged.
Handling Procedure
4 If yes, insert the card into the equipment again. The system will give a
critical event, i.e. the INSERT_CARD event after the card is started.
7.2.2 INSERT_CARD
Event information
Event Name Event Level
INSERT_CARD Critical Events
The card cannot provide the corresponding services and functions before it is
started.
Possible Cause
Handling Procedure
7-4 Version: D
7 Critical Events
The following introduces properties, possible reasons, influences on the system and
handling procedures of all ONU critical events.
7.3.1 HG_REGISTER_FAILED
Event information
Event Name Event Level
HG_REGISTER_FAILED Critical Events
Faults occur when the home gateway adds in the resource management system
and resource management system of the network operator fails to manage the
home gateway.
Possible Cause
The communication between the ANM2000 and the resource management system
of the network operator is interrupted.
Handling Procedure
1. Test whether the physical link between the ANM2000 and the resource
management system of the network operator is normal.
7.3.2 ONU_REGISTER_FAILED
Event information
Event Name Event Level
ONU_REGISTER_FAILED Critical Events
Version: D 7-5
AN5116-06B Optical Line Terminal Equipment Alarm and Event Reference
Faults occur when the ONU adds in the resource management system and
resource management system of the network operator fails to manage the ONU.
Possible Cause
The communication between the ANM2000 and the resource management system
of the network operator is interrupted.
Handling Procedure
1. Test whether the physical link between the ANM2000 and the resource
management system of the network operator is normal.
7.3.3 UPGRADE_FILE_DISMATCH
Event information
Event Name Event Level
UPGRADE_FILE_DISMATCH Critical Events
The ONU fails to provide services for users because the ONU cannot be upgraded.
Possible Cause
The file type of the ONU upgrade files does not match that of the ONU to be
ungraded.
Handling Procedure
1. Check whether the file type of the ONU upgrade files matches that of the ONU
to be ungraded.
7-6 Version: D
7 Critical Events
7.3.4 UPGRADE_FAILURE
Event information
Event Name Event Level
UPGRADE_FAILURE Critical Events
The ONU fails to provide services for users because the ONU cannot be upgraded.
Possible Cause
u The file type of the ONU upgrade files does not match that of the ONU to be
ungraded.
u AN5116-06BThe connection between the and the ONU is interrupted and the
upgrade files fails to be delivered to the ONU to be upgraded.
Handling Procedure
1. Check whether the file type of the ONU upgrade files matches that of the ONU
to be ungraded.
4 If yes, ➔ Step 2.
4 If yes, ➔ Step 3.
4 If not, ➔ Step 4.
4. Click the EC4B / EC8B / XG2B or GC4B/ GC8B card in the Object Tree pane
and select Config→Service Config Management in the menu bar to access
the Service Config Management window.
Version: D 7-7
AN5116-06B Optical Line Terminal Equipment Alarm and Event Reference
5. Select Control Command→Reset ONU in the Menu Tree pane to reboot the
ONU to be upgraded. Wait for two minutes,
7.3.5 AUTO_UPGRADE_FAILURE
Event information
Event Name Event Level
AUTO_UPGRADE_FAILURE Critical Events
The ONU fails to provide services for users because the ONU cannot be upgraded.
Possible Cause
u The file type of the ONU cannot be identified or the checking of the upgrade file
is faulty.
u The file type of the ONU upgrade files does not match that of the ONU to be
ungraded.
u The core switch card and the PON interface card have communication faults.
Handling Procedure
1. Check additional alarm information to judge the type of faults via alarms and
perform corresponding troubleshootings. Five faults are listed below:
4 If the prompt is Unknown upgrade file type or wrong crc of file., check
the upgrade files.
¡ If the ONU upgrade file does not match the to-be-upgraded ONU file
type, use the correct upgrade files to upgrade the ONU.
