You are on page 1of 2

DESIGN OF TIED COLUMNS

Project : Model BRENDA


Location :
Date 27-Mar-14
Title Design of Column 1

STRUCTURAL PROPERTIES
Lu = 6.0 m Dm = 16 Ø
b= 150 mm Dt = 10 Ø
d= 300 mm Ccover = 30 mm

MATERIAL PROPERTIES
fc = 20.7 Mpa Pg = 0.016
fy = 275.0 Mpa Ø= 0.70
Es = 200.0 Gpa

SERVICE LOADS
DL = 102.4 KN
LL = 80.3 KN

DESIGN

I. Computing for axial load Pu

Pu = 1.4DL + 1.7LL
Pu = 279.73 KN

II. Computing the required gross area of column

Pu
Ag =
Ø * 0.80 (0.85fc (1-Pg) + fy Pg)
Ag = 23004.88 mm2
h= Ag 1/2

h= 151.67 mm ok!

III. Computing the required steel reinforcement

Ag = bd = 45000 mm2 use given b and d


As = Pg Ag
As = 720 mm2 ¶ Dm2
Ab = 201.06 sq.mm.
4

N= As N Pi Dm2
As =
Ab 4
723.82 mm2
N= 3.58 Pg = As
Ag
Say N = 4 pcs Pg = 0.01608495 >0.01 o.k.!

IV.Checking slenderness ratio

sr = 34 - 12(M1/M2) h= d K= 0.90
sr = 22 r=
0.3h
90 mm
K Lu = 60 >sr ( slenderness ratio should be considered )
r

V. Computing for the spacing of tie wires

S1 16 Dm 256
S2 48 Dt 480
S3 least dimension 150 ««« GOVERNS !

Used 10 Ø mm diameter spaced @150 mm O.C.

VI. Check for Actual Safe Load

Pu = Ø (0.80) (0.85 fc'( Ag-As) + fyAs)

Pu = 547.73 KN
Po = 279.73 KN < Pu The design data is safe
DESIGN OF TIED COLUMNS
Project : Model BRENDA
Location :
Date 27-Mar-14
Title Design of Column 2

STRUCTURAL PROPERTIES
Lu = 7.0 m Dm = 16 Ø
b= 150 mm Dt = 10 Ø
d= 300 mm Ccover = 30 mm

MATERIAL PROPERTIES
fc = 20.7 Mpa Pg = 0.016
fy = 414.0 Mpa Ø= 0.70
Es = 200.0 Gpa

SERVICE LOADS
DL = 15.0 KN
LL = 30.0 KN
0.886824
DESIGN

I. Computing for axial load Pu

Pu = 1.2DL + 1.6LL
Pu = 66.00 KN

II. Computing the required gross area of column

Pu
Ag =
Ø * 0.80 (0.85fc (1-Pg) + fy Pg)
Ag = 4923.54 mm2
h= Ag 1/2

h= 70.17 mm ok!

III. Computing the required steel reinforcement

Ag = bd = 45000 mm2 use given b and d


As = Pg Ag
As = 720 mm2 ¶ Dm2
Ab = 201.06 sq.mm.
4

N= As N Pi Dm2
As =
Ab 4
723.82 mm2
N= 3.58 Pg = As
Ag
Say N = 4 pcs Pg = 0.01608495 >0.01 o.k.!

IV.Checking slenderness ratio

sr = 34 - 12(M1/M2) h= d K= 0.90
sr = 22 r=
0.3h
90 mm
K Lu = 70 >sr ( slenderness ratio should be considered )
r

V. Computing for the spacing of tie wires

S1 16 Dm 256
S2 48 Dt 480
S3 least dimension 150 ««« GOVERNS !

Used 10 Ø mm diameter spaced @150 mm O.C.

VI. Check for Actual Safe Load

Pu = Ø (0.80) (0.85 fc'( Ag-As) + fyAs)

Pu = 604.07 KN
Po = 66.00 KN < Pu The design data is safe

You might also like