Professional Documents
Culture Documents
Strap Footing
Strap Footing
Data
Strap footing for two square columns
axial loads of 900 kN and 1200 kN with a c/c spacing of 6m
Column A = 0.4 X 0.4 =
Column B = 0.5 X 0.6 =
Load on Column A = 900 KN
Load on Column B = 1200 KN
C/c distance between columns = 6m
distance of property line from the left face of column = 0.5 m
Bearing pressure of soil = 140 KN/m2
Assume weight of footing and earth above is 10% of the total loads carried by the columns.
Grade of Concrete = 20 Mpa
Grade of Steel = 415 Mpa
Let
Thethe width
values of footings
of B1 and be B1 and B2 respectively.
B2should be such that the C.G of the footing coincides with the C.G of the column loads.
Length of footing under A = B1 and length of footing under B= B2 centrally arranged under A and B(square footings).
= 16.5 m2
Let x distance of C.G of loads from center of column B, as given by
= 2.57 m
If x is also the distance of C.G of areas from the center of column B, we have
= 190.9091 KN/m2
A. Design of Footing Slab for Column B: Let the width of strap beam = 400 mm
Cantilever projection beyond the beam is a = =1/2 *(3.3 - .5) 1.4 m
Maximum bending moment, M = po*a /2 =2
187.0909
= 143.322651 mm
footings shall not be less than 0.12% of the total cross-sectional area (B2d).
Therefore distribution reinforcement = 950.4 mm2
Use 10 mm dia. Bars, Ab = 78.53982 mm2
Number of reinforcement bars required = 13
spacing of long bars = 253.8462 mm
Use 11 16 mm dia. Bars for longitudinal reinforcement @ 250 mm c/c.
C. Bending Moment and Shear Force Diagrams for Strap Beam:
Upward load w per meter run on the strap beams is given by
w1 = 458.1818 KN/m
w2 = 630 KN/m
Downward load of column A = w1 = 3375 KN/m
Downward load of column B = w2 = 3600 KN/m
= 2.00 m
If x is also the distance of C.G of areas from the center of column B, we have
B x L1 ( l + b1/2 - L2/2)
= B x (L1 + L2)
= 109.0909 KN/m2
A. Design of Footing Slab for Column B: Let the width of strap beam = 400 mm
Cantilever projection beyond the beam is a = 1.05 m
Maximum bending moment, M = po*a2/2 = 60.136363636 KNm
= 93.356387 mm
footings shall not be less than 0.12% of the total cross-sectional area (B2d).
Therefore distribution reinforcement = 720 mm2
Use 10 mm dia. Bars, Ab = 78.53982 mm2
Number of reinforcement bars required = 10
spacing of long bars = 250 mm
Use 11 16 mm dia. Bars for longitudinal reinforcement @ 250
C. Bending Moment and Shear Force Diagrams for Strap Beam:
Upward load w per meter run on the strap beams is given by
w1 = 272.7272727273 KN/m
w2 = 272.7272727273 KN/m
Downward load of column A = w1 = 2000 KN/m
Downward load of column B = w2 = 2250 KN/m
3.0 m
2.5 m
mm c/c.
mm c/c.
A. Data
Strap footing for two square columns
axial loads of 900 kN and 1200 kN with a c/c spacing of 6m
Column A = 0.3 X 0.3 =
Column B = 0.3 X 0.3 =
Load on Column A = 650
Load on Column B = 730
C/c distance between columns = 3.96
distance of property line from the left face of column = 0
Bearing pressure of soil = 150
Assume weight of footing and earth above is 10% of the total loads carried by the columns.
Grade of Concrete = 20
Grade of Steel = 500
Let the width of footings be B
The values of L1 and L2 should be such that the C.G of the footing coincides with the C.G of the column loads.
Length of footing under A = L1 and length of footing under B= L2 centrally arranged under A and B(square footings).
B x (L1 +L2) = 10.12 m2
Let the width of both footings be 2m
L1 + L2 = 5.06 m
Let x distance of C.G of loads from center of column B, as given by
= 1.87 m
If x is also the distance of C.G of areas from the center of column B, we have
B x L1 ( l + b1/2 - L2/2)
= B x (L1 + L2)
= 136.363636364 KN/m2
A. Design of Footing Slab for Column A/B: Let the width of strap beam = 500
Cantilever projection beyond the beam is a = 0.85
Maximum bending moment, M = po*a2/2 = 49 KNm
d= 134 mm
Keeping cover to centre of steel = 60 mm, D = 194 mm
Keep D = 220 mm so that d = 160 mm
Ast = 811 mm2
Use 16 mm dia. Bars, Ab = 201 mm2
In the range AB, shear force is zero at a distance x from outer face of column A and its value is given by
x= 2.01 m
The hogging bending moment is maximum at this section, its value given by
M1 = -658 KNm
Bending moment at the edge A is given by, x = 0.3
M2 = -85 KNm
Bending moment at the edge B is given by, x = 3.96
M3 = -338 KNm
Bending moment at the edge D is given by, x = 4.26
M3 = -306 KNm
Bending moment at the edge E is given by, x = 5.06
M3 = -284 KNm
square footings).
length L1 = 3.0 m
length L2 = 2.0 m
mm
m
0
0.3
4.26
7.68
7.98
568.1818 3.42
= 1.87 m
If x is also the distance of C.G of areas from the center of column B, we have
B x L1 ( l + b1/2 - L2/2)
= B x (L1 + L2)
= 136.363636364 KN/m2
A. Design of Footing Slab for Column A/B: Let the width of strap beam = 500
Cantilever projection beyond the beam is a = 0.85
Maximum bending moment, M = po*a2/2 = 49 KNm
d= 134 mm
Keeping cover to centre of steel = 60 mm, D = 194 mm
Keep D = 220 mm so that d = 160 mm
Ast = 811 mm2
Use 16 mm dia. Bars, Ab = 201 mm2
In the range AB, shear force is zero at a distance x from outer face of column A and its value is given by
x= 2.86 m
The hogging bending moment is maximum at this section, its value given by
M1 = -998 KNm
Bending moment at the edge A is given by, x = 0.3
M2 = -105 KNm
Bending moment at the edge B is given by, x = 3.96
M3 = -833 KNm
Bending moment at the edge D is given by, x = 4.26
M3 = -863 KNm
Bending moment at the edge E is given by, x = 5.06
M3 = -1039 KNm
square footings).
length L1 = 3.8 m
length L2 = 2.3 m
mm
m
0
0.3
4.26
7.68
7.98
698.1818 3.42