7-8 Version: D
7 Critical Events
4 If the prompt is Unconsistent upgrade file type with ONU type., check
the ONU type.
¡ If the ONU upgrade file does not match the to-be-upgraded ONU file
type, use the correct upgrade files to upgrade the ONU.
4 If the prompt is Error occurs when download files from FTP server.,
check the configuration of the FTP server.
¡ If the FTP server does not work normally, configure and start the FTP
server again.
¡ If the line between the interface card and the ONU is normal and no
fiber cut alarm and far end ONU communication interruption occur, ➔
Step 2.
¡ If the line between the interface card and the ONU is abnormal and no
fiber cut alarm and far end ONU communication interruption occur,
refer to LINK_LOSS.
2. Click the EC4B / EC8B / XG2B or GC4B/ GC8B card in the Object Tree pane
and select Config→Service Config Management in the menu bar to access
the Service Config Management window.
3. Select Control Command→Reboot ONU in the Menu Tree pane to reboot the
ONU to be upgraded. Wait for two minutes,
Version: D 7-9
AN5116-06B Optical Line Terminal Equipment Alarm and Event Reference
7-10 Version: D
8 Minor Events
The following introduces properties, possible reasons, influences on the system and
handling procedures of minor events of the equipment.
Version: D 8-1
AN5116-06B Optical Line Terminal Equipment Alarm and Event Reference
The following introduces properties, possible reasons, influences on the system and
handling procedures of minor events of the ONU.
8.1.1 NGN_SET_FAIL
Event information
Event Name Event Level
NGN_SET_FAIL Minor Events
Possible Cause
Handling Procedure
1) Click the EC4B / EC8B / XG2B or GC4B/ GC8B card in the Object Tree
pane and select Config→Service Config Management in the menu bar
to access the Service Config Management window.
3) Check the ONU authentication table to find whether the ONU is in the ONU
authentication table.
¡ If yes, ➔ Step 2.
¡ If not, check whether the fiber cut alarm exists in the ONU and re-
authorize the ONU.
8-2 Version: D
8 Minor Events
2. Check whether the voice service configuration of the OLT and ONU is correct
and whether the voice service configuration is consistent with the planning
data.
8.1.2 NGN_VERSION_ERROR
Event information
Event Name Event Level
NGN_VERSION_ERROR Minor Events
Possible Cause
The voice protocol type configured for the ONU software version is inconsistent with
the actual type.
Handling Procedure
1. Check whether the protocol type configuration of the OLT and ONU voice
service is correct and whether the voice service configuration is consistent with
the planning data.
Version: D 8-3
9 Prompt Events
The following introduces properties, possible reasons, influences on the system and
handling procedures of all prompt events.
Version: D 9-1
AN5116-06B Optical Line Terminal Equipment Alarm and Event Reference
The following introduces properties, possible reasons, influences on the system and
handling procedures of all prompt events of the HSWA card.
9.1.1 CPU_INVERSION_SUCCESSFUL
Event information
Event Name Event Level
CPU_INVERSION_SUCCESSFUL Prompt Events
Possible Cause
u Switch the active and standby core switch cards via the ANM2000.
u Switch the active and standby core switch cards via the command line.
u The active core switch card is unplugged, which causes the switching occurs
between the core switch cards.
u The active core switch card is automatically and abnormally restarted, which
causes the switching in the system.
Handling Procedure
9-2 Version: D
9 Prompt Events
9.1.2 HSWA_STATUS_SWITCH
Event information
Event Name Event Level
HSWA_STATUS_SWITCH Prompt Events
Possible Cause
Handling Procedure
No handling is needed.
9.1.3 UPLINK_INVERSION
Event information
Event Name Event Level
UPLINK_INVERSION Prompt Events
Possible Cause
Handling Procedure
1. Check whether the switching for the uplink port is initiated manually:
Version: D 9-3
AN5116-06B Optical Line Terminal Equipment Alarm and Event Reference
4 If yes, ➔ Step 3.
4 If the optical module cannot receive and transmit the optical signals
normally, replace the optical module.
