You are on page 1of 1

DATA INPUT

BREADTH OF COLUMN(b)= 350.00 mm


DEPTH OF COLUMN (d)= 350.00 mm
LOAD ON COLUMN = 200.00 kN
PADASTAL ON SINGAL SIDE= 0.00 mm
MONENT ALONG TO X= 0.0 kN.m
MONENT ALONG TO Y= 0.0 kN.m
S.B.C= 75 kN/m2
Fck= 25 N/mm2
Fy= 500 N/mm2
COVER= 50.00 mm

OUT PUT
REQUIERD PROVIDED MAXIMUM PRESSURE
LENGTH OF FOOTING (L)= 1712.70 mm 1750.00 mm 65 kN/m2
WIDTH OF FOOTING (B)= 1712.70 mm 1750.00 mm MAXIMUM PRESSURE
AREA OF FOOTING (A)= 2.93 m2 3.06 m2 SAFE 65 kN/m2

DEPTH REQUIRED= 180.09 mm X-PROJECTION 700.00 mm


OVERALL DEPTH OF FOOTING(D)= 300.00 mm Y-PROJECTION 700.00 mm

CHECK FOR TWO WAY SHEAR


PERIMETER AT CRITICAL SECTION = 2360.00 mm
DEPTH AT CRITICAL SECTION = 248.57 mm
NOMINAL SHEAR STRESS τv=Vu*P*D 0.48 N/mm2
PERMISSIBLE SHEAR STRESS τuc2 = τ'uc*ks= 1.25 N/mm2 SAFE

AST AST (X) PARALLEL TO LONG SIDE AST (Y) PARALLEL TO SHORT SIDE
DIA OF BAR 10 10
AST REQUIRED
NO OF BAR 9 9
AREA 630.00 m2 630.00 m2
AST PROVIDED
NO OF BAR 9 9
AREA 706.50 m2 706.50 m2
SPACING 206.25 mm 206.25 mm

CHECK FOR ONE WAY SHEAR (X)


Bx = b + 2 * dx 840.00 mm
DEPTH D= 245.00 mm
NOMINAL SHEAR STRESS Tv = 0.182 N/mm2
PERMISSIBLE SHEAR STRESS Tc = 0.280 N/mm2 SAFE

CHECK FOR ONE WAY SHEAR (Y)


By = d + 2 * dy 820.00 mm
DEPTH D= 235.00 mm
NOMINAL SHEAR STRESS Tv = 0.194 N/mm2
PERMISSIBLE SHEAR STRESS Tc = 0.305 N/mm2 SAFE

BEARING PRESSURE
ACTUAL BEARING STRESS = 3 N/mm2
PERMISSIBLE BEARING STRESS = 23 N/mm2 SAFE