You are on page 1of 38

®

HPV310 PROPORTIONAL DIRECTIONAL VALVES

Technical Catalogue
January
2018

web edition
®

HPV 310

General
Optimised performances and integration of the greatest number of functions are the objectives planned and achieved
through the development of the HPV valves, a range of the latest generation of proportional directional valves that per-
form two simultaneous functions: directional control and flow control that is unaffected by load variations. Their op-
eration is based on the proportional hydraulic principle, e.g. keeping pressure loss constant through a variable section.

The HPV spool can assume an infinite number of positions making the crossing areas infinitely variable, thus regulating
the flow in relation to the pressure difference ('p) throughout the entire operating range. By means of logical selec-
tion, an LS signal (feedback) is taken from the highest pressure ports and sent to the
pump flow regulator through the LS port so thath when a main spool is activated the pump regulator well adjust the
displacement, so thath, the set different pressure between P and LS is mainteined.

The pressure compensation provided by the two-way pressure compensators installed on each element, allows multi-
ple operations to be performed at the same time without reciprocal effects.

With HPV proportional directional valves program Dana Brevini is committed to supplying products that meet the ever
encreasing demands to suit different market applications.

© 2018 Dana Brevini S.p.A. all rights reserved. Hydr-App, SAM Hydraulik, Aron, Brevini Hydraulics, BPE Electronics,
VPS Brevini, OT Oiltechnology, logos are trademarks or are registered trademarks of Dana Brevini S.p.A. or other
companies Dana in Italy and other countries.
The technical features supplied in this catalogue are non binding and no legal action can be taken against such mate-
rial. Dana Brevini will not be held responsible for information and specifications which may lead to error or incorrect
interpretations. Given the continuous technical research aimed at improved technical features of our products, Dana
Brevini reserves the right to make change that are considered appropriate without any prior notice. This catalogue
cannot be reproduced (in while or in part) without the prior written consent of Dana Brevini. This catalogue supersedes
all previous ones.
Use of the products in this catalogue must comply with the operating limits given in the technical specifications. The
type of application and operating conditions must be assessed as normal or in malfunction in order to avoid endange-
ring the safety of people and/or items..

IE/HPV310/03-2017 1
®

HPV 310

Mineral oil hydraulic fluids


All mineral oil fluids are more or less suitable for use.
The properties required for such fluid include:
• high viscosity index
• low yield point
• high thermal stability
• high hydrolytic stability (minimum formation of corrosive phenomena inthe presence of water)
• excellent anti-wear, anti-corrosion and demulsification properties.
The requirements described above are generally met by the normal mineral oil fluids designated as HPL and HVLP
according to DIN 51524.

Ecological hydraulic fluids


Considering the minimum requirements according to DIN 51524, the HPV can also be used with vegetal oil hydraulic
fluids HGT (cole or rape oil) without particular precautions. Vegetal-based fluids can be mixed with mineral oils;
however, it should be recalled that if the oil is changed, only the part consisting of the vegetal oil is biodegradable.
The polyglycol biodegradable oils HPG or synthetic phosphoric ester biodegradable fluids HPDR can be used with the
HPV, replacing the usual gaskets with those made with FPM (Viton).
Therefore, when ordering, we recommend to indicate the use of the HPV with these types of synthetic fluids. It should
also be pointed out that the synthetic fluids cannot be mixed with mineral oils.

Hydraulic fluid filtering


It has been widely demonstrated that efficient hydraulic equipment operation depends to a great extent on the degree
of contamination of the circulating oil.
Today, users require hydraulic plants to have:
• high performances
• operation precision
• sensitive controls
• reduced maintenance expenses without giving up extended plant service life.
Carefully considering these requirements, it can be understood that specific filtering measures are needed with high-
quality filtering elements to satisfy such conditions.
The maximum degree of contaminations for particles tolerated in HPV proportional directional calves cannot be great-
er than contamination class 9 according to NAS 1638 (20/18/15 according to ISO 4406). This required contamination
class is generally achieved using filters with a retention capacity of ß20 t 100.
Our experience suggests that a pressurised filter with a nominal rating of nominal 20 μm [787 μin] or absolute 10 μm
[394 μin] is suitable to maintain the required oil cleaning parameters. In addition, it is always recommended to use
pressurised filters with a clogging indicator.
The HPV are equipped with some built-in filters which are not suitable to filter the oil of the entire hydraulic circuit,
but only some pilot lines order to protect some important components of the HPV against large-sized contaminating
particles. The internal filters of the load sensing line and the low-pressure line are easy to replace and are available
as spare parts.

