Technical features
Medium: Element: Drain: Materials:
Compressed air Standard: 40 ... 50 μm Manual or automatic Valve body, top & bottom covers,
Operating pressure: Optional: 5 ... 10 μm, 20 ... 30 μm Fluid/Ambient temperature: valve trim: 316 stainless steel
20 bar (290 psi) maximum Port sizes: Standard: Seat and spring: stainless steel
Outlet pressure range: Standard: 1/4 NPT, 1/2 NPT -30 ... +90°C (-22 ... +194°F) O-rings, seals and diaphragm:
Standard: 1/8 NPT (gauge) Optional: NBR
0,5 ... 10 bar (7 ... 145 psi) Optional: -55 ... +90°C (-67 ... +194°F)
Optional: G1/4 or G1/2; G1/8 (gauge) Air supply must be dry enough to See option selector for variants
0,5 ... 6/16 bar (7 ... 87/232 psi) Relief port: avoid ice formation at temperatures
Flow characteristics: ø 2 mm below +2°C (+35°F).
See page 2
*1) Outlet pressure can be adjusted to pressures in excess of, and less than, those specified.
Do not use these units to control pressures outside of the specified ranges.
*2) Typical flow with 10 bar (145 psi) inlet pressure, 6,3 bar (91 psi) set pressure and a 1 bar (14 psi) drop from set.
G1/2 E3
Seat/seal materials Substitute
NBR (standard) H
FKM V
Low temperature variant L
(-55 ... 90°C )
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice,
05/18
the specifications given in this document. (2005 - 8169f) © IMI Precision Engineering, Thompson Valves Ltd. en 8.540.300.01
IFR3 & IFR4
Filter/regulator (stainless steel)
Flow characteristics
1/4” 1/2”
bar bar
10 10
9 9
8 8
7 7
Inlet pressure
Inlet pressure
6 6
5 5
4 4
3 3
2 2
1 1
0 0
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 dm3/s 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 dm3/s
Air flow
Dimensions 13 1 13 1
Dimensions in mm
Projection/First angle
4 4
82,5
85,5
2 2
204
210
82,5
85,5
3 3
1 Adjustment screw
2 1/8 NPT Gauge port
16
16
3 Manual drain
46 56 46 56
4 Relief vent ø 2 mm
56 70
95
5,6
2
65,5
40
40
48
60
Warning
These products are intended for use in industrial compressed air The system designer is warned to consider the failure modes of all
systems only. Do not use these products where pressures and component parts used in fluid power systems and to provide adequate
temperatures can exceed those listed under safeguards to prevent personal injury or damage to equipment in the
»Technical features/data«. event of such failure.
Before using these products with fluids other than those specified, System designers must provide a warning to end users in the system
for non-industrial applications, life-support systems or other instructional manual if protection against a failure mode cannot be
applications not within published specifications, consult adequately provided.
IMI Precision Engineering, Thompson Valves Ltd. System designers and end users are cautioned to review specific
Through misuse, age, or malfunction, components used in fluid warnings found in instruction sheets packed and shipped with these
power systems can fail in various modes. products.
For further information please see Functional Safety Manual MI0560.
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice,
en 8.540.300.02 the specifications given in this document. (2005 - 8169f) © IMI Precision Engineering, Thompson Valves Ltd. 05/18