You are on page 1of 5

Project:

Reference code:

Design office:

Person in charge:

Construction Office:

Person in charge:

Anchor (name) ZJE01 Wedge anchor Dimension

Article code ZJE0110090 Approval ETA 13/1012


Diameter 10, standard embedment depth

Wedge anchor in carbon steel, with nut and washer, zinc plated, ETA-CE Opt.7 certified

Tension Reinforcement
N Sd,Z 0 kN Diameter 11 mm
Distance rebars 120 mm
Shear Distance stirrups 120 mm
V Sd,X 0 kN Edge reinforcement No
V Sd,Y 6.05 kN
Anchor Plate
Bending b fixX 250 mm
b fixY 84 mm
M Sd,X 0 kNm
t fix 5 mm
M Sd,Y 0 kNm

Edge distance
Torsion C Xp 6000 mm
M Sd,Z 0 kNm C Xn 6000 mm
C Yp 75 mm
Lever arm C Yn 75 mm
No lever arm has been applied
Spacing
Concrete SX 100 mm
C20/25 Uncracked

Member height h 383 mm

2/28/2019 ZJE01 Wedge anchor page 1


Project:

Reference code:

Design office:

Person in charge:

Construction Office:

Person in charge:

Anchor/thread diameter: d 10 mm
Outside diameter of anchor: d nom 10 mm
Drill hole diameter: d0 10 mm
Depth of drilled hole: h1 75 mm
Setting depth: h nom 67 mm
Effective anchorage depth: h ef 55 mm
Diameter of clearance hole in fixture: df 12 mm
Thickness of fixture: t fix 5 mm
Spanner: SW 17 mm
Setting torque: T inst 35 Nm
Project:

Reference code:

Design office:

Person in charge:

Construction Office:

Person in charge:

Concrete

Uncracked Concrete strength C20 (20/25)

f ck = 20 MPa
f ck,cube = 25 MPa
Ψc = 1.00

Calculated Actual design loads on Anchor(s)

Tension
The forces applied to the fixture, do not cause tension in any anchors

Shear

V Sd,X = 0.00 kN V gsd = 6.05 kN


V Sd,Y = 6.05 kN α = 90.0 deg
M Sd,Z = 0.00 kNm

Distribution of shear forces if all anchors are active

V Sd anchor 1 = 3.03 kN α1 = 90.0 deg


V Sd anchor 2 = 3.03 kN α2 = 90.0 deg

Tension
No tension forces are applied to the anchor

βN 0,00
Project:

Reference code:

Design office:

Person in charge:

Construction Office:

Person in charge:

Calculation of Utilisations - Shear loads

Shear - Steel Failure Without Lever Arm

V Rk,s = 14.70 kN
γ Ms = 1.25

V Rd,s = 11.76 kN β v Steel Failure Without Lever Arm 0.26

Steel Failure With Lever Arm

No Lever Arm has been applied

Shear - Concrete Pryout Failure (group of all anchors )

V Rk,cp = 22.63 kN
γ Mc = 1.50
V Rd,cp = 15.09 kN β v Concrete Pryout Failure 0.40

Shear - Concrete Edge Failure( edge Yp)

V 0Rk,c = 12,409 N
A0 c,V = 25,313 mm2
A c,V = 36,563 mm2
Ψs,V = 1.00
Ψh,V = 1.00
Ψa,V = 1.00
Ψec,V = 1.00
Ψre,V = 1.00

V Rk,c = 17.92 kN
γ Mc = 1.50

V Rd,c = 11.95 kN β v Concrete Edge Failure 0.51


Project:

Reference code:

Design office:

Person in charge:

Construction Office:

Person in charge:

UTILISATIONS

Tension βN = 0.00 OK
Shear βV = 0.51 OK

RESULT

Ok. The product meets the design criteria

IMPORTANT NOTICE
The data input to this software, and the relative results, must be checked by the user under the responsibility of an engineer
experienced in anchorages and concrete work. This is to ensure there are no errors and all data is complete and accurate and complies
with all rules and regulations for the actual conditions and application.
The data contained in this software relates only to the product illustrated therein and is based on principles, formulas and safety
regulations according to the existing guidelines for anchorages into concrete, together with the knowledge of the manufacturer.
The user must comply with these principles. The user is solely responsible for the data entered into the program and any errors or
omissions are the responsibility of the user. The user must ensure that the most current version of the program is installed by way of
the auto-updating function offered by the manufacturer.
The user must update the program when instructed to do so.
The aim of the program is to act as a calculation aid and to assist in complying with current regulations and guidelines, without any
guarantee of suitability for any specific application.

You might also like