Da Db is the absolute value of the outside diameter difference, expressed in millimeters (inches).
8.10.1 Coil/plate end welds shall not be present in finished longitudinal seam pipe.
8.10.2 For finished helical seam pipe, junctions of coil/plate end welds, and helical seam welds shall be
at least 300 mm (12.0 in.) from the pipe ends.
8.10.3 If agreed, coil/plate end welds in helical seam pipe may be present at the pipe ends, provided that
there is a circumferential separation of at least 150 mm (6.0 in.) between the coil/plate end weld and the
helical seam at the applicable pipe ends.
8.10.4 Coil/plate end welds in finished helical seam pipe shall have been:
b) inspected to the same acceptance criteria as specified for the helical seam weld.
8.11 Jointers
8.11.2 Welded jointers shall be made in accordance with the requirements of Annex M.
8.11.3 No pipe used in making a jointer shall be less than 1.5 m (5.0 ft) long.
8.11.4 Portions of pipe used in the making of jointers shall have passed inspection, including hydrostatic
testing. Alternatively the completed jointer may be hydrostatically tested.
8.13 Traceability
8.13.1 For PSL 1 pipe, the manufacturer shall establish and follow documented procedures for
maintaining:
a) the heat identity until each related chemical tests is performed and conformance with the specified
requirements is shown;
b) the test-unit
unit identity until each related mechanical tests is performed and conformance with the
specified requirements is shown.