WALL FINISH SCHEDULE GENERAL NOTES:

1. ALL DIMENSION ARE IN MILLIMETER AND LEVELS ARE METERS U.O.N.


SERIAL NO. CODE DESCRIPTION 2. DO NOT SCALE THE DRAWING.
3. THIS DRAWING IS TO BE READ IN CONJUNCTION WITH THE
OTHER DRAWING.

GYPRO GA1
STEEL ANGLE

CHW SHAFT
1.36m²
GARBAGE RM

FIRE LOBBY
SERVICE ELEVATOR T2-AP1 T2-HP1
PRESSURIZATION
LOBBY
0.85m²

MECH SHAFT
CORRIDOR
SMOKE MAKE-UP GARBAGE CHUTE 1.53m²
CLOSET GAS RISER
METER 0.29m²
WATER

FHC
STAIR
PRESSURIZATION CORRIDOR
SMOKE EXHAUST
1.86m²

T2-AP2
T2-HP2

T2-AS3
STAIR
PRESSURIZATION

1.86m²

T2-AS1(F)
T2-AS1(F)

FHC
T2-AP3
T2-HP3
MECH SHAFT

3.14m²

P-P- T2-AS2
T2-AS2

HS3

K.O.T.
HS3

GYPRO MF7 PRIMARY ELV SHAFT

100
P-
P- ELEC ROOM
LINEN CHUTE RM
LINEN CHUTE

HS4
HS4
TEL / IT ROOM JANITORS CLOSET

SUPPORT CHANNEL
T2-OP2
T2-OP2 T2-OP1
T2-OP1

CH2900 (AFFL)
10

PT 7 TOWER 2 - LEVEL 2
12.5 THK. GYPSUM BOARD KEYPLAN
WITH OFF WHITE PAINT
MATTE FINISH

3 3
1351 1351 KEY PLAN:

12MM THK. CEMENT


BOARD
ST 4
CREMA VENATO MARBLE
G.I. HOR. STUD RIVETED
4
WALL POLISHED FINISH
INTO VERT. STUD

T2 T1
ST 4
CREMA VENATO MARBLE
WALL POLISHED FINISH

3 BLOW-UP DETAIL REVIEW STATUS

15
1:5
CONCEALED LED A APPROVED

90
LIGHT
PT 7 PT 7 C REJECTED
PAINT FINISH
PAINT FINISH

15
15 20 120 60 15
COORDINATION TABLE
500

500
5MM THK. STONE 5 5
ADHESIVE 5MM THK. STONE Arch. Coord. ACC
ADHESIVE
ST 4 5MM X 5MM
CREMA VENATO MARBLE STONE GROOVE
WALL POLISHED FINISH
G.I. HOR. STUD RIVETED G.I. HOR. STUD RIVETED
INTO VERT. STUD INTO VERT. STUD 15MM THK. PLASTER
5MM THK. STONE
1000

FINISH Subcontractor
ADHESIVE
COORDINATOR NAME SIGNATURE DATE

15MM THK. PLASTER 15MM THK. PLASTER ST 16 REFERENCES


FINISH FINISH 12MM THK. CEMENT VANILLA VENATO ONYX
BOARD POLISHED FINISH
VANITY TOP
500

500
ST 4
CREMA VENATO MARBLE ST 4
CREMA VENATO MARBLE TITLE DRAWING NO.
WALL POLISHED FINISH
WALL POLISHED FINISH 37
SUBMITTAL
5MM X 5MM 5MM X 5MM

700
STONE GROOVE G.I. HOR. STUD RIVETED
STONE GROOVE INTO VERT. STUD
12 5 20 ST 4
CONCEALED LED CONCEALED LED CREMA VENATO MARBLE
LIGHT LIGHT