2 IE/HPV310/03-2017
®

Technical features

HPV310 General characteristics


• Pressure compensated flow control;
• Excellent flow control;
• High repeatibility accuracy;
• Low hysteresis:
• Built in general pilot oil supply;
• Energy saving
• Built in pump overflow system (working in progress, not available yet);
• Different spool interchangeable variants;
• Open loop PWM electrical activation;
• Closed loop electrical actuation (0÷10 V - 0÷20 mA - 0.5 Udc signal ,
working in progress, not available yet);
• Manual / hydraulic spool control;
• Flow control spool;
• Motion control spool (working in progress, not available yet);
• Up to 5 working sections;
• Hybrid composition with HPV group valves.

HPV310 Hydraulic features


The hydraulic features reported below were measured using a mineral based hydraulic oil according to DIN 51524 or ISO 6743/4 with a
viscosity of 25 mm2/s [130 SUS] at a temperature of 50 °C [122 °F]
HSE inlet section, P port
600 l/min 159 US gal/1’
Rated flow Mid inlet section, HFLS
A, B ports 550 l/min 145 US gal/1’
Pressure relief valve setting 400 bar 5800 psi
P port
Working pressure 370 bar 5370 psi
A, B ports 370 bar 5370 psi
Max. working pressure
Y port to tank
Static 25 bar 363 psi
T port
Dynamic 35 bar 508 psi
Max. pilot pressure oil supply up to 30 bar up to 428 bar
Recommended -30 ÷ 60 °C -22 ÷ 140 °F
Oil temperature Min. -25 °C -13 °F
Max. +80 °C +176 °F
Ambient temperature -30 ÷ 60 °C -22 ÷ 140 °F
Recommended 12 ÷ 80 mm²/s 65 ÷ 366 SUS
Viscosiy Min. 4 mm²/s 39 SUS
Max. 460 mm²/s 2090 SUS
Filtering class 9 according to NAS 1638 (20/18/15 according to ISO 4406)
Spool stroke ± 9 mm ± 0.354 in
Stroke
Proportional ± 7.5 mm ± 0.295 in
Dead band ± 1.5 mm ± 0.059 in
Without anti-shock valves 98 cm³/min 5.98 in³/min
A, B oT
Nominal internal leakage With anti-shock valves 115 cm³/min 7.02 in³/min
HPV 310 internal (easy replacement) filters, mesh 100 μm
Mineral oil hydraulic fluid: according to DIN 51524 and 51525 or ISO 6743/4
HPV 310 can also be used with phosphorous esters (HFDR), water-glycol /HFC) or water-oil (HFB) mixes, subject to our Technical Dept.
approval.

Hydraulic operation
Start 5 bar 72 psi
Pilot pressure
End stroke 19 bar 275 psi
Max. pilot pressure 30 bar 436 psi

IE/HPV310/03-2017 3
®

HPV310, hydraulic features


Q A/B Spool size 10 Q A/B Spool size 40
GPM l/min GPM l/min
400 500
100
120
350 14 bar 14 bar
400
80 300 100
10 bar 10 bar
250 7.5 bar 80 300 7.5 bar
60
200
60
200
40 150
40
100
20 100
20
50
spool spool
0 0 stroke 0 0 stroke
0 10 20 30 40 50 60 70 80 90 100 % 0 10 20 30 40 50 60 70 80 90 100 %

380 530 650 mA 380 530 650 mA

7 12.5 19 bar 7 12.5 19 bar

Q A/B Spool size 70


GPM l/min
600
14 bar
140
500
120 10 bar
100
400 7.5 bar

80 300 Spool flow characteristics


60
200
40
100
20
spool
0 0 stroke
0 10 20 30 40 50 60 70 80 90 100 %

380 530 650 mA

7 12.5 19 bar

Q A/B
GPM l/min
450
110
400
100
90 350
80
HEM oil flow with LS A/B pilot
300
70 relief valves
250
60 (pressure compensated)
50 200

40 150
30
100
20
10 50

0
P
0
0 25 50 75 100 125 150 175 200 225 250 275 300 325 350 bar

0 50 100 150 200 250 300 350 400 450 500 PSI
DP
PSI bar
25

300
20

P A (B)
15
200
HEM pressure drop
B(A) T
10

100
5

Q
0 0
0 50 100 150 200 250 300 350 400 450 500 l/min

0 10 20 30 40 50 60 70 80 90 100 110 120 130 GPM

4 IE/HPV310/03-2017
®

HPV310 configuration
HPV310 module selection chart, basic and hybrid configuration (mit inlet plus HPV77 - HPV41)

MHFP

HPV41 HCF MHPOD


HSIF
HPV77 MHPH
MHOXA
HPV77+HPV41 MHPXA

HSC
HSRR
HEAS INTF

HEM HETS

HEAD
CRP04HP
(n.a.)

