You are on page 1of 6

PROJECT TITLE: AGOO RESIDENTIAL

LOCATION: AGOO, LA UNION


OWNER:
DATE RELEASED:
BUILDING NAME: TWO-STOREY RESIDENTIAL
COLUMN NO.: C-1

1.0 Design Criteria


1.1 Design Loads
1.1.1 Dead Loads
Reinforced Concrete Unit Weight = 24 kN/m3
Super-Imposed Dead Load = 1.6 Kpa

1.1.2 Live Loads


Second Floor = 3.2 Kpa

1.2 Materials Property


1.2.1 Concrete
Concrete Compressive Strength f'c = 20.7 Mpa

1.2.2 Steel
Rebar Diameter db = 16 mm
Reinforcing Bar Yield Strength fy = 227 Mpa

1.2.3 Concrete Cover = 40 mm

Column Dimension
Length = 0.4 m
Width = 0.25 m

2.0 Loading

Weight Computations

Tributary Area = Length x Width T.A = 7.33 m2


Longitudinal = 3.2 m
Transverse = 2.29 m

2.1 Axial Loads at 2nd Floor


2.1.1 Weight of slab Ws = 29.5465 kN
Thickness of slab ts = 0.12 m
2.1.2 Weight of beam Wb = 23.058 kN
Total length of beam Lb = 5.49 m
Area of beam Ab = 0.125 m2
2.1.3 Weight of Super-Imposed Dead Load SDL = 16.4147 kN
2.1.4 Weight of Live Load LL = 39.8643 kN

2.1.5 Weight of Column Wc = 15.12 kN


Height Ht = 4.5 m

2.1.6 Total Weight Carried by Ground Floor Column Pu1 = 124.0035 kN

2.2 Axial Loads at Roof Deck


2.2.1 Weight of slab Ws = 24.6221 kN
Thickness of slab ts = 0.10 m
2.2.2 Weight of beam Wb = 18.4464 kN
Total length of beam Lb = 5.49 m
Area of beam Ab = 0.1 m2
2.2.3 Weight of Super-Imposed Dead Load SDL = 16.4147 kN

2.2.4 Weight of Live Load LL = 39.8643 kN

2.2.5 Weight of Column Wc = 10.752 kN


Height Ht = 3.2 m

2.2.6 Total Weight Carried by 2nd Floor Column Pu2 = 110.0995 kN

2.3 Ultimate Axial Load Pu = 234.1031 kN


Pu = Pu1 + Pu2

3.0 Analysis

Design Constants
Conc. Comp. Strength f'c = 20.7 Mpa
Rebar Yield Strength fy = 227 Mpa
Reduction Factor φ = 0.7
Column Gross Area AG = 10000 mm2
No. of Rebars n = 6

3.1 Considering Axial Load


Pu=0.80*φ*AG[0.85*f'c*(1/ρG)+(ρGfy)] Pu = 240.0 kN

3.1.1 Computation of ρG
ρG =AS/AG ρG = 0.12063744 >1%
<8%
Pu =240 kN>234.1031kN : Columns are SAFE
3.2 Design of Lateral Ties

Using 10mm Lateral Ties, spacing "s" must be the least value of the 3 conditions
3.2.1 16* Longitudinal Bar Ø = 256 mm

3.2.2 48* Lateral Tie Bar Ø = 480 mm

3.2.3 Least Column Size = 250 mm

Adopt 10mm Ø Lateral Ties @ 250mm O.C

You might also like