You are on page 1of 20

CTC 1602.

21
MTCO 1390 / TSU 1391

Supplement to the operating instructions


Imprint

The information, descriptions, data and illustrations in these


operating instructions may be changed without prior notice
and do not represent any liability on the part of the Siemens
VDO Automotive AG. The description is based on the state-of-
the-art of the operating system / program version at the time
of printing.

No part of this documentation may be reproduced by photo-


copying or other techniques without the prior written permis-
sion of the Siemens VDO Automotive AG. This
documentation may not be given to third parties without the
prior written consent of the Siemens VDO Automotive AG.

© 08.2005 by Siemens VDO Automotive AG.


All rights reserved.

Responsible for the contents:

Siemens VDO Automotive AG


Commercial Vehicles
P.O. Box 1640
D-78006 Villingen-Schwenningen

2 Programming the MTCO 1390 / TSU 1391


Preface

Dear user,

progressive technology and high quality of the testing devices


is guaranteed by continuous further development.

The performance range of the testing device


• CTC 1602.21
has been extended by the initialisation, programming and in-
spection of the Modular Tachograph MTCO 1390 as well as
the Tachometer Simulator Unit TSU 1391.

Purpose of this This documentation, BA00.1602.21 600 300, serves as a sup-


Description plement to the existing operating instructions and describes
the proper execution of the initialisation, programming and
inspection of the MTCO 1390 and the TSU 1391.

Since the procedure corresponds to that for the device type


MTCO 1324, only operating steps which deviate from the nor-
mal procedure will be described in detail.

In the following the CTC 1602.21 will be referred to by the ab-


NOTE breviation CTC.

This documentation only applies when used with the operat-


CAUTION ing instructions CTC 1602.21, BA00.1602.21 1xx 300.

© Siemens VDO Automotive AG 3


Table of contents

Chapter 1 MTCO 1390 .................................................................5


1.1 Measurement preparations ......................................................................... 5
1.2 Program overview (menu tree) .................................................................... 6
1.3 Measuring and testing procedures ............................................................... 7
1.4 Device testing ............................................................................................. 7
1.5 Programming the MTCO 1390 ..................................................................... 8
1.5.1 Installation data .................................................................................... 9
1.5.2 Product code ...................................................................................... 10
1.5.3 Maximum speed (warning speed) ....................................................... 11
1.5.4 Rpm recording (limit values for the rpm ranges) .................................. 12
1.5.5 Rear axles (rear axle shift) ................................................................... 15

Chapter 2 TSU 1391 ...................................................................17


2.1 Measurement preparations ....................................................................... 17
2.2 Program overview (menu tree) .................................................................. 18
2.3 Program procedure ................................................................................... 19

4 Programming the MTCO 1390 / TSU 1391


MTCO1390

Chapter 1 MTCO 1390

The Modular Tachograph MTCO 1390 has been designed for


vehicles for which the recording of speed and the driving
times is required by national regulations.

The MTCO 1390 records the vehicle speed, the distance trav-
elled and the driving and stationary times of the vehicle.

1.1 Measurement preparations

Fig. 1: MTCO 1390 testing and programming interface

Connect the MTCO 1390, just like the device type MTCO 1324,
to the test device via the test and programming interface (1).

For detailed information concerning the measurement prepa-


NOTE rations please refer to the operating instructions CTC 1602.21,
BA00.1602.21 1xx 300.

© Siemens VDO Automotive AG 5


1.2 Program overview (menu tree)

1.2 Program overview (menu tree)

CTC measuring
Automatic measuring track
Manual measuring track
Device testing
Speed test
Odometer test
Test chart
Variable speed
Clock test
Programming
Installation data TCO
k constant
n constant
Wheel circumference
Odometer
VIN (Vehicle identification number)
Configuration
CAN configuration
Product code
Drive shaft ppr
Installation date
Calibration date
Seal number
Max. speed
RPM recording
Rear axles
Date – time
Programming TCO
Programming CTC
Time zone
Change-over times
Activate KITAS
Manufacturing data
Distance covered
Erase error memory
Save TCO data
Read TCO Data
Write TCO Data
Load DTCO data
Language
German
English
French
User defined
Download language*
Checksum/test
Adjustments*

* Access only for authorised Siemens VDO distributors.

6 Programming the MTCO 1390 / TSU 1391


1.3 Measuring and testing procedures

1.3 Measuring and testing procedures

For the test certificate and the programming of the tacho-


graph you have to determine and save the values "w"= travel
pulse count and "k"= device constant.

Carry out the measuring and testing procedures in the same


way as for the device type MTCO 1324.

For detailed information concerning the measuring and test-


NOTE ing procedures please refer to the operating instructions
CTC 1602.21, BA00.1602.21 1xx 300.

1.4 Device testing

With the CTC you can test the following functions of the
MTCO 1390:
• Speed test
• Odometer test
• Test chart (without recording of the working times)
• Variable speed
• Clock test

Carry out the device testing in the same way as for the device
type MTCO 1324.