HSE HESC
HDRM
CRP04HP
(n.c.)

HEAD

HETS

INTF
HFLS
HCF

MHFK
MHCP

HPV41
HPV77
HPV77+HPV41

HSIF to HPV41 HSIF to HPV77 HSIF to HPV77+HPV41


HSRI00770**** + HSRI00410**** HSRR00770**** HSRI00770**** + HSRI00410****

HCM HCM HCM

HCM
HSC000410**** HSC000770**** HSC000410****

HEM000410****
HSIF HEM000410****
HEM000770****

HSIF
HSEF007705041 HSEF007705041

HEM000770****
HSIF

HFLS to HPV41 HFLS to HPV77 HFLS to HPV77+HPV41


HEM000770****
HSEF007705041 HEM000770****

HFLS HFLS HSC000770****


HFLS HSEF007705041
HEM000410****

HSC000410**** HEM000410****

HSC000410****
HCM
HCM

HCM
HSRR00770****
HSRI00770**** HCM
+ HSRI00770****
HSRI00410**** +
HSRI00410****

HPV41and HPV77, see catalogue code DOC00079

IE/HPV310/03-2017 5
®

HSE inlet module (for LS or constant pressure pumps)

Inlet section

• Built in pilot pressure relief valve;


• System with LS variable displacement pumps;
• System with constant pressure variable displacement pumps;
• Built in central pilot oil supply;
• Solenoid LS unloading valve;
• P port gauge connection;
• T port gauge connection.

Code Description
HSE0003101012 Inlet module for LS or constant pressure pumps

T Ls Tp Lp T P
Example with HSE inlet modu-
le for LS variable displacement
CVR06 pumps with LS open not plugged
Lp

W1
MT 1 P
W2
KEC25MP

Ls
KEL25
MP
MP

T Ls Tp Lp T P
Example with HSE inlet mo-
dule for constant pressu-
CVR06
Lp re systems with LS plugged
(HSE0003101010)
W1
MT 1 P
W2
KEC25MP

Ls
KEL25
MP
MP

6 IE/HPV310/03-2017
®

HSE inlet module (for LS or constant pressure pumps)

Plug or solenoid valves for HSE module position 1


Pos. Code Description Symbol
Kit with closing cover for CRP04 and W1
HESC003103015 threaded holes

High pressure piloted operated solenoid valve


CRP04HPNAAELP31 normally open 14VDC
1 High pressure piloted operated solenoid valve
CRP04HPNAAEMP31 normally open 28VDC
High pressure piloted operated solenoid valve
CRP04HPNCAEL001 normally closed 14VDC
High pressure piloted operated solenoid valve
CRP04HPNCAEM001 closed closed 28VDC
For CRP04HP with different voltages see catalogue “Cartridge valves / In-line valves” code DOC00044

M12x1.75-6H 107 [4.21]


= =
[0.78]
20

[1.57]
[1.043]

40
26.5

main pressure reducing


valve adjustment W2 15 30 W1
1/4" BSPP 13 [0.59] [1.18] 1/4" BSPP 13
main pressure relief
LP valve adjustment
1/4" BSPP 13
58 [2.28] 79,2 [3.12]
69 [2.72]

T PORT
SAE 1" 1/2
3000 psi

CRP..
236,5 [9.31]

max 85
230 [9.05]

MT
1/4" BSPP 13

MP
1/4" BSPP 13
LS MP
1/4" BSPP 13 1/4" BSPP 13

40 200 [7.87]
[1.57]
245 [9.64]
284 [11.18]

P PORT
SAE 1" 1/4 82 [3.22]
6000 psi
100 [3.96]

mm [inches]
[1.57]
40

IE/HPV310/03-2017 7
®

HSE inlet module (for fixed displacement pumps)

Inlet section

• Built in pilot pressure relief valve;


• System or fixed displacement pumps;
• Built in central pilot oil supply;
• Solenoid LS unloading valve;
• P port gauge connection;
• T port gauge connection.

Code Description
HSE0003101310 Inlet module for fixed displacement pumps
If connected with HPV41 or HPV77 proportional valves use only
HPV41 or HPV77 special elements code HEM00S*** (S identify ele-
ments without cap on LS line).

