Conventional Audible Visual Devices

Sounders with supplementary indicator


> Product Overview
KAC’s conventional Sounder Beacon is ideal for applications where a sounder is required as the primary method of
alarm, but a supplementary light indicator would also be of benefit. The product features a new folded horn design,
LED technology and advanced optics, providing outstanding sound output and supplementary light indication
at very low current draw. The ENscape sounder beacon delivers outstanding quality, reliability and extended
operational life, making it the ideal choice for a wide range of applications.

ENscape Sounder Beacon Benefits

> Simple, Fast, Flexible Installation Outstanding Performance


• Modern design and aesthetics eliminates the need • Approved to EN54-3 for sound.
for device orientation. • Global tone set: 32 approved tones including bell tone.
• First fix capability allows electrical continuity testing • LED technology & advanced optics provides light
prior to device fitting. indication at very low current draw.
• Deep base option with multiple cable entries for flixible • Synchronisation of flash and sound.
installations. • Red or Amber light flash
• Designed with full range of common fixing centres. • Operates on 12V and 24V systems, making the
• Positive fit engagement & feedback of base with device range suitable for use in security applications.
for easy installation.

Universal Device Quality & Reliability


• Suitable for wall and ceiling mount applications. • Independently approved to all relevant standards:
• Available in red or white body colours with red or - Manufacturing: Constructive Products Regulation (CPR)
amber lens. - Product performance: EN54-3 for sound
• Range of installation and base options, for indoor - Environmental : RoHS, WEEE
and applications up to IP65.

> Introducing the Range


Lens Environmental
Approvals Body Colour Flash Colour Installation Options
Colour Compliance
Device
Standard First Red or
EN54-23 EN54-3 Red White Red White RoHS/ WEEE
Device Fix Amber
ENscape Sounder/Indicator          

> This product is not approved to EN54-23 (Visual Alarm Device) and must not be
used as a visual alarm device to provide a primary warning notification of fire.

CAV-SIND
Rev. No.1
Sounder Beacons – Technical Specification

Electrical Specification Environmental Specification

Operating Voltage: 12 to 29 VDC Operating Temperature: -25°C to 70°C


Current consumption, average: 22mA @ 29VDC (Tone 7) Relative Humidity: 93% ±3%, non condensing
Ingress Protection: IP21C - low profile base
IP65 – deep base
Mechanical Specification For RoHS & WEEE Please visit www.kac.co.uk

Body colour: Red / White


Sound Output, maximum: 107dB(A) @1m (Tone 23) Dimensions
Number of Tones: 32 and includes a bell tone.
Full tone table available on website & installation manual
Volume setting: High or medium
Synchronisation: Automatically at power on
Cable Terminal Size: 0.5 - 2.5mm²
Material Lens/Body: Flame retardant PC/ABS
Gross Weight: Standard device:
261g (low profile),
270g (deep / IP65)
First Fix option:
Wiring Options
271g (low profile),
280g (deep / IP65)

First Fix Device Standard Device Connections

Out of Box Contents:

First Fix Deep / IP 65 Deep / IP 65 &


ENscape Sounder Beacon Standard Device
Option Option First Fix Option

Sounder beacon including selected base ü ü ü ü

P pack (includes terminal block & continuity link) û ü û ü

O Ring for IP65 Sealing û û ü ü


INSTALLATION INSTRUCTIONS FOR CONVENTIONAL WALL & CEILING MOUNT SOUNDER BEACON
MODELS INSTALLATION DIMENSIONS
CWSS-xx-S3 = Sounder Beacon, Shallow Base, O Class STEP 1 Shallow and Deep Base
CWSS-xx-S4 = Sounder Beacon, Shallow Base, O Class, First Fix
CWSS-xx-S5 = Sounder Beacon, Shallow Base, W Class, C Class
100mm

CWSS-xx-S6 = Sounder Beacon, Shallow Base, W Class, First Fix, C Class


CWSS-xx-W3 = Sounder Beacon, Deep Base, O Class
CWSS-xx-W4 = Sounder Beacon, Deep Base, O Class, First Fix
CWSS-xx-W5 = Sounder Beacon, Deep Base, W Class, C Class
122mm

CWSS-xx-W6 = Sounder Beacon, Deep Base, W Class, First Fix, C Class


98mm

xx Denotes Body & Lens Colour

TECHNICAL INFORMATION STEP 2 1 - First stage wiring


2 - Second stage wiring
VOLTAGE RANGE (OPERATING) C/W Class 12-29 V INSTALLATION TIPS

Installation data sheet


VOLTAGE RANGE (EN54- 23) C/W Class approved at 12-29 V These products are universal devices suitable for wall &
ceiling mount installations.