4 If the optical module receive and transmit the optical signals normally,
contact FiberHome for technical support.
9.1.4 SIGNAL_TRACE
Event information
Event Name Event Level
SIGNAL_TRACE Prompt Events
Possible Cause
Handling Procedure
No handling is needed.
9.1.5 TIME_REQ
Event information
Event Name Event Level
TIME_REQ Prompt Events
The equipment time is not synchronized with the NTP server time.
9-4 Version: D
9 Prompt Events
Possible Cause
The user has reconfigured the SNMP time mode in the ANM2000.
Handling Procedure
1. Click the system in the Object Tree pane and select Config→Service Config
Management in the menu bar to access the Service Config Management
window.
9.1.6 COLD_START
Event information
Event Name Event Level
COLD_START Prompt Events
The restart of the HSWA card may cause the loss of unsaved configuration.
Possible Cause
u When no standby card is in the system, the HSWA card is unplugged and then
it is inserted again.
Handling Procedure
No handling is needed.
Version: D 9-5
AN5116-06B Optical Line Terminal Equipment Alarm and Event Reference
9.1.7 TIME_ACK
Event information
Event Name Event Level
TIME_ACK Prompt Events
Possible Cause
Handling Procedure
No handling is needed.
9.1.8 HG_REGISTER
Event information
Event Name Event Level
HG_REGISTER Prompt Events
Possible Cause
The home gateway adding in the resource management system of the network
operator is successful.
Handling Procedure
No handling is needed.
9-6 Version: D
9 Prompt Events
9.1.9 OLT_REGISTER
Event information
Event Name Event Level
OLT_REGISTER Prompt Events
Possible Cause
The OLT adding in the resource management system of the network operator is
successful.
Handling Procedure
No handling is needed.
9.1.10 PEER_INSERT
Event information
Event Name Event Level
PEER_INSERT Prompt Events
The event does not influence the system and only prompts the standby card to
power on.
Possible Cause
Handling Procedure
No handling is needed.
Version: D 9-7
AN5116-06B Optical Line Terminal Equipment Alarm and Event Reference
Event information
Event Name Event Level
PRECONFIG REQUEST Prompt Events
The event does not influence the system and only prompts the AN5116-06B to send
the pre-configure request of data to the ANM2000.
Possible Cause
Handling Procedure
No handling is needed.
9.1.12 LINECARD_SWITCH
Event information
Event Name Event Level
LINECARD_SWITCH Prompt Events
Possible Cause
Handling Procedure
9-8 Version: D
9 Prompt Events
4 If no, ➔ Step 2.
Caution:
Checking whether the optical module is working normally will interrupt the
service.
4 If the forced switch is executed, check whether the operation is legal. If no,
cancel the switch; if yes, no handling is needed.
9.1.13 ACTIVE_STANDBY_CARD_SYNCHRONIZING
Event information
Event Name Event Level
ACTIVE_STANDBY_CARD_SYNCHRONIZING Prompt Events
When the equipment reports this event, users cannot plug / unplug the card to
perform active / standby card switch, or the configuration data may lose,
Possible Cause
The standby card is synchonizing the configuration and status of the active card.
Handling Procedure
No handling is needed.
9.1.14 ACTIVE_STANDBY_CARD_SYNCHONIZE_FINISH
Event information
Event Name Event Level
ACTIVE_STANDBY_CARD_SYNCHONIZE_FINISH Prompt Events
Version: D 9-9
AN5116-06B Optical Line Terminal Equipment Alarm and Event Reference
Possible Cause
The synchronization of the configuration and information on the active and standby
cards is completed.
Handling Procedure
No handling is needed.
The following introduces properties, possible reasons, influences on the system and
handling procedures of all prompt events of the EC4B / EC8B / XG2B / GC4B /
GC8B card.
