You are on page 1of 24

SYNTEX ENGINEERING SERVICES LTD

Eco-Tech@Sunview, 1 Sunview Road ~08-17, Singapore 349565


Tel: 6741 5311 Fax: 67425311 Email: enquiries@syntexengineering.com

VISUAL INSPECTION REPORT


Client: ExxonMobil Location: Jurong / PAC / SCP
Purchase Order / Job No: Report No:
Work Location / Circuit: Work Order No:
Tag No / Equipment ID: Date of Inspection:
P&ID / Reference Drawing No: Inspector:

General Introduction / Job Scope:

Piping Details:

Pipe Line Name:

Pipe Line Number:

Piping Material:

Pipe Schedule:

Nominal Thickness:

Design Pressure :

Design Temperature:

Operating Pressure:

Operating Temperature:

Year Built:

SYN-EXM-16-007-VI-RP-001 REV: 1 1
Any hard copy printed is uncontrolled
SYNTEX ENGINEERING SERVICES LTD
Eco-Tech@Sunview, 1 Sunview Road ~08-17, Singapore 349565
Tel: 6741 5311 Fax: 67425311 Email: enquiries@syntexengineering.com

Inspection Results / Repairs or Alterations Carried Out:

Observations:

Note: Observations to include but not limited to: Protective Coatings, Corrosion, Cladding, Insulation, Leaks
Structural, Mechanical Damage.

Analysis (As Required):

Future Recommendations:

SYN-EXM-16-007-VI-RP-001 REV: 1 2
Any hard copy printed is uncontrolled
SYNTEX ENGINEERING SERVICES LTD
Eco-Tech@Sunview, 1 Sunview Road ~08-17, Singapore 349565
Tel: 6741 5311 Fax: 67425311 Email: enquiries@syntexengineering.com

Reference Drawing:

SYN-EXM-16-007-VI-RP-001 REV: 1 3
Any hard copy printed is uncontrolled
SYNTEX ENGINEERING SERVICES LTD
Eco-Tech@Sunview, 1 Sunview Road ~08-17, Singapore 349565
Tel: 6741 5311 Fax: 67425311 Email: enquiries@syntexengineering.com

Reference Photographs:

Photo 001: Piping observed with minor surface Photo 002: Piping observed with minor surface
rust, no sign of corrosion scale or metal loss was rust, no sign of corrosion scale or metal loss
noticed. was noticed.

Photo 003: Piping observed with minor surface Photo 004: At below the platform piping
rust, no sign of corrosion scale or metal loss was observed with minor surface rust, but no sign of
noticed. corrosion and metal loss.

SYN-EXM-16-007-VI-RP-001 REV: 1 4
Any hard copy printed is uncontrolled
SYNTEX ENGINEERING SERVICES LTD
Eco-Tech@Sunview, 1 Sunview Road ~08-17, Singapore 349565
Tel: 6741 5311 Fax: 67425311 Email: enquiries@syntexengineering.com

Photo 005: At below the platform elbow Photo 006: At below the platform elbow
observed with minor surface rust, but no sign of observed with minor surface rust, but no sign of
corrosion and metal loss. corrosion and metal loss.

Photo 007: Elbow observed with minor surface Photo 008: Elbow observed with minor surface
rust, no sign of corrosion scale or metal loss was rust, no sign of corrosion scale or metal loss
noticed. was noticed. Elbow observed with minor surface
rust, no sign of corrosion scale or metal loss
was noticed.

SYN-EXM-16-007-VI-RP-001 REV: 1 5
Any hard copy printed is uncontrolled
SYNTEX ENGINEERING SERVICES LTD
Eco-Tech@Sunview, 1 Sunview Road ~08-17, Singapore 349565
Tel: 6741 5311 Fax: 67425311 Email: enquiries@syntexengineering.com

Photo 009: Elbow observed with minor surface Photo 010: Elbow observed with minor surface
rust, no sign of corrosion scale or metal loss was rust, no sign of corrosion scale or metal loss
noticed was noticed

Photo 011: Piping observed with minor surface Photo 012: Piping observed with minor surface
rust, no sign of corrosion scale or metal loss was rust, no sign of corrosion scale or metal loss
noticed. was noticed

SYN-EXM-16-007-VI-RP-001 REV: 1 6
Any hard copy printed is uncontrolled
SYNTEX ENGINEERING SERVICES LTD
Eco-Tech@Sunview, 1 Sunview Road ~08-17, Singapore 349565
Tel: 6741 5311 Fax: 67425311 Email: enquiries@syntexengineering.com

Photo 013: Elbow observed with minor surface Photo 014: Elbow observed with minor surface
rust, no sign of corrosion scale or metal loss was rust, no sign of corrosion scale or metal loss
noticed was noticed

Photo 015: : Elbow observed with minor surface Photo 016: Elbow observed with minor surface
rust, no sign of corrosion scale or metal loss was rust, no sign of corrosion scale or metal loss
noticed was noticed.

