Professional Documents
Culture Documents
Module
Description
The 88255-01 Intrinsically Safe Keyphasor® Transducer Interface Module (TIM)
R allows input of shaft rotative speed and phase data into the Trendmaster® 2000
System. This single-channel device acts as a Proximitor® and interfaces to
either our Bently Nevada 3300 XL 8 mm or 3300 5 mm proximity probe and
extension cable (5 metre system).
Page 1 of 5
-20°C to + 100°C (-4°F to +212°F)
Specifications
Storage
All specifications are within operating temperature Temperature:
limits, using an AISI 4140 steel target, unless
-40°C to + 100°C (-40°F to +212°F)
otherwise noted.
Humidity:
Electrical
Up to 90% relative humidity,
Keyphasor
noncondensing. Use of weather-
(88255-01): proof housing recommended for
environmental protection.
Used with a 3300 XL 8 mm probe
or Electrostatic
Discharge (ESD)
3300 5 mm probe and extension
Protection:
cable (5 metre system only).
10 kV through 1 k Ω to exposed
Notch or
surfaces.
Projection:
Vibration:
Along length of the shaft.
50 mm/s peak (2.0 in/s peak).
Minimum Width: 9.0 mm (0.35 in).
10 Hz to 1000 Hz any axis.
Minimum Depth/Height: 1.25 mm
(0.05 in). Mechanical
Near Gap Transducer
Range: Interface
Module
Probe should be set between 10 Material:
mils (250 µm) and
Polycarbonate
25 mils (625 µm) from the closer
of the two surfaces being Size
observed on the shaft. Height:
Linear Range: 77 mm (3.0 in) typical
1.25 mm (50 mils). Width:
Linear range begins at 23 mm (0.89 in) typical
approximately 0.25 mm (10 mils)
from target and is from 0.25 to 1.5 Depth:
mm (10 to 60 mils). 78 mm (3.1 in) typical
Frequency Weight:
Response:
Up to 112 g (0.25 lb)
0.1 to 600 Hz (60-36,000 cpm)
when used in the TM2000 system. Mounting:
Electrical Variety of mounting
Classification: configurations including clips for
35 mm mounting rail and two
Complies with the European CE holes for #6 (M4) screws.
mark
Electromagnetic Compatibility
Environmental Limits
Radiated
Operating Emissions:
Temperature:
EN 55022 (1994), Class A.
Specifications and Ordering Information
Part Number 141565-01
Rev. C (04/07)
Page 2 of 5
Electrostatic
Discharge:
IEC 1000-4-2 (1994), Criteria A.
Radiated Contact your nearest Sales Professional if your
Susceptibility: application involves hazardous area classifications
not listed above.
ENV 50140 (1993), Criteria A.
Conducted Patent:
Susceptibility:
5,200,743
ENV 50141 (1993), Criteria A.
Components or procedures
Electrical Fast described in this patent applies to
Transient: this product.
IEC 1000-4-4 (1994), Criteria A.
Ordering Information
Surge
Capability: All necessary connectors for transducer and cable
(line) hook-up are included with the TIM.
ENV 50142 (1994), Criteria A. 88255-01
Magnetic Field: Intrinsically safe Keyphasor
TIM
EN 61000-4-8 (1994), Criteria A.
Hazardous Area Approvals Accessories
126709-04
Class I, Groups A, B, C, and D;
Class II, Groups E, F and G; Manual
Class III; Enclosure type 4 when
installed per drawing number
86571; T4 @Ta = 100°C
Certificate number LR26744-228
Page 3 of 5
Details and Dimensions
Cable
In/Out
To R
Keyphasor
Probe
3300 XL Probe /
Extension Cable
PI PI PI PI PI PI PI PI PI PI
N 1N 2N 3N 4N 5 N 1N 2N 3N 4N 5
SI SI COP SH SI SI COP SH
G G M W LD G G M W LD
(+)(-) R (+)(-) R
Transducer
BENTLY Connection
NEVADA
MADE IN U.S.A.
PART #
88255-01
Page 4 of 5
Mounting for 35 mm
DIN Rail
78.0
(3.070)
7.11
(0.280) 76.7
66.5 (3.020)
(2.620)
22.5
(0.887)
Bently Nevada, Keyphasor, Trendmaster, and Proximitor are trademarks of General Electric Company.