You are on page 1of 1

CONCRETE TESTING BASED ON JKR STANDARD BUILDING

SPECIFICATION 2014 (Clause 3)

New Concrete Mix by


Y
Sufficient 35
Producer. Need to do Test Results Initial Test not Require
Initial Test? in 12 months?

Do Initial Test. Prepare 9 cubes from


3 batches as minimum. Results
average of 9 cubes
Concrete is OK

Compliance Criteria = fck + Margin. Margin taken as


twice the Std Deviation. Margin expected to be Pass
between 6 to 12 N/mm2

Conformance
Standard Deviation taken from 35 test results. Refer based on
Clause 3.2.1.3 Table D13

Fail

N
Supplier propose new mix Initial Test Result Sampling Based on
Complied? Cl. 3.4.2.1

Y
Do Identity Test
Produce Continuous Concrete Production

Concrete supplied to
Carry Out Conformance Control Test site

Conformance based N Y
on Initial Test Criteria Are there more
than 35 results
done in 1 year?
Conform to
Specification?
Y ?

Conformance based on
N
Conformity Control Test Criteria
Table D11
Non Conformance Product
Refer Clause 3.3

Legend: Contractor’s S.O’s


Responsibility Responsibility

You might also like