SYN-EXM-16-007-VI-RP-001 REV: 1 7
Any hard copy printed is uncontrolled
SYNTEX ENGINEERING SERVICES LTD
Eco-Tech@Sunview, 1 Sunview Road ~08-17, Singapore 349565
Tel: 6741 5311 Fax: 67425311 Email: enquiries@syntexengineering.com

Photo 017: Elbow observed with minor surface Photo 018: Piping observed with minor surface
rust, no sign of corrosion scale or metal loss was rust, no sign of corrosion scale or metal loss
noticed. was noticed

Photo 019:Elbow observed with minor surface Photo 1: Elbow observed with minor surface
rust, no sign of corrosion scale or metal loss was rust, no sign of corrosion scale or metal loss
noticed. was noticed

SYN-EXM-16-007-VI-RP-001 REV: 1 8
Any hard copy printed is uncontrolled
SYNTEX ENGINEERING SERVICES LTD
Eco-Tech@Sunview, 1 Sunview Road ~08-17, Singapore 349565
Tel: 6741 5311 Fax: 67425311 Email: enquiries@syntexengineering.com

Photo 2: Elbow observed with minor surface rust, Photo 3: Elbow observed with minor surface
no sign of corrosion scale or metal loss was rust, no sign of corrosion scale or metal loss
noticed. was noticed

Photo 23: U-bolt support observed with surface Photo 4: U-bolt support observed with surface
rust, no sign of corrosion scales or deposits were rust, no sign of corrosion scales or deposits
noticed were noticed.

SYN-EXM-16-007-VI-RP-001 REV: 1 9
Any hard copy printed is uncontrolled
SYNTEX ENGINEERING SERVICES LTD
Eco-Tech@Sunview, 1 Sunview Road ~08-17, Singapore 349565
Tel: 6741 5311 Fax: 67425311 Email: enquiries@syntexengineering.com

Photo 25: U-bolt support observed with surface Photo 26: U-bolt support observed with surface
rust, no sign of corrosion scales or deposits rust, no sign of corrosion scales or deposits
were noticed were noticed

Photo 5: U-bolt support observed with surface Photo 6 : Piping observed with minor surface
rust, no sign of corrosion scales or deposits were rust, no sign of corrosion scale or metal loss
noticed. was noticed.

SYN-EXM-16-007-VI-RP-001 REV: 1 10
Any hard copy printed is uncontrolled
SYNTEX ENGINEERING SERVICES LTD
Eco-Tech@Sunview, 1 Sunview Road ~08-17, Singapore 349565
Tel: 6741 5311 Fax: 67425311 Email: enquiries@syntexengineering.com

Photo 7: Piping observed with minor surface rust, Photo 8: Piping observed with minor surface
no sign of corrosion scale or metal loss was rust, no sign of corrosion scale or metal loss
noticed. was noticed.

Photo 9: Piping observed with minor surface rust, Photo 10: Piping observed with minor surface
no sign of corrosion scale or metal loss was rust, no sign of corrosion scale or metal loss
noticed. was noticed.

SYN-EXM-16-007-VI-RP-001 REV: 1 11
Any hard copy printed is uncontrolled
SYNTEX ENGINEERING SERVICES LTD
Eco-Tech@Sunview, 1 Sunview Road ~08-17, Singapore 349565
Tel: 6741 5311 Fax: 67425311 Email: enquiries@syntexengineering.com

Photo 11: Branch connection observed with Photo 12: Branch connection observed with
surface rust, no sign of metal loss was noticed. surface rust, no sign of metal loss was noticed.

Photo 13: Branch connection observed with Photo 14: Piping observed with minor surface
surface rust, no sign of metal loss was noticed. rust, no sign of corrosion scale or metal loss
was noticed.

