D779.131.00/05 en 2009-07 Sa
2D-ARRAYXDR (T10031) and ARRAY INTERFACEXDR (T16038)
General Information
General Information
− The product bears the CE-mark "CE-0124" in uct only, if assembly, extension, readjustment,
accordance with the Council Directive modification or repair is carried out by PTW-
93/42/EEC about Medical Devices and fulfills Freiburg or by persons authorized by PTW-
the essential requirements of Annex 1 of this Freiburg, and if the product is used in compli-
directive. The product is a class IIb device ance with the technical documentation.
(MDD).
− In case of any questions concerning service,
− Electrical safety support or warranty please contact your sup-
The product fully complies with the require- plier.
ments of the standard IEC 61010-1.
− This technical documentation is in conformity
− Electromagnetic immunity with the product specifications and all applica-
The product fully complies with the require- ble safety standards valid at printing date. All
ments of the following standards: rights are reserved for devices, circuits, tech-
IEC 61326-1 and niques and names appearing in the manual.
CISPR11/DIN EN 55011 class B.
− No part of the technical documentation may be
− The instruction manual is an integral part of reproduced without written permission from
the product. It should always be kept near the PTW-Freiburg.
product. Observance of the manual is a pre-
requisite for proper product performance and − PTW-Freiburg is registered manufacturer ac-
correct operation. cording to the ElektroG (Elektro- und Elektro-
nikgeräte-Gesetz).
− Operator safety, specified measuring accuracy Elektro-Altgeräte-Register (EAR) Registration
and interference-free operation can be guaran- number DE15599992
teed only if original products and parts are u-
sed. Furthermore only the accessories listed in − PTW-Freiburg works in strict accordance with
this manual are approved by PTW-Freiburg a quality management system which is con-
and may be used in conjunction with the prod- tinuously updated according to national and in-
uct, or else accessories whose use has been ternational standards.
expressly permitted by PTW-Freiburg. Safe
operation and proper product performance are
not guaranteed if accessories or consumables
PTW-FREIBURG
from other manufacturers are used.
Physikalisch Technische Werkstätten
− PTW-Freiburg cannot be held liable for dam- Dr. Pychlau GmbH
ages resulting from the use of accessories, Lörracher Str. 7
consumables from other manufacturers or 79115 FREIBURG
when the user ignores the instructions and in- GERMANY
formation given in this manual. Phone: +49 761 49055-0
Fax: +49 761 49055-70
− The warranty period is 1 (one) year and begins info@ptw.de
on the day of delivery. It is unaffected by re- www.ptw.de
pairs covered by the warranty regulations.
2 D779.131.00/05 en
2D-ARRAYXDR (T10031) and ARRAY INTERFACEXDR (T16038)
Contents
Contents
General Information 2
Contents 3
Illustrations 4
Intended Use 5
Safety Information 5
Operating Manual 9
1 Equipment Description 9
1.1 2D-ARRAYXDR 9
1.2 ARRAY INTERFACEXDR 11
Technical Manual 17
3 Technical Specifications 17
4 Order Information 20
Service Manual 21
5 Cleaning 21
6 Preventive Maintenance 22
7 Fuses 23
D779.131.00/05 en 3
2D-ARRAYXDR (T10031) and ARRAY INTERFACEXDR (T16038)
Illustrations
Literature 24
Index 27
Illustrations
Figure 1: 2D-ARRAYXDR 9
Figure 2: Front view of the ARRAY INTERFACEXDR 11
Figure 3: Rear view of the ARRAY INTERFACEXDR 11
Figure 4: Calibration file 12
Figure 5: Overview of system structure 14
Figure 6: Initialization file of MatrixScan with default settings 15
Figure 7: Initialization file of MatrixScan 16
Figure 8: Unlocking the fuse holder 23
4 D779.131.00/05 en
2D-ARRAYXDR (T10031) and ARRAY INTERFACEXDR (T16038)
Intended Use
NOTE
Provides useful information to assure that you
get the most from your equipment.
D779.131.00/05 en 5
2D-ARRAYXDR (T10031) and ARRAY INTERFACEXDR (T16038)
Safety Information
Safety Information
DANGER WARNING
Operation in areas where an explosion hazard Electricity is a source of risk, particularly when
may occur or in oxygen-enriched atmospheres the product is not in perfect operating condition
or when it is operated inappropriately.
Explosion Hazard!
Shock Hazard!
The product is not suitable for operation in areas
of risk where an explosion hazard may occur. Strictly observe the following warnings. Failure to
Explosion hazards may be caused by the use of do so may endanger the lives of the patient, the
combustible anaesthetics, skin-cleansing agents user and other persons involved.
and disinfectants.