9.2.1 PON_PORT_PROTECTION_GROUP_STATU-
S_CHANGE
Event information
Event Name Event Level
PON_PORT_PROTECTION_GROUP_STATUS_CHANGE Prompt Events
The event does not influence the system and only prompts the status change of the
protection group of the PON port.
Possible Cause
9-10 Version: D
9 Prompt Events
Handling Procedure
No handling is needed.
9.2.2 PRE_REGISTER_FAILURE
Event information
Event Name Event Level
PRE_REGISTER_FAILURE Prompt Events
The ONU which pre-registers unsuccessfully in the PON port cannot provide
services for users.
Possible Cause
Handling Procedure
1. Test the Tx optical power of the ONU and OLT and via the PON dedicated
optical power meter and testing optical fiber to check whether the optical power
is within the normal range:
4 If the optical power is not within the normal range, replace the optical
module.
Caution:
Checking whether the optical module is working normally will interrupt the
service.
2. Test whether the physical link of the optical fiber with the optical power meter is
normal:
Version: D 9-11
AN5116-06B Optical Line Terminal Equipment Alarm and Event Reference
4 If the optical power is too low or no optical signals exist and faults occur on
the optical fiber link or optical splitter, repair the physical link of the optical
fiber.
9.2.3 PON_INVERSION_SUCCESSFUL
Event information
Event Name Event Level
PON_INVERSION_SUCCESSFUL Prompt Events
The event does not influence the system and is only a prompt that the PON port
switching is successful.
Possible Cause
u The active PON port detects that the optical signal is abnormal and stops
working. The standby PON port is in the working status.
u The service interface card is off-line and a switchover occurs between services
on the PON port..
Handling Procedure
No handling is needed.
9.2.4 PON_INVERSION_FAILED
Event information
Event Name Event Level
PON_INVERSION_FAILED Prompt Events
The switching to the standby PON port fails. If the active PON port has faults, all
users services of the PON port will be interrupted.
9-12 Version: D
9 Prompt Events
Possible Cause
Handling Procedure
1. Check whether the configuration of the OLT PON protection group is correct.
1) Click the active HSWA card in the Object Tree pane and select Config→
Service Config Management in the menu bar to access the Service
Config Management window.
The following introduces properties, possible reasons, influences on the system and
handling procedures of prompt events of ONU.
9.3.1 AUTO_UPGRADE_SUCCESS
Event information
Event Name Event Level
AUTO_UPGRADE_SUCCESS Prompt Events
Possible Cause
Version: D 9-13
AN5116-06B Optical Line Terminal Equipment Alarm and Event Reference
Handling Procedure
No handling is needed.
9.3.2 REPLACE_TYPE_MISMATCH
Event information
Event Name Event Level
REPLACE_TYPE_MISMATCH Prompt Events
The ONU cannot register to the OLT and provide services for users.
Possible Cause
When replacing the ONU, the type of the new ONU is different from that of the ONU
to be replaced.
Handling Procedure
Note:
9.3.3 PHYSIC_ADDRESS_REPLACE_SUCCESSFUL
Event information
Event Name Event Level
PHYSIC_ADDRESS_REPLACE_SUCCESSFUL Prompt Events
9-14 Version: D
9 Prompt Events
The event does not influence the system and is only a prompt that the ONU is
replaced successfully.
Possible Cause
The ONU is replaced and registered in case it has faults or needs replacement.
Handling Procedure
No handling is needed.
9.3.4 SN_REPLACE_SUCCESS
Event information
Event Name Event Level
SN_REPLACE_SUCCESS Prompt Events
The event does not influence the system and is only a prompt that the ONU is
replaced successfully.
Possible Cause
The ONU is replaced and registered in case it has faults or needs replacement.
Handling Procedure
No handling is needed.
