Professional Documents
Culture Documents
Extinguishant
Control Panels
2
A sophisticated, dynamic LCD, which supplements the LED
status indicators, provides detailed information on panel
status including fault conditions, alarm conditions and
extinguishing release countdown. If dynamic mode is chosen,
the display changes colour in relation to the panel status,
providing immediate and clear visibility of status conditions.
These are as follows:
White – Normal condition
Red – Fire condition, Released condition
Red flashing – During countdown to the released condition
Yellow – Fault condition, Disabled condition and Test condition
Green – Access level 2
Turquoise – Access level 3
3
Application Diagram
Applications
The Sigma ZXT is particularly suitable for the following applications:
Archive Rooms Marine
Datacentres Printing and Machine Protection
Energy Centres Switch Rooms
Factories Telecomm Rooms
Generators Tunnels
Industrial Units Waste Recycling
4
Network Diagram
Manual Release
Activate Extinguisher
Low Pressure Switch
Extinguishing Control
PCB
Vizulinx
Fire alarm management
4 Core (FP200 max. length 1200m)
solution
4 Core
Addressable
House Fire Alarm
5
Sigma XT Extinguishant
Control Panel
Sigma XT panels are robust and easy to install, with all the
electronics mounted on a single, easily removable, steel plate.
Sigma XT Features
Any single zone or any combinations of zones can be
configured to release
Configurable first stage sounder delays
Configurable detection delays
Zero time delay upon manual release option
Compatible with I.S. barriers
Non-latching zone input option to receive signals from
other systems such as aspirating equipment
Countdown timer displays time remaining until release
Supports up to seven, four-wire status indicators
Approved and certified to EN12094-1, EN54-2 and EN54-4
UL and FM Approved version also available
6
Sigma XT
Connection Diagram
Manual Release
Activate Extinguisher
Low Pressure Switch
Sigma XT - EN12094-1
Approved Control Unit
Vizulinx
Fire Alarm Management
4 Core (FP200 max. length 1200m)
Solution
4 Core
Addressable
House Fire Alarm
7
Sigma XT+ Multi-Area
Extinguishant Control Panel
8
Syncro XT+ Multi-Area
Addressable Extinguishant
Control Panel
Syncro XT+ multi area addressable control panel enables Syncro XT+ features
extinguishing systems to use all the features and benefits Up to four extinguishant areas (custom build options
of the more sophisticated detection techniques provided are available)
by addressable fire detectors, as well as the other benefits Dual extinguishant outputs for each area
of analogue addressable systems, such as control of loop (configurable as main/reserve)
connected sounders, beacons and input/output modules. First and second stage sounder outputs for each area
With up to 16 zones of addressable detection over one or First and second stage volt-free changeover contacts
two loops it ensures every detector can contribute to the for each area
extinguishant release. Released volt-free contact per area
Fault volt-free contact per area
The Syncro XT+ has up to four extinguishing areas and two Programmable extinguishant delays
releasing outputs per area which can be controlled via simple Programmable output duration
coincidence detection or via more complex cause and effects Countdown indicator shows time until release in seconds
configured by the Loop Explorer configuration programme. Mode select and manual release controls per area
Each extinguishant area features a comprehensive set of Serial connections for Sigma Si status units and ancillary
inputs and outputs and is configurable via the Loop Explorer boards (K588)
configuration programme. Approved and certified to EN12094-1, EN54-2 and EN54-4
9
Syncro XT+
Network Diagram
The Syncro XT+ Multi Area Addressable Fire Alarm Control Panels are Approved to EN12094-1, EN54-2 and EN54-4 - KM 96761
Each loop is
capable of hosting
Main Release
I/O up to:
126 devices (Apollo) or
127 devices (Hochiki)
Can be
Low Pressure configured Syncro Matrix
as 1st stage Fire Alarm Mimic
sounders
(if fitted) Display System
Loop 1 Loop 2
Release Pressure 24V DC or
230V AC
Abort Unit
I/O
Syncro Ident
Programmable LED
Hold Off Unit Indication Panels
24V DC or
230V AC
Manual Release
RS485 Syncro View
Local LCD Repeater
24V DC or
230V AC
K1822
Sigma Si Weatherproof Sigma Si
Ancillary PCB Status Unit Status Unit
Syncro XT+
Multi Area Addressable K545
Up to 7 per Up to 7 per
area. area. Extinguishant Control Panel 4 Way Conventional
Zone Board 24V DC
K555
High K555
Integrity
Network Card Network Card
Required Required
K546
6 Way
Configurable Sounder Board
24V DC
Network
RS485
K547
8 Way
Relay Board 24V DC
Control panels
are supplied Up to 64 Panels
with 1 or 2 detection can be added to
Syncro XT+ loops and 16 the network.
zone indicators.
Multi Area Addressable
Extinguishant Control Panel The Syncro XT+
system is compatible
with Apollo, and Hochiki K560
protocols. Syncro XT+ Syncro XT+ 16 Channel
panels of either the above
protocols can be networked
Multi Area Addressable I/O Board
together. Extinguishant Control Panel 24V DC
Vizulinx
Fire alarm management
solution
Electronics Ltd
The Syncro XT+ Fire Alarm Control Panels are
Approved to EN12094-1, EN54-2 and EN54-4
10
Sigma Si Extinguishant
Status Units & Hold-Off Unit
Warning Signs
Powered by a nominal 24V DC supply, the illuminated
warning signs use LED technology to provide a high reliability,
high brightness, audio/visual warning indication unit to
supplement mandatory alarm warnings.
Status Unit Features
High brightness LEDs The brightness of the sign remains constant over its entire
Detailed indication of the status of the control panel operating range of 15 to 30 volts DC due to the unique ‘power
Monitored data connection boost’ circuitry employed. This ensures that even with a system
Countdown timer displays time remaining until release running on depleted batteries, all signs remain at full intensity.
Manual only, automatic and manual mode
Remote auto/manual door interlock input (monitored) A range of standard text signs are available, including
Remote hold input (monitored) automatic/manual mode, manual only mode, automatic
Internal fault diagnosis indicators model only, and extinguishant system activated. All signs
Weatherproof IP65 versions available have fully customised text and different languages are easily
Certified compliant with BS EN12094-1 when used accommodated. The large display panel is backlight with high
with Sigma XT control equipment intensity white LEDs to provide a high contrast indication
in a range of different colours.
11