− Before using the product, the user must as-
Furthermore the product is not suitable for appli- certain that it is in correct working order and
cation in oxygen-enriched atmospheres. The operating condition.
atmosphere is considered to be oxygen-enriched
− Before putting the device into operation, visu-
when more than 25 % of oxygen or nitrous oxide
ally inspect all connection cables for signs of
is added to the ambient air.
damage. Damaged cables and connectors
must be replaced immediately.
6 D779.131.00/05 en
2D-ARRAYXDR (T10031) and ARRAY INTERFACEXDR (T16038)
Safety Information
WARNING WARNING
Electricity is a source of risk, particularly when Operation in conjunction with high-energy radia-
the product is not in perfect operating condition tion that activate the material of the product.
or when it is operated inappropriately.
Risks to Persons!
Shock Hazard!
Radiation protection: During radiation of
Strictly observe the following warnings. Failure to 2D-ARRAYXDR and accessories with high-energy
do so may endanger the lives of the patient, the radiation (e.g. proton and heavy ions radiation)
user and other persons involved. the irradiated materials can be activated. In order
to avoid radiation hazards observe the appropri-
Exclusion of operation as device with patient
ate radiation protection directives.
contact: The device is not intended for use in
direct contact with the patient. Neither the device
nor any peripheral device may have contact to
WARNING
the patient.
Magnetic and electrical fields are capable of in-
Never touch the patient and open connectors of
terfering with the proper performance of the de-
the device at the same time.
vice.
Exclusion of operation as controlling instru-
Equipment Failure!
ment: The device is only designed for use as a
measuring device. The device must not be used − For this reason make sure that all external
to control radiodiagnostic equipment or radio- devices operated in the vicinity of the device
therapy units. comply with the relevant EMC requirements.
X-ray equipment, MRI devices and radio sys-
Use of peripheral devices: Peripheral devices
tems are possible sources of interference as
(PC, printer) may only be connected if they meet
they may emit higher levels of electromag-
the requirements of UL 1950/IEC 60950-1.
netic radiation. Keep the device away from
− Devices may be connected to other devices these devices and verify its performance be-
or to parts of systems only if it has been as- fore use.
certained that this connection does not impair
− The device should not be used in the immedi-
the safety of the patient, the operator or the
ate vicinity of or placed on top of or below o-
environment.
ther equipment. However, if the application
− If the device specifications do not contain requires an arrangement of devices as de-
information as to connecting the device to scribed above, the device should be watched
other equipment, you must consult the manu- to ensure its proper functioning in the specific
facturer of the other equipment or an expert arrangement.
about the effects of the connection on the pa-
− The customer or user of the device should
tient, the operator or the environment.
assure that it is used in an electromagnetic
environment as described in IEC 61326-1.
D779.131.00/05 en 7
2D-ARRAYXDR (T10031) and ARRAY INTERFACEXDR (T16038)
Safety Information
WARNING NOTE
Packaging material is a source of risk. Set up the device so that the operator has a
clear, unobstructed view of the control panel.
Suffocation Hazard!
Dispose of the packaging material, observing the
applicable waste-control regulations. Keep the NOTE
packaging material out of children's reach.
Do not position the device so that it is difficult to
operate the disconnecting device.
WARNING
Confusion of chemicals. NOTE
Risk of Poisoning! This symbol means:
Refer to user manual.
Chemicals required for application or mainte-
nance of the device, for instance, must under all
circumstances be stored, prepared, and kept at This symbol means:
hand in their specific containers. Failure to ob- Separate collection for electrical and
serve this instruction may result in severe conse- electronic equipment!
quences for the patient. (refer also to section Disposal of the
Product)
This symbol means:
CAUTION
The product bears the CE-mark.
Operation under inadequate ambient conditions.
This symbol means:
Equipment Damage! Date of manufacturing
Before connecting the device to the power line,
make sure that line voltage and frequency are This symbol means:
equivalent to the ratings indicated on the name- Labeling according to „Administra-
plate of the device. tion on the Control of the Pollution
Always observe the ambient conditions as indi- caused by Electronic Information
cated in the `Technical Specifications`. Products (ACPEIP)“ (China RoHS)
(refer also to Appendix)
8 D779.131.00/05 en
2D-ARRAYXDR (T10031) and ARRAY INTERFACEXDR (T16038)
Operating Manual – Equipment Description
Operating Manual
1 Equipment Description
1.1 2D-ARRAYXDR
Figure 1: 2D-ARRAYXDR
D779.131.00/05 en 9
2D-ARRAYXDR (T10031) and ARRAY INTERFACEXDR (T16038)
Operating Manual – Equipment Description
CAUTION
Direct radiation.