T Ls Tp Lp T P

Example with HSE inlet module


CVR06
Lp for fixed displacement pumps
MT P

W1
W2

1
Y=T

LS
Z1=LS
Ls
X=P KEL25
MP
AP
MP

8 IE/HPV310/03-2017
®

HSE inlet module (for fixed displacement pumps)

Plug or solenoid valves for HSE module position 1


Pos. Code Description Symbol
Kit with closing cover for CRP04 and W1
HESC003103015 threaded holes

High pressure piloted operated solenoid valve


CRP04HPNAAELP31 normally open 14VDC
1 High pressure piloted operated solenoid valve
CRP04HPNAAEMP31 normally open 28VDC
High pressure piloted operated solenoid valve
CRP04HPNCAEL001 normally closed 14VDC
High pressure piloted operated solenoid valve
CRP04HPNCAEM001 closed closed 28VDC
For CRP04HP with different voltages see catalogue “Cartridge valves / In-line valves” code DOC00044
20 [0.78]

107 [4.21]
= =
W1
1/4" BSPP
13
[1.57]

M12x1.75-6H
40
26.8 [1.05]

LP
1/4" BSPP 15 [0.59] 30 [1.18] W2
13 1/4" BSPP
13
58 [2.28] 79.20 [3.12]
T PORT
1" 1/2
SAE 3000 psi
69 [2.71]

MP
1/4" BSPP
236 [9.29]
230 [9.05]

13
MT
1/4" BSPP
13

LS
1/4" BSPP
13

55 [2.16] 200 [7.87]


260 [6.29] Cavity for:
- CRP04HP
320 [12.59] - HSET

main pressure reducing


valve adjustment 82 [3.22]

KEC 25 MP cap with 3-way mm [inches]


compensated prear. for CRP04HP
100 [3.93]

[1.57]
40

P PORT
1" 1/4
SAE 6000 psi

IE/HPV310/03-2017 9
®

HFLS mid inlet module (for LS or constant pressure pumps)

Mid inlet section

• For hybrid assembling with HPV 77 and /or HPV 41;


• Built-in pilot pressure relief valve;
• System with LS variable displacement pump;
• System with constant pressure variable displacement pump;
• Built-in central pilot oil supply;
• Solenoid LS unloading valve;
• P port, gauge connection;
• T port, gauge connection.

Code Description
Mid inlet module for LS or constant pressure pum-
HFLS003101212 ps

T Ls Tp Lp T P
Example with HFLS inlet modu-
le for LS variable displacement
CVR06
Lp
pumps with LS open not plugged

W1
MT 1 P
W2
KEC25MP

Ls
KEL25
MP
MP

T
T Ls Tp Lp T P

T Ls Tp Lp T P

Example with HFLS inlet mo-


CVR06 dule for constant pressu-
Lp
re systems with LS plugged
(HFLS003101210)
W1
MT 1 P
W2
KEC25MP

Ls
KEL25
MP
MP

T
T Ls Tp Lp T P

10 IE/HPV310/03-2017
®

HFLS mid inlet module (for LS or constant pressure pumps)

Plug or solenoid valves for HSE module position 1


Pos. Code Description Symbol
Kit with closing cover for CRP04 and W1
HESC003103015 threaded holes

High pressure piloted operated solenoid valve


CRP04HPNAAELP31 normally open 14VDC
1 High pressure piloted operated solenoid valve
CRP04HPNAAEMP31 normally open 28VDC
High pressure piloted operated solenoid valve
CRP04HPNCAEL001 normally closed 14VDC
High pressure piloted operated solenoid valve
CRP04HPNCAEM001 closed closed 28VDC
For CRP04HP with different voltages see catalogue “Cartridge valves / In-line valves” code DOC00044

46.5 46.5
n. 2 [1.83] [1.83]
M12x1.75-6H 107 [4.21]
[0.78]
20

45

main pressure reducing


valve adjustment
main pressure relief
W2 W1 valve adjustment
LP 1/4" BSPP 13
1/4" BSPP 13 1/4" BSPP 13

58 [2.28] 79,2 [3.12]


69 [2.72]

T PORT
SAE 1" 1/2
3000 psi

CRP..
236,5 [9.31]

max 85
230 [9.05]

MT
1/4" BSPP
MP 13
1/4" BSPP
LS
1/4" BSPP

40 200 [7.87]
[1.57]
240 [9.45]
279,2 [10.99]

P PORT
SAE 1" 1/2
6000 psi
100 [3.96]

mm [inches]

IE/HPV310/03-2017 11
®

HFLS mid inlet module (for fixed displacement pumps)

Mid inlet section

• For hybrid assembling with HPV 77 and /or HPV 41;


• Built-in pilot pressure relief valve;
• System for fixed displacement pumps;
• System with constant pressure variable displacement pump;
• Built-in central pilot oil supply;
• Solenoid LS unloading valve;
• P port, gauge connection;
• T port, gauge connection.