ü ü ü ü
MAX CURRENT CONSUMPTION C/W Class 101mA
MAX POWER CONSUMPTION C/W Class 2.9 W These products are not designed for use with pulsed panel
VOLTAGE RANGE (OPERATING) O Class 12-29 V outputs. If more than 1 mode is required use the second
stage tone.
VOLTAGE RANGE (EN54-23) O Class approved at 24-29 V
+
_ +
_ Continuity link board.
Drill out the required mounting and wiring holes in the rear
VOLTAGE RANGE (EN54-3) 9-14V 18-29V
_ _ First-fix option. of the base. Do not attempt to “knock-out” the holes with a
MAX CURRENT CONSUMPTION O Class 51mA
STEP 3 screwdriver.
MAX POWER CONSUMPTION O Class 1.5 W
No. OF STAGES 2 Factory setting is Tone 1 at medium volume.
BEACON FLASH RATE 0.5Hz Installation tools required: Pliers, Screwdriver, Drill.
MONITORING Reverse polarity
RELATIVE HUMIDITY Up to 93% (± 3%) - non condensing Accessories: -
SC076 = 5x Earth Strap, SC077 = 5x Terminal Block,
WIRE GAUGE FOR TERMINAL 0.5mm2 - 2.5mm2 (max) SC078 = 5x Installer Link, P310 = 5x Deep Base O-Ring,
OPERATING TEMPERATURE -25 to +70oC P311 = 5x Deep Base Gasket, CSR = 5x Shallow Base-
Red, CSW = 5x Shallow Base-White, CWW=5x IP65 Deep
Base-White, CWR = 5x IP65 Deep Base-Red.
VOLUME SETTINGS
See Tone Table
Volume setting is adjusted by switch 6 on the 6-way DIP switch on the on reverse. WARNING: Use extreme caution when adjusting the
bottom of the product. (See switch diagram overleaf). switches on the 6-way DIP switch. The switch contacts
STEP 4 and exposed PCB can be affected by electro-static
TONE SETTINGS
The tone setting is selected by switches 1 to 5 on the 6-way DIP switch. The “click” discharge.
switch diagram and tone table are overleaf. The second stage tone is related WARNING: Care must be taken when installing first-fix
to the first stage tone selection made via the DIP switch. The second stage is model types with the KAC continuity link board. DO NOT
controlled by the fire panel and becomes active through the wiring configuration. touch the exposed link board contacts as this may result in
an electrical shock.
2
BASES/IP RATING The sounder minimum voltage is limited to 12V to maintain
beacon performance.
Shallow Base (IP21C) Deep Base (IP65)
WALL & CEILING MOUNT
1 SOUNDER BEACON MODELS:
CWSS-xx-S3, CWSS-xx-S4
STEP 5
CWSS-xx-S5, CWSS-xx-S6
CWSS-xx-W3
CWSS-xx-W4
CWSS-xx-W5
If the Deep Base IP65 option is used, the o-ring seal must be fitted to the base CWSS-xx-W6
as shown. If required, the deep base gasket accessory can be installed See installation step 3 for
between the base and the mounting surface. anti-tamper screw location. D 1101 Issue C

Accessories:
Low Profile Bases Deep Bases IP and Earthing Kits Electrical Items
CSR – Red low profile base, pack of 5 CWR – Red deep / IP 65, pack of 5 P 311 – Deep base gasket, pack of 5 SCO77- Terminal block, pack of 5
CSW – White low profile base, pack of 5 CWW – White deep / IP 65 base, pack of 5 P 310 - Deep base O Ring, pack of 5 SCO78- Installer link, pack of 5
SC076 - Earth strap, pack of 5

> KAC Alarm Company Ltd KAC House, Thornhill Road, North Moons Moat, Redditch, B98 9ND, United Kingdom
Tel: +44 (0) 1527 406655 Fax: +44 (0) 1527 406677 e-mail: marketing@kac.co.uk

We reserve the right to amend the content of this document without prior notice. Pending LPCB approvals.

You might also like