MEMBER SCHEDULE LEGEND

WALL DENOTES 3N12 CRACK CONTROL BAR,


W1 300 THICK RC 2000 mm LONG TIED TO UNDERSIDE
W2 250 THICK RC OF SLAB REINFORCEMENT
W3 250 THICK RC
W4 200 THICK RITEK STEP DOWN
W5 200 SERIES BLOCK
250 SLAB THICKNESS
6 7 8 9 10 11 12 BEAM (B x D)
B1 500 x 500 RC STRUCTURAL ELEMENT BELOW
7 B2 500 x 400 RC
STRUCTURAL ELEMENT ABOVE
B3 250 x 500 RC
B4 900 x 900 RC
B5 400 x 400 RC STRUCTURAL ELEMENT BELOW & ABOVE
11725 9860 11150 9700 5550 8800 B6 250 x 400 RC
B7 350 x 500 RC CJ CONSTRUCTION JOINT

N16-200 (B)

N16-200 (T)
B8 350 x 1000 RC
B9 510 x 400 RC EJ EXPANSION JOINT
4 STAIR NO.2 0.3 mm VAPOUR 0.3 mm VAPOUR B10 250 x 1200 RC
- UP DOWELLED JOINT
B2 - 500 x 400 BARRIER UNDER BARRIER UNDER B11 450 x 1550 RC DJ

400
VOID
C B2 - 500 x 400
SLAB SLAB B12 600 x 400 RC
B13 400 x 400 RC IJ ISOLATION JONT
B1 - 500 x 500
BEAM REINFORCEMENT BEAM REINFORCEMENT
500 SEE DRAWING S405 SEE DRAWING S405 STRUCTURAL STEEL SJ SAWN JOINT

500
600 SB1 150 UC 23
SB2 360 UB 45 BMT 1.0 mm BONDEK SLAB
PILE & PILE CAP PILE & PILE CAP SB3 460 UB 67
N12-200
REINFORCEMENT REINFORCEMENT SB4 530 UB 82 VOID
TRIMMER BARS AT VOID

B1 - 500 x 500

B1 - 500 x 500
600 SEE DRAWING S300 SEE DRAWING S300
8320

ALL SLAB EDGE SB5 610 UB 101


B2 - 500 x 400 SB6 700 WB 130 CONCRETE PILE
TYPICAL
4 SB7 900 WB 257
- SB8 200 PFC TOP REINFORCEMENT BARS
P1 Z15015 @ 900

B2 - 500 x 400
FB 65 x 5 EA BOTTOM REINFORCEMENT BARS
BR Ø20 ROD GRADE 250
SECTION 4 SECTION 5
250
D 200
1 : 20 - 1 : 20 - NOTES
B1 - 500 x 500
1. REFER DRAWING S100 FOR GENERAL NOTES.

*
N16 - 200 (T & B)
6380

B3 - 250 x 500
W3 UP STAIR NO.1
- N12 - 200
(T&B) F
W4 B13

W3

W3
VOID

150
B2 - 500 x 400
B13

B2 - 500 x 400
W4 BONDEK SLAB
E

200
SL102 (T)

10 600 B2 - 500 x 400 W3

150
W4
B13

-
2100

N12 - 200 VOID


W4

150 BONDEK SLAB


(T&B)
W4 W4 B2 - 500 x 400 VOID B2 - 500 x 400 W4 W4 W4
F W3
VOID
B13 IJ W2 N12-200 VOID
VOID
W4

W4

500

150
85
W3

W3

400
VOID

W4
W 250
5
IJ 150 IJ * BEAM REINFORCEMENT
W4 900 0.3 mm VAPOUR
UP W4 SLAB ON GROUND
SEE DRAWING S405
BARRIER UNDER SLAB
W3 B13 B13
REINFORCEMENT *
* SEE DRAWING S405

STAIR NO.3
B2 - 500 x 400 IJ SECTION 9
SECTION 6 1 : 20 -
B4 - 900 x 500

W4

B2 - 500 x 400

B2 - 500 x 400

B2 - 500 x 400
B2 - 500 x 400

1 : 20 -
16500

200 200 200

W4
B2 - 500 x 400 IJ
200
6
-
STAIR NO.3 6
7 150
- W4
SLAB ON GROUND
UP REINFORCEMENT 6
W4
B2 - 500 x 400
*

SEE DRAWING S405


5 IJ IJ
W4

W 250
8 85
W4

W4

-
B13 IJ W2 RL 592.00
G

200

200
W4 W4
B2 - 500 x 400

N12 - 200 B2 - 500 x 400 B2 - 500 x 400 B2 - 500 x 400 B2 - 500 x 400
2100

W4

SL102 (T)

150 (T&B) VOID


B13

W4

600

500
B2 - 500 x 400 200 200
H W4 RL 591.40
N16-200
B13

PILE & PILE CAP


REINFORCEMENT

400

400
900 SEE DRAWING S300
*

*
W4 B13 BEAM REINFORCEMENT
SEE DRAWING S405
N12 - 200 500
(T&B)
B2 - 500 x 400

B2 - 500 x 400
* *
B2 - 500 x 400

200 * * SECTION 7 SECTION 8


14700

B2 - 500 x 400
1 : 20 - 1 : 20 -

B2 - 500 x 400
B2 - 500 x 400
LAID 2ND & 3RD

VOID
* ALL SLAB REINFORCEMENT
TO BE N12-200 (U.N.O.)
4
LAID 1ST & 4TH -

150

150
B2 - 500 x 400

150
150
RL 592.00
I SLAB ON GROUND
W4
B2 - 500 x 400
4 5 RL 591.40 W4
-
-

B13 0.3 mm VAPOUR B13

150
BARRIER UNDER SLAB B13 B13
PLAN - GROUND FLOOR
SCALE 1:100 SECTION 10
1 : 40 -

SAFE AUSTRALIA CARDINAL


DESIGN & CONSULTING ENGINEERS DIRECTION
CIVIL, STRUCTURE, STORMWATER, PROJECT MANAGEMENT
SUITE 7, 8 MCFARLANE STREET
MERRYLANDS, NSW 2160, Australia
P: 02 8872 4902
M: 04 3734 2436
E: contact@safeoz.com.au
www.safeoz.com.au