You are on page 1of 38

PHYSICS HALL

EXTERIOR
ARCH 571
DESIGN FOR ALL PEOPLE

PRITHVISINGH BISEN
CHARLIE WICKHAM
SHAMBHAVI SRIVASTAVA
PHYSICS HALL
Constructed in 1923

Renovated in 1950, 1961

Total Area : 79,686 sq.ft

ADA Requirement says


60% Accessible
entrance doors.

Current situation : 1
out of 6 doors
accessible i.e. 16%

1 out of 4 entrances
accessible i.e. 25%
PHYSICS HALL ACCESSIBILITY MAP
ACCESS POINTS

Wilhelm Hall
Science II
Ames Lab

Zaffarano Hall
Lot 36

Gilman Hall
Science I
Physics Hall
PARKING
ACCESS POINTS

BY BIKE

FROM CAMPUS
BY BUS
VEHICULAR ENTRANCE / PARKING LOT ENTRANCE
PARKING DETAILS
“Van Accessible”
Pers. #

8.5’ 8.5’ 6’ 8.5’ 8.5’ 8.5’

Not Accessible Only Accessible Alt. Van Accessible


PARKING DETAILS

%
.7
10
1.6%

0%
6.0%

2.
3.9%

7.7%
%
4.4

3.3% 0.1%
5.1% 0.8%
1.3%
4.3%
5.6%
2.3% 1.9%
5.6% 5.0%
5.4%
SUGGESTIONS - PARKING

Short Term: Long Term:


- Remove “Van Accessible” from the Regular - Regrade parking lot, limit slopes to 5% or

Accessible Space less

- Add access aisle to Personnel space - Add Curb Ramp to second Access Aisle
- Move accessible spaces to flat area
- Add colored concrete to prevent cars from
being in the way on the sidewalks

2.3%
1.3%
DOORS
3
ADA Requires 60% of
entrances be accessible
EN A5 [1] 4
Door 3a:
“Accessible alternative”
to door 3 3a

5
1
DOOR 1 - FIRST FLOOR (ACCESSIBLE)

DOOR PRESSURE : 15 LBS.


DOOR HEIGHT : 6 FEET HEIGHT OF ACCESS
RAILINGS : NONE BUTTON : 29 ‘’
SLOPE : 4.6% HEIGHT OF THRESHOLD : ¼ ‘’
DOOR WIDTH : 34 ‘’ DIST BTW ACCESS BUTTON
HANDLE HEIGHT : 30 ‘’ AND DOOR : 9’-10’’
DOOR 1 - FIRST FLOOR (ACCESSIBLE)

1.4%
1.4% 1.6%
4.1% 3.1% 0.5%
0.1% 1.7%
3.7%
1.6%

2.3%
1.7%
DOOR 1 - FIRST FLOOR (ACCESSIBLE)

5”

7”

4.6%
34”
Dark Interior
Too Much Reflection

6”
SUGGESTIONS - DOOR 1

Short Term: Long Term:


- Regrade area on sides of route - Remove shared Door Stop, replace with
- Fill gap in front of Automatic Opener Double Leaf Door
- Put Anti-Reflective coating on windows - Increase Lighting in Interior
- Reduce slope at opener by increasing slope
further down

4.8%
3.1%
DOOR 2 - FIRST FLOOR (NOT ACCESSIBLE)

DOOR HEIGHT : 6 FEET


DOOR PRESSURE : 20 LBS.
WIDTH OF HANDRAILS : 14.5’’
RISERS : 6’’, 6’’, 5.5’’, 5.5’’, 6.5’’
LANDING : 2’
DOOR 2 - FIRST FLOOR (NOT ACCESSIBLE)

1.4% 0.9
5.3%
4.7%

3.0%

6.2%

2.9%
1.4%
DOOR 2 - FIRST FLOOR (NOT ACCESSIBLE) Half Landing

20” 6”
25” 7”
No Graspable Handrail
Steps Blend Together
SUGGESTIONS - DOOR 2

Short Term: Long Term:


- Add Handrails and High Friction Contrast - Regrade Pathways to eliminate excessive
strips to each tread running and cross slopes
- Extend Concrete Landing
DOOR 3 - FIRST FLOOR (NOT ACCESSIBLE)

0.3%

0.8%

DOOR HEIGHT : 6 FT
DOOR PRESSURE : 14 LBS.
HANDLE HEIGHT : 30’’
DOOR WIDTH : 34’’
SUGGESTIONS - DOOR 3

Short Term: Long Term:


- Mark as Non-Accessible - Install Interior Elevator next to entrance
- Add Automatic Door Opener
DOOR 3a - BASEMENT (ACCESSIBLE BUT …?)