SYN-EXM-16-007-VI-RP-001 REV: 1 12
Any hard copy printed is uncontrolled
SYNTEX ENGINEERING SERVICES LTD
Eco-Tech@Sunview, 1 Sunview Road ~08-17, Singapore 349565
Tel: 6741 5311 Fax: 67425311 Email: enquiries@syntexengineering.com

Photo 15: Piping observed with minor surface Photo 16: Dummy pipe support observed with
rust, no sign of corrosion scale or metal loss was no metal loss.
noticed

Photo 17: Dummy pipe support observed with no Photo 18: Dummy pipe support observed with
metal loss. no metal loss.

SYN-EXM-16-007-VI-RP-001 REV: 1 13
Any hard copy printed is uncontrolled
SYNTEX ENGINEERING SERVICES LTD
Eco-Tech@Sunview, 1 Sunview Road ~08-17, Singapore 349565
Tel: 6741 5311 Fax: 67425311 Email: enquiries@syntexengineering.com

Photo 19: Piping observed with minor surface Photo 20: Piping observed with minor surface
rust, no sign of corrosion scale or metal loss was rust, no sign of corrosion scale or metal loss
noticed was noticed

Photo 21: Guided pipe support was observed Photo 22: Guided pipe support was observed
with surface rust and minor scaling, no sign of with surface rust and minor scaling, no sign of
major metal loss was noticed during inspection. major metal loss was noticed during inspection.

SYN-EXM-16-007-VI-RP-001 REV: 1 14
Any hard copy printed is uncontrolled
SYNTEX ENGINEERING SERVICES LTD
Eco-Tech@Sunview, 1 Sunview Road ~08-17, Singapore 349565
Tel: 6741 5311 Fax: 67425311 Email: enquiries@syntexengineering.com

Photo 23: Guided pipe support was observed Photo 24: Guided pipe support was observed
with surface rust and minor scaling, no sign of with surface rust and minor scaling, no sign of
major metal loss was noticed during inspection. major metal loss was noticed during inspection.

Photo 25: Guided pipe support was observed Photo 26: Guided pipe support was observed
with surface rust and minor scaling. with surface rust and minor scaling.

SYN-EXM-16-007-VI-RP-001 REV: 1 15
Any hard copy printed is uncontrolled
SYNTEX ENGINEERING SERVICES LTD
Eco-Tech@Sunview, 1 Sunview Road ~08-17, Singapore 349565
Tel: 6741 5311 Fax: 67425311 Email: enquiries@syntexengineering.com

Photo 27: Guided pipe support was observed Photo 28: Piping observed with minor surface
with surface rust and minor scaling. rust, no sign of corrosion scale or metal loss
was noticed.

Photo 29: Piping observed with minor surface Photo 30: Piping observed with minor surface
rust, no sign of corrosion scale or metal loss was rust, no sign of corrosion scale or metal loss
noticed. was noticed.

SYN-EXM-16-007-VI-RP-001 REV: 1 16
Any hard copy printed is uncontrolled
SYNTEX ENGINEERING SERVICES LTD
Eco-Tech@Sunview, 1 Sunview Road ~08-17, Singapore 349565
Tel: 6741 5311 Fax: 67425311 Email: enquiries@syntexengineering.com

Photo 31: Pipe Resting on the I-beam without Photo 32: Pipe Resting on the I-beam without
round bar, but no sign of corrosion deposits was round bar, but no sign of corrosion deposits was
seen beneath the pipe. seen beneath the pipe.

Photo 33: Pipe Resting on the I-beam without Photo 34: Pipe Resting on the I-beam without
round bar, but no sign of corrosion deposits was round bar, but no sign of corrosion deposits was
seen beneath the pipe. seen beneath the pipe.

SYN-EXM-16-007-VI-RP-001 REV: 1 17
Any hard copy printed is uncontrolled
SYNTEX ENGINEERING SERVICES LTD
Eco-Tech@Sunview, 1 Sunview Road ~08-17, Singapore 349565
Tel: 6741 5311 Fax: 67425311 Email: enquiries@syntexengineering.com

Photo 35: Piping observed with minor surface Photo 36: Piping observed with minor surface
rust, no sign of corrosion scale or metal loss was rust, no sign of corrosion scale or metal loss
noticed. was noticed.

Photo 37: Piping observed with surface rust, and Photo 38: Piping observed with surface rust,
minor corrosion scale, but no metal loss was and minor corrosion scale, but no metal loss
noticed. was noticed.

