Professional Documents
Culture Documents
Phone : 05 55 06 87 87 – Fax : 05 55 06 88 88
CONTENTS PAGES
1.Range 1 to 2
2.Finishing accessories 3 to 6
3.Supports 7 to 9
4.Complementary accessories 10 to 12
5.Material characteristics 12
6.Technical characteristics 13 to 14
The system of distribution DLP full aluminium 6060-T5 anodic 1.1 Bodies DLP aluminium (suite).
natural offers:
Dimensions of trunkings :
- perfect flexible installations in time.
- the distribution, the protection and the derivation of cables in an
electrical installation.
- trunkings, accessories of completion and advance
(end, joint of lid, joint of body, interior angle, exterior angle, flat
angle, derivation)
Wiring capacity.
Bodies ref. 11100/01/02/03/04/05/14
Section Ø maxi
Delivered in length of 2m without cover Reference Body Cover (mm²) (mm²)
Color natural anodized aluminium. 11114 105x50 65 4380 2x36
11100 105x50 85 4300 42
Fixing by:
11101 105x65 85 5740 55
- wall plugs for immediate fixing (without screw nor nail ref. 30899) 11102 150x50 130 6440 2x42
- DLP rapid wall plug ref 30897 (for 10mm maxi plasterboard walls 11102 150x50 2x65 2x2930 42/42
at least 20mm away from the concrete surface)
- Spit end cap ref 10695 (for rapid fixing of trunkings with the spit 11103 150x65 130 8200 2x55
Pulsa 700E 11103 150x65 2x65 2x3960 51/51
- screw, nails… 11104 195x50 180 8460 3x42
Cut out using a saw (standard hacksaw) and of a cut box 11104 195x50 2x85 2x3940 42/42
(réf.30698) 11105 195x65 180 11240 3x54
Possibility of adapting separation partition or division partition. 11105 195x65 2x85 2x5310 55/55
1 of 14
DLP full aluminium. Number(s) : 11100 à 11115, 11157 à 11182,11188 à 11194,
11202/03/04/06/08/12/13/14/16/18/20 à 48, 11250 à 56,11260,
10681/82/86, 10917/27, 30881
2 of 14
DLP full aluminium. Number(s) : 11100 à 11115, 11157 à 11182,11188 à 11194,
11202/03/04/06/08/12/13/14/16/18/20 à 48, 11250 à 56,11260,
10681/82/86, 10917/27, 30881
2.1 Internal angle ref. 11220/21/22/23/24/25/26/27/28/29/30. 2.2 External angle ref. 11231/32/33/34/35/36/37/38/39/40/41.
3 of 14
DLP full aluminium. Number(s) : 11100 à 11115, 11157 à 11182,11188 à 11194,
11202/03/04/06/08/12/13/14/16/18/20 à 48, 11250 à 56,11260,
10681/82/86, 10917/27, 30881
2.3 Flat angle ref. 11242/43/44/45/46/47/48. 2.4 Flat junction ref. 11250/51/52/53
base
plate
Table of choice of the flat angles: 11251: Derivation starting from a section height 50mm allows
towards a section width 105mm equipped with a cover 85mm
Reference Internal angle To use with trunking 11252: Derivation starting from a section height 50mm allows
11242 105x50 Cover 65mm towards a section width 105mm equipped with a cover 65mm
11243 105x50 Cover 85mm
11253: Derivation starting from a section height 65mm allows
11244 105x65 Cover 85mm towards a section width 105mm equipped with a cover 85mm
11245 150x50 Cover 65/130mm
11246 150x65 Cover 65/130mm Table of choice of the flat junctions:
11247 195x50 Cover 85/180mm
11248 195x65 Cover 85/180mm To tap-off to To tap-off to
105mm wide 105mm wide
Reference trunking trunking
trunking equipped with a equipped with a
65mm cover 85mm cover
11114 11250
11100 11252 11251
11101 11253
11102 11252 11251
11103 11253
11104 11252 11251
11105 11253
4 of 14
DLP full aluminium. Number(s) : 11100 à 11115, 11157 à 11182,11188 à 11194,
11202/03/04/06/08/12/13/14/16/18/20 à 48, 11250 à 56,11260,
10681/82/86, 10917/27, 30881
2.5 Angled junction ref. 11255/56/60 2.6. End cap ref. 11115/58/59/60/61/89/90.
5 of 14
DLP full aluminium. Number(s) : 11100 à 11115, 11157 à 11182,11188 à 11194,
11202/03/04/06/08/12/13/14/16/18/20 à 48, 11250 à 56,11260,
10681/82/86, 10917/27, 30881
2.7 Cover joint ref. 11162/63/64/65 2.8 Body joint ref. 11166/91/92
Allows: Allows:
- the junction end to end of two of the same lids section - the junction end to end of two same section
- respect of the degree protection - respect of the degree protection
- to improve aesthetics (covering of the cut) - to improve aesthetics (covering of the cut)
Assembly of the joint by clipsage Grey color RAL 7035, painted in grey aluminium.