Equipment Damage!
Only the marked chamber area may be irradiated
(maximum 27 cm x 27 cm).
The other part of STARCHECK may not be irra-
diated because the electronic equipment under-
neath may be damaged.
Ionization Chambers
10 D779.131.00/05 en
2D-ARRAYXDR (T10031) and ARRAY INTERFACEXDR (T16038)
Operating Manual – Equipment Description
1 Power LED
1 2 3 4 5 6 7
D779.131.00/05 en 11
2D-ARRAYXDR (T10031) and ARRAY INTERFACEXDR (T16038)
Operating Manual – Installation and Start-up
− The 2D-ARRAYXDR is calibrated relatively at The calibration file of the 2D-ARRAYXDR (*.cal)
60
Co at PTW-Freiburg. With this calibration the delivered on the installation CD is copied during the
response of each chamber is aligned to the re- installation of MatrixScan into the directory
sponse of the center chamber (column: 14, row: ‘C:\Program Files\PTW\Common Files\Calibration
14) of the 2D-ARRAYXDR. Files’. After the first start of MatrixScan this data file
must be selected in the Measurement tab of the
− The chambers and amplifiers of the Options dialog via Tools → Options..
2D-ARRAYXDR are manufactured with very high
precision and thus a change of the response of This calibration file is only valid for the
the chambers is not due. If nevertheless prob- 2D-ARRAYXDR and ARRAY INTERFACEXDR combi-
lems occur, the 2D-ARRAYXDR has to be sent to nation calibrated together. Before each measure-
PTW-Freiburg for re-calibration. ment MatrixScan checks whether the serial number
of the ARRAY INTERFACE used matches with the
− The user is responsible for the absolute calibra- serial number entered in the calibration file. This
tion of the 2D-ARRAYXDR versus a dedicated means that you first have to enter the new serial
dosemeter for the radiation quality and measur- number in the calibration file after a change of the
ing depth used. The calibration factor is valid for ARRAY INTERFACE before you are able to per-
all channels. form an absolute calibration (e.g. with MatrixCal).
WARNING
Erroneous calibration.
Measuring Error!
The 2D-ARRAYXDR T10031 is calibrated together
with the PTW ARRAY INTERFACEXDR T16038.
The calibration is only valid for this specific com-
bination. If you change one of the two compo-
nents you have to perform a new absolute cali-
bration and you have to adapt the calibration file
(refer to section 2.1.1).
12 D779.131.00/05 en
2D-ARRAYXDR (T10031) and ARRAY INTERFACEXDR (T16038)
Operating Manual – Installation and Start-up
CAUTION
Unsuitable laying of the cable connecting.
Equipment Damage!
Pay attention to the cable connecting of the 2D-
ARRAYXDR to the ARRAY INTERFACEXDR if you
turn the gantry.
NOTE
Measurements have to be performed with the
PTW software MatrixScan. For further informa-
tion, please refer to the appropriate user manual
and in section 2.5.
D779.131.00/05 en 13
2D-ARRAYXDR (T10031) and ARRAY INTERFACEXDR (T16038)
Operating Manual – Installation and Start-up
Mains
PC
PTW ARRAY
RS-232 cable INTERFACEXDR
T16038
PTW 2D-ARRAYXDR
T10031
Equipment damage!
The 2D-ARRAYXDR must not be used for meas- In order to move the 2D-ARRAYXDR with the gantry
urements in water. The use in water causes de- the 2D-ARRAYXDR should be mounted on the gantry
struction of the array! with a special holding device.
CAUTION
The 2D-ARRAYXDR is designed for measuring in
Unsuitable laying of the cable connecting.
slab phantoms. PTW-Freiburg recommends the use
of PMMA or RW3 plates as phantom material. Equipment damage!
14 D779.131.00/05 en
2D-ARRAYXDR (T10031) and ARRAY INTERFACEXDR (T16038)
Operating Manual – Installation and Start-up
D779.131.00/05 en 15
2D-ARRAYXDR (T10031) and ARRAY INTERFACEXDR (T16038)
Operating Manual – Installation and Start-up
Drift Suppression
− Default setting: 0
i.e. no threshold adjusted
Example:
maximum Noise = 80 mGy/min
→ threshold = 160 mGy/min
Interval time = 400 ms
The threshold to enter in the initialization file is:
160 mGy
• 0,4 s = 0,0010667 Gy
60 s
16 D779.131.00/05 en
2D-ARRAYXDR (T10031) and ARRAY INTERFACEXDR (T16038)
Technical Manual – Technical Specifications
Technical Manual
3 Technical Specifications
Only values for which tolerances or limits are specified are guaranteed. Values for which no tolerances are spe-
cified are for information only.
Device designation 2D-ARRAYXDR ionization chamber array type 10031 for dose
measurement in conjunction with PTW ARRAY
INTERFACEXDR type 16038
Manufacturer PTW-Freiburg
Intended Use Quality assurance and dose verification for heavy ions and
proton radiation
Mode of operation Continuous operation
Electrical safety EN 61010-1
Overvoltage category II
Measured values Absorbed dose in water [Gy]
Chamber voltage + 1000 V
Current limiting from high voltage supply in Additional protection with resistor: max. 2 mA
case of an error
Measuring range
Dose 200 mGy up to max. indication
Resolution with MatrixScan
Dose 1 mGy
Dose rate 1 mGy/min
Characteristics of the ionization chambers
(irrespective of the measuring circuit)
Effect of incomplete ion collection
Maximum dose rate for continuous 20 Gy/s or 1200 Gy/min for saturation ≥ 99.0%
irradiation (i.e. T > 56 µs)
Ion collection time 56 µs
D779.131.00/05 en 17
2D-ARRAYXDR (T10031) and ARRAY INTERFACEXDR (T16038)
Technical Manual – Technical Specifications
18 D779.131.00/05 en
2D-ARRAYXDR (T10031) and ARRAY INTERFACEXDR (T16038)
Technical Manual – Technical Specifications
D779.131.00/05 en 19
2D-ARRAYXDR (T10031) and ARRAY INTERFACEXDR (T16038)
Technical Manual – Order Information
4 Order Information
Optional
Converter USB-RS232 L242064
converter "Belkin USB F5U103vea" to connect PTW devices with RS232
interface to a USB port of the PC (the USB port will be available as addi-
tional COM port in the system, i.e. COM3). For all Windows platforms except
Windows NT. Includes driver software
20 D779.131.00/05 en
2D-ARRAYXDR (T10031) and ARRAY INTERFACEXDR (T16038)
Service Manual – Cleaning
Service Manual
WARNING 5 Cleaning
Improper execution of service tasks.
Hazards to Persons! Equipment Damage! Device surfaces
The following service tasks must only be per-
formed by specially trained staff. WARNING
Liquids have entered the devices.
Further service tasks may only be carried out by
PTW-Freiburg or by persons authorized by Shock Hazard, Erroneous Measurement!
PTW-Freiburg.
The devices must be thoroughly inspected by
service personnel before being used again.
CAUTION
Disinfection of the surface with disinfectants on a
phenol base or peroxide compounds.
Equipment Damage!
Do not use disinfectants on a phenol base or
peroxide compounds to disinfect the surface.
D779.131.00/05 en 21
2D-ARRAYXDR (T10031) and ARRAY INTERFACEXDR (T16038)
Service Manual – Preventive Maintenance
22 D779.131.00/05 en
2D-ARRAYXDR (T10031) and ARRAY INTERFACEXDR (T16038)
Service Manual – Fuses
The ARRAY INTERFACEXDR uses 2 microfuses At the end of the product life the 2D-ARRAYXDR
(315 mA, slow-blow) L251009 which are accessible components must be disposed of in compliance
from the rear of the device (refer to Figure 3). with the applicable waste control regulations.
To replace the fuses proceed as follows: The different materials must be separated and re-
cycled as appropriate.
• Switch the ARRAY INTERFACEXDR off and dis-
connect it from the power line. The 2D-ARRAYXDR does not contain hazardous
materials.
• Disconnect the power cord from the ARRAY
INTERFACEXDR. The electronic components must be recycled ac-
cording to local regulations.
• Lift the locking clip on the fuse holder using a
small screwdriver and remove the fuse holder. The cost for an potential return at the end of the
product life time is to be borne by the customer.
• Replace the fuses.
D779.131.00/05 en 23
2D-ARRAYXDR (T10031) and ARRAY INTERFACEXDR (T16038)
Literature
Literature
24 D779.131.00/05 en
2D-ARRAYXDR (T10031) and ARRAY INTERFACEXDR (T16038)
Service Manual – Appendix: China Electronic Industry Standard Compliance
The following product pollution control information is provided according to SJ/T11364-2006 Marking for Control
of Pollution caused by Electronic Information Products.
