Thank you for selecting our heat-pump water heater. Please read this manual carefully before
use to avoid damage of the product or occurrence of other accidents due to wrong operation.
-1-
Executive Standards:
GB 4706.1 Safety of household and similar electrical appliances: General requirements
GB 4706.32 Safety of household and similar electrical appliances-Particular
requirements for heat-pumps, air-conditioner and dehumidifier
GB/T21362 Heat-pump water heater for commercial & industrial and similar application
Please read this manual first in order to install and use the product correctly.
The heat-pump water heater can only be installed by professionals. Users shall not
install the product on their own.
Please strictly follow this manual during installation of heat-pump water heater.
Connect the heat-pump water heater to the power supply only after it is installed and
passes inspection.
In case of improvement of the machine, the contents of this manual may be subject
to change without notice.
Note: After properly installing the heat-pump water heater, the installation staff shall explain
the correct method to use and maintain the product to the users according to this manual and
-2-
ask the users to carefully read and properly keep this manual.
Power Requirements
The power supply shall be properly connected to ground wire. Please do not change
the wiring of power supply at will.
Wiring tasks must be conducted by electrician with formal qualification.
All wiring tasks shall comply with electrical safety specification.
Favorable grounding of heat-pump water heater must be ensured. To be specific,
the switch of heat-pump water heater must be provided with reliable ground wire.
Separately power supply complying with rated parameters shall be provided for
heat-pump water heater. The fusing current of its fuse must be same as that of the switch.
Note:
Do not disconnect or dismantle ground wire of power line under any circumstances.
Do not use damaged power line or switch. Power line and switch shall be replaced
immediately if damaged.
Instructions to Safety
Please read this manual carefully before use of heat-pump water heater. Please ask
the seller for help if you have any difficulty or question.
This heat-pump water heater is designed to provide you with proper hot water. It
shall be only used for the purpose described in this manual.
Never use or store gasoline or other combustible gases and liquids aside the heat-
pump water heater.
Do not use the main power switch to start or shut the heat-pump water heater. Please
provide an operable switch.
Do not fill any object at the air outlet of heat-pump water heater to avoid personal
injury.
Do not let children play the heat-pump water heater.
Attentions to Operation
Please check if the air inlet and exhaust grilles are blocked by certain objects before
startup and operation of the machine.
-3-
This heat-pump water heater is designed according to the following service
conditions: Ambient temperature: -10-43℃; hydraulic pressure: 0.1-0.7Mpa.
If the heat-pump water heater is used on occasions beyond the abovementioned
service conditions, malfunction may be caused.
Please check if the supply pressure of tap water reaches 0.1-0.6Mpa. If water in
water tank on the roofing is used instead of tap water, please ensure that the diameter of
water inlet pipe complies with the requirement. Besides, water shall be taken from the
water tank separately to ensure water supply volume.
-4-
Usage and Operation
-5-
Wire remote button definition
In number 1 blink, press timer on key enter 1 couple, The hour parameter begins
When the hour parameter is ok,press timer on key again, the min parameter begins
When the hour parameter is ok, press timer on key again, enter setting shutdown
time, method as above.
When the timer on parameter is ok, press the timer on keys again, confirm the time
of the power timing, and enter the second couple power button to set, and back to main
interface.
Under the timer on interface,Long press 5 seconds “Timer on” key can cancel
In the main interface, if no operation last 30seconds, then will confirm the setting
time in the present.
-7-
In the main interface, Press on/off key, then confirm the setting time and back to
main interface.
Cooler model
When the present is swimming pool mode, Press”+” can modify heating and
cooling model
Forced defrosting
Enter the boot model, Long press 5 seconds “-”to forced defrosting-ü Long
press“power”key, after power off esc forced defrosting, or defrosting time parameter
attachment to H5 Model can esc forced defrosting
Long press 3 seconds “timer on” key, can on/off Manually Electrical Heating
Purging history fault operation, Under the history fault interface, Long press 5 seconds
“on/off” and “+” keys, purging history fault.
