1) Stability Calculation ( CASE -1 WIND ACTS FROM Outside )

a) Check for Overturning


Calculation of overturning moment about "0"

a Load coming from The Surcharg(T1) 1x 20 x 0.3 6.6 Kn/m 6.6 KN


(Assuming 1.0mts surchrage from out side.)

b Vechile Load on Surchrge Out side (T2) 1x 20 0.3 6 Kn/m 6 KN


( live load for light vechile)
c Wind load from out side(T3)
Assuming 1.0Kn/m2 wind load acting from outside
1 x 5x 4 20 KN
( span)
Load mkdLoad (kN) Distance(m) Mo (kNm)
T1 6.6 0.85 5.61

T2 6 0.85 3.26

T3 20 2.55 51

Total 32.6 KN 59.87 KNM

b Calculation of Restoring moment about "O"

a Load coming from The Surcharg(L1) 0.6 x 18 x 2.4 x 1.4 36 kn


Surcharge on Foundation

b Load coming from The Surcharg(L2) 0 kn

b Self Weight of Concerte ( L3)

Footing 2.4 x 1.4 x 0.5 x 24 40 KN

Grade Beam 0 x 0.2 x 0.4 x 24 0 KN

Column 4 x 0.3 x 0.5 x 24 14.4 KN

Tie Beam 0 x 0.2 x 0.4 x 24 0 KN

Wall 4 x 0.2 x 1.2 x 24 23 KN


Page 2 of 5

78 KN

Load mkdLoad (kN) Distance(m) Mro(kNm)

L1 36.288 1.2 43.5456

L2 0 0.0 0

L3 77.76 1.2 93.312

Total 117.4 kN 136.9 kNm

Total Overturning Moment Mo = 59.87 kNm


Total Restoring Moment Mro = 136.9 kNm

Factor of Safety= Mro/Mo = 136.8576 / 59.87 = 2.28 > 1.5 Safe !!

c) Check for Bearing pressure

Breadth b = 2.4 mts 1.4 Mts


C.g of Load x = (Mro-Mo)/P = 0.6558
eccentricity e = B/2 - x = 0.5442

Load coming on Footind P = 117 Kn

fbmax = P/A(1 + 6.e/B) = 82.475 kPa

fbmin = P/A(1 - 6.e/B) = -12.6 kPa


Page 3 of 5

2) Design of base slab

cDesign of Toe Slab


Thickness at base slab t1 = 500 mm
Diametre of the bar used db = 14 mm
Clear cover to the main bar c = 50 mm
Effective depth de = 443 mm
Moment at face of theColumn = f4*b12/2 = 59.3817857 kNm
Design moment = 1.6.M Mu = 95.0108571 kNm
Rmz = Mu/(bd )
2
= 0.48413422 N/mm2

% steel r = f.fc 1 - 1 - 2.Rmz = 0.00102693 > 0.0018


fy f.fc
Hence Ast = 0 = 797.4 mm2
Spacing of dia bar = 193.049962 mm
Provide F 14dia @ 150mmc/c

Check for shear


Shear at d from face of columnl V = (f4).(b1-de) = 82.4747024 kN
Design shear stress vu = 1.6 V/(bd) = 9.4257E-05 N/mm2
All. shear stress vc = f. fc / 6 = 0.77594029 N/mm2 Safe!!

2) Design of Column ( as cantilever Beam )

cDesign of Column
Thickness 300 x 500 t1 = 300 mm
Diametre of the bar used db = 14 mm
Clear cover to the main bar c = 25 mm
Effective depth de = 268 mm
Design Moment 60 kNm
Design moment = 1.6.M Mu = 95.792 kNm
Rmz = Mu/(bd2) = 2.1287111111 N/mm2

% steel r = f.fc 1 - 1 - 2.Rmz = 0.00467617 > 0.0018


fy f.fc
Page 4 of 5

Hence Ast = 0 = 626.606797 mm2


No of Main bars at one side 4 Nos 14 dia 615.44 mm2

Check for shear


Shear at d from face of columnl V = = 150 kN
Design shear stress vu = 1.6 V/(bd) = 0.0016 N/mm2
All. shear stress vc = f. fc / 6 = 0.77594029 N/mm2 Safe!!