Protective measures in electrical systems For the most part, this involves testing in
are intended to prevent bodily injury due to accordance with VDE 0100 (IEC 60364), VDE
accidents involving electrical current. 0105 (EN 50110) and VDE 0113 (EN 60204)
Of course they also prevent property damage regulations.
caused by electrical power as well. And thus The tests themselves are executed by the
every electrical system should be checked with instruments strictly in accordance with stipula-
our test instruments before initial start-up, and tions set forth in particular by VDE 0413
at regular intervals thereafter, in order to (EN 61557).
assure the effectiveness of installed protective
measures.
transfer
GOSSEN METRAWATT
46 Testers: DIN VDE 0100 – 600 / IEC 60364-6 Table of Contents
in Germ
de a
Ma
ny
GOSSEN METRAWATT
Table of Contents Testers: DIN VDE 0100 – 600 / IEC 60364-6 47
MBASE
MXTRA
MTECH
MPRO
Characteristics / Features
allows for data entry via the RS 232 port
with the help of a barcode or RFID
RCD measurements reader. This unique function assures
UB measurement without tripping the RCCB n n n n maximum operating convenience for
Tripping time measurement n n n n creating and expanding tree structures
Tripping current measurement n n n n (customers, buildings, distributors etc.),
Selective, SRCDs, PRCDs, types A, AC, G/R and F n n n n searching for designations or IDs,
AC/DC sensitive RCDs, type B, type B+ — n — n navigating through various modes,
Testing of insulation monitoring devices (IMDs) — — — n creating test texts, inspection and trial
Testing of residual current monitoring devices (RCMs) — — — n tests, creating defects lists and much
Testing for N-PE reversal n n n n more. Data processing, measurement
and visual inspection can be executed
Loop impedance ZL-PE / ZL-N immediately without reconfiguring plugs
Fuse table for systems without RCDs n n n n or switches – the basis for meaningful
Without tripping the RCD, fuse table — n — n documentation.
With 15 mA test current* without tripping the RCD n n n n
Earth resistance RE
I-U measuring method, mains operation
n n n n
(2/3-wire measuring method via measuring adapter: 2-wire/2-wire + probe)
Earth resistance RE (battery operation) 3 or 4-wire measuring method via PRO-RE adapter — — n n
Soil resistivity rE (battery operation)
— — n n
4-wire measuring method via PRO-RE adapter
Selective earth resistance RE (mains operation) with 2-pole adapter, probe, earth
n n n n
electrode and current clamp sensor (3-wire measuring method)
Selective earth resistance RE (battery operation)
with probe, earth electrode and current clamp sensor — — n n
(4-wire measuring method via PRO-RE adapter and current clamp sensor)
Earth loop resistance RELOOP (battery operation) with 2 clamps (current clamp sensor
— — n n
direct and current clamp transformer via PRO-RE/2 adapter)
Measurement of equipotential bonding RLO Automated Test Sequences
Automatic polarity reversal n n n n Automated test sequences can be
generated from manually created
Insulation resistance RISO
individual measurements with the help of
Variable or rising test voltage (ramp) n n n n
the test sequence function. A test
Voltage measurement sequence consists of individual steps,
UL-N / UL-PE / UN-PE / f n n n n measurements, visual inspections etc.,
Special measurements which are executed one after the other.
Leakage current (clamp measurement) IL, IAMP n n n n Measurement results obtained in this
Meter start-up n n n n way are saved correctly to the freely
Phase sequence n n n n selectable tree structure and can be
Voltage drop n n n n subsequently documented by means of
Standing-surface insulation ZST n n n n appropriate software. Test sequences
Earth leakage resistance RE(ISO) n n n n are created with the help of ETC
Leakage current with PRO-AB adapter — — — n software and are transferred to the
Residual voltage test — — — n respective test instrument (PROFITEST
Intelligent ramp — — — n MXTRA und MPRO).
Features
Selectable user interface language n n n n
Memory (database for up to 50,000 objects) n n n n
Automatic test sequence function n n n n
RS 232 port for RFID/scanner n n n n
USB port for data transmission n n n n
Bluetooth® interface — — — n
ETC user software for PC n n n n
Measuring category: CAT III 600 V / CAT IV 300 V n n n n
DAkkS calibration n n n n
* The so-called live measurement is only advisable if there is no bias current within the system.
Only suitable for motor protection switches with small nominal current.
in Germ
de a
Ma
ny
GOSSEN METRAWATT
48 Testers: DIN VDE 0100 – 600 / IEC 60364-6 Table of Contents
Profi-Package
Master Pack-
Starter Pack-
Master Pack-
TECH Starter
MEDpackage
Base Starter
E-CHECK Set
Package
Package
Testing Packages
XTRA
XTRA
XTRA
XTRA
TECH
age
age
age
Article M500M M500N M500P M500U M500V M500W M500X M500Y
Accessories
PROFITEST MBASE M520M n — — — — — — —
PROFITEST MTECH M520O — n n n — — — —
PROFITEST MXTRA M520P — — — — n n n n
Earth spike SP350 GTZ3304000R0001 — — n — — — — —
TR50 drum GTY1040014E34 — — n — — — — —
VARIO plug adapter set Z500A n n n n n n n n
PRO-RLO II adapter Z501P — — n — — n n —
PRO-AB leakage current measuring adapter Z502S — — — — — — n —
E-Clip 2 generator clamp for earthing measurements Z591B — — — — — — — n
Z3512A clamp for earthing measurements Z225A — — — — — — — n
PRO-RE 2 measuring adapter for 2-clamp measuring method Z502T — — — — — — — n
F2000 universal carrying pouch Z700D n n — — n — — —
Professional case Z502W — — n — — n n n
E-CHECK case Z502M — — — n — — — —
Rechargeable battery pack Z502H n n n n n n n n
Charger Z502P n n n n — — — —
Charger Z502R — — — — n n n n
in Germ
de a
Ma
ny
GOSSEN METRAWATT
Table of Contents Testers: DIN VDE 0100 - 600 / IEC 60364-6 49
PROFITEST I C
Article: M521A
Test Instrument for DIN VDE 0100 / IEC 60364-6
Protective measures test instrument for loop resistance measurement, calculation
of short-circuit current and display of suitable fuse ratings. In addition to complete
testing for the effectiveness of RCCBs, the instrument is also capable of phase
sequence analysis, as well as the measurement of voltage and frequency.
nR
ugged 2-component housing with nG
o / No-Go indication via LEDs, and
integral impact guard – perfect for instructions in the display
use by on-site installation teams and n Integrated phase tester
an ideal supplement to the PROFIT- nS tand, holders for test probes and
EST 204 in accordance with the new cables, and a recharging socket for
EN 60204 standard. NiCd/NiMH batteries
n L arge, illuminated, anti-glare graphic
display allows for clear, intuitive,
menu-driven operation Please refer to the data sheet for
nQ uick, easy operation with the help further technical specifications.
of just 5 keys
Incl. Factory n Integrated measured value memory
Calibration Certificate can be read out via the IrDa interface
which is included as a standard
feature.
n T he instrument can always be kept
current thanks to the update option.
nS torage of measured values with
accurate assignment to their
respective electrical circuits, distribu-
tors and buildings with the alphanu-
meric keypad
in Germ
de a
Ma
ny
GOSSEN METRAWATT