DOOR HEIGHT : 6 FT DOOR WIDTH : 36’’


DOOR PRESSURE : 10 LBS CIRCUMFERENCE OF
DOOR VISIBILITY : POOR RAILING : 5.5 ‘’
ROUTE WIDTH : 4’-4’’ HEIGHT OF RAIL : 36’’
HANDLE HEIGHT : 31’’
DOOR 3a - BASEMENT
42”

10.0%

0.5%

10.0%

Landing 10.0%
DOOR 3a - BASEMENT (ACCESSIBLE BUT …?)
3.2%
Avg.

≅400’
SUGGESTIONS - DOOR 3a

Short Term: Long Term:


- Put up Sign directing to Front Door for - Regrade Slope under 8.3%
Accessible Classroom Entry - Replace Door with View Panel
- Make Door 3 accessible, remove 3a entirely
DOOR 4 - FIRST FLOOR (EXIT, NOT ACCESSIBLE)

DOOR HEIGHT : 6 FT
DOOR PRESSURE : 10 LBS
DOOR WIDTH : 36’’
SUGGESTIONS - DOOR 4

Short Term:
- Unlock the door from the outside
- Extend handrails one tread past the end of
the staircase

Long Term:
- Grade up to entrance instead of the stairs
- Make the door automatic with Accessibility
DOOR 5 - FIRST FLOOR (EXIT, NOT ACCESSIBLE)

DOOR HEIGHT : 6 FT
DOOR PRESSURE : 10 LBS
DOOR WIDTH : 36’’
SUGGESTIONS - DOOR 5

Short Term :
- Build a pathway connecting Door 5 to the
main access road.
- Have the door unlocked from outside as well
to make it an entry point and not just an
exit.

Long Term :
- Add an automatic door with Accessibility.
ALL SUGGESTIONS
Short Term: Long Term:
Parking
- Remove “Van Accessible” from the Regular - Regrade parking lot, limit slopes to 5% or less
Accessible Space - Add Curb Ramp to second Access Aisle
- Add access aisle to Personnel space - Move accessible spaces to flat area
- Add colored cement to prevent cars from being in the way
on the sidewalks
Door 1
- Regrade area on sides of route - Remove shared Door Stop, replace with Double Leaf Door
- Fill gap in front of Automatic Opener - Increase Lighting in Interior
- Put Anti-Reflective coating on windows - Reduce slope at opener by increasing slope further down
Door 2
- Add Handrails and High Friction Contrast strips - Regrade Pathways to eliminate excessive running and
to each tread cross slopes
- Extend Concrete Landing
Door 3 and 3a
- Mark as Non-Accessible - Install Interior Elevator next to entrance
- Add Automatic Door Opener - Regrade Slope under 8.3%
- Put up Sign directing to Front Door for Accessible - Replace Door with View Panel
Classroom Entry - Make Door 3 accessible, remove 3a entirely
Door 4
- Unlock the door from the outside - Grade up to entrance instead of the stairs
- Extend handrails one tread past the end of the - Make the door automatic with Accessibility
staircase
Door 5
- Build a pathway connecting Door 5 to the main - Add an automatic door with Accessibility.
access road.
- Have the door unlocked from outside as well to
make it and entry point and not just an exit.
Thank You!
What questions do you have?

Sources:
- Osterberg, Dr. Arvid E, “Access for Everyone, A guide to the accessibility of
buildings and sites with references to 2010 ADASAD” Third Edition
- Iowa State University Facilities Planning and Management, “Physics Hall”
Building information directory
ZAFFARANO