5 15 5
WALL IN THE SIDE
MT 11 POLISHED FINISH
AB FOR APPROVAL 28-08-19 BL BL
METAL INSERT
ST 4 REV. PURPOSE OF ISSUE DATE PREPARED CHECKED
CREMA VENATO MARBLE
WALL IN THE SIDE ST 4
POLISHED FINISH CREMA VENATO MARBLE
AS BUILT
700

700
ST 4 CISTERN TOP TANK COVER
CREMA VENATO MARBLE POLISHED FINISH
2900

WALL POLISHED FINISH


PROJECT NAME & LOCATION:

ST 16 ST 16
240
200
6 VANILLA VENATO ONYX
POLISHED FINISH
240
200
6 VANILLA VENATO ONYX
POLISHED FINISH
200 3
CH1200 (AFFL)
THE ADDRESS RESIDENCE
1351 VANITY TOP 1351 VANITY TOP SKY VIEW

20
REMOVABLE
4 BLOW-UP DETAIL 1:2 5 DUBAI, U.A.E.
100

G.I. HOR. STUD RIVETED 200 15 20


Parcel ID - 3457562 Community - Burj Khalifa
200

INTO VERT. STUD G.I. HOR. STUD RIVETED 240


INTO VERT. STUD
CLIENT:
G.I. HOR. STUD RIVETED
BH 4002 INTO VERT. STUD
CONCEALED CISTERN
EMAAR
ST 4 ST 4 ST 4 PROPERTIES P.J.S.C.
CREMA VENATO MARBLE CREMA VENATO MARBLE CREMA VENATO MARBLE
WALL POLISHED FINISH WALL POLISHED FINISH WALL POLISHED FINISH
BH 4002 PROJECT MANAGER:
4 BH 4004 4 BH 4004
CONCEALED CISTERN
ST 4
1200

1351 HAND SPRAY 1351 HAND SPRAY


CREMA VENATO MARBLE
WALL POLISHED FINISH
1000

MT 11 MT 11
925

12MM THK. CEMENT


METAL INSERT METAL INSERT
BOARD LEAD CONSULTANT: P.O. Box 53150
Dubai, U.A.E.
12 5 20 info.international@norr.com
BH 4001 BH 4005 5MM THK. STONE
650

Tel: 04 354 4439


600

Fax: 04 354 4900


WATER CLOSET URINAL ADHESIVE
ST 4 ARCHITECTS ENGINEERS PLANNERS P.O. Box 44387
ST 3
410

Abu Dhabi, U.A.E.


CREMA VENATO MARBLE
390

ST 3 ST 3 PERLADO GRIGIO MARBLE


NORR Group Consultants info.international@norr.com
CISTERN TOP TANK COVER
20

International Limited Tel: 02 676 3360


PERLADO GRIGIO MARBLE PERLADO GRIGIO MARBLE FLOOR HONED FINISH 5 Fax: 02 676 3361
POLISHED FINISH
FLOOR HONED FINISH FLOOR HONED FINISH
5

MAIN CONTRACTOR:

5
G.I. HOR. STUD RIVETED

15
100

INTO VERT. STUD


SCREED SCREED
75

240 240
SCREED

CONCRETE SLAB CONCRETE SLAB SUB CONTRACTOR:

5 5
CONCRETE SLAB
fino I N T E R N A T I O N A L
Interior Finishing Contractors
P.O.Box: 261946 Dubai - U.A.E., Tel. 04 8802663 Fax 04 8802661
email:info@finointeriors.com
1351 1351
DRAWING TITLE:

CONCRETE SLAB TOWER 2 - LEVEL 2


LOBBY LOUNGE/TOILET DETAIL
(WATER CLOSET & URINAL)
DRAWING No.: Rev.:
SV-FNO-ID-T2-L02-AB-1351 AB
1 SECTIONAL 1:10 2 SECTIONAL 1:10 5 BLOW-UP DETAIL 1:2 6 BLOW-UP DETAIL 1:5 SCALE: AS SHOWN SHEETS: 1/1 DRG. SIZE: A1