SYN-EXM-16-007-VI-RP-001 REV: 1 18
Any hard copy printed is uncontrolled
SYNTEX ENGINEERING SERVICES LTD
Eco-Tech@Sunview, 1 Sunview Road ~08-17, Singapore 349565
Tel: 6741 5311 Fax: 67425311 Email: enquiries@syntexengineering.com

Photo 39: Piping observed with surface rust, and Photo 40: Elbow observed with minor surface
minor corrosion scale, but no metal loss was rust, no sign of corrosion scale or metal loss
noticed. was noticed.

Photo 41: Elbow observed with minor surface Photo 42: Elbow observed with minor surface
rust, no sign of corrosion scale or metal loss was rust, no sign of corrosion scale or metal loss
noticed. was noticed.

SYN-EXM-16-007-VI-RP-001 REV: 1 19
Any hard copy printed is uncontrolled
SYNTEX ENGINEERING SERVICES LTD
Eco-Tech@Sunview, 1 Sunview Road ~08-17, Singapore 349565
Tel: 6741 5311 Fax: 67425311 Email: enquiries@syntexengineering.com

Photo 43: Piping observed with minor surface Photo 44: Piping observed with minor surface
rust, no sign of corrosion scale or metal loss was rust, no sign of corrosion scale or metal loss
noticed. was noticed.

Photo 45: Elbow observed with minor surface Photo 46: Elbow observed with minor surface
rust, no sign of corrosion scale or metal loss was rust, no sign of corrosion scale or metal loss
noticed. was noticed.

SYN-EXM-16-007-VI-RP-001 REV: 1 20
Any hard copy printed is uncontrolled
SYNTEX ENGINEERING SERVICES LTD
Eco-Tech@Sunview, 1 Sunview Road ~08-17, Singapore 349565
Tel: 6741 5311 Fax: 67425311 Email: enquiries@syntexengineering.com

Photo 47: Elbow observed with minor surface Photo 48: Piping observed with minor surface
rust, no sign of corrosion scale or metal loss was rust, no sign of corrosion scale or metal loss
noticed. was noticed.

Photo 49: Piping observed with minor surface Photo 50: Piping observed with minor surface
rust, no sign of corrosion scale or metal loss was rust, no sign of corrosion scale or metal loss
noticed. was noticed.

SYN-EXM-16-007-VI-RP-001 REV: 1 21
Any hard copy printed is uncontrolled
SYNTEX ENGINEERING SERVICES LTD
Eco-Tech@Sunview, 1 Sunview Road ~08-17, Singapore 349565
Tel: 6741 5311 Fax: 67425311 Email: enquiries@syntexengineering.com

Photo 51: Elbow observed with minor surface Photo 52: Elbow observed with minor surface
rust, no sign of corrosion scale or metal loss was rust, no sign of corrosion scale or metal loss
noticed. was noticed.

Photo 53: Elbow observed with minor surface Photo 54: Elbow observed with minor surface
rust, no sign of corrosion scale or metal loss was rust, no sign of corrosion scale or metal loss
noticed. was noticed.

SYN-EXM-16-007-VI-RP-001 REV: 1 22
Any hard copy printed is uncontrolled
SYNTEX ENGINEERING SERVICES LTD
Eco-Tech@Sunview, 1 Sunview Road ~08-17, Singapore 349565
Tel: 6741 5311 Fax: 67425311 Email: enquiries@syntexengineering.com

Photo 55: Piping observed with minor surface Photo 56: Piping observed with minor surface
rust, no sign of corrosion scale or metal loss was rust, no sign of corrosion scale or metal loss
noticed. was noticed.

Photo 57: Piping observed with minor surface Photo 58: Piping observed with minor surface
rust, no sign of corrosion scale or metal loss was rust, no sign of corrosion scale or metal loss
noticed. was noticed.

SYN-EXM-16-007-VI-RP-001 REV: 1 23
Any hard copy printed is uncontrolled
SYNTEX ENGINEERING SERVICES LTD
Eco-Tech@Sunview, 1 Sunview Road ~08-17, Singapore 349565
Tel: 6741 5311 Fax: 67425311 Email: enquiries@syntexengineering.com

Syntex Engineering Services Ltd. ExxonMobil Representative

Inspector Name: Nizam Name: Sample

Signature / Stamp: Signature / Stamp:

Date: 24/5/2017 Date: Sample