Code Description
HFLS003101310 Mid inlet module for fixed displacement pumps
If connected with HPV41 or HPV77 proportional valves use only
HPV41 or HPV77 special elements code HEM00S*** (S identify ele-
ments without cap on LS line).

HPV310 interface
T Ls Tp Lp T P

CVR06
Lp
MT P Example with HFLS inlet module
W1 for fixed displacement pumps
W2

1
Y=T

LS
Z1=LS
Ls
X=P KEL25
MP
AP
MP

T Ls Tp Lp T P
HPV77 interface

12 IE/HPV310/03-2017
®

HFLS mid inlet module (for fixed displacement pumps)

Plug or solenoid valves for HSE module position 1


Pos. Code Description Symbol
Kit with closing cover for CRP04 and W1
HESC003103015 threaded holes

High pressure piloted operated solenoid valve


CRP04HPNAAELP31 normally open 14VDC
1 High pressure piloted operated solenoid valve
CRP04HPNAAEMP31 normally open 28VDC
High pressure piloted operated solenoid valve
CRP04HPNCAEL001 normally closed 14VDC
High pressure piloted operated solenoid valve
CRP04HPNCAEM001 closed closed 28VDC
For CRP04HP with different voltages see catalogue “Cartridge valves / In-line valves” code DOC00044
20 [0.78]

107 [4.21]
= =
W1
1/4" BSPP
13

main pressure reducing


valve adjustment
[1.57]

M12x1.75-6H
40
26.8 [1.05]

LP
1/4" BSPP 15 [0.59] 30 [1.18] W2
13 1/4" BSPP main pressure relief
13
58 [2.28] 79.20 [3.12] valve adjustment
T PORT
1" 1/2
SAE 3000 psi
69 [2.71]

MP
1/4" BSPP
236 [9.29]
230 [9.05]

13
MT
1/4" BSPP
13

LS
1/4" BSPP
13

55 [2.16] 200 [7.87]


260 [6.29] Cavity for:
- CRP04HP
320 [12.59] - HSET

82 [3.22]
100 [3.93]

mm [inches]
[1.57]
40

P PORT
1" 1/4
SAE 6000 psi

IE/HPV310/03-2017 13
®

HEM module
Working section
• Built-in adjustable pressure compensator
• Symmetrical distribution that allows the manual activation position to be
reversed with all servocontrols
• Built-in adjustable pilot operated shock-suction valves
• Interchangeable spools
• LS and LSA/B pilot connections
• LSA/B pilot relief valves
6 5 4 • LS and LSA/B electrical unloading (work in progress, not available yet)
• Electrical actuation
MHPF, PWM signal, open loop control
MHPOD, 0-10 V, 0-20 mA, 0,5 UDC signal, open loop control
MHPED, 0-10 V, 0-20 mA, 0,5 UDC signal, closed loop control
2 (work in progress, not available yet)
3
• Mechanical flow adjustment
7
Code Description
Working section with holes LsA-B for electrical
8
HEM0003103010 unloading plugged

A 7 8
T
2 3 LsB Pos. Description Type Page
Ls 1 Spool Complements 11
B LsA
2 Shock valve or plug Complements 12
3 Shock valve or plug Complements 12
4 Manual actuation or flange Complements 13
4 5 Adapter interface Complements 16
1 6 Control Complements 17
6 7 Adapter interface (bottom side) Accessory 22
5
4 LSA / LSB / LS electrical unloading
8 Accessory 23
P1 signal (bottom side)

T Ls Tp Lp T P
[0.55]

LS pilot signal
14

125 [4.92]
BSPP 1/4”
[1.14]
29

20
LSA pilot connection
BSPP 1/4” T connection
[0.59]

127 [5]
15

200 [7.87] LSB pilot connection


BSPP 1/4”
246 [9.68]
249 [9.80]

230 [9.05]

[2.36]
60

307 [12.08] 41 [1.61]


26.5 [1.04]

312 [12.28]
A PORT B PORT
SAE 1" 1/4 60[2.36] 80[3.14] 60[2.36] SAE 1" 1/4
6000 psi 6000 psi
pressure compensator
adjustment
100 [3.93]

adjustable LSA pilot


50 [1.96]

pressure relief valve


mm [inches]
adjustable LSB pilot
pressure relief valve

14 IE/HPV310/03-2017
®

HEM complements
HEAS - Main spool for flow control, double acting (position 1)

Symmetrical distribution that allows the manual activation position to be re-


versed with all servocontrols

Flow range
Spool type Code Size 'p [bar] Symbol
[l/min]
HEAS003104200 05 8 ÷ 14 180 ÷ 270
B A
4-way, 3-position HEAS003104225 10 8 ÷ 14 250 ÷ 320
01N
A, B closed HEAS003104240 40 8 ÷ 14 310 ÷ 410
T P T