Grey color RAL 7035, painted in grey aluminium. Ref 11166, body joint attached with adhesive (fit at the end of
installation)
6 of 14
DLP full aluminium. Number(s) : 11100 à 11115, 11157 à 11182,11188 à 11194,
11202/03/04/06/08/12/13/14/16/18/20 à 48, 11250 à 56,11260,
10681/82/86, 10917/27, 30881
3.1 Supports for Mosaic ref. 11202/04/06/08/12/14/16/18 3.1 Supports for Mosaic ref. 11202/04/06/08/12/14/16/18
Dimensions of supports :
Cover plates :
Dimensions of supports :
Thickness of cover plates
For cover 65mm.
Y (mm) = cover plates width 67.5mm, supports width 64.5mm.
7 of 14
DLP full aluminium. Number(s) : 11100 à 11115, 11157 à 11182,11188 à 11194,
11202/03/04/06/08/12/13/14/16/18/20 à 48, 11250 à 56,11260,
10681/82/86, 10917/27, 30881
3.2 Supports for Mosaic ref. 11175/76/77/78/79/80/81/82/93/94 3.2 Supports for Mosaic ref.11175/76/77/78/79/80/81/82/93/94
Dimensions of supports :
Cover plates :
Dimensions of supports :
For cover 65mm.
Thickness of cover plates Y(mm)= cover plates width 67.5mm, supports width 64.5mm.
8 of 14
DLP full aluminium. Number(s) : 11100 à 11115, 11157 à 11182,11188 à 11194,
11202/03/04/06/08/12/13/14/16/18/20 à 48, 11250 à 56,11260,
10681/82/86, 10917/27, 30881
3.3 Supports for 60mm fixing centres wiring accessories ref. 3.3 Supports for 60mm fixing centres wiring accessories ref.
11167/68/69/70/71/72/73/74. 11167/68/69/70/71/72/73/74.
Dimensions of supports :
Cover plates :
Dimensions of supports :
Thickness of cover plates
9 of 14
DLP full aluminium. Number(s) : 11100 à 11115, 11157 à 11182,11188 à 11194,
11202/03/04/06/08/12/13/14/16/18/20 à 48, 11250 à 56,11260,
10681/82/86, 10917/27, 30881
4.1 Flat junction for specific sizes ref. 11157 and 11254 4.1 Flat junction for specific sizes ref. 11157 and 11254
Dimensions:
10 of 14
DLP full aluminium. Number(s) : 11100 à 11115, 11157 à 11182,11188 à 11194,
11202/03/04/06/08/12/13/14/16/18/20 à 48, 11250 à 56,11260,
10681/82/86, 10917/27, 30881
Allows:
- to retain the cables inside the trunking
4.3 Base for cable ties ref 30881 Assembly of the clip by clipsage inside the body of the trunking.
References Cover
10681 65mm
10682 40/65/85mm
10686 130/180mm
11 of 14
DLP full aluminium. Number(s) : 11100 à 11115, 11157 à 11182,11188 à 11194,
11202/03/04/06/08/12/13/14/16/18/20 à 48, 11250 à 56,11260,
10681/82/86, 10917/27, 30881
4.5 Insulation unit ref 10917/27. The trunking covers and partitions are in anodized aluminium 6060-
T5.
Insulation unit (ref 10927) for 2 modules, can be fitted together to Plastic accessories:
create 4, 6 and 8 modules supports
(allows the insulation of the mechanism in the trunking, assembly by The accessories below are in plastic (PVC or ABS) with painting
clipsage on the support) grey color aluminium:
Ref 10917
Insulation unit
12 of 14
DLP full aluminium. Number(s) : 11100 à 11115, 11157 à 11182,11188 à 11194,
11202/03/04/06/08/12/13/14/16/18/20 à 48, 11250 à 56,11260,
10681/82/86, 10917/27, 30881
6. TECHNICAL CHARACTERISTICS.
UTP &
Section Diameter 3x1,5 3x2,5
Capacity 1,5 mm² 2,5 mm² 4 mm² 6 mm² FTP
mm² max mm² mm²
CAT.6
13 of 14
DLP full aluminium. Number(s) : 11100 à 11115, 11157 à 11182,11188 à 11194,
11202/03/04/06/08/12/13/14/16/18/20 à 48, 11250 à 56,11260,
10681/82/86, 10917/27, 30881
Impédance = 5 mOhm/m