For detailed information concerning the device testing please


NOTE refer to the operating instructions CTC 1602.21,
BA00.1602.21 1xx 300.

© Siemens VDO Automotive AG 7


1.5 Programming the MTCO 1390

1.5 Programming the MTCO 1390

With the CTC you can programm or request the following data
from the memory of the MTCO 1390:
• Installation data*
• Date – time
• Manufacturing data
• Distance covered
• Erase error memory

Carry out the programming in the same way as for the device
type MTCO 1324.

* The entry of the installation data differs from the procedure


for the device type MTCO 1324 and will be described in detail
on the following pages.

For detailed information concerning the programming please


NOTE refer to the operating instructions CTC 1602.21,
BA00.1602.21 1xx 300.

8 Programming the MTCO 1390 / TSU 1391


1.5 Programming the MTCO 1390

1.5.1 Installation data

You can enter the following installation data with the pro-
gramming of the MTCO 1390:
• k constant
• n constant
• Wheel circumference
• Odometer
• VIN (Vehicle identification number)
• Configuration
• CAN configuration
• Product code*
• Drive shaft ppr
• Installation date
• Calibration date
• Seal number
• Max. speed*
• RPM recording*
• Rear axles*

Carry out the entry of the installation data in the same way as
for the device type MTCO 1324.

* The entry of the present data differs from the procedure for
the device type MTCO 1324 and will be described in detail on
the following pages.

© Siemens VDO Automotive AG 9


1.5 Programming the MTCO 1390

1.5.2 Product code

You can set the individual versions in the 6th to the 16th place
of the product code.

Step / display Programming procedure


1 Select the "Product code" menu
#INSTALLATION DATA #
CAN CONFIGURATION – Select with the key and ...
PRODUCT CODE <
DRIVE SHAFT PPR – confirm with the key.

2 TCO evaluation
# PRODUCT CODE #
The CTC reads out the tachograph type and the pa-
TCO - EVALUATION rameter data.
PLEASE WAIT

3 The product code is displayed.


# PRODUCT CODE #
1390.203001100001 – Activate the new entry with the key or ...
CHANGE WITH KEY F1
CANCEL WITH KEY C – return to the "Installation data" menu with the
key.
4 Enter new value
# PRODUCT CODE #
– Select decade (6th to 16th place) with the or
1390.203001100001 key, enter a new value with the ... key
PROGRAM WITH KEY ’
and ...
– confirm with the key.
5 After programming, the value entered is displayed.
# PRODUCT CODE #
1390.203001100001
CHANGE WITH KEY F1 Ending the program
CANCEL WITH KEY C
– Return to the "Installation data" menu with the
key.

10 Programming the MTCO 1390 / TSU 1391


1.5 Programming the MTCO 1390

1.5.3 Maximum speed (warning speed)

Step / display Programming procedure


1 Select the "Maximum speed" menu
#INSTALLATION DATA #
MAX. SPEED < – Select with the key and ...
RPM RECORDING
REAR AXLES – confirm with the key.

2 TCO evaluation
# MAX. SPEED #
The CTC reads out the tachograph type and the pa-
TCO - EVALUATION rameter data.
PLEASE WAIT

3 Enter new value


# MAX. SPEED #
CUR VALUE:080 KM/H – Select decade with the or key, enter a
NEW VALUE:_00 KM/H new value* with the ... key and ...
PROGRAM WITH KEY ’
– confirm with the key.
* maximum speed: 001 - 255 km/h
4 After programming, the value entered is displayed.
# MAX. SPEED #
CUR VALUE:082 KM/H
NEW VALUE:_00 KM/H Ending the program
PROGRAM WITH KEY ’
– Return to the "Installation data" menu with the
key.

© Siemens VDO Automotive AG 11


1.5 Programming the MTCO 1390

1.5.4 Rpm recording (limit values for the rpm ranges)

For the 7 day device, the rpm ranges will be recorded on the
front side of the chart.

Example The following limit values for the rpm recording have been
programmed into the MTCO 1390 ex works::
• Lower limit: 900 [min-1]
• Upper limit: 1400 [min-1]

The following rpm ranges result from these programmed limit


values::

Range 1: 0 - 899 [min-1]

Range 2: 900 - 1399 [min-1]

Range 3: above 1400 [min-1]

When entering the limit values for the rpm recording, the val-
NOTE ue for the upper limit (HIGH LIMIT) must exceed the value for
the lower limit (LOW LIMIT).

Step / display Programming procedure


1 Select the "RPM recording" menu
#INSTALLATION DATA #
MAX. SPEED – Select with the key and ...
RPM RECORDING <
REAR AXLES – confirm with the key.