HEAS003104265 70 8 ÷ 14 410 ÷ 500

HEAS003104300 05 8 ÷ 14 180 ÷ 270


B A
4-way, 3-position HEAS003104325 10 8 ÷ 14 250 ÷ 320
03N
A, B o T HEAS003104340 40 8 ÷ 14 310 ÷ 410
T P T

HEAS003104365 70 8 ÷ 14 410 ÷ 500

A 7 8
T
2 3 LsB

Ls
B LsA

Example with HEAS0031042..


spool
4
1
6 5
4
P1

T Ls Tp Lp T P

A 7 8
T
2 3 LsB

Ls
B LsA

Example with HEAS0031043..


spool
4
1
6 5
4
P1

T Ls Tp Lp T P

IE/HPV310/03-2017 15
®

HEM complements
HEAD - Shock and suction valve for A – B ports (position 2-3)

HEAD is designed to absorb shock effects only. Don’t use it as a pressure


relief valve.

Code Description
HEAD003101450 Shock and suction valve. Setting up to 400 bar

A 7 8
T
2 3 LsB

Ls
B LsA

Example with HEAD.. valve

4
1
6 5
4
P1

T Ls Tp Lp T P

HETS - Plug for position 2 and 3

Code Description
HETS003103000 Plug

A 7 8
T
2 3 LsB

Ls
B LsA

Example with HETS.. plug

4
1
6 5
4
P1

T Ls Tp Lp T P

16 IE/HPV310/03-2017
®

HEM complements
HDRM - Manual activation (position 4)

HDRM manual actuations operate on the basis of direct operated pressure


reducing valves.
HDRM control devices basically comprise a control lever, two pressure reduc-
ing valves and a housing.
When the control lever is deflected, as a result of the interaction with the
two pressure reducing valves the relevant pilot pressure is a function of the
control lever position, enabling a highest metering spool control

Code Description
Manual actuator for electric control without spool
HDRM003107001 stroke limiter
Manual actuator for electric control with spool
HDRM003107002 stroke limiter
Manual actuator for manual control without spool
HDRM003107003 stroke limiter
Manual actuator for manual control with spool
HDRM003107004 stroke limiter

A 7 8
T
2 3 LsB

Ls
B LsA

Example with HDRM003107001


PB
for electric control (on position
4 6) without spool stroke limiter
1
PA

6 5
4
P1

T Ls Tp Lp T P

A 7 8
T
2 3 LsB

Ls
B LsA

Example with HDRM003107002


PB for electric control (on position
4 6) with spool stroke limiter
1
PA

6 5
4
P1

T Ls Tp Lp T P

IE/HPV310/03-2017 17
®

HEM complements
HDRM - Manual actuation (position 4)

A 7 8
T
2 3 LsB

Ls
B LsA

Example with HDRM003107003


PB
for manual (on position 6) wi-
4 thout spool stroke limiter
1
PA

6 5
4
P1

T Ls Tp Lp T P

A 7 8
T
2 3 LsB

Ls
B LsA

Example with HDRM003107004


PB for manual control (on position
4 6) with spool stroke limiter
1
PA

6 5
4
P1

T Ls Tp Lp T P

°
25,72 98 [3.85]

Max. stroke 3,7°


Start delivery pressure 19.5 [0.76]
P1
[ ]
*
155.5 [6.12]

271 [10.66]
115.5 [4.54]

3.5
[0.13]

59 32.5
[2.32] [1.27]
Spool stroke limiter

90 [3.54] 3.5 [0.13] mm [inches]


* = PB with standard right HPV feed
PA for left HPV feed

18 IE/HPV310/03-2017
®

HEM complements
HCF - Flange with stroke limiter (position 4)

Code Description
HCF0003104010 Flange with stroke limiter
HCF0003104011 Flange without stroke limiter

A 7 8
T
2 3 LsB

Ls
B LsA

Example with HCF.. (on position


4) with spool stroke limiter
4
1
6 5
4
P1

T Ls Tp Lp T P

0.39
10
93 [3.66]

76 [2.99]

98 [3.85] 76 [2.99]

Spool stroke limiter


30 [1.18]

[1.18]
32
[0.11]
3

mm [inches]

IE/HPV310/03-2017 19
®

HEM complements
INTF - Adapter for controls (position 5)

Code Description
INTF003105015 Adapter for controls

A 7 8
T
2 3 LsB

Ls
B LsA

Example with INTF (on position


5)
4
1
6 5
4
P1

T Ls Tp Lp T P
112.5 [4.42]
108 [4.25]

