You are on page 1of 2

DOUBLE COVERS EXECUTIONS

TYPE BM P.D. METER

 
Data sheet: DS/CO/0005/EN Ed. May 2012

The BM meter series in double covers execution have been


developed as alternative to the double case execution. Double
case is a typical execution for high pressure application used
instead of the single case one. High pressure may modify the
geometry of the meter case (both body and covers)
increasing the internal volume of the meter and changing the
meter accuracy. Double case, instead, has an internal
measuring chamber which volume is not modified by the
pressure because liquids flow internally and externally such
measuring chamber with same pressure on both side.
Body has less implication with high pressure, due to the geometry
and thickness of it. Main components subject to pressure
modification, thus, are the covers, flat one. To increase its
resistance against pressure have to be a different geometry
curved one or, if flat, with an higher thickness.
An alternative solution is the “double covers”.
Meters has, thus, both front and rear covers made of two covers
each, an internal and an external. The internal one allow the
liquid flow on both side of it (through the central hole) and, thus,
internal covers has same pressure inside and outside and, than, its
geometry will be not modified due to high pressure. Its
function is to allow the vanes to rotate and keep the bearings in
position. Due to the central holes the liquids occupies a small
volume between the internal and external covers, in order to
keep the geometry of such internal cover not modified. External
cover has the function to mechanical resist against the liquid
pressure.
Such “double covers” execution has recently superseded the
“double case”, since allow the same performance for pressure
until 40 bar, but with a much easier technical manufacturing of
the meter itself.

Pos. Description 
1 Body
2 Manifold
3 EM6422
4 External cover
5 Internal cover

ISOIL IMPIANTI S.p.A.- 24061 Albano S. Alessandro (BG) - Italy


tel : +39.02.91988.5 fax: +39.02.66012457
web:www.isoilmeter.come-mail: sales@isoil-impianti .it
DS/CO/00005/EN – 05/2012 Pag. 1/2
Technical specifications
STANDARD UPON REQUEST
BM 200 Double Covers BM 400 Double Covers BM 600 Double Covers

EU Directives compliance

PED (dir. 97/23/CE) Compliant directive 97/23/CE, with risk category depending on the measured liquid
Non electrical equipment, compliant directive 94/9/CE, suitable for installation in hazardous area
ATEX (dir. 94/9/CE)
II 2G, marking Ex II 2 G c T1 … T6
Working conditions
Flow rate: [100 ; 1,300] l/min @ 10 cSt [200 ; 2,400] l/min @ 10 cSt [300 ; 3,400] l/min @ 10 cSt
Maximum flow rate avio 1,400 l/min 2,600 l/min 4,000 l/min
Working pressure: 1,000 KPa max 1,000 KPa max 1,000 KPa max Higher value
Test pressure: 1,700 KPa 1,700 KPa 1,700 KPa
Working temperature: [-30; +100] °C [-30; +100] °C [-30; +100] °C Higher and lower values
Construction
Manifold and flanges: Carbon Steel Carbon Steel Carbon Steel or Aluminium (avio)
Carbon Steel with corrosion Carbon Steel with corrosion Carbon Steel with corrosion
Body:
prevention treatment prevention treatment prevention treatment
Covers Carbon Steel with corrosion Carbon Steel with corrosion Carbon Steel with corrosion
(internal and external ): prevention treatment prevention treatment prevention treatment
Rotor: Aluminium Aluminium Aluminium Stainless Steel SS316
Vanes: Graphite Graphite Graphite PTFE
Gaskets: Nitrile Nitrile Nitrile Viton or PTFE
Ball bearings: Stainless Steel Stainless Steel Stainless Steel Graphite bushes
Mechanical or magnetic
Seal: Viton lip seal Viton lip seal Viton lip seal
drive
Other sizes and
Flanged: 3’’ ANSI150 RF 4’’ ANSI150 RF 6’’ ANSI150 RF or FF (avio)
standards
Readout
litres litres or m3 m3 Others
(with mechanical register)
Flow direction: Left (IN) to right (OUT) Left (IN) to right (OUT) Left (IN) to right (OUT) Right (IN) to left (OUT)
Performances
Accuracy: ± 0.1% ± 0.1% ± 0.1%
Repeatability: ± 0.01% ± 0.01% ± 0.01%
Pressure drop: Refer to the diagram attached Refer to the diagram attached Refer to the diagram attached
Temperature range, printed on plate, will always span 60° C

Accuracy curves

+0,15
+0,1
+0,05
% ERROR

0
--0,05
BM 400
--0,1
BM 200 BM 600
--0,15

0 500 1000 1500 2000 2500 3000 3500

FLOW RATE [l/min]

ISOIL IMPIANTI S.p.A.- 24061 Albano S. Alessandro (BG) -Italy


tel: +39.02.91988.5 fax: +39.02.66012457
web:www.isoilmeter.com e-mail: sales@isoil-impianti .it
DS/CO/0005/EN – 05/2012 Pag. 2/2