2 Select the "Low limit" menu


# RPM RECORDING #
LOW LIMIT < – Select with the key and ...
HIGH LIMIT
– confirm with the key.

12 Programming the MTCO 1390 / TSU 1391


1.5 Programming the MTCO 1390

If the lower limit (LOW LIMIT) to be entered exceeds the pro-


NOTE grammed upper limit (HIGH LIMIT), the upper limit has to be
increased first.

Step / display Programming procedure


3 TCO evaluation
# LOW LIMIT #
The CTC reads out the tachograph type and the pa-
TCO - EVALUATION rameter data.
PLEASE WAIT

4 Enter new value


# LOW LIMIT #
CUR VALUE: 0900/1400 – Select decade with the or key, enter a
NEW VALUE: _000 new value* with the ... key and ...
PROGRAM WITH KEY ’
– confirm with the key.
* permissible value: 0201 - 3300 min-1
5 After programming, the value entered is displayed.
# LOW LIMIT #
CUR VALUE: 1200/1400
NEW VALUE: _000 Continue the program
PROGRAM WITH KEY ’
– Return to the "RPM recording" menu with the
key.
6 Select the "High limit" menu
# RPM RECORDING #
LOW LIMIT – Select with the key and ...
HIGH LIMIT <
– confirm with the key.

7 TCO evaluation
# HIGH LIMIT #
The CTC reads out the tachograph type and the pa-
TCO - EVALUATION rameter data.
PLEASE WAIT

© Siemens VDO Automotive AG 13


1.5 Programming the MTCO 1390

Step / display Programming procedure


8 Enter new value
# HIGH LIMIT #
CUR VALUE: 1200/1400 – Select decade with the or key, enter a
NEW VALUE: _000 new value* with the ... key and ...
PROGRAM WITH KEY ’
– confirm with the key.
* permissible value: 0201 - 3300 min-1
9 After programming, the value entered is displayed.
# HIGH LIMIT #
CUR VALUE: 1200/1600
NEW VALUE: _000 Ending the program
PROGRAM WITH KEY ’
– Return to the "RPM recording" and the "Installa-
tion data" menu step by step with the key.

14 Programming the MTCO 1390 / TSU 1391


1.5 Programming the MTCO 1390

1.5.5 Rear axles (rear axle shift)

Step / display Programming procedure


1 Select the "Rear axles" menu
#INSTALLATION DATA #
MAX. SPEED – Select with the key and ...
RPM RECORDING
REAR AXLES < – confirm with the key.

2 TCO evaluation
# REAR AXLES #
The CTC reads out the tachograph type and the pa-
TCO - EVALUATION rameter data.
PLEASE WAIT

3 Enter new value


# REAR AXLES #
CUR VALUE: 1.3830 – Select decade with the or key, enter a
NEW VALUE: _.0000 new value* with the ... key and ...
PROGRAM WITH KEY ’
– confirm with the key.
* permissible value: 0,0000 - 6,5595
4 After programming, the value entered is displayed.
# REAR AXLES #
CUR VALUE: 2.3230
NEW VALUE: _.0000 Ending the program
PROGRAM WITH KEY ’
Return to the "Installation data" menu with the
key.

© Siemens VDO Automotive AG 15


16 Programming the MTCO 1390 / TSU 1391
TSU1391

Chapter 2 TSU 1391

The Tachometer Simulator Unit TSU 1391 is the interface be-


tween the pulse generator and the instruments within the ve-
hicle. Via the CAN bus, the TSU 1391 provides data for
displaying the speed, the distance travelled as well as the time
and date.

2.1 Measurement preparations

Fig. 2: TSU 1391 testing and programming interface

Connect the TSU 1391, just like the device type MTCO 1324,
to the test device via the test and programming interface (1).

For detailed information concerning the measurement prepa-


NOTE rations please refer to the operating instructions CTC 1602.21,
BA00.1602.21 1xx 300.

© Siemens VDO Automotive AG 17


2.2 Program overview (menu tree)

2.2 Program overview (menu tree)

CTC measuring
Automatic measuring track
Manual measuring track
Device testing
Odometer test
Variable speed
Clock test
Programming
Installation data TCO
k constant
n constant
Wheel circumference
Odometer
VIN (Vehicle identification number)
Configuration
CAN configuration
Product code
Drive shaft ppr
Installation date
Calibration date
Seal number
Date – time
Programming TCO
Programming CTC
Time zone
Change-over times
Manufacturing data
Distance covered
Erase error memory
Save TCO data
Read TCO Data
Write TCO Data
Load DTCO data
Language
German
English
French
User defined
Download language*
Checksum/test
Adjustments*

* Access only for authorised Siemens VDO distributors.

18 Programming the MTCO 1390 / TSU 1391


2.3 Program procedure

2.3 Program procedure

Carry out the measuring and testing procedures, the device


testing and the programming in the same way as for the de-
vice type MTCO 1324.

For detailed information concerning the measuring and test-


NOTE ing procedures, the device testing and the programming
please refer to the operating instructions CTC 1602.21,
BA00.1602.21 1xx 300.