76 [2.99]

98 [3.85] 76 [2.99]
80

mm [inches]

20 IE/HPV310/03-2017
®

HEM complements
MHPF - Control (position 6)

Code Description
MHPF003107050 12 VDC control
MHPF003107051 24 VDC control

A 7 8
T
2 3 LsB

Ls
B LsA

Example with MHPF.. control (on


position 6)
4
1
6 5
4
P1

T Ls Tp Lp T P
164 [6.45]
108 [4.25]

47 [1.85] 67 [2.63]

mm [inches]

IE/HPV310/03-2017 21
®

HEM complements
MHPOD - Control (position 6)

Code Voltage Description


MHPOD03108077 12 VDC
Input signal control 0.5 x UDC
MHPOD03108075 24 VDC
MHPOD03108082 12 VDC
Input signal control 0 ÷ 10 VDC
MHPOD03108084 24 VDC
MHPOD03108086 12 VDC
Input signal control 0 ÷ 20 mA
MHPOD03108088 24 VDC

A 7 8
T
2 3 LsB

Ls
B LsA

Example with MHPOD.. control


(on position 6)
4
1
6 5
4
P1

T Ls Tp Lp T P

118 [4.64] 47 [1.85]


182 [7.16]

mm [inches]

22 IE/HPV310/03-2017
HEM complements
®

ATEX - Control (position 6)


ATEX Code Voltage Description
MHOXAB3107381 12 VDC ATEX Electro-hydraulic On/Off module
MHOXAB3107380 24 VDC double acting
MHPXAB3107181 12 VDC ATEX Electro-hydraulic proportional
MHPXAB3107180 24 VDC module double acting

A 7 8
T
2 3 LsB

Ls
B LsA

Example with ATEX control (on


position 6)
4
1
6 5
4
P1

T Ls Tp Lp T P
71.5 [2.81]

179.5 [7.06]
110 [4.33]

6 [0.23]

20 [0.78] 49 [1.92] 5 [0.19]

98 [3.85] 74 [2.91]
~ 88.7 [3.49]

20 [0.78]

mm [inches]

IE/HPV310/03-2017 23
®

HEM complements
MHPH - Control (position 6)

Code Description Thread Made


MHPH003104601 Hydraulic activation BSPP
Aluminium
MHPH003104602 Hydraulic activation UN - UNF
MHPH003104621 Hydraulic activation BSPP
Cast iron
MHPH003104622 Hydraulic activation UN - UNF

A 7 8
T
2 3 LsB

Ls
B LsA

Example with MHPH.. control


LP (B)
(on position 6)
LP (A) 4
1
6 5
4
P1

T Ls Tp Lp T P

PA - BSPP 1/4”

28 [1.10] 47 [1.85]
108 [4.25]

PB - BSPP 1/4”

mm [inches]
PB with standard right HPV feed
PA for left HPV feed

24 IE/HPV310/03-2017
®

HEM complements
HCF - Flange (position 6)

Code Description Made


HCF0003104587 Aluminium
Rear cover flow adjustement
HCF0003104584 Cast iron

A 7 8
T
2 3 LsB

Ls
B LsA

Example with HCF..


(on position 6)
4
1
6 5
4
P1

T Ls Tp Lp T P

47 [1.85] 52 [2.04]
108 [4.25]

6 [0.23] 26[1.02] 20 [0.78]

mm [inches]

IE/HPV310/03-2017 25
®

HEM accessories
INTF - Adapter (position 7)

Code Description
INTF003104005 Adapter

A 7 8
T
2 3 LsB

Ls
B LsA

Example with INTF.. control


(on position 7)
4
1
6 5
4
P1

T Ls Tp Lp T P
98 [3.85]

200 [7.87]
30 [1.18]

28 [1.10]

25 [0.98]

25 [0.98]

mm [inches]

26 IE/HPV310/03-2017
®

HEM accessories
MHFO - Unloading electrical modules LSA/B signal (position 8)
LSA / LSB pilot signal unloading solenoid valve.
- Normally open: the on/off solenoids are not energized, there is no flow on A/B
work ports;
- Normally closed: the on/off solenoids are energized, there is no flow on A/B work
ports;
while the pressure in the open will be equal to the P o T unloading pressure value on
the inlet section, plus the counterpressure acting on T line.
In closed centre circuits (under the same operating conditions) the pressure will be equal
to the stand-by pump pressure.

