EXTERIOR
ARCH 571
DESIGN FOR ALL PEOPLE
PRITHVISINGH BISEN
CHARLIE WICKHAM
SHAMBHAVI SRIVASTAVA
PHYSICS HALL
Constructed in 1923
Current situation : 1
out of 6 doors
accessible i.e. 16%
1 out of 4 entrances
accessible i.e. 25%
PHYSICS HALL ACCESSIBILITY MAP
ACCESS POINTS
Wilhelm Hall
Science II
Ames Lab
Zaffarano Hall
Lot 36
Gilman Hall
Science I
Physics Hall
PARKING
ACCESS POINTS
BY BIKE
FROM CAMPUS
BY BUS
VEHICULAR ENTRANCE / PARKING LOT ENTRANCE
PARKING DETAILS
“Van Accessible”
Pers. #
%
.7
10
1.6%
0%
6.0%
2.
3.9%
7.7%
%
4.4
3.3% 0.1%
5.1% 0.8%
1.3%
4.3%
5.6%
2.3% 1.9%
5.6% 5.0%
5.4%
SUGGESTIONS - PARKING
- Add access aisle to Personnel space - Add Curb Ramp to second Access Aisle
- Move accessible spaces to flat area
- Add colored concrete to prevent cars from
being in the way on the sidewalks
2.3%
1.3%
DOORS
3
ADA Requires 60% of
entrances be accessible
EN A5 [1] 4
Door 3a:
“Accessible alternative”
to door 3 3a
5
1
DOOR 1 - FIRST FLOOR (ACCESSIBLE)
1.4%
1.4% 1.6%
4.1% 3.1% 0.5%
0.1% 1.7%
3.7%
1.6%
2.3%
1.7%
DOOR 1 - FIRST FLOOR (ACCESSIBLE)
5”
7”
4.6%
34”
Dark Interior
Too Much Reflection
6”
SUGGESTIONS - DOOR 1
4.8%
3.1%
DOOR 2 - FIRST FLOOR (NOT ACCESSIBLE)
1.4% 0.9
5.3%
4.7%
3.0%
6.2%
2.9%
1.4%
DOOR 2 - FIRST FLOOR (NOT ACCESSIBLE) Half Landing
20” 6”
25” 7”
No Graspable Handrail
Steps Blend Together
SUGGESTIONS - DOOR 2
0.3%
0.8%
DOOR HEIGHT : 6 FT
DOOR PRESSURE : 14 LBS.
HANDLE HEIGHT : 30’’
DOOR WIDTH : 34’’
SUGGESTIONS - DOOR 3
10.0%
0.5%
10.0%
Landing 10.0%
DOOR 3a - BASEMENT (ACCESSIBLE BUT …?)
3.2%
Avg.
≅400’
SUGGESTIONS - DOOR 3a
DOOR HEIGHT : 6 FT
DOOR PRESSURE : 10 LBS
DOOR WIDTH : 36’’
SUGGESTIONS - DOOR 4
Short Term:
- Unlock the door from the outside
- Extend handrails one tread past the end of
the staircase
Long Term:
- Grade up to entrance instead of the stairs
- Make the door automatic with Accessibility
DOOR 5 - FIRST FLOOR (EXIT, NOT ACCESSIBLE)
DOOR HEIGHT : 6 FT
DOOR PRESSURE : 10 LBS
DOOR WIDTH : 36’’
SUGGESTIONS - DOOR 5
Short Term :
- Build a pathway connecting Door 5 to the
main access road.
- Have the door unlocked from outside as well
to make it an entry point and not just an
exit.
Long Term :
- Add an automatic door with Accessibility.
ALL SUGGESTIONS
Short Term: Long Term:
Parking
- Remove “Van Accessible” from the Regular - Regrade parking lot, limit slopes to 5% or less
Accessible Space - Add Curb Ramp to second Access Aisle
- Add access aisle to Personnel space - Move accessible spaces to flat area
- Add colored cement to prevent cars from being in the way
on the sidewalks
Door 1
- Regrade area on sides of route - Remove shared Door Stop, replace with Double Leaf Door
- Fill gap in front of Automatic Opener - Increase Lighting in Interior
- Put Anti-Reflective coating on windows - Reduce slope at opener by increasing slope further down
Door 2
- Add Handrails and High Friction Contrast strips - Regrade Pathways to eliminate excessive running and
to each tread cross slopes
- Extend Concrete Landing
Door 3 and 3a
- Mark as Non-Accessible - Install Interior Elevator next to entrance
- Add Automatic Door Opener - Regrade Slope under 8.3%
- Put up Sign directing to Front Door for Accessible - Replace Door with View Panel
Classroom Entry - Make Door 3 accessible, remove 3a entirely
Door 4
- Unlock the door from the outside - Grade up to entrance instead of the stairs
- Extend handrails one tread past the end of the - Make the door automatic with Accessibility
staircase
Door 5
- Build a pathway connecting Door 5 to the main - Add an automatic door with Accessibility.
access road.
- Have the door unlocked from outside as well to
make it and entry point and not just an exit.
Thank You!
What questions do you have?
Sources:
- Osterberg, Dr. Arvid E, “Access for Everyone, A guide to the accessibility of
buildings and sites with references to 2010 ADASAD” Third Edition
- Iowa State University Facilities Planning and Management, “Physics Hall”
Building information directory