9.3.5 ONU_REPLACE_SUCCESSFUL
Event information
Event Name Event Level
ONU_REPLACE_SUCCESSFUL Prompt Events
Version: D 9-15
AN5116-06B Optical Line Terminal Equipment Alarm and Event Reference
Possible Cause
Handling Procedure
No handling is needed.
Note:
9.3.6 ONU_REPLACE_EVENT
Event information
Event Name Event Level
ONU_REPLACE_EVENT Prompt Events
Possible Cause
Handling Procedure
No handling is needed.
9-16 Version: D
9 Prompt Events
9.3.7 REPLACE_REPLY_FAILED
Event information
Event Name Event Level
REPLACE_REPLY_FAILED Prompt Events
Possible Cause
After the ONU is replaced, the ANM2000 fails to report the operation to the resource
management system.
Handling Procedure
No handling is needed.
9.3.8 EQUIPMENT_TYPE_CHANGE
Event information
Event Name Event Level
EQUIPMENT_TYPE_CHANGE Prompt Events
Possible Cause
Users replace the succeeding equipment connected with the ONU LAN port and the
equipment type changes.
Handling Procedure
No handling is needed.
Version: D 9-17
AN5116-06B Optical Line Terminal Equipment Alarm and Event Reference
9.3.9 EQUIPMENT_ALARM
Event information
Event Name Event Level
EQUIPMENT_ALARM Prompt Events
The ONU fails to register and fails to provide services for users.
Possible Cause
Handling Procedure
9.3.10 SELF_TEST_FAILURE
Event information
Event Name Event Level
SELF_TEST_FAILURE Prompt Events
The ONU fails to register and fails to provide services for users.
Possible Cause
Handling Procedure
9-18 Version: D
9 Prompt Events
9.3.11 ONU_AUTH_SUCCESS
Event information
Event Name Event Level
ONU_AUTH_SUCCESS Prompt Events
Possible Cause
Handling Procedure
No handling is needed.
9.3.12 ONU_DEAUTH_SUCCESS
Event information
Event Name Event Level
ONU_DEAUTH_SUCCESS Prompt Events
The ONU cannot work normally and cannot provide services for subscribers.
Possible Cause
Handling Procedure
No handling is needed.
Version: D 9-19
AN5116-06B Optical Line Terminal Equipment Alarm and Event Reference
9.3.13 DISCONNECT
Event information
Event Name Event Level
DISCONNECT Prompt Events
Possible Cause
Handling Procedure
2. Click the AD32 / VD24 card in the Object Tree pane and select Config→
Service Configuration Management to access the Service Configuration
Management window. Select Get Information→DSL Port Status Information
in the Menu Tree pane to view the Operation Status item.
4 If the window shows Data or Low Power Mode status, please contact
FiberHome for technical support.
3. Click the ETH card in the Object Tree pane and select Config→Service
Configuration Management to access the Service Configuration
Management window. Select Get Information→DSL Port Status Information
in the Menu Tree pane to view the Operation Status item.
9-20 Version: D
9 Prompt Events
9.3.14 CONNECT
Event information
Event Name Event Level
CONNECT Prompt Events
Possible Cause
Handling Procedure
No handling is needed.
9.3.15 MAC_SPOOFING_ATTACK
Event information
Event Name Event Level
MAC_SPOOFING_ATTACK Prompt Events
Possible Cause
A user accesses illegally the Internet via the other user's MAC address.
Handling Procedure
No handling is needed, and the AN5116-06B will handle the event automatically.
Version: D 9-21
Product Documentation Customer Satisfaction Survery
Thank you for reading and using the product documentation provided by FiberHome. Please take a moment to
complete this survey. Your answers will help us to improve the documentation and better suit your needs. Your
responses will be confidential and given serious consideration. The personal information requested is used for
no other purposes than to respond to your feedback.
Name
Phone Number
Email Address
Company
To help us better understand your needs, please focus your answers on a single documentation or a complete
documentation set.