2900 Saturn Street #3 Addit porte Hl “Attn: Jenny Pu Certificate of Calibration Report Number : 17080132 "27317180008 Reference Standards used in this calibration are traceable to the National Institute of Standards and Technology (NIST) or other recognized National Metrology institute (NMI's). This calibration is compliant to ANSI/NCSL 2540-1-1994. The calibration report applies only to the item described. Uncertainties of the measurements are based upon a coverage factor of k=2 providing an approximate 95% confidence level. In tolerance or pass conditions are based on the test results falling within specified limits with no reduction by the uncertainty of the measurement. Agilent Digital Multimeter 3458a_— | mvasoag291| 7/7/2017 7772018 S-B2NIN-20-1 Fluke Multifunction Calibrator| 57204. 2016203 5/3/2017 5822018 4D11775 Additel Quartz Pressure 1.694-AP4OKQ-PS 00516090001 | 7/13/2017 | 10/13/2017 17071401 ‘The recommended calibration interval for this instrument is 12 months from the date of verification, Your particular quality assurance requirements may supersede this recommendation. Environmental Conditions Performed by: Bor e ‘Temperature: 23.5°C é Humidity: 59% RH Approved By Report Number : 17080132 Test Results Pressure Reference [indicated Reading] Difference | Low limit [High limit : Parameter Coneition (psi) (psi) (psi) si) (psi) Tinearty mm Evy 05 399 40.1 pass 70000 100087 #7 3960.0 To040.0 pass 20000 2010.3, 103 19960.0 | 200400 pass 30000 300124 14 29960.0 | 300400 pass 3999.9 400140 141 39959.9 | _40030.9 pass Tiystersis [30000 3004.0, 40 29960.0 | _30040.0 ass 20000 2003.7 37 19960.0 | 200400, ass 70000 10009.6 96 9960.0 10040.0 pass 02 04 05; 398 402 pass DC Voltage Measurement Accuracy: +(0.01%RD + I.5mV) Range [Reference DUT Difference | Low limit | High limi ae o w o. wo wo w -30,0000__| 30.0003 | 0.0003 | 30.0035 | 29.9955 pass 10,0000} _-10.0001 | 0.0001 | -10.0025 | 9.975 pass 5.0000 ~5.0000 0.0000 | 5.0020 | 4.9980, pass 30%030 [0.0000 0.0000 0.0000 | 0.0015 0.0015 pass 5.0000 5.0001 0.0001 4.9980) 5.0020 pass 10,0000 70,0002 0.0002 9.9975 10,0025 pass 30.0000, 30.0008, 0.0003 | 299955 | 30,0045 pass DC Current Measurement Accuracy: +(0.01%RD + 1.5pA) Range | _ Reference DUT Difference [Low limit | High aaa (mA) (mA) (mA) (mA) (mA) (mA) “30.0000 30.0001 | 0.0001 | 30.0045 | 29.9955 pass -10.0000 | _-10.0000 0.0000 | _-10.0025 | 9.9975 pass 5.0000 4.9999 0.0001 5.0000 | 4.9980 ass 30:30 [7 0.0000 0.0000 0.0000 | 0.0015 0.0015 pass 5.0000 5.0001 0.0001 4.9980 5.0020 pass 10,0000 10,0001 0.0001 9.9975 10.0025 pass 30.0000, 30.0001 0.0001 29.9955 | 30.0045 pass 24V DC Output Accuracy: #0.5V Range Dor Reference | Difference | Lowlimit | High mit cae W) Ww) W) mw) Ww) W) 24 24 74.0220 0.0220 | 23.5000__| 24.5000, pass

You might also like