DIN 28087
( May 1994 )
TOP HEAD TYPE LIFTING LUGS
ON APPARATUS FOR MOUNTING.
Dimensions and allowable loadings.1 Field of application
DIN 28087
(DEUTSCHE NORM
Top head type fifting lugs on apparatus BINT
May 1994
for mounting 28087
Dimensions and allowable loadings
{CS 71,120.10
‘Supersedes 05.78 edition
Dimensions in mm
This standard shall be applies to top head type lifting lugs on apparatus made of
unalloyed, low-alloyed or ‘Stainless steels, which are mainly used in process
erigineering applications.
For wickined apparatus or apparatus lined otherwise, it shall be checked whether
the special requirements tor this Purpose are adequately satisfied (sce, for example,
DIN 28051, DIN 28060).
NOTE: The allowable loadings refer only to the lifting lugs themselves. The
loading capacity raking into account the apparatus wall is not analzyed here.
Dimensions, designation
General tolerances DIN. 8570-0
The lifting lug, web and reinforcing plate shall be adjusted to fit the apparatus wall
where necessary.DIN 28087
Stes}
Ent laf fungs~
% bobrungen $6.82
Tangentent inie -
Schweifnaht
Boden-Zarge
Vers tirkungsbech
Fig. 1:Top head type lifting lug; shown on cylindrical equipment
Designation of a fitting tug with nominal size 3 made of steel with material No. 1.0038,
+ 1einforcing plate and web made of steel with material No. 1.4571:
Lifting tug DIN 26087-3-1.0038-1.4871
Footnotes:
1) The weld seams shall be executed in such a way that the existing cross-section of
the web is fully joined: weld craters at the seam ends shall not be permissible.
2) Hole for thread M6; suitable closure at the discretion of the manufacturer.
3), = wall thickness of apparatus.
4)
‘The web shall be suitably adapted for use of lugs on other types of apparatus.DIN 28087
TABLE A -DIMENSIONS.
——_
house [hth >@talaytelels|e]s
UETING WE | an ou | an in, am
7 3a] 1] 40 | a6 | ass | v2] eo | 60 | wo] c| 70
2 7s |v] so| a | 46 | 155 | oo | 65 190| 60 | 100 20
[a7 | a5 | a0] 70] so | cas | ao | so | 0 | 10 | <0 | 150 30
«| 1aa| 260] 90] 62 | 765 | 265 | 160 | 65 | 220 | s10 | 200 40 :
5 tas | 310 | 100 | 74 | ens | aco | 200 | 70 | 260 | 120 [200 | 155 | 60 | 2s
‘The thickness s, of the reinforcing late stiall be selected according to the
condition; s,