You are on page 1of 3
Licensed Copy: Akin Koksal, Bechtel Ltd, 10 December 2002, Uncontrotied Copy, (c) BS! EN 1008:2002 (E) 3. Classification of types of water In general the suitability of water for the production of concrete depends upon its origin. The following types may be distinguished: 3.2 Water recovered from processes in the concrete industry (This water, defined in A.2.1, will normally be suitable for use in concrete, but shall conform to the requirements of annex A. 3.3. Water from underground sources This water may be suitable for use in concrete, but shall be tested. 3.4 Natural surface water and industrial waste water This water may be suitable for use in concrete, but shall be tested. 3.5 Sea water or brackish water This water may be used for concrete without reinforcement or other embedded metal, but is in general not suitable for the production of reinforced or prestressed concrete, For concrete with steel reinforcement, or embedded metal, the permitted total chloride content in the concrete is the determining factor. 3.6 Sewage water This water is not suitable for use in concrete. 4 Requirements 4.1 General Water for use in concrete shall conform to the requirements of 4.2, 4.3.1, 4.3.2 and 4.3.3. The water shall also conform to either the chemical requirements in 4.3.4, or the requirements for setting time and compressive strength in 4. : ‘Water supplied as potable water is deemed to conform to the requirements in this standard. When waters are to be combined (see A.2.2), the requirements apply to the combined water. NOTE — Weter conforming to the European Directive O8/83/EC Is potable water and therefore considered as suitable for use In conerete. 4.2 Preliminary assessment ‘The water shall be examined in accordance withthe test procedures stated in Table 1. Water not conforming to one ‘or more of the requirements in Table 1 may be used only, ifit can be shown to be suitable for use in concrete, in accordance with 4.4. 5 oer, © L/OKU Management san. Bha. ‘97000 Bintuht, Sarawat. Tel: 086-318111 Fax: O86-314520 Our Ref. LAKU/BP/WQS 21.4/17( 79) Date 21" August 2017 FJ CONCRETE & PILES SDN BHD LOT 3632, BLOCK 26, KEMENA LAND DISTRICT KIDURONG INDUSTRIAL ESTATE P.O. BOX 2202 97011 BINTULU SARAWAK FAX: 086-253 236 Attn: Mr. Chan Peng Swan Dear Sir, REQUEST FOR “TEST REPORTS” OF WATER ‘Thank you for your letter dated 4" August 2017. We are pleased to submit herewith summary of test reports for treated water analysis for selected parameters as per National Drinking Water Quality Standards for your reference. The sampling point relevant to the location requested is at Sampling Station No.$26 Sg. Plan Housing Area. Please kindly note that the water quality results of the treated water supplied by us is tested by the Department of Chemistry to comply with the requirement of the National Drinking Water Quality Standards. The results shall not be used for any unintended purpose other than as a reference, Thank you. ‘Yours faithfully, Salemah Binifi Sapudin ACTING BINTULU AREA MANAGER Contact Officer: Ng Kok Hua Water Quality Control Executive Tel: 016-897 2106 Fax 086-332 946 Email: ngkokhua2604@gmail.com Faxed Sont on Corporate Office Miri Area Office Limbang Arca Office ‘6th Floor, Soon Hup Tower, Lot 907, ‘6 Fleer, Soot up Tower. Lat 907, Lot 850, islam Pangaran, sJalan Mera, 98000 Ni, Sars Sedan Meat, 98000 Mir Sarswale Po. Box'388, 98700 Limbang, Sarewak. TTel'085.442000 Fax: O85-442008 el 085-442000 Pex: 086-242043 “Tel: 086-215633 Fas: 088-215655 racist 20eS0 2H aay aoye a4 meg SEEN TANT

You might also like