-8-
L4 cooler water setting temperature 12℃
8℃~28℃
- 10 -
Maintenance and Cleaning
Before maintenance of heat-pump water heater, the machine shall be shut down and
disconnected from power supply first. When it is not used, the power supply shall be cut and
the switch shall be disconnected.
Please do not use gasoline, essential oil, solvent and other chemical drugs or liquid
insecticide on the heat-pump water heater. Otherwise, the parts of the machine would be
cracked or deformed.
Installation Steps
Drill mounting holes in relevant positions on the beam column of ground where thermal
insulation water tank is installed. Then, punch in expansion bolt, and use wrench to turn the
nut to ensure that it expands and firmly contacts with the ground. Then, install the thermal
insulation water tank and use the nut for tightening. Use the same method to install windproof
fixed rope and lightning protection device.
The unit is installed aside the thermal insulation water tank. Align the drainage nozzle of
the unit at the drainage exit beneath the chassis of the unit and then screw it in and rotate it by
90℃. Connect drain pipe and lead the condensate water of the unit to the drain pipe.
Connect the water inlet pipe of the unit with the tap water pipe; connect the return water
pipe of the unit with the return water opening of thermal insulation water tank; connect the
water outlet pipe of the unit with the water inlet of thermal insulation water tank.
Check if filter is installed at water inlet and return water opening of the unit and ensure
that the water circulation system of the unit is not blocked.
Connect the power connecting lines of the unit with users’ dedicated power switches as
per U, V, W, N and E.
Connect the water level control line of the unit to the thermal insulation water tank and
regulate the position of high water level switch based on the water volume needed. If you need
to check different water levels in thermal insulation water tank from the water level indication
of operation panel, please connect water level detection line and switch according to the wiring
diagram.
Test Run
After completion of all installation tasks, the machine must be started to conduct test run.
Before operation, electrical safety inspection must be conducted. Connect to the power supply,
touch functional switches on the operation panel, and properly set up each parameter according
to users’ demands. The unit starts to run three minutes later. Observe if the unit runs normally,
hear the running sound of unit to see if it is stable, and observe if each parameter in the display
screen is normal.
- 12 -
Repair
When your heat-pump water heater cannot function normally, please shut down the power
supply immediately. then, you may get contact with the distribution store where you purchase
the machine or customer technical service department of our company and request for repair.
Please never repair the machine on your own at will.
Troubleshooting
- 13 -
properly installed.
Fault of controller Repair or replace
Leakage of refrigerant Refill
The evaporator is dirty. Clean
- 14 -
Wiring Diagram
N
3
N
2
N
1
N KA
P
N
L
soft starter
soft starter
N start
N start
KM2 comp-R KM1
comp-R
KM-6 com
KM-6 com
S C S C
M F M F
M C R M C
1~ 1~
R
PE PE
PE PE
MP
KM1
switch KM2 KA
AC-N
OUT9 OUT8 OUT7 OUT6 OUT5 OUT4 OUT3 OUT2 OUT1
compressor RESYCLE WATER RETURN inpour COPRESSOR SUPPLY FWV compressor
COM2 W-L W-M W-H COM IN1 IN2 IN3 IN4 IN5 IN6 IN7 IN8 IN9 IN10
2 PUMP TANK WATER water HEAT WATER 1 prepare
high HEAT VALVE valve PUMP prepare
low
fan fan
speed water pressure switch
speed
transformer prepare
primary
prepare
EEV1 EEV2 low pressure switch2
ON DIP low pressure switch1
phase high pressure switch2
phase 1 2 3 4 5 6 7 8
T11
water level com
CURRENT1 CURRENT2 T1 T2 T3 T4 T5 T6 T7 T8 T9 T10
communicate
current1 current2 water outlet coil1 coil2 exhuast exhuast suction suction embient return prepare connect
tank\ water temp. temp 1temp. 2temp. 1temp. 2temp. temp. water
inlet temp. temp.
water
temp.
- 15 -
Attention:
Our company shall not be liable for any consequence resulting from any printing error
in this manual. Please refer to the product nameplate before purchase. The technical
parameters mentioned above are only for the purpose of reference. Differences resulting from
product updating will not be further notified.