SLAB MEMBER SCHEDULE

MEMBER REFERENCE SIZE/SPACING GRADE TREATMENT / JOINT GROUP REMARKS (TIE-DOWN, CONNECTION, ETC)
PAINT

SLAB S1 100mm N32 - - 100THK RC SLAB ON GRADE WITH SL82


TOP MESH, 40mm COVER
EDGE BEAMS EB1 300 W x 400 D N32 - - 3 N12 TOP & BOTTOM REBARS & R10-300
STIRRUPS. COVERS ALL AROUND WILL BE 45 mm
INTERNAL BEAMS IB1 300 W x 400 D N32 - - 3 N12 TOP & BOTTOM REBARS & R10-300
STIRRUPS. COVERS ALL AROUND WILL BE 45 mm
R1 140 X 45 (TOP CHORDS) MGP10 H2S JD5 @ 600 C/C TIMBER ROOF TRUSS. REFER
DWG S5 FOR FURTHER DETAILS
ROOF TRUSS (TR1) ST1 35 X 35 (INTERMEDIATE STRUTS) MGP10 H2S JD5

T1 90 X 45 (TIE MEMBER) MGP10 H2S JD5

LINTEL BEAM (LB) SCHEDULE


SPAN LB (TILE ROOF) LB (SHEET ROOF) TC

≤ 1.7 m 120 X 45 MGP 10 120 X 45 MGP 10 1 STUD

1.7 - 2.3 190 X 45 MGP 10 190 X 45 MGP 10 2 STUDS


NOTES:
1. CONCEAL FLOOR BEAMS AND TRIMMERS IN JOIST DEPTH. 2.3 - 2.8 240 X 45 MGP 10 240 X 45 MGP 10 2 STUDS
2. CONCEAL VERANDAH BEAMS IN THE ROOF.
3. TYPICALLY POSITION BEARERS AND POLE PLATES BENEATH JOISTS.
4. INSTALL JOISTS AND SUPPORTS IN ACCORDANCE WITH MANUFACTURERS SPECIFICATION.
5. BEARERS, FLOOR BEAMS AND JOISTS TO BE SUPPORTED ON TIMBER FRAME U.N.O.
6. TYPICALLY PROVIDE 4 STUDS UNDER ALL POINT LOADS U.N.O.
7. FIX POLE PLATES SUPPORTING JOISTS TO STEEL BEAMS WITH M12 BOLTS AT 450 CRS.
8. NOMINAL JOIST NOGGING BETWEEN FLOOR JOISTS SHALL BE INSTALLED IN ACCORDANCE WITH
MANUFACTURER'S SPECIFICATION. FLOOR JOISTS SHALL BE PROVIDED WITH SUPPORT AND
MIDSPAN BLOCKING IN ACCORDANCE WITH AS1684 OR MANUFACTURER'S DETAILS.
9. LINTELS NOT DESIGNED TO SUPPORT TOP HUNG DOORS U.N.O.
10. PERIMETER WALLS ARE TYPICALLY LOAD BEARING WALLS
11. DENOTES STEP TO ARCHITECTURAL DETAILS.
12. TR DENOTE TIMBER TRUSSES TO MANUFACTURERS SPEC AT 600 CRS MAX.
13. TGT DENOTES TRUNCATED GIRDER TRUSS TO MANUFACTURERS SPEC.
14. 2S DENOTES TWO STUDS.
15. 3S DENOTES THREE STUDS.
16. 4S DENOTES FOUR STUDS.
17. DJ DENOTES DOUBLE JOIST.
18. LBW DEMOTES LOAD BEARING WALL.
19. NLB DEMOTES NON LOAD BEARING WALL. NOT FOR CONSTRUCTION
20. H.D.G. DENOTES HOT DIP GALVANISED.
21. FOR FULL DESCRIPTION OF MEMBERS AND THEIR DETAILS REFER 'MEMBER SCHEDULE'.

PROJECT PROJECT NUMBER DRAWN BY DATE PRINT DATE


REVISIONS & AMENDMENTS SAFE AUSTRALIA
REV. DATE DESIGN & CONSULTING ENGINEERS PROPOSED NEW GRANNY FLAT 191107 ZH 24.12.2019 24.12.2019
DESCRIPTION
0 ISSUED FOR DISCUSSION 24.12.19
26 ABERT STREET, THE PONDS, NSW 2769

CIVIL, STRUCTURE, STORMWATER, PROJECT MANAGEMENT APPROVED BY CHECKED BY SHEET SIZE SCALE
SUITE 7, 5-7 ROSS STREET GRANVILLE, NSW 2142
PARRAMATTA, NSW 2150, Australia AN VR A3 NA
P: 02 7801 4847 DRAWING CONTENT
M: 04 3734 2436
MEMBER SCHEDULE CLIENT DRAWING No. REVISION
E: contact@safeoz.com.au AZHAR M. NASIR
www.safeoz.com.au MIEAust, CPEng, NPER, (2016938) KIA ANVARI S2 0