TimeSource 3100
Primary Reference Source For Public Network Service Providers
APPLICATIONS
The TimeSource 3100 system can be config-
ured as a PRS to front-end an office
SSU/SASE or as a standalone PRS with 10
outputs for remote or small offices. In the
TimeSource 3100
TimeSource 3100 Specifications ANTENNA SPECIFICATIONS
• Type: Active antenna with integrated IF downlink
GENERAL • Cable type: RG-59 with TNC connector
• Specifications: ITU-T G.811 and G.812, EN 300 462-6-1, • Cable length: Up to 300 meters without amplifier
ETSI 3017, CE • Operating temperature: -30° C to +80° C
• Internal oscillator: Digitally Controlled Ovenized Crystal Oscillator
(DCOCXO) OTHER
• Sync inputs: GPS, E1/2.048MHz (optional), or remote • Mechanical: 22 cm (H) x 45 cm (W) x 25 cm (D)
oscillator (optional) • Power: -48 VDC (redundant)
• Sync outputs: E1/2.048MHz, 10MHz, 1 PPS, TOD, ESCIU • Operating temperature: 0° C to +50° C
• Sync status messaging: Outputs and inputs • Humidity: 5% to 95% non-condensing
• Communications: RS-232,Ethernet • EMC: Compliance with FCC Part 15, Class A
• Management: TimeScan/Craft, TimeScan/NMS, TimePictra/TMN
SYMMETRICOM, INC.
2300 Orchard Parkway
San Jose, California
95131-1017
tel: 408.433.0910
fax: 408.428.7896
info@symmetricom.com ©2004 Symmetricom. Symmetricom and the Symmetricom logo are registered trademarks of Symmetricom, Inc. All specifications
www.symmetricom.com subject to change without notice. DS/TS3100/A4/0504/1M