Code 12VDC Code 24VDC Description


MHFO007706205 MHFO007706210 Active on LSA - Normally open
MHFO007706215 MHFO007706220 Active on LSB - Normally open
MHFO007706225 MHFO007706230 Active on LSA + LSB - Normally open
MHFO007706300 MHFO007706305 Active on LS - Normally open
MHFO007706235 MHFO007706240 Active on LSA - Normally closed
MHFO007706245 MHFO007706250 Active on LSB - Normally closed
MHFO007706255 MHFO007706260 Active on LSA + LSB - Normally closed
MHFO007706310 MHFO007706315 Active on LS - Normally closed
CRP04HP, see catalogue “Cartridge valves / In-line valves” code DOC00044

Normally closed Normally open


A 7 8
T
2 3 LsB

Ls
B LsA

Example with MHFO..


4 (on position 8)
1
6 5
4
P1

T Ls Tp Lp T P

293 [11.535]

90 [3.54] 113 [4.44] 90 [3.54]

98 [3.85]
39 [1.53]
76 [2.99]

98 [3.85]
24 [0.94]
55 [2.16]

36 [1.41]

45 [1.77]

mm [inches]

IE/HPV310/03-2017 27
®

HEM accessories
MHCP - Unloading electrical modules LS signal (position 8)

Code Description
MHCP007706210 Active on LSA - 24VDC
MHCP007706220 Active on LSB - 24VDC
MHCP007706230 Active on LSA + LSB - 24VDC
MHCP007706305 Active on LS - 24VDC
XP3, pressure relief valve, see catalogue “Valves and electronics” code P35030200

A 7 8
T
2 3 LsB

Ls
B LsA

Example with MHCP..


4 (on position 8)
1
6 5
4
P1

T Ls Tp Lp T P

278 [10.94]

23 [0.91] 169 [6.65]


35 [1.37]
22 [0.86]

86 [3.38]
55 [2.16]

mm [inches]

28 IE/HPV310/03-2017
®

HSC module
End section

Code Description
HSC0003105005 No ports
P1 port - SAE 1” ¼ - 6000 psi
HSC0003105010 T1 port - SAE 1” ½ - 3000 psi
Ls1 port - BSPP ¼” - depth 13

Directly to tank Directly to tank


No ports With ports
Tp1 Ls1 Tp1 T1P1
1 1

T Ls Tp Lp T P T Ls Tp Lp T P

CSRV cartridge for HSC module


Pos. Code Description Symbol
CSRV007701203 Port 1/4” BSPP
1
CSRV007701206 Port SAE 7/16” UNF

n°2
12.5x22
50 [1.96]

CSRV cartridge
23 154 [6.06]
25 [0.98]

[0.91]
249
230

200 [7.87]
206.5 [8.12]
50 [1.96]
68.8 [2.71]

mm [inches]

IE/HPV310/03-2017 29
®

HSIF interface for HPV77


Interface between HPV310 and HPV77

Code Description
HSIF003105037 Interface HPV310 - HPV77

HPV 77 side
P T Lp Tp LS T

P T Lp Tp LS T

HPV 310 side


50 [1.96]

n°2
M14x2 22
25 [0.98]

23 154 [6.06] 23
[0.9] [0.9]
200 [7.87]
230 [9.05]

75 [2.95]

30 IE/HPV310/03-2017
®

HSRR stay bolts kit

Stay bolts kit for HPV310 elements

Tightening
Code Elements Description
torques
HSRR003105551 1
HSRR003105552 2
HSRR003105553 3
Stay bolts kit M14x1.5 140 ± 5 Nm
HSRR003105554 4
HSRR003105555 5
HSRR003105556 6

IE/HPV310/03-2017 31
®

HPV310 hydraulic diagram for constant pressure pump system

A
LsB

Ls

B LsA

P1
T Ls Tp Lp T P

CVR06
Lp
P
W1
MT
W2
KEC25MP

Ls
MP KEL25

MP

T Tp Lp T P

Ls P1 P

LsA
Ls
LsB
B

Ls P1 P

LsA
Ls
LsB
B

Ls P1 P

LsA
Ls
LsB
B
PA
PB
A

CSRV004101203

32 IE/HPV310/03-2017
®

HPV310 hydraulic diagram for LS variable displacement pump

Directly to tank
Tp1

LP (B)

LP (A)

P1

PB

PA

P1

PB

PA

P1

PB

PA

P1

CVR06
Lp
P
W1
MT
W2
KEC25MP

Ls
KEL25
MP
MP

IE/HPV310/03-2017 33
®

Note

34 IE/HPV310/03-2017
®

Code DOC00061 - Rev. 05

Dana Brevini S.p.A.


Via Luciano Brevini 1/a
42124 Reggio Emilia
Tel. +39 0522 270711
Fax +39 0522 270660
www.dana.com/brevini
info@brevinifluidpower.com