You are on page 1of 1

CLINKER GRINDER#2A 12 8.

5 H MOTOR NDE N Rise in vibration and abnormal


sound from motor may pl.be
inspected.
CLINKER GRINDER#2B 20 4.2 A MOTOR DE N

SCRAPPER CONV.#2A 35 3.2 H MOTOR DE N


SCRAPPER CONV.#2B 32 4.3 A MOTOR NDE N
SEAL AIR FAN#2B 39 6.2 H MOTOR DE N
ID FAN#7A 25 0.6 V MOTOR NDE N
ID FAN#7B 49 1.0 V MOTOR NDE N
ASH SL.P/P#B1(ST- 70 7.8 A P/P NDE BRG. A Vibration is in alarm range
III) (Limit:160/6.5) Probable
cause: i)Loose Pump
foundation.
ASH SL.P/P#B2(ST- 12 2.9 V MOTOR DE N
III)
ASH SL.P/P#B3(ST- 14 2.0 V MOTOR DE N
III)
ASH SL.P/P#B4(ST- 16 3.1 H MOTOR DE N
III)
SERVICE 16 3.1 H MOTOR DE N Vibration reduced from 33/33.7
WTR.P/P#B(ST-III) to normal after pump brgs.
Replacement.

-------------------------------------------------------------------------------------------
N : saamaanya
A : saMkot ]p AQaIxak
T : ivamaaocana (isqait AnauvaIxaNa)
-------------------------------------------------------------------------------------------