根据SJ/T11364-2006标准规定的《电子信息产品污染控制标识要求》特提供以下有关产品污染控制方面的信息。
This symbol indicates the product contains hazardous materials in excess of the limits estab-
lished by the Chinese standard SJ/T11363-2006 Requirements for Concentration Limits for Cer-
tain Hazardous Substances in Electronic Information Products. The number in the symbol is the
Environment-friendly Use Period (EFUP), which indicates the period during which the toxic or
hazardous substances or elements contained in electronic information products will not leak or
mutate under normal operating conditions so that the use of such electronic information products
will not result in any severe environmental pollution, any bodily injury or damage to any assets.
The unit of the period is “Year”.
In order to maintain the declared EFUP, the product shall be operated normally according to the
instructions and environmental conditions as defined in the product manual, and periodic mainte-
nance schedules specified in Product Maintenance Procedures shall be followed strictly.
Consumables or certain parts may have their own label with an EFUP value less than the prod-
uct. Periodic replacement of those consumables or parts to maintain the declared EFUP shall be
done in accordance with the Product Maintenance Procedures.
This product must not be disposed of as unsorted municipal waste, and must be collected sepa-
rately and handled properly after decommissioning.
该标识表明本产品含有的有毒有害物质超出SJ/T11363-
2006标准规定的《电子信息产品中有毒有害物质的限量要求》。标识中的数字为本产品的环保使
用期限(EFUP),表明在正常使用的条件下,电子信息产品内含的有毒有害物质或元素不会发生
外泄或突变,用户使用该电子信息产品不会对环境造成任何严重污染或对人身、财产造成任何严重
损害的期限。单位为年。
为保证所声明的环保使用期限,应按产品手册中所规定的指示和环境条件进行正常使用,并严格遵
守产品维护程序中规定的定期维护和保养日程。
产品中的耗件或某些零部件可能具有单独的标识,其环保使用期限有可能短于产品本身的环保使用
期限。应按产品维护程序定期更换这些耗件或零部件,以保证所声明的整个产品的环保使用期限。
本产品在使用寿命结束后不可作为普通生活垃圾处理,必须另行收集并作妥善处理。
D779.131.00/05 en 25
2D-ARRAYXDR (T10031) and ARRAY INTERFACEXDR (T16038)
Appendix: China Electronic Industry Standard Compliance
2D-ARRAYXDR (T10031)
ARRAY INTERFACEXDR X O X X X X
(T16026)
O: Indicates that this toxic or hazardous substance contained in all of the homogeneous materials for this part
is below the limit requirement in SJ/T11363-2006.
X: Indicates that this toxic or hazardous substance contained in at least one of the homogeneous materials
used for this part is above the limit requirement in SJ/T11363-2006
• Data listed in the table represents best information available at the time of publication.
• This table shows where these substances may be found in the supply chain of PTW electronic information
products, as of the date of sale of the enclosed product. Note that some of the component types listed
above may or may not be a part of the enclosed product.
O: 表示该有毒有害物质在该部件所有均质材料中的含量均在SJ/T11363-2006 标准规定的限量要求以下。
X: 表示该有毒有害物质至少在该部件的某一均质材料中的含量超出SJ/T11363-2006 标准规定的限量要求。
• 此表所列数据为直至发布时所能获得的最全面信息。
• 此表表明自本产品销售之日起在PTW电子信息产品的供应链上何处可能找到以上所述有毒有害物质。请注
意,以上所列的部件类型中的一些可能不属于本产品。
26 D779.131.00/05 en
2D-ARRAYXDR (T10031) and ARRAY INTERFACEXDR (T16038)
Service Manual – Index
Index
A
XDR
ARRAY INTERFACE , front and rear view................ 11
C
Calibration ..................................................................... 12
Calibration file ............................................................... 12
Cleaning ........................................................................ 21
D
Disposal ........................................................................ 23
F
Fuses ............................................................................ 23
G
General information......................................................... 2
I
Illustrations ...................................................................... 4
Initialization file, MatrixScan .......................................... 15
Installation array............................................................ 13
Intended use ................................................................... 5
L
Literature ....................................................................... 24
M
Maintenance.................................................................. 22
Measuring range ........................................................... 13
O
Order information .......................................................... 20
S
Safety information ........................................................... 5
Setup of the 2D-ARRAY................................................ 14
Start of the system ........................................................ 13
System structure ........................................................... 14
T
Technical inspections of the measuring system ............ 22
Technical specifications ................................................ 